Skip to main content
Erschienen in: BMC Oral Health 1/2024

Open Access 01.12.2024 | Research

Effectiveness of a low-intensity static magnetic field in accelerating upper canine retraction: a randomized controlled clinical trial

verfasst von: Nataly N. Alqaisi, Rania A. Haddad, Hani M. Amasha

Erschienen in: BMC Oral Health | Ausgabe 1/2024

Abstract

Introduction

Neodymium-iron-boron magnets have been suggested as a contemporary method for accelerating the process of orthodontic tooth movement (OTM).
A limited number of clinical trials evaluated their effectiveness in accelerating OTM which is desirable for both orthodontists and patients.
The present study aimed to investigate the effectiveness of a low-intensity static magnetic field (SMF) in accelerating upper canine retraction movement.

Materials and methods

Seventeen patients (mean age 20.76 ± 2.9 years) with their orthodontic treatment decision to extract the upper and lower first premolars due to bimaxillary protrusion malocclusion were included in this split-mouth study. Canine retraction was performed using Nickel-titanium (Ni-Ti) closed-coil springs (150 g of force on each side). The experimental side received SMF via an auxiliary wire that carried 4-neodymium iron-born magnets with an air gap of 2 mm between the magnets to produce a magnetic field density of 414 mT in the region corresponding to the lateral ligament of the upper canine. To determine the rate of upper canine retraction and upper molar drift, alginate impressions were taken once a month to create plaster casts, which were analyzed digitally via a three-dimensional method.

Results

The rate of upper canine retraction was significantly greater (P < 0.05) on the SMF side than that on the control side during the first and second months, with an overall duration (19.16%) that was greater than that on the control side. The peak acceleration occurred during the second month (38.09%).
No significant differences in upper molar drift were detected between the experimental and control sides (P > 0.05).

Conclusion

A low-intensity static magnetic field was effective at accelerating upper canine retraction. The difference between the two sides was statistically significant but may not be clinically significant.
The SMF did not affect upper molar drift during the upper canine retraction phase.

Trial registration

The trial was retrospectively registered at the ISRCTN registry (ISRCTN59092624) (31/05/2022).
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

The introduction of modern therapeutic methods contributes prominently to theories of contemporary orthodontics [1]. Among these, the concept of accelerated OTM is to achieve normal occlusion with shortening treatment period, and minimal side effects on the teeth and periodontal tissue [2, 3]. Various physical methods, such as low-level laser therapy (LLLT) [2], static magnetic field (SMF) [4], and pulsed electromagnetic field (PEMF) [5, 6], are employed in OTM acceleration. Recent animal studies have shown that the SMF may possibly shorten the duration of orthodontic treatment [4, 7].
Similarly, histological studies have revealed that alveolar bone remodeling process is likely to be activated under the influence of magnetic fields, as the activity of osteoblasts increases new bone deposition on the tension side [1, 8]. Magnetic fields have the advantage of being able to cross both the mucous membrane and bone [9]; notably, they do not require patient cooperation [10].
The recent development of small magnets made of new, powerful permanent magnetic alloys (neodymium- iron- boron) also known as rare earth magnets, has led to an increase in the use of magnets [11]. Such magnets are 20 times stronger than the magnets used previously; thus, they can be used at a size 20 times smaller than the previous ones with the same amount of resulting force. This feature made them suitable for the use inside the oral cavity easier and more comfortable for patients [11]. The magnetic flux density was measured with a Tesla (T) or Milli-Tesla (mT) [11].
However, few studies in the literature have examined the effect of static magnetic field (SMF) therapy on the rate of OTM in short-term animals [4, 7]. The SMF has been utilized in various randomized controlled clinical trials (RCTs) for orthodontic treatment, such as correction of Class II malocclusion [12], correction of Class III malocclusion [13], and closure of midline diastemas [14].
On the other hand, recent studies have suggested that a static magnetic field can enhance the effectiveness of anticancer drugs while minimizing cytotoxicity and side effects [1517].
Accordingly, the primary objective of this study was to investigate the effectiveness of a low-intensity static magnetic field (SMF) in accelerating upper canine retraction movement and reducing treatment duration. The secondary aim was to evaluate upper molar drift following canine retraction.
Null hypothesis (H0): Applying a static magnetic field does not lead to the acceleration of upper canine retraction or upper molar drift in the context of orthodontic treatment.

Materials and methods

Ethics approval and patient consent

This prospective, randomized, single-center, single-blinded, split-mouth study was approved by the institutional review board and the ethical review committee of Damascus University (no. 906/22-11-2021) and was retrospectively registered at the ISRCTN registry (identifier: ISRCTN59092624). This randomized clinical trial with a split-mouth design was written according to the Consolidated Standards of Reporting Trials (CONSORT) statement [18]. Patient recruitment started in August 2021 and ended in November 2021.
Each maxilla was randomly split into two halves (the experimental side, on which a static magnetic field (SMF) was applied; and the contralateral side, not receiving the SMF and serving as a control).

Sample size calculation and participants

G*power 3.1.9.7 software (Universität Düsseldorf, Düsseldorf, Germany) was used to calculate the sample size based on the speed of upper canine retraction using the mean and standard deviation from a prior related study [19], with the following assumptions; a paired t-test with a power of 95%, a significance level of 0.05, and an effect size of 0.93. Consequently, the calculated sample size was 17 patients (34 canines).

Participants and eligibility criteria

The treatments were performed by the same orthodontist (N.A). Clinical examination, intraoral and extraoral photographs, dental casts, and radiographic records were taken before starting orthodontic treatment for 30 patients referred to the Department of Orthodontics. Eighteen patients met the inclusion criteria. Only one of them has withdrew for travel reasons. All patients fulfilled the following inclusion criteria: Adult patients (18–28 years old) with full permanent dentition, bimaxillary protrusion, dental class I relationship of the canines and molars according to Angle classification, class I or II skeletally, normal or excessive facial height (Bjork > 390֯), healthy periodontal tissues and reasonable oral health (Plaque index ≤ 1), no previous orthodontic treatment, and nonsmokers. The subject exclusion criteria: were patients suffering from systemic diseases or syndromes, and those who had impacted teeth.
Informed consent was obtained from all patients who met these criteria.

Randomization, allocation concealment, and blinding

Simple randomization was conducted by using random computer-generated numbers (Minitab Statistical Software: version 20) with an allocation ratio of 1:1 performed by one of the academic staff (not involved in this research) at the Department of Orthodontics.
The allocation sequence was concealed using sequentially numbered, opaque, closed envelopes, which were opened only before the beginning of upper canine retraction.
Patient and practitioner blinding was not applicable. Therefore, blinding was applied only for the outcome assessor while recording plaster-distributed casts with serial numbers to ensure blinding and avoid bias in the investigation, after removing the magnetic appliance for taking the impressions at all times of investigation.

Intervention

In the initial phase, the soldered transpalatal arches were placed as moderate anchors, before extracting the upper and lower first premolars. One week later, leveling and alignment were started using a straight wire, ‘0.022’ slot MBT appliance (Mini Master Series, American Orthodontics, Sheboygan, USA) with the following arch wire sequence: 0,014-in. NiTi, 0.016-in. NiTi, 0,016 × 0,022-in. NiTi, 0,017 × 0,025-in. NiTi, 0,019 × 0,025-in. Stainless steel (S.S.) (the basal arch-wire) was used. The second phase was one month after applying the basal wire when an alginate impression of the maxillary arch was taken. Then upper and lower canine distalization was started using NiTi closed-coil springs (Jiscop, Gunpo-si, Korea) extended from the hook of the molar band to the hook of the canine bracket. The generated force was calibrated using an intraoral dynamometer (040-711-00, Dentaurum, Ispringen, Germany). The medium force of the Ni-Ti closed coil spring was calibrated and readjusted when necessary to maintain it at a 150 g level during the whole retraction phase. The spring was replaced with a shorter spring when needed. For the experimental side, the acceleration of upper canine retraction was investigated by applying a static magnetic field through an auxiliary wire carrying the magnet (Fig. 1).

Application of a static magnetic field

The magnetic appliance used for accelerating upper canine retraction was as follows:
  • A- Four Neodymium-iron-boron (Nd-Fe-B) magnets without cobalt, which can maintain magnetism permanently and are coated with titanium and circularly shaped materials with a diameter of 4 mm and a height of 1 mm, were used (Magnet Expert).
  • B- Straight S.S. wire 0.016 × 0.022-in.
  • C- MBT 0.022-in upper canine brackets with a vertical slot.
  • D- Circular rings, carrying the magnet, formed on an auxiliary 0.016 × 0.022-in. S.S straight wire, by a Tweed plier so that the 4 mm diameter neodymium magnets could be placed inside the matched circular rings (two magnets at each pole). The auxiliary wire contained a loop with a distance of 2 mm between the poles to represent the air gap between the magnets so that they produced a magnetic field density of 414 mT in the region corresponding to the lateral ligament of the upper canine. The magnetic field density was measured by a Digital Tesla meter (Dexing Magnet Tech. Co., Ltd.) with the Hall probe device which is an electronic device that allows accurate measurement of the intensity of the magnetic field with a 1 mm diameter probe placed between the magnets (Fig. 2). The auxiliary wire carrying the magnet was fixed between the vertical slot of the upper canine bracket and the auxiliary tube of the upper molar band (Fig. 3), with the appliance moves freely within the auxiliary tube of the molar band and applies no forces; thus, there are no differential friction implications between the experimental and control sides because the vertical slot is not connected with the horizontal slot of the base wire (Fig. 4). The auxiliary wire carrying the magnet was covered with flexible vacuum-formed sheets of 0.5 mm thickness.

Follow-up during canine retraction

Patients were followed up through the canine retraction phase once a month, during which the spring was reactivated to maintain a force of 150 g on both sides.
The springs and auxiliary wire carrying the magnet were monitored periodically every 2 weeks, and alginate impressions were taken once a month.
The total follow-up period started with the onset of canine retraction and was concluded when canine retraction was accomplished.

Outcome measures

The rate of canine movement was the primary outcome measurements, and the upper molar drift was the secondary outcome measurements.
The rates of upper canine retraction and upper molar drift were recorded once a month using plaster casts and analyzed in a three-dimensional manner. Transferred scanned casts were analyzed digitally (Exocad - Dental CAD 3.1 Rijeka). A digital scanner (MEDIT, T710, Seoul, South Korea), which has a high accuracy of 11 microns, was used. The accuracy and reliability of this method have been proven by previous studies [2022].
Dental casts were obtained at five time points: (T0) before canine retraction, (T1) after one month, (T2) after two months, (T3) after three months, and (T4) after four months. A T-Final was considered for each patient when one of the upper canines was fully retracted.
Superimposition was performed between each cast and the next cast at the measuring time points (T0-T1, T1-T2, T2-T3, T3-T4, and T0-Tf), depending on the palatal rugae region as a fixed area [23] (Fig. 5). The cusp tip of the upper canine was determined, and the distance between the two cusps was measured occlusally to evaluate anterior-posterior canine movement (Fig. 6); then, the speed of upper canine retraction was calculated (mm/month).
To evaluate molar anchorage loss, superimposition was performed between each cast and the next cast at specific time points [24] (T0-T1, T1-T2, T2-T3, T3-T4, and T0-Tf), using the palatal rugae region as a fixed area [23].
The central fossa of the maxillary first permanent molars was identified at each time point, and the distance between the two central fossae was measured occlusally to determine the amount of anterior-posterior movement of the maxillary first permanent molars (Fig. 7). Subsequently, the speed of upper molar drift was calculated (mm/month).

The error of method

One month after the first measurement, twenty casts were randomly chosen to calculate the method error for the recorded measurements. The supper imposition was repeated, all reference points were redetermined, and the entire measurements were recorded using the same program (Exocad - Dental CAD 3.1 Rijeka).
A paired t test was conducted to evaluate systematic errors (investigating validity). Moreover, there was no significant difference (P < 0.05) between the two measurements (Table 1).
Table 1
Assessment of systematic error in the current study (n = 20 casts) using paired t test
 
(SD) 1st measurement
(SD) 2nd measurement
Mean Difference
The confidence interval 95%
t value
P value
Lower
Upper
C.Disp
1.70
1.70
0.00
0.00357-
0.00697
0.676
0.507
(NS)
SD Stander deviation, C.Disp Canine displacement, NS No significant difference
The intraclass correlation coefficient (ICC) was also calculated to evaluate random errors (to investigate reliability). The results of this test showed that ICC > 0.999 (Table 2).
Table 2
Interclass correlation coefficients of repeated measurements in the current study (n = 20 casts)
 
ICCs
The confidence interval 95%
f value
P value
Lower
Upper
C.Disp
1.000
0.999
1.000
7131.551
0.000***
C.Disp Canine displacement
*** Significant at P < 0.001

Statistical analysis

The statistical analysis was performed using SPSS for Windows (version 26.0; SPSS, Chicago, USA).
All the data were analyzed on both sides with the Shapiro Wilk test to assess their distribution.
The data for the upper canine retraction variables were subjected to a normal distribution, and a paired sample t test was used.
The data for the upper molar drift variables were subjected to a nonnormal distribution, and a Wilcoxon signed-rank matched pairs test was used.

Results

The final study sample consisted of 17 patients (13 females, 4 males), with an average age of 20.76 ± 2.9 years; these patients were distributed among the same patients on the experimental and control sides. The CONSORT flow diagram of patient recruitment, follow-up, and entry into the data analysis is given in (Fig. 8).
Patient recruitment started in August 2021 and ended in November 2021.
Table 3 results of statistical tests for the difference in upper canine retraction. A significant difference was detected between the control and experimental sides during the first month (0.019 < 0.05), the second month (0.000 < 0.05), and overall duration (0.000 < 0.05). However, the acceleration rates were 12.88%, 38.09%, and 19.16%, respectively. The peak of speed acceleration occurred during the second month (38.09%). At the third and fourth months, there was no significant difference between the control and experimental sides (P > 0.05). The mean differences in upper canine retraction speed between the control and experimental sides are expressed monthly in (Fig. 9).
Table 3
The results of statistical tests for the difference in upper canine retraction between both sides (mm/month)
Time
Variable
n
Mean
Std. deviation
Mean difference
Stander deviation difference
The confidence interval 95%
t value
P value
Lower
Upper
T0-T1
C.RetS.C
17
1.42
0.661
-0.208
0.33
-0.38
-0.04
-2.601
0.019*
C.RetS.E
17
1.63
0.592
T1-T2
C.RetS.C
17
1.17
0.606
-0.721
0.59
-1.03
-0.42
-5.001
0.000***
C.RetS.E
17
1.89
0.507
T2-T3
C.RetS.C
14
1.24
0.613
-0.124
0.42
-0.36
0.12
-1.117
0.2840
(NS)
C.RetS.E
14
1.37
0.493
T3-T4
C.RetS.C
4
1.38
0.35
0.1640
0.65
-0.87
1.19
0.505
0.6490
(NS)
C.RetS.E
4
1.21
0.489
T0-Tf
C.RetS.C
17
1.35
0.41
-0.992
0.16
-0.40
-0.24
-6.64
0.000***
C.RetS.E
17
1.67
0.43
T0-T1: 1st month after upper canine retraction, T1-T2: 2nd month after upper canine retraction, T2-T3: 3rd month after upper canine retraction, T3-T4: 4th month after upper canine retraction, T0-TF: the overall duration
C.RetS.C: Canine retraction speed control side (mm/month)
C.RetS.E: Canine retraction speed experimental side (mm/month)
NS No significant difference
* Significant difference at P < 0.05, *** Significant difference at P < 0.01. Using a paired t test
The results of statistical tests revealed the difference in the speed of upper molar drift between both sides is shown in (Table 4). Moreover, there was no significant difference between the control and experimental sides regarding upper molar drift (P > 0.05) at the 95% confidence level, throughout the overall duration.
Table 4
The results of statistical tests for the difference in upper molar drift between both sides (mm/month)
Time
Variable
n
Minimum
Maximum
Mean
Std. deviation
z
P value
T0-T1
M.DriftS.C
17
0.0
0.96
0.35
0.33
− .594
0.552
(NS)
M.DriftS.E
17
-0.2
0.89
0.28
0.33
T1-T2
M.DriftS.C
17
0.0
1.57
0.52
0.59
− .663
0.508
(NS)
M.DriftS.E
17
-0.3
1.89
0.43
0.64
T2-T3
M.DriftS.C
14
0.0
0.97
0.41
0.35
− .445
0.657
(NS)
M.DriftS.E
14
0.0
1.62
0.35
0.49
T3-T4
M.DriftS.C
4
0.0
0.73
0.23
0.34
-1.342
0.180
(NS)
M.DriftS.E
4
0.0
0.18
0.07
0.09
T0-Tf
M.DriftS.C
17
0.0
1.01
0.41
0.30
− .982
0.326
(NS)
M.DriftS.E
17
0.0
0.81
0.32
0.23
T0-T1: 1st month after upper canine retraction, T1-T2: 2nd month after upper canine retraction, T2-T3: 3rd month after upper canine retraction, T3-T4: 4th month after upper canine retraction, T0-TF: the overall duration
M.DriftS.C: Molar drift speed control side (mm/month)
M.DriftS.E: Molar drift speed experimental side (mm/month)
NS No significant difference, using a Wilcoxon signed-rank matched pairs test was used

Harms

Patients were asked to report any side effects (such as pain, discomfort, swelling, etc.) they suffered at each appointment. None of our patients reported any such complaints.

Discussion

To the best of our knowledge, this is the first trial in the literature evaluating the effectiveness of low-intensity therapy (SMF) in accelerating retraction of the upper canine and in upper molar drift. Thus, the comparison of the current results with those in the literature is limited. The design of the current study follows the most common ones in clinical research which is the randomized controlled clinical trial of split-mouth design, that greatly reduces the impact of individual interventions on treatment efficacy [25].
Premolar extraction was conducted at the beginning of treatment and before appliance fitting to avoid the extraction effect of the regional acceleration phenomenon (RAP) [26].
NiTi closed coil springs were used to retract canines because of the continuous light force they generate and providing better oral health than elastomeric chains [27].
The accelerating magnet device used was placed buccally so that the magnetic field was in the area corresponding to the lateral ligament of the upper canines, because of its proven effectiveness in activities of cells in periodontal tissues by causing faster absorption and deposition of bone [7, 28]. The appliance was comfortable as none of the patients reported any discomfort, besides it did not obstruct the movement of the tongue or speech (which were investigated as a part of the study).
The auxiliary wire carrying the magnet was covered with flexible vacuum-formed sheets 0.5 mm in thickness to secure a smooth surface with soft tissues for the patient’s ultimate comfort and to protect the magnets from corrosion and saliva.
The speed of upper canine retraction and anterior-posterior molar movement, on both the control and experimental sides were evaluated using a digital scanner to perform measurements via a computer program (Exocad - Dental CAD 3.1 Rijeka). The accuracy and reliability of this method were proven previously in the literature [20, 21].
The results of this study showed that the speed of upper canine retraction on the experimental side was significantly greater than that on the control side during the first and second months and during the overall duration of retraction (P value < 0.05). The null hypothesis (H0), which stated that the SMF does not accelerate upper canine retraction, was rejected. These findings are in agreement with the findings of Daskalogiannakis and McLachlan [19], who reported similarly that the SMF is effective at accelerating upper canine retraction. However, there the difference in the rate of acceleration might be due to the different magnets used, which affects the intensity of the magnetic field.
Additionally, our results in the timing of the peak acceleration that occurred during the second month agreed with those of Darendeliler and Sinclair [7] and Sakata et al. [4]. Likewise, their experimental studies on animals showed that the application of SMF can accelerate OTM during the early period.
Similarly, Bhad Patil and Karemore [5] confirmed that PEMF therapy is effective at accelerating upper canine retraction despite differences in the magnetic field applied.
However, the results of the present study did not agree with the findings of Tengku et al. [29], who used different magnetic field intensities (100–170 Gauss) on rats and found that a static magnetic field does not enhance OTM.
The results of this study revealed that the upper molar drift on the experimental side was lower than that on the control side during the overall duration of treatment. However, no significant difference was observed (P > 0.05) between both sides.
These findings suggest that the SMF did not affect upper molar drift during the upper canine retraction phase. Therefore, we accept the null hypothesis (H0). After reviewing the literature, we did not find any study that investigated the speed of upper molar drift accompanying upper canine retraction with the application of a SMF to compare the results of the current study with it.

Limitation

Patient and practitioner blinding was not applicable. Therefore, blinding was applied only for the outcome assessor when recording the casts. This might be considered a limitation of this study, but this was not possible due to the clarity of the magnets; moreover, to ensure the comfort of patients, the placebo device was not applied on the control side.

Conclusion

A low-intensity static magnetic field was effective at accelerating retraction of the upper canines during the first and second months and for the overall duration of the retraction. The difference between the two sides was statistically significant but may not be clinically significant.
The SMF did not affect upper molar drift during the upper canine retraction phase.

Trial registration

The trial was retrospectively registered at the ISRCTN registry (ISRCTN59092624) (31/05/2022). (https://​doi.​org/​10.​1186/​ISRCTN59092624).

Acknowledgements

We would like to acknowledge the participation of the patients.

Declarations

This study was approved by the institutional review board and the ethical review committee of Damascus University (no. 906/22-11-2021). Written informed consent was obtained from each patient.
Not applicable.

Competing interests

The authors declare no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Kacprzak A, Strzecki A. Methods of accelerating orthodontic tooth movement: a review of contemporary literature. Dent Med Probl. 2018;55:197–206.CrossRefPubMed Kacprzak A, Strzecki A. Methods of accelerating orthodontic tooth movement: a review of contemporary literature. Dent Med Probl. 2018;55:197–206.CrossRefPubMed
2.
Zurück zum Zitat Bakdach WMM, Hadad R. Effectiveness of low-level laser therapy in accelerating the orthodontic tooth movement: a systematic review and meta-analysis. Dent Med Probl. 2020;57:73–94.CrossRefPubMed Bakdach WMM, Hadad R. Effectiveness of low-level laser therapy in accelerating the orthodontic tooth movement: a systematic review and meta-analysis. Dent Med Probl. 2020;57:73–94.CrossRefPubMed
3.
Zurück zum Zitat Nimeri G, Kau CH, Abou-Kheir NS, Corona R. Acceleration of tooth movement during orthodontic treatment–a frontier in orthodontics. Prog Orthod. 2013;14:42.CrossRefPubMedPubMedCentral Nimeri G, Kau CH, Abou-Kheir NS, Corona R. Acceleration of tooth movement during orthodontic treatment–a frontier in orthodontics. Prog Orthod. 2013;14:42.CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Sakata M, Yamamoto Y, Imamura N, Nakata S, Nakasima A. The effects of a static magnetic field on orthodontic tooth movement. J Orthod. 2008;35:249–54.CrossRefPubMed Sakata M, Yamamoto Y, Imamura N, Nakata S, Nakasima A. The effects of a static magnetic field on orthodontic tooth movement. J Orthod. 2008;35:249–54.CrossRefPubMed
5.
Zurück zum Zitat Bhad Patil WA, Karemore AA. Efficacy of pulsed electromagnetic field in reducing treatment time: a clinical investigation. Am J Orthod Dentofac Orthop. 2022;161:652–8.CrossRef Bhad Patil WA, Karemore AA. Efficacy of pulsed electromagnetic field in reducing treatment time: a clinical investigation. Am J Orthod Dentofac Orthop. 2022;161:652–8.CrossRef
6.
Zurück zum Zitat Showkatbakhsh R, Jamilian A, Showkatbakhsh M. The effect of pulsed electromagnetic fields on the acceleration of tooth movement. World J Orthod. 2010;11:e52–6.PubMed Showkatbakhsh R, Jamilian A, Showkatbakhsh M. The effect of pulsed electromagnetic fields on the acceleration of tooth movement. World J Orthod. 2010;11:e52–6.PubMed
7.
Zurück zum Zitat Darendeliler MA, Sinclair PM, Kusy RP. The effects of samarium-cobalt magnets and pulsed electromagnetic fields on tooth movement. Am J Orthod Dentofac Orthop. 1995;107:578–88.CrossRef Darendeliler MA, Sinclair PM, Kusy RP. The effects of samarium-cobalt magnets and pulsed electromagnetic fields on tooth movement. Am J Orthod Dentofac Orthop. 1995;107:578–88.CrossRef
8.
Zurück zum Zitat Huang H, Williams RC, Kyrkanides S. Accelerated orthodontic tooth movement: molecular mechanisms. Am J Orthod Dentofac Orthop. 2014;146:620–32.CrossRef Huang H, Williams RC, Kyrkanides S. Accelerated orthodontic tooth movement: molecular mechanisms. Am J Orthod Dentofac Orthop. 2014;146:620–32.CrossRef
9.
Zurück zum Zitat Ishida Y, Kuwajima Y, Lee C, Ogawa K, Da Silva JD, Ishikawa-Nagai S. Effect of Magnet position on tipping and Bodily Tooth Movement in Magnetic Force-Driven Orthodontics. Mater. 2020;13:1–2.CrossRef Ishida Y, Kuwajima Y, Lee C, Ogawa K, Da Silva JD, Ishikawa-Nagai S. Effect of Magnet position on tipping and Bodily Tooth Movement in Magnetic Force-Driven Orthodontics. Mater. 2020;13:1–2.CrossRef
10.
Zurück zum Zitat Kuwajima Y, Ishida Y, Lee C, Mayama H, Satoh K, Ishikawa-Nagai S. 3D digital analysis of magnetic force-driven orthodontic tooth movement. Heliyon. 2019;5:e02861.CrossRefPubMedPubMedCentral Kuwajima Y, Ishida Y, Lee C, Mayama H, Satoh K, Ishikawa-Nagai S. 3D digital analysis of magnetic force-driven orthodontic tooth movement. Heliyon. 2019;5:e02861.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Ravindran KV. Role of magnets in orthodontics—a review. Indian J Dent. 2011;2:147–55.CrossRef Ravindran KV. Role of magnets in orthodontics—a review. Indian J Dent. 2011;2:147–55.CrossRef
12.
Zurück zum Zitat Phelan A, Tarraf NE, Taylor P, Hönscheid R, Drescher D, Baccetti T, et al. Skeletal and dental outcomes of a new magnetic functional appliance, the Sydney Magnoglide, in Class II correction. Am J Orthod Dentofac Orthop. 2012;141:759–72.CrossRef Phelan A, Tarraf NE, Taylor P, Hönscheid R, Drescher D, Baccetti T, et al. Skeletal and dental outcomes of a new magnetic functional appliance, the Sydney Magnoglide, in Class II correction. Am J Orthod Dentofac Orthop. 2012;141:759–72.CrossRef
13.
Zurück zum Zitat Zhao N, Feng J, Hu Z, Chen R, Shen G. Effects of a novel magnetic orthopedic appliance (MOA-III) on the dentofacial complex in mild to moderate skeletal class III children. Head Face Med. 2015;11:34.CrossRefPubMedPubMedCentral Zhao N, Feng J, Hu Z, Chen R, Shen G. Effects of a novel magnetic orthopedic appliance (MOA-III) on the dentofacial complex in mild to moderate skeletal class III children. Head Face Med. 2015;11:34.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Prasad M, Manoj-Kumar M, Gowri sankar S, Chaitanya N, Reddy V, Nettam V. Clinical evaluation of neodymium-iron-boron (Ne2Fe14B) rare earth magnets in the treatment of mid line diastemas. J Clin Exp Dent. 2016;8:1–3. Prasad M, Manoj-Kumar M, Gowri sankar S, Chaitanya N, Reddy V, Nettam V. Clinical evaluation of neodymium-iron-boron (Ne2Fe14B) rare earth magnets in the treatment of mid line diastemas. J Clin Exp Dent. 2016;8:1–3.
15.
Zurück zum Zitat Chen W-T, Lin G-B, Lin S-H, Lu C-H, Hsieh C-H, Ma B-L, et al. Static magnetic field enhances the anticancer efficacy of capsaicin on HepG2 cells via capsaicin receptor TRPV1. PLoS ONE. 2018;13:e0191078.CrossRefPubMedPubMedCentral Chen W-T, Lin G-B, Lin S-H, Lu C-H, Hsieh C-H, Ma B-L, et al. Static magnetic field enhances the anticancer efficacy of capsaicin on HepG2 cells via capsaicin receptor TRPV1. PLoS ONE. 2018;13:e0191078.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Ghodbane S, Lahbib A, Sakly M, Abdelmelek H. Bioeffects of static magnetic fields: oxidative stress, genotoxic effects, and cancer studies. Biomed Res Int. 2013;2013:602987.CrossRefPubMedPubMedCentral Ghodbane S, Lahbib A, Sakly M, Abdelmelek H. Bioeffects of static magnetic fields: oxidative stress, genotoxic effects, and cancer studies. Biomed Res Int. 2013;2013:602987.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Fan Z, Hu P, Xiang L, Liu Y, He R, Lu T. A static magnetic field inhibits the Migration and Telomerase function of mouse breast Cancer cells. Biomed Res Int. 2020;2020:7472618.CrossRefPubMedPubMedCentral Fan Z, Hu P, Xiang L, Liu Y, He R, Lu T. A static magnetic field inhibits the Migration and Telomerase function of mouse breast Cancer cells. Biomed Res Int. 2020;2020:7472618.CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Daskalogiannakis J, McLachlan KR. Canine retraction with rare earth magnets: an investigation into the validity of the constant force hypothesis. Am J Orthod Dentofac Orthop. 1996;109:489–95.CrossRef Daskalogiannakis J, McLachlan KR. Canine retraction with rare earth magnets: an investigation into the validity of the constant force hypothesis. Am J Orthod Dentofac Orthop. 1996;109:489–95.CrossRef
20.
Zurück zum Zitat Sousa MV, Vasconcelos EC, Janson G, Garib D, Pinzan A. Accuracy and reproducibility of 3-dimensional digital model measurements. Am J Orthod Dentofac Orthop. 2012;142:269–73.CrossRef Sousa MV, Vasconcelos EC, Janson G, Garib D, Pinzan A. Accuracy and reproducibility of 3-dimensional digital model measurements. Am J Orthod Dentofac Orthop. 2012;142:269–73.CrossRef
21.
Zurück zum Zitat Lemos LS, Rebello IM, Vogel CJ, Barbosa MC. Reliability of measurements made on scanned cast models using the 3 shape R 700 scanner. Dentomaxillofac Radiol. 2015;44:20140337.CrossRefPubMedPubMedCentral Lemos LS, Rebello IM, Vogel CJ, Barbosa MC. Reliability of measurements made on scanned cast models using the 3 shape R 700 scanner. Dentomaxillofac Radiol. 2015;44:20140337.CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Czarnota J, Hey J, Fuhrmann R. Measurements using orthodontic analysis software on digital models obtained by 3D scans of plaster casts: intrarater reliability and validity. J Orofac Orthop. 2016;77:22–30.CrossRefPubMed Czarnota J, Hey J, Fuhrmann R. Measurements using orthodontic analysis software on digital models obtained by 3D scans of plaster casts: intrarater reliability and validity. J Orofac Orthop. 2016;77:22–30.CrossRefPubMed
23.
Zurück zum Zitat Li S, Xia Z, Liu SS, Eckert G, Chen J. Three-dimensional canine displacement patterns in response to translation and controlled tipping retraction strategies. Angle Orthod. 2015;85:18–25.CrossRefPubMed Li S, Xia Z, Liu SS, Eckert G, Chen J. Three-dimensional canine displacement patterns in response to translation and controlled tipping retraction strategies. Angle Orthod. 2015;85:18–25.CrossRefPubMed
24.
Zurück zum Zitat Teng F, Du FY, Chen HZ, Jiang RP, Xu TM. Three-dimensional analysis of the physiologic drift of adjacent teeth following maxillary first premolar extractions. Sci Rep. 2019;9:14549.CrossRefPubMedPubMedCentral Teng F, Du FY, Chen HZ, Jiang RP, Xu TM. Three-dimensional analysis of the physiologic drift of adjacent teeth following maxillary first premolar extractions. Sci Rep. 2019;9:14549.CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Lesaffre E, Philstrom B, Needleman I, Worthington H. The design and analysis of split-mouth studies: what statisticians and clinicians should know. Stat Med. 2009;28:3470–82.CrossRefPubMed Lesaffre E, Philstrom B, Needleman I, Worthington H. The design and analysis of split-mouth studies: what statisticians and clinicians should know. Stat Med. 2009;28:3470–82.CrossRefPubMed
26.
Zurück zum Zitat Azeem M, Afzal A, Jawa SA, Haq AU, Khan M, Akram H. Effectiveness of electric toothbrush as vibration method on orthodontic tooth movement: a split-mouth study. Dent Press J Orthod. 2019;24:49–55.CrossRef Azeem M, Afzal A, Jawa SA, Haq AU, Khan M, Akram H. Effectiveness of electric toothbrush as vibration method on orthodontic tooth movement: a split-mouth study. Dent Press J Orthod. 2019;24:49–55.CrossRef
28.
Zurück zum Zitat Stark TM, Sinclair PM. Effect of pulsed electromagnetic fields on orthodontic tooth movement. Am J Orthod Dentofac Orthop. 1987;91:91–104.CrossRef Stark TM, Sinclair PM. Effect of pulsed electromagnetic fields on orthodontic tooth movement. Am J Orthod Dentofac Orthop. 1987;91:91–104.CrossRef
29.
Zurück zum Zitat Tengku B, Joseph B, Harbrow D, Taverne A, Symons A. Effect of a static magnetic field on orthodontic tooth movement in the rat. Eur J Orthod. 2000;22:475–87.CrossRefPubMed Tengku B, Joseph B, Harbrow D, Taverne A, Symons A. Effect of a static magnetic field on orthodontic tooth movement in the rat. Eur J Orthod. 2000;22:475–87.CrossRefPubMed
Metadaten
Titel
Effectiveness of a low-intensity static magnetic field in accelerating upper canine retraction: a randomized controlled clinical trial
verfasst von
Nataly N. Alqaisi
Rania A. Haddad
Hani M. Amasha
Publikationsdatum
01.12.2024
Verlag
BioMed Central
Erschienen in
BMC Oral Health / Ausgabe 1/2024
Elektronische ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-024-04212-x

Weitere Artikel der Ausgabe 1/2024

BMC Oral Health 1/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.