23.07.2020 | Original Article

Evidence-Based Efficacy of High-Intensity Focused Ultrasound (HIFU) in Aesthetic Body Contouring

verfasst von: Bishara S. Atiyeh, Fadl Chahine

Erschienen in: Aesthetic Plastic Surgery | Ausgabe 2/2021

Einloggen, um Zugang zu erhalten

Abstract

Being profitable procedures with little disposable costs, a number of noninvasive technologies have gained much popularity in recent years and are permeating the aesthetic marketplace. High-intensity focused ultrasound (HIFU) when focused at a targeted depth of 1.1 to 1.6 cm within subcutaneous tissue raises local tissue temperature at the focal point resulting in almost immediate cell death without damage to the surrounding tissues. Despite having gained popularity, little information is available regarding HIFU use for the treatment of localized fat and aesthetic body sculpturing. The current literature review is intended to investigate evidence-based efficacy of HIFU in aesthetic body contouring.

Level of Evidence IV

This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.​springer.​com/​00266.
Literatur
1.
Zurück zum Zitat Fonseca VM, Campos PS, Certo TF, de-Faria LT, Juliano PB, Cintra DE, Liebano RE, da Silva C, Guidi RM, Sant'Ana E (2018) Efficacy and safety of noninvasive focused ultrasound for treatment of subcutaneous adiposity in healthy women. J Cosmet Laser Ther 20(6):341–350PubMed Fonseca VM, Campos PS, Certo TF, de-Faria LT, Juliano PB, Cintra DE, Liebano RE, da Silva C, Guidi RM, Sant'Ana E (2018) Efficacy and safety of noninvasive focused ultrasound for treatment of subcutaneous adiposity in healthy women. J Cosmet Laser Ther 20(6):341–350PubMed
2.
Zurück zum Zitat Fatemi A, Kane MAC (2010) High-intensity focused ultrasound effectively reduces waist circumference by ablating adipose tissue from the abdomen and flanks: a retrospective case series. Aesth Plast Surg 34:577–582 Fatemi A, Kane MAC (2010) High-intensity focused ultrasound effectively reduces waist circumference by ablating adipose tissue from the abdomen and flanks: a retrospective case series. Aesth Plast Surg 34:577–582
3.
Zurück zum Zitat Mazzoni D, Lin MJ, Dubin DP, Khorasani H (2019) Review of non-invasive body contouring devices for fat reduction, skin tightening and muscle definition. Austr J Dermatol 60(4):278–283 Mazzoni D, Lin MJ, Dubin DP, Khorasani H (2019) Review of non-invasive body contouring devices for fat reduction, skin tightening and muscle definition. Austr J Dermatol 60(4):278–283
4.
Zurück zum Zitat Shek SY, Yeung CK, Chan JC, Chan HH (2014) Efficacy of high-intensity focused ultrasonography for noninvasive body sculpting in Chinese patients. Lasers Surg Med 46(4):263–269PubMed Shek SY, Yeung CK, Chan JC, Chan HH (2014) Efficacy of high-intensity focused ultrasonography for noninvasive body sculpting in Chinese patients. Lasers Surg Med 46(4):263–269PubMed
5.
Zurück zum Zitat Halachmi S, Lapidoth M (2013) Safety and tolerability of a focused ultrasound device for treatment of adipose tissue in subjects undergoing abdominoplasty, a placebo control pilot study. Dermatol Surg 39:752–754PubMed Halachmi S, Lapidoth M (2013) Safety and tolerability of a focused ultrasound device for treatment of adipose tissue in subjects undergoing abdominoplasty, a placebo control pilot study. Dermatol Surg 39:752–754PubMed
6.
Zurück zum Zitat Capla JM, Rubin JP (2011) Discussion: randomized sham-controlled trial to evaluate the safety and effectiveness of a high-intensity focused ultrasound device for noninvasive body sculpting. Plast. Reconstr Surg. 128(263):2011 Capla JM, Rubin JP (2011) Discussion: randomized sham-controlled trial to evaluate the safety and effectiveness of a high-intensity focused ultrasound device for noninvasive body sculpting. Plast. Reconstr Surg. 128(263):2011
7.
Zurück zum Zitat Kennedy J, Verne S, Griffith R, Falto-Aizpurua L, Nouri K (2015) Non-invasive subcutaneous fat reduction: a review. J Eur Assoc Dermatol Venereal 29:1679–1688 Kennedy J, Verne S, Griffith R, Falto-Aizpurua L, Nouri K (2015) Non-invasive subcutaneous fat reduction: a review. J Eur Assoc Dermatol Venereal 29:1679–1688
8.
Zurück zum Zitat Greenhaw BN, Cook J (2015) Painful subcutaneous fibrosis: a complication after high-intensity focused ultrasound for lipolysis. Dermatol Surg 41(6):744–746PubMed Greenhaw BN, Cook J (2015) Painful subcutaneous fibrosis: a complication after high-intensity focused ultrasound for lipolysis. Dermatol Surg 41(6):744–746PubMed
9.
Zurück zum Zitat Nassab R (2015) The evidence behind noninvasive body contouring devices. Aesthet Surg J 35(3):279–293PubMed Nassab R (2015) The evidence behind noninvasive body contouring devices. Aesthet Surg J 35(3):279–293PubMed
10.
Zurück zum Zitat Juhász M, Korta D, Mesinkovska NA (2018) A review of the use of ultrasound for skin tightening, body contouring, and cellulite reduction in dermatology. Dermatol Surg 44(7):949–963PubMed Juhász M, Korta D, Mesinkovska NA (2018) A review of the use of ultrasound for skin tightening, body contouring, and cellulite reduction in dermatology. Dermatol Surg 44(7):949–963PubMed
11.
Zurück zum Zitat Hong JY, Ko EJ, Choi SY, Kim SY, Kim BJ (2020) Efficacy and safety of high-intensity focused ultrasound for noninvasive abdominal subcutaneous fat reduction. Dermatol Surg 46(2):213–219PubMed Hong JY, Ko EJ, Choi SY, Kim SY, Kim BJ (2020) Efficacy and safety of high-intensity focused ultrasound for noninvasive abdominal subcutaneous fat reduction. Dermatol Surg 46(2):213–219PubMed
12.
Zurück zum Zitat Lee S, Kim HJ, Park HJ, Kim HM, Lee SH, Cho SB (2017) Morphometric analysis of high-intensity focused ultrasound-induced lipolysis on cadaveric abdominal and thigh skin. Lasers Med Sci 32(5):1143–1151PubMed Lee S, Kim HJ, Park HJ, Kim HM, Lee SH, Cho SB (2017) Morphometric analysis of high-intensity focused ultrasound-induced lipolysis on cadaveric abdominal and thigh skin. Lasers Med Sci 32(5):1143–1151PubMed
13.
Zurück zum Zitat Tadisina KK, Patel MN, Chopra K (2013) High-intensity focused ultrasound in aesthetic plastic surgery. www.ePlasty.com, Interesting Case, August 8, 2013 Tadisina KK, Patel MN, Chopra K (2013) High-intensity focused ultrasound in aesthetic plastic surgery. www.​ePlasty.​com, Interesting Case, August 8, 2013
14.
Zurück zum Zitat Alizadeh Z, Halabchi F, Mazaheri R, Abolhasani M, Tabesh M (2016) Review of the mechanisms and effects of noninvasive body contouring devices on cellulite and subcutaneous. Fat Int J Endocrinol Metab 14(4):e36727PubMed Alizadeh Z, Halabchi F, Mazaheri R, Abolhasani M, Tabesh M (2016) Review of the mechanisms and effects of noninvasive body contouring devices on cellulite and subcutaneous. Fat Int J Endocrinol Metab 14(4):e36727PubMed
15.
Zurück zum Zitat Robinson DM, Kaminer MS, Baumann L, Burns AJ, Brauer JA, Jewell M, Lupin M, Narurkar VA, Struck SK, Hledik J, Dover JS (2014) High-intensity focused ultrasound for the reduction of subcutaneous adipose tissue using multiple treatment techniques. Dermatol Surg 40(6):641–651PubMed Robinson DM, Kaminer MS, Baumann L, Burns AJ, Brauer JA, Jewell M, Lupin M, Narurkar VA, Struck SK, Hledik J, Dover JS (2014) High-intensity focused ultrasound for the reduction of subcutaneous adipose tissue using multiple treatment techniques. Dermatol Surg 40(6):641–651PubMed
16.
Zurück zum Zitat Jewell M, Solish N, Desilets C (2011) Noninvasive body sculpting technologies with an emphasis on high-intensity focused ultrasound. Aesthet Plast Surg 35:901–912 Jewell M, Solish N, Desilets C (2011) Noninvasive body sculpting technologies with an emphasis on high-intensity focused ultrasound. Aesthet Plast Surg 35:901–912
17.
Zurück zum Zitat Nazanin S, Michael K (2013) New waves for fat reduction: high-intensity focused ultrasound. Semin Cutan Med Surg 32(1):26–30 Nazanin S, Michael K (2013) New waves for fat reduction: high-intensity focused ultrasound. Semin Cutan Med Surg 32(1):26–30
18.
Zurück zum Zitat Teitelbaum SA, Burns JL, Kubota J, Matsuda H et al (2007) Noninvasive body contouring by focused ultrasound: safety and efficacy of the contour I device in a multicenter, controlled, clinical study. Plast Reconstr Surg 120:779–789PubMed Teitelbaum SA, Burns JL, Kubota J, Matsuda H et al (2007) Noninvasive body contouring by focused ultrasound: safety and efficacy of the contour I device in a multicenter, controlled, clinical study. Plast Reconstr Surg 120:779–789PubMed
19.
Zurück zum Zitat Coleman WP III, Coleman W IV, Weiss RA, Kenkel JM, Ad-El DD, Amir R (2017) A multicenter controlled study to evaluate multiple treatments with nonthermal focused ultrasound for noninvasive fat reduction. Dermatol Surg 43(1):50–57PubMed Coleman WP III, Coleman W IV, Weiss RA, Kenkel JM, Ad-El DD, Amir R (2017) A multicenter controlled study to evaluate multiple treatments with nonthermal focused ultrasound for noninvasive fat reduction. Dermatol Surg 43(1):50–57PubMed
20.
Zurück zum Zitat Pyo H, Park S, Jung JH, Kim SM, Kang HW (2017) Quantitative investigations on thermal response of adipose tissue to focused ultrasonic energy. Jpn J Appl Phys 56(7):07JF03 Pyo H, Park S, Jung JH, Kim SM, Kang HW (2017) Quantitative investigations on thermal response of adipose tissue to focused ultrasonic energy. Jpn J Appl Phys 56(7):07JF03
21.
Zurück zum Zitat Fatemi A, Michael A, Kane C (2010) High-intensity focused ultrasound effectively reduces waist circumference by ablating adipose tissue from the abdomen and flanks: a retrospective case series. Aesthet Plast Surg 34:577–582 Fatemi A, Michael A, Kane C (2010) High-intensity focused ultrasound effectively reduces waist circumference by ablating adipose tissue from the abdomen and flanks: a retrospective case series. Aesthet Plast Surg 34:577–582
22.
Zurück zum Zitat Ko EJ, Kwon HJ, Kwon TR, Choi SY, Yoo KH, Kim BJ (2018) High-intensity focused ultrasound treatment after cryolipolysis may be used to reduce pain: Two case report. Dermatol Ther 31(4):e12604PubMed Ko EJ, Kwon HJ, Kwon TR, Choi SY, Yoo KH, Kim BJ (2018) High-intensity focused ultrasound treatment after cryolipolysis may be used to reduce pain: Two case report. Dermatol Ther 31(4):e12604PubMed
23.
Zurück zum Zitat Guth F, Bitencourt S, Bedinot C, Sinigaglia G, Tassinary JAF (2018) Immediate effect and safety of HIFU single treatment for male subcutaneous fat reduction. J Cosmet Dermatol 17(3):385–389PubMed Guth F, Bitencourt S, Bedinot C, Sinigaglia G, Tassinary JAF (2018) Immediate effect and safety of HIFU single treatment for male subcutaneous fat reduction. J Cosmet Dermatol 17(3):385–389PubMed
24.
Zurück zum Zitat Gadsden E, Aguilar MT, Smoller BR, Jewell ML (2011) Evaluation of a novel high-intensity focused ultrasound device for ablating subcutaneous adipose tissue for non invasive body contouring: safety studies in human volunteers. Aesthet Surg J 31(4):401–410PubMed Gadsden E, Aguilar MT, Smoller BR, Jewell ML (2011) Evaluation of a novel high-intensity focused ultrasound device for ablating subcutaneous adipose tissue for non invasive body contouring: safety studies in human volunteers. Aesthet Surg J 31(4):401–410PubMed
25.
Zurück zum Zitat Solish N, Lin X, Axford-Gatley RA et al (2012) A randomized, single-blind, postmarketing study of multiple energy levels of high-intensity focused ultrasound for noninvasive body sculpting. Dermatol Surg 38:58–67PubMed Solish N, Lin X, Axford-Gatley RA et al (2012) A randomized, single-blind, postmarketing study of multiple energy levels of high-intensity focused ultrasound for noninvasive body sculpting. Dermatol Surg 38:58–67PubMed
26.
Zurück zum Zitat Shalom A, Wiser I, Brawer S, Azhari H (2013) Safety and tolerability of a focused ultrasound device for treatment of adipose tissue in subjects undergoing abdominoplasty: a placebo-control pilot study. Dermatol Surg 39(5):744–751PubMed Shalom A, Wiser I, Brawer S, Azhari H (2013) Safety and tolerability of a focused ultrasound device for treatment of adipose tissue in subjects undergoing abdominoplasty: a placebo-control pilot study. Dermatol Surg 39(5):744–751PubMed
27.
Zurück zum Zitat Jewell ML, Weiss RA, Baxter RA, Cox SE, Dover JS, Donofrio LM, Glogau RG, Kane MC, Martin P, Lawrence ID, Schles-singer J (2012) Safety and tolerability of high-intensity focused ultrasonography for noninvasive body sculpting: 24-week data from a randomized, sham-controlled study. Aesthet Surg J 32(7):868–876PubMed Jewell ML, Weiss RA, Baxter RA, Cox SE, Dover JS, Donofrio LM, Glogau RG, Kane MC, Martin P, Lawrence ID, Schles-singer J (2012) Safety and tolerability of high-intensity focused ultrasonography for noninvasive body sculpting: 24-week data from a randomized, sham-controlled study. Aesthet Surg J 32(7):868–876PubMed
28.
Zurück zum Zitat Jewell ML, Baxter RA, Cox SE, Donofrio LM et al (2011) Randomized sham-controlled trial to evaluate the safety and effectiveness of a high-intensity focused ultrasound device for noninvasive body sculpting. Plast Reconstr Surg 128:253PubMed Jewell ML, Baxter RA, Cox SE, Donofrio LM et al (2011) Randomized sham-controlled trial to evaluate the safety and effectiveness of a high-intensity focused ultrasound device for noninvasive body sculpting. Plast Reconstr Surg 128:253PubMed
29.
Zurück zum Zitat Fatemi A (2009) High-intensity focused ultrasound effectively reduces adipose tissue. Semin Cutan Med Surg 28:257–262PubMed Fatemi A (2009) High-intensity focused ultrasound effectively reduces adipose tissue. Semin Cutan Med Surg 28:257–262PubMed
30.
Zurück zum Zitat Otto MJ (2016) The safety and efficacy of thermal lipolysis of adipose tissue via ultrasound for circumference reduction: an open label, single-arm exploratory study. Lasers Surg Med 48:734–741PubMed Otto MJ (2016) The safety and efficacy of thermal lipolysis of adipose tissue via ultrasound for circumference reduction: an open label, single-arm exploratory study. Lasers Surg Med 48:734–741PubMed
31.
Zurück zum Zitat Sebo P, François RH, Haller DM (2017) Accuracy of anthropometric measurements by general practitioners in overweight and obese patients. BMC Obes 4:23PubMedPubMedCentral Sebo P, François RH, Haller DM (2017) Accuracy of anthropometric measurements by general practitioners in overweight and obese patients. BMC Obes 4:23PubMedPubMedCentral
32.
Zurück zum Zitat Sebo P, Haller DM, Pechère-Bertschi A, Bovier P, Herrmann FR (2015) Accuracy of doctors’ anthropometric measurements in general practice. Swiss Med Wkly 145:w14115PubMed Sebo P, Haller DM, Pechère-Bertschi A, Bovier P, Herrmann FR (2015) Accuracy of doctors’ anthropometric measurements in general practice. Swiss Med Wkly 145:w14115PubMed
33.
Zurück zum Zitat Verweij LM, Terwee CB, Proper KI, Hulshof CTJ, van Mechelen W (2013) Measurement error of waist circumference: gaps in knowledge. Public Health Nutr 16:281–288PubMed Verweij LM, Terwee CB, Proper KI, Hulshof CTJ, van Mechelen W (2013) Measurement error of waist circumference: gaps in knowledge. Public Health Nutr 16:281–288PubMed
34.
Zurück zum Zitat Ma W-Y, Yang C-Y, Shih S-R, Hsieh H-J et al (2013) Measurement of Waist Circumference Midabdominal or iliac crest? Diabetes Care 36(6):1660–1666PubMedPubMedCentral Ma W-Y, Yang C-Y, Shih S-R, Hsieh H-J et al (2013) Measurement of Waist Circumference Midabdominal or iliac crest? Diabetes Care 36(6):1660–1666PubMedPubMedCentral
35.
Zurück zum Zitat Lim Y, Park JH, Kang SH, Lee JH (2018) Highly-focused ultrasound in non-invasive body contouring: long-term follow-up in Korean patients. Dermatol Ther 31(5):e12664PubMed Lim Y, Park JH, Kang SH, Lee JH (2018) Highly-focused ultrasound in non-invasive body contouring: long-term follow-up in Korean patients. Dermatol Ther 31(5):e12664PubMed
36.
Zurück zum Zitat Heymsfield SB, Brianna Bourgeois B, Ng BK, Sommer MJ, Li X, Shepherd JA (2018) Digital anthropometry: a critical review. Eur J Clin Nutr 72(5):680–687PubMedPubMedCentral Heymsfield SB, Brianna Bourgeois B, Ng BK, Sommer MJ, Li X, Shepherd JA (2018) Digital anthropometry: a critical review. Eur J Clin Nutr 72(5):680–687PubMedPubMedCentral
37.
Zurück zum Zitat Sobhiyeh S, Dechenaud M, Dunkel A, LaBorde M, Kennedy S, Shepherd J, Heymsfield S, Wolenski P (2019) Hole filling in 3D scans for digital anthropometric applications. Conf Proc IEEE Eng Med Biol Soc 2019:2752–2757PubMedCentral Sobhiyeh S, Dechenaud M, Dunkel A, LaBorde M, Kennedy S, Shepherd J, Heymsfield S, Wolenski P (2019) Hole filling in 3D scans for digital anthropometric applications. Conf Proc IEEE Eng Med Biol Soc 2019:2752–2757PubMedCentral
38.
Zurück zum Zitat Kroh A, Peters F, Alizai P, Schmitz S, Hölzle F, Neumann UP, Ulmer FT, Modabber A (2020) 3D optical imaging as a new tool for the objective evaluation of body shape changes after bariatric surgery. Obes Surg 30(5):1866–1873PubMedPubMedCentral Kroh A, Peters F, Alizai P, Schmitz S, Hölzle F, Neumann UP, Ulmer FT, Modabber A (2020) 3D optical imaging as a new tool for the objective evaluation of body shape changes after bariatric surgery. Obes Surg 30(5):1866–1873PubMedPubMedCentral
39.
Zurück zum Zitat Daanen HAM, Psikuta A (2018) 3D body scanning. In: Nayak R, Padhye R (eds) Automation in Garment manufacturing, the textile institute Book series. Woodhead Publishing, Cambridge, pp 237–252 Daanen HAM, Psikuta A (2018) 3D body scanning. In: Nayak R, Padhye R (eds) Automation in Garment manufacturing, the textile institute Book series. Woodhead Publishing, Cambridge, pp 237–252
40.
Zurück zum Zitat Alexander H, Miller DL (1979) Determining skin thickness with pulsed ultrasound. J Invest Dermatol 72:17–19PubMed Alexander H, Miller DL (1979) Determining skin thickness with pulsed ultrasound. J Invest Dermatol 72:17–19PubMed
41.
Zurück zum Zitat Weits T, van der Beek EJ, Wedel M (1986) Comparison of ultrasound and skinfold caliper measurement of subcutaneous fat tissue. Int J Obes 10(3):161–168PubMed Weits T, van der Beek EJ, Wedel M (1986) Comparison of ultrasound and skinfold caliper measurement of subcutaneous fat tissue. Int J Obes 10(3):161–168PubMed
42.
Zurück zum Zitat Black D, Vora J, Hayward M, Marks R (1988) Measurement of subcutaneous fat thickness with high frequency pulsed ultrasound: comparisons with a caliper and a radiographic technique. Clin Phys Physiol Meas 9(1):57–64PubMed Black D, Vora J, Hayward M, Marks R (1988) Measurement of subcutaneous fat thickness with high frequency pulsed ultrasound: comparisons with a caliper and a radiographic technique. Clin Phys Physiol Meas 9(1):57–64PubMed
43.
Zurück zum Zitat Klassen AF, Cano SJ, Alderman A, East C et al (2016) Self-report scales to measure expectations and appearance-related psychosocial distress in patients seeking cosmetic treatments. Aesthet Surg J 36(9):1068–1078PubMedPubMedCentral Klassen AF, Cano SJ, Alderman A, East C et al (2016) Self-report scales to measure expectations and appearance-related psychosocial distress in patients seeking cosmetic treatments. Aesthet Surg J 36(9):1068–1078PubMedPubMedCentral
44.
Zurück zum Zitat Reavey PL, Klassen AF, Cano SJ, McCarthy C et al (2011) Measuring quality of life and patient satisfaction after body contouring: a systematic review of patient-reported outcome measures. Aesthet Surg J 31(7):807–813PubMed Reavey PL, Klassen AF, Cano SJ, McCarthy C et al (2011) Measuring quality of life and patient satisfaction after body contouring: a systematic review of patient-reported outcome measures. Aesthet Surg J 31(7):807–813PubMed
45.
Zurück zum Zitat Gupta P, Srivastava Atul (2018) Numerical analysis of thermal response of tissues subjected to high intensity focused ultrasound. Int J Hypertherm 35(1):419–434 Gupta P, Srivastava Atul (2018) Numerical analysis of thermal response of tissues subjected to high intensity focused ultrasound. Int J Hypertherm 35(1):419–434
46.
Zurück zum Zitat Kwon TR, Im S, Jang YJ, Oh CT, Choi EJ, Jung SJ, Hong H, Choi YS, Choi SY, Kim YS, Kim BJ (2017) Improved methods for evaluating pre-clinical and histological effects of subcutaneous fat reduction using high-intensity focused ultrasound in a porcine model. Skin Res Technol 23(2):194–201PubMed Kwon TR, Im S, Jang YJ, Oh CT, Choi EJ, Jung SJ, Hong H, Choi YS, Choi SY, Kim YS, Kim BJ (2017) Improved methods for evaluating pre-clinical and histological effects of subcutaneous fat reduction using high-intensity focused ultrasound in a porcine model. Skin Res Technol 23(2):194–201PubMed
47.
Zurück zum Zitat Weiss RA (2013) Noninvasive radio frequency for skin tightening and body contouring. Semin Cutan Med Surg 32(1):9–17PubMed Weiss RA (2013) Noninvasive radio frequency for skin tightening and body contouring. Semin Cutan Med Surg 32(1):9–17PubMed
48.
Zurück zum Zitat Jewell ML, Desilets C, Smoller BR (2011) Evaluation of a novel high-intensity focused ultrasound device: preclinical studies in a porcine model. Aesthet Surg J 31(4):429–434PubMed Jewell ML, Desilets C, Smoller BR (2011) Evaluation of a novel high-intensity focused ultrasound device: preclinical studies in a porcine model. Aesthet Surg J 31(4):429–434PubMed
50.
Zurück zum Zitat Ackley BJ, Swan BA, Ladwig G, Tucker S (2008) Evidence-based nursing guidelines: medical-surgical interventions. Mosby Elsevier, St. Louis Ackley BJ, Swan BA, Ladwig G, Tucker S (2008) Evidence-based nursing guidelines: medical-surgical interventions. Mosby Elsevier, St. Louis
Metadaten
Titel
Evidence-Based Efficacy of High-Intensity Focused Ultrasound (HIFU) in Aesthetic Body Contouring
verfasst von
Bishara S. Atiyeh
Fadl Chahine
Publikationsdatum
23.07.2020
Verlag
Springer US
Erschienen in
Aesthetic Plastic Surgery / Ausgabe 2/2021
Print ISSN: 0364-216X
Elektronische ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-020-01863-3

Weitere Artikel der Ausgabe 2/2021

Aesthetic Plastic Surgery 2/2021 Zur Ausgabe

Echinokokkose medikamentös behandeln oder operieren?

06.05.2024 DCK 2024 Kongressbericht

Die Therapie von Echinokokkosen sollte immer in spezialisierten Zentren erfolgen. Eine symptomlose Echinokokkose kann – egal ob von Hunde- oder Fuchsbandwurm ausgelöst – konservativ erfolgen. Wenn eine Op. nötig ist, kann es sinnvoll sein, vorher Zysten zu leeren und zu desinfizieren. 

Wie sieht der OP der Zukunft aus?

04.05.2024 DCK 2024 Kongressbericht

Der OP in der Zukunft wird mit weniger Personal auskommen – nicht, weil die Technik das medizinische Fachpersonal verdrängt, sondern weil der Personalmangel es nötig macht.

Umsetzung der POMGAT-Leitlinie läuft

03.05.2024 DCK 2024 Kongressbericht

Seit November 2023 gibt es evidenzbasierte Empfehlungen zum perioperativen Management bei gastrointestinalen Tumoren (POMGAT) auf S3-Niveau. Vieles wird schon entsprechend der Empfehlungen durchgeführt. Wo es im Alltag noch hapert, zeigt eine Umfrage in einem Klinikverbund.

Recycling im OP – möglich, aber teuer

02.05.2024 DCK 2024 Kongressbericht

Auch wenn sich Krankenhäuser nachhaltig und grün geben – sie tragen aktuell erheblich zu den CO2-Emissionen bei und produzieren jede Menge Müll. Ein Pilotprojekt aus Bonn zeigt, dass viele Op.-Abfälle wiederverwertet werden können.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.