Abstract

Purpose

To compare the diagnostic approach of acute pulmonary embolism (PE) with photon-counting-detector CT (PCD-CT) and energy-integrating-detector CT (EID-CT).

Materials and methods

Two cohorts underwent CT angiographic examinations with EID-CT (Group 1; n = 158) and PCD-CT (Group 2; n = 172), (b) with two options in Group 1, dual energy (Group 1a) or single energy (Group 1b) and a single option in Group 2 (spectral imaging with single source).

Results

In Group 2, all patients benefited from spectral imaging, only accessible to 105 patients (66.5%) in Group 1, with a mean acquisition time significantly shorter (0.9 ± 0.1 s vs 4.0 ± 0 .3 s; p < 0.001) and mean values of CTDIvol and DLP reduced by 46.3% and 47.7%, respectively. Comparing the quality of 70 keV (Group 2) and averaged (Group 1a) images: (a) the mean attenuation within pulmonary arteries did not differ (p = 0.13); (b) the image noise was significantly higher (p < 0.001) in Group 2 with no difference in subjective image noise (p = 0.29); and (c) 89% of examinations were devoid of artifacts in Group 2 vs 28.6% in Group 1a. The percentage of diagnostic examinations was 95.2% (100/105; Group 1a), 100% (53/53; Group 1b), and 95.3% (164/172; Group 2). There were 4.8% (5/105; Group 1a) and 4.7% (8/172; Group 2) of non-diagnostic examinations, mainly due to the suboptimal quality of vascular opacification with the restoration of a diagnostic image quality on low-energy images.

Conclusion

Compared to EID-CT, morphology and perfusion imaging were available in all patients scanned with PCD-CT, with the radiation dose reduced by 48%.

Clinical relevance statement

PCD-CT enables scanning patients with the advantages of both spectral imaging, including high-quality morphologic imaging and lung perfusion for all patients, and fast scanning—a combination that is not simultaneously accessible with EID-CT while reducing the radiation dose by almost 50%.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Remy-Jardin M, Pistolesi M, Goodman LR et al (2007) Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology 245:315–332CrossRefPubMed Remy-Jardin M, Pistolesi M, Goodman LR et al (2007) Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology 245:315–332CrossRefPubMed
2.
Zurück zum Zitat Schoepf UJ, Costello P (2004) CT angiography for diagnosis of pulmonary embolism: state of the art. Radiology 230:329–337CrossRefPubMed Schoepf UJ, Costello P (2004) CT angiography for diagnosis of pulmonary embolism: state of the art. Radiology 230:329–337CrossRefPubMed
3.
Zurück zum Zitat Brunot S, Corneloup O, Latrabe V et al (2005) Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism. Eur Radiol 15:2057–2063CrossRefPubMed Brunot S, Corneloup O, Latrabe V et al (2005) Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism. Eur Radiol 15:2057–2063CrossRefPubMed
4.
Zurück zum Zitat Ghanima W, Nielssen BE, Holmen LO et al (2007) Multidetector computed tomography (MDCT) in the diagnosis of pulmonary embolism: interobserver agreement among radiologists with varied levels of experience. Acta Radiol 48:165–170CrossRefPubMed Ghanima W, Nielssen BE, Holmen LO et al (2007) Multidetector computed tomography (MDCT) in the diagnosis of pulmonary embolism: interobserver agreement among radiologists with varied levels of experience. Acta Radiol 48:165–170CrossRefPubMed
5.
Zurück zum Zitat Le Gal G, Righini M, Parent F et al (2006) Diagnosis and management of subsegmental pulmonary embolism. J Thromb Haemostasis 4:724–731CrossRef Le Gal G, Righini M, Parent F et al (2006) Diagnosis and management of subsegmental pulmonary embolism. J Thromb Haemostasis 4:724–731CrossRef
6.
Zurück zum Zitat Tan S, Hamarati LB, Rajiah PS et al (2022) CTA of acute pulmonary embolism: best practices. Semin Roentgenol 57:313–323CrossRefPubMed Tan S, Hamarati LB, Rajiah PS et al (2022) CTA of acute pulmonary embolism: best practices. Semin Roentgenol 57:313–323CrossRefPubMed
7.
Zurück zum Zitat Delesalle MA, Pontana F, Duhamel A et al (2013) Spectral optimization of chest CT angiography with reduced iodine load; experience in 80 patients evaluated with dual-source, dual-energy CT. Radiology 267:256–266CrossRefPubMed Delesalle MA, Pontana F, Duhamel A et al (2013) Spectral optimization of chest CT angiography with reduced iodine load; experience in 80 patients evaluated with dual-source, dual-energy CT. Radiology 267:256–266CrossRefPubMed
8.
Zurück zum Zitat Yuan R, Shuman WP, Pearls JP et al (2012) Reduced iodine load at CT pulmonary angiography with dual-energy, monochromatic imaging: comparison with standard CT pulmonary angiography—a prospective randomized trial. Radiology 262:290–297CrossRefPubMed Yuan R, Shuman WP, Pearls JP et al (2012) Reduced iodine load at CT pulmonary angiography with dual-energy, monochromatic imaging: comparison with standard CT pulmonary angiography—a prospective randomized trial. Radiology 262:290–297CrossRefPubMed
9.
Zurück zum Zitat Bae K, Jeon KN, Cho SB et al (2018) Improved opacification of a suboptimally enhanced pulmonary artery in chest CT: experience using a dual-layer detector spectral CT. AJR Am J Roentgenol 210:734–741CrossRefPubMed Bae K, Jeon KN, Cho SB et al (2018) Improved opacification of a suboptimally enhanced pulmonary artery in chest CT: experience using a dual-layer detector spectral CT. AJR Am J Roentgenol 210:734–741CrossRefPubMed
10.
Zurück zum Zitat Zhang LJ, Chai X, Wu SY et al (2009) Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits. Eur Radiol 19:2844–2854CrossRefPubMed Zhang LJ, Chai X, Wu SY et al (2009) Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits. Eur Radiol 19:2844–2854CrossRefPubMed
11.
Zurück zum Zitat Krissak R, Henzler T, Reichert M et al (2010) Enhanced visualization of lung vessels for diagnosis of pulmonary embolism using dual energy CT angiography. Invest Radiol 45:341–346CrossRefPubMed Krissak R, Henzler T, Reichert M et al (2010) Enhanced visualization of lung vessels for diagnosis of pulmonary embolism using dual energy CT angiography. Invest Radiol 45:341–346CrossRefPubMed
12.
Zurück zum Zitat Lee CW, Seo JB, Song JW et al (2011) Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography. Eur Radiol 21:54–62CrossRefPubMed Lee CW, Seo JB, Song JW et al (2011) Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography. Eur Radiol 21:54–62CrossRefPubMed
13.
Zurück zum Zitat Apfalter P, Sudarski S, Schneider D et al (2014) Value of monoenergetic low-kV dual-energy CT datasets for improved image quality of CT pulmonary angiography. Eur J Radiol 83:322–328CrossRef Apfalter P, Sudarski S, Schneider D et al (2014) Value of monoenergetic low-kV dual-energy CT datasets for improved image quality of CT pulmonary angiography. Eur J Radiol 83:322–328CrossRef
14.
Zurück zum Zitat Weidman EK, lodowski AJ, Halpenny DF et al (2018) Dual-energy CT angiography for the detection of pulmonary emboli: Incremental benefit of iodine maps. Radiology 289:546–553CrossRefPubMed Weidman EK, lodowski AJ, Halpenny DF et al (2018) Dual-energy CT angiography for the detection of pulmonary emboli: Incremental benefit of iodine maps. Radiology 289:546–553CrossRefPubMed
15.
Zurück zum Zitat Zhang J, Cai J, Liu S, Zhang X (2018) Value of dual-energy lung perfusion imaging using a dual-source CT system for the pulmonary embolism. Open Life Sci 13:107–111CrossRefPubMedPubMedCentral Zhang J, Cai J, Liu S, Zhang X (2018) Value of dual-energy lung perfusion imaging using a dual-source CT system for the pulmonary embolism. Open Life Sci 13:107–111CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Mao X, Wang S, Jiang X et al (2016) Diagnostic value of dual-source computerized tomography combined with perfusion imaging for peripheral pulmonary embolism. Iran J Radiol 13:e29402CrossRefPubMedPubMedCentral Mao X, Wang S, Jiang X et al (2016) Diagnostic value of dual-source computerized tomography combined with perfusion imaging for peripheral pulmonary embolism. Iran J Radiol 13:e29402CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Monti CB, Zanardo M, Cozzi A et al (2021) Dual-energy CT performance in acute pulmonary embolism: a meta-analysis. Eur Radiol 31:6248–6258CrossRefPubMed Monti CB, Zanardo M, Cozzi A et al (2021) Dual-energy CT performance in acute pulmonary embolism: a meta-analysis. Eur Radiol 31:6248–6258CrossRefPubMed
18.
Zurück zum Zitat Abdellatif W, Ebada MA, Alkanj S et al (2021) Diagnostic accuracy of dual-energy CT in detection of acute pulmonary embolism: a systematic review and meta-analysis. Can Assoc Radiol J 72:285–292CrossRefPubMed Abdellatif W, Ebada MA, Alkanj S et al (2021) Diagnostic accuracy of dual-energy CT in detection of acute pulmonary embolism: a systematic review and meta-analysis. Can Assoc Radiol J 72:285–292CrossRefPubMed
19.
Zurück zum Zitat Thieme SF, Becker CR, Hacker M et al (2008) Dual energy CT for the assessment of lung perfusion-correlation to scintigraphy. Eur J Radiol 68:369–374CrossRefPubMed Thieme SF, Becker CR, Hacker M et al (2008) Dual energy CT for the assessment of lung perfusion-correlation to scintigraphy. Eur J Radiol 68:369–374CrossRefPubMed
20.
Zurück zum Zitat Chae EJ, Seo JB, Jang YM et al (2010) Dual-energy CT for assessment of the severity of acute pulmonary embolism: pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio. AJR Am J Roentgenol 194:604–610 Chae EJ, Seo JB, Jang YM et al (2010) Dual-energy CT for assessment of the severity of acute pulmonary embolism: pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio. AJR Am J Roentgenol 194:604–610
21.
Zurück zum Zitat Apfalter P, Bachmann V, Meyer M et al (2012) Prognostic value of perfusion defect volume at dual-energy CTA in patients with pulmonary embolism: correlation with CTA obstruction scores, CT parameters of right ventricular dysfunction and adverse clinical outcome. Eur J Radiol 81:3592–3597CrossRef Apfalter P, Bachmann V, Meyer M et al (2012) Prognostic value of perfusion defect volume at dual-energy CTA in patients with pulmonary embolism: correlation with CTA obstruction scores, CT parameters of right ventricular dysfunction and adverse clinical outcome. Eur J Radiol 81:3592–3597CrossRef
22.
Zurück zum Zitat Meinel F, Graef A, Bamberg F et al (2013) Effectiveness of automated quantification of pulmonary perfused blood volume using dual-energy CTPA for the severity of acute pulmonary embolism. Invest Radiol 48:563–569CrossRefPubMed Meinel F, Graef A, Bamberg F et al (2013) Effectiveness of automated quantification of pulmonary perfused blood volume using dual-energy CTPA for the severity of acute pulmonary embolism. Invest Radiol 48:563–569CrossRefPubMed
23.
Zurück zum Zitat Yalynska T, Polacin M, Frauenfelder T, Martini K (2022) Impact of photon-counting detector CT derived virtual monoenergetic images in the diagnosis of pulmonary embolism. Diagnostics 12:2715CrossRefPubMedPubMedCentral Yalynska T, Polacin M, Frauenfelder T, Martini K (2022) Impact of photon-counting detector CT derived virtual monoenergetic images in the diagnosis of pulmonary embolism. Diagnostics 12:2715CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Pannenbecker P, Huflage H, Grunz JP et al (2023) Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction. Eur Radiol 33:7830–7839CrossRefPubMedPubMedCentral Pannenbecker P, Huflage H, Grunz JP et al (2023) Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction. Eur Radiol 33:7830–7839CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Pinilo J, Hutt A, Labreuche J et al (2022) Evaluation of a new reconstruction technique for dual-energy (DECT) lung perfusion: preliminary experience in 58 patients Acad Radiol 29(Suppl 2):S202–S214CrossRefPubMed Pinilo J, Hutt A, Labreuche J et al (2022) Evaluation of a new reconstruction technique for dual-energy (DECT) lung perfusion: preliminary experience in 58 patients Acad Radiol 29(Suppl 2):S202–S214CrossRefPubMed
26.
Zurück zum Zitat Niemann T, Henry S, Faivre JB et al (2013) Clinical evaluation of automatic tube voltage selection in chest CT angiography. Eur Radiol 23:2643–2651CrossRefPubMed Niemann T, Henry S, Faivre JB et al (2013) Clinical evaluation of automatic tube voltage selection in chest CT angiography. Eur Radiol 23:2643–2651CrossRefPubMed
27.
Zurück zum Zitat Hagen F, Walder L, Fritz J et al (2022) Image quality and radiation dose of contrast-enhanced chest-CT acquired on a clinical photon-counting detector CT vs second-generation dual-source CT in an oncologic cohort: preliminary results. Tomography 8:1466–1476CrossRefPubMedPubMedCentral Hagen F, Walder L, Fritz J et al (2022) Image quality and radiation dose of contrast-enhanced chest-CT acquired on a clinical photon-counting detector CT vs second-generation dual-source CT in an oncologic cohort: preliminary results. Tomography 8:1466–1476CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Thakur R, Singhal M, Aggrawal AN et al (2022) Comparison of high-pitch prospective electrocardiogram-gated pulmonary CT angiography with standard CT pulmonary angiography on dual-source CT for detection of subsegmental pulmonary embolism in patients suspected of acute pulmonary embolism. Pol J Radiol 87:e296–e303CrossRefPubMedPubMedCentral Thakur R, Singhal M, Aggrawal AN et al (2022) Comparison of high-pitch prospective electrocardiogram-gated pulmonary CT angiography with standard CT pulmonary angiography on dual-source CT for detection of subsegmental pulmonary embolism in patients suspected of acute pulmonary embolism. Pol J Radiol 87:e296–e303CrossRefPubMedPubMedCentral
29.
Zurück zum Zitat Pannenbecker P, Heidenreich JF, Grunz JP et al (2024) Image quality and radiation dose of CTPA with iodine maps: a prospective randomized study of high-pitch mode photon-counting detector ct versus energy-integrating detector CT. AJR Am J Roentgenol 222:e2330154CrossRefPubMed Pannenbecker P, Heidenreich JF, Grunz JP et al (2024) Image quality and radiation dose of CTPA with iodine maps: a prospective randomized study of high-pitch mode photon-counting detector ct versus energy-integrating detector CT. AJR Am J Roentgenol 222:e2330154CrossRefPubMed
30.
Zurück zum Zitat Leitner D, Wichmann JL, Vogl TJ et al (2017) Virtual monoenergetic imaging and iodine perfusion maps improve diagnostic accuracy of dual-energy computed tomography pulmonary angiography with suboptimal contrast attenuation. Invest Radiol 52:659–665CrossRef Leitner D, Wichmann JL, Vogl TJ et al (2017) Virtual monoenergetic imaging and iodine perfusion maps improve diagnostic accuracy of dual-energy computed tomography pulmonary angiography with suboptimal contrast attenuation. Invest Radiol 52:659–665CrossRef
31.
Zurück zum Zitat Wannasopha Y, Leesmidt K, Srisuwan T et al (2022) Value of low-keV virtual monoenergetic plus dual-energy computed tomographic imaging for detection of acute pulmonary embolism. PLoS One 14:e0277060CrossRef Wannasopha Y, Leesmidt K, Srisuwan T et al (2022) Value of low-keV virtual monoenergetic plus dual-energy computed tomographic imaging for detection of acute pulmonary embolism. PLoS One 14:e0277060CrossRef
32.
Zurück zum Zitat Bach AG, Meyer HJ, Taute BM, Surov A (2016) The frequency of incidental pulmonary embolism in different CT examinations. Br J Radiol 89:20150737CrossRefPubMed Bach AG, Meyer HJ, Taute BM, Surov A (2016) The frequency of incidental pulmonary embolism in different CT examinations. Br J Radiol 89:20150737CrossRefPubMed
33.
Zurück zum Zitat Weiss J, Notohamiprodjo M et al (2017) Effect of noise-optimized monoenergetic postprocessing on diagnostic accuracy for detecting incidental pulmonary embolism in portal-venous phase dual-energy computed tomography. Invest Radiol 52:142–147CrossRefPubMed Weiss J, Notohamiprodjo M et al (2017) Effect of noise-optimized monoenergetic postprocessing on diagnostic accuracy for detecting incidental pulmonary embolism in portal-venous phase dual-energy computed tomography. Invest Radiol 52:142–147CrossRefPubMed
34.
Zurück zum Zitat Yoo HHB, Marin FL (2020) Isolated subsegmental pulmonary embolism: current therapeutic challenges. Pol Arch Intern Med 130:986–991PubMed Yoo HHB, Marin FL (2020) Isolated subsegmental pulmonary embolism: current therapeutic challenges. Pol Arch Intern Med 130:986–991PubMed
35.
Zurück zum Zitat Zeng Y, Geng D, Zhang J (2021) Noise-optimized virtual monoenergetic imaging technology of the third-generation dual-source computed tomography and its clinical applications. Quant Imaging Med Surg 11:4627–4643CrossRefPubMedPubMedCentral Zeng Y, Geng D, Zhang J (2021) Noise-optimized virtual monoenergetic imaging technology of the third-generation dual-source computed tomography and its clinical applications. Quant Imaging Med Surg 11:4627–4643CrossRefPubMedPubMedCentral
Metadaten
Titel
Diagnosis of acute pulmonary embolism: when photon-counting-detector CT replaces energy-integrating-detector CT in daily routine
verfasst von
Martine Remy-Jardin
Idir Oufriche
Lucas Guiffault
Alain Duhamel
Thomas Flohr
Bernhard Schmidt
Jacques Remy
Publikationsdatum
18.04.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-024-10724-5

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.