Skip to main content
Erschienen in: Pediatric Radiology 7/2023

18.10.2022 | Improving Protocols

State-of-the-art magnetic resonance imaging sequences for pediatric body imaging

verfasst von: Mareen Sarah Kraus, Ailish C. Coblentz, Vibhas S. Deshpande, Johannes M. Peeters, Pedro M. Itriago-Leon, Govind B. Chavhan

Erschienen in: Pediatric Radiology | Ausgabe 7/2023

Einloggen, um Zugang zu erhalten

Abstract

Longer examination time, need for anesthesia in smaller children and the inability of most children to hold their breath are major limitations of MRI in pediatric body imaging. Fortunately, with technical advances, many new and upcoming MRI sequences are overcoming these limitations. Advances in data acquisition and k-space sampling methods have enabled sequences with improved temporal and spatial resolution, and minimal artifacts. Sequences to minimize movement artifacts mainly utilize radial k-space filling, and examples include the stack-of-stars method for T1-weighted imaging and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)/BLADE method for T2-weighted imaging. Similarly, the sequences with improved temporal resolution and the ability to obtain multiple phases in a single breath-hold in dynamic imaging mainly use some form of partial k-space filling method. New sequences use a variable combination of data sampling methods like compressed sensing, golden-angle radial k-space filling, parallel imaging and partial k-space filling to achieve free-breathing, faster sequences that could be useful for pediatric abdominal and thoracic imaging. Simultaneous multi-slice method has improved diffusion-weighted imaging (DWI) with reduction in scan time and artifacts. In this review, we provide an overview of data sampling methods like parallel imaging, compressed sensing, radial k-space sampling, partial k-space sampling and simultaneous multi-slice. This is followed by newer available and upcoming sequences for T1-, T2- and DWI based on these other advances. We also discuss the Dixon method and newer approaches to reducing metal artifacts.
Literatur
1.
Zurück zum Zitat Smith-Bindman R, Kwan ML, Marlow EC et al (2019) Trends in use of medical imaging in U.S. health care systems and in Ontario, Canada, 2000–2016. JAMA 322:843–856PubMedPubMedCentralCrossRef Smith-Bindman R, Kwan ML, Marlow EC et al (2019) Trends in use of medical imaging in U.S. health care systems and in Ontario, Canada, 2000–2016. JAMA 322:843–856PubMedPubMedCentralCrossRef
2.
Zurück zum Zitat Yoon JH, Nickel MD, Peeters JM, Lee JM (2019) Rapid imaging: recent advances in abdominal MRI for reducing acquisition time and its clinical applications. Korean J Radiol 20:1597–1615PubMedPubMedCentralCrossRef Yoon JH, Nickel MD, Peeters JM, Lee JM (2019) Rapid imaging: recent advances in abdominal MRI for reducing acquisition time and its clinical applications. Korean J Radiol 20:1597–1615PubMedPubMedCentralCrossRef
3.
Zurück zum Zitat Bardo DME, Rubert N (2022) Radial sequences and compressed sensing in pediatric body magnetic resonance imaging. Pediatr Radiol 52:382–390PubMedCrossRef Bardo DME, Rubert N (2022) Radial sequences and compressed sensing in pediatric body magnetic resonance imaging. Pediatr Radiol 52:382–390PubMedCrossRef
4.
6.
Zurück zum Zitat Kozak BM, Jaimes C, Kirsch J, Gee MS (2020) MRI techniques to decrease imaging times in children. Radiographics 40:485–502PubMedCrossRef Kozak BM, Jaimes C, Kirsch J, Gee MS (2020) MRI techniques to decrease imaging times in children. Radiographics 40:485–502PubMedCrossRef
7.
Zurück zum Zitat Peeters JM, Fuderer M (2013) SENSE with improved tolerance to inaccuracies in coil sensitivity maps. Magn Reson Med 69:1665–1669PubMedCrossRef Peeters JM, Fuderer M (2013) SENSE with improved tolerance to inaccuracies in coil sensitivity maps. Magn Reson Med 69:1665–1669PubMedCrossRef
8.
Zurück zum Zitat Griswold MA, Jakob PM, Heidemann RM et al (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202–1210PubMedCrossRef Griswold MA, Jakob PM, Heidemann RM et al (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202–1210PubMedCrossRef
9.
Zurück zum Zitat Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962PubMedCrossRef Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962PubMedCrossRef
10.
Zurück zum Zitat Chavhan GB, Babyn PS, Singh M et al (2009) MR imaging at 3.0 T in children: technical differences, safety issues, and initial experience. Radiographics 29:1451–1466PubMedCrossRef Chavhan GB, Babyn PS, Singh M et al (2009) MR imaging at 3.0 T in children: technical differences, safety issues, and initial experience. Radiographics 29:1451–1466PubMedCrossRef
11.
Zurück zum Zitat Jornada Tda S, Murata CH, Medeiros RB (2016) Influence of partial k-space filling on the quality of magnetic resonance images. Radiol Bras 49:158–164PubMedCrossRef Jornada Tda S, Murata CH, Medeiros RB (2016) Influence of partial k-space filling on the quality of magnetic resonance images. Radiol Bras 49:158–164PubMedCrossRef
12.
Zurück zum Zitat Barth M, Breuer F, Koopmans PJ et al (2016) Simultaneous multislice (SMS) imaging techniques. Magn Reson Med 75:63–81PubMedCrossRef Barth M, Breuer F, Koopmans PJ et al (2016) Simultaneous multislice (SMS) imaging techniques. Magn Reson Med 75:63–81PubMedCrossRef
13.
Zurück zum Zitat Wang D, Kollasch P, Li X et al (2014) Multiband slice accelerated TSE: clinical applications in brain imaging. Proc Int Soc Mag Reson Med 22:4317 Wang D, Kollasch P, Li X et al (2014) Multiband slice accelerated TSE: clinical applications in brain imaging. Proc Int Soc Mag Reson Med 22:4317
14.
Zurück zum Zitat Runge VM, Richter JK, Heverhagen JT (2017) Speed in clinical magnetic resonance. Investig Radiol 52:1–17CrossRef Runge VM, Richter JK, Heverhagen JT (2017) Speed in clinical magnetic resonance. Investig Radiol 52:1–17CrossRef
15.
Zurück zum Zitat Taron J, Martirosian P, Kuestner T et al (2018) Scan time reduction in diffusion-weighted imaging of the pancreas using a simultaneous multislice technique with different acceleration factors: how fast can we go? Eur Radiol 28:1504–1511PubMedCrossRef Taron J, Martirosian P, Kuestner T et al (2018) Scan time reduction in diffusion-weighted imaging of the pancreas using a simultaneous multislice technique with different acceleration factors: how fast can we go? Eur Radiol 28:1504–1511PubMedCrossRef
16.
Zurück zum Zitat Benali S, Johnston PR, Gholipour A et al (2018) Simultaneous multi-slice accelerated turbo spin echo of the knee in pediatric patients. Skelet Radiol 47:821–831CrossRef Benali S, Johnston PR, Gholipour A et al (2018) Simultaneous multi-slice accelerated turbo spin echo of the knee in pediatric patients. Skelet Radiol 47:821–831CrossRef
17.
Zurück zum Zitat Ji Y, Hoge WS, Gagoski B et al (2022) Accelerating joint relaxation-diffusion MRI by integrating time division multiplexing and simultaneous multi-slice (TDM-SMS) strategies. Magn Reson Med 87:2697–2709PubMedPubMedCentralCrossRef Ji Y, Hoge WS, Gagoski B et al (2022) Accelerating joint relaxation-diffusion MRI by integrating time division multiplexing and simultaneous multi-slice (TDM-SMS) strategies. Magn Reson Med 87:2697–2709PubMedPubMedCentralCrossRef
18.
Zurück zum Zitat Tabari A, Machado-Rivas F, Kirsch JE et al (2021) Performance of simultaneous multi-slice accelerated diffusion-weighted imaging for assessing focal renal lesions in pediatric patients with tuberous sclerosis complex. Pediatr Radiol 51:77–85PubMedCrossRef Tabari A, Machado-Rivas F, Kirsch JE et al (2021) Performance of simultaneous multi-slice accelerated diffusion-weighted imaging for assessing focal renal lesions in pediatric patients with tuberous sclerosis complex. Pediatr Radiol 51:77–85PubMedCrossRef
19.
Zurück zum Zitat Hirokawa Y, Isoda H, Maetani YS et al (2008) MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique. AJR Am J Roentgenol 191:1154–1158PubMedCrossRef Hirokawa Y, Isoda H, Maetani YS et al (2008) MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique. AJR Am J Roentgenol 191:1154–1158PubMedCrossRef
20.
Zurück zum Zitat Kim YC (2019) Advanced methods in dynamic contrast enhanced arterial phase imaging of the liver. Investig Magn Reson Imaging 23:1–16CrossRef Kim YC (2019) Advanced methods in dynamic contrast enhanced arterial phase imaging of the liver. Investig Magn Reson Imaging 23:1–16CrossRef
21.
Zurück zum Zitat Nam JG, Lee JM, Lee SM et al (2019) High acceleration three-dimensional T1-weighted dual echo Dixon hepatobiliary phase imaging using compressed sensing-sensitivity encoding: comparison of image quality and solid lesion detectability with the standard T1-weighted sequence. Korean J Radiol 20:438–448PubMedPubMedCentralCrossRef Nam JG, Lee JM, Lee SM et al (2019) High acceleration three-dimensional T1-weighted dual echo Dixon hepatobiliary phase imaging using compressed sensing-sensitivity encoding: comparison of image quality and solid lesion detectability with the standard T1-weighted sequence. Korean J Radiol 20:438–448PubMedPubMedCentralCrossRef
22.
Zurück zum Zitat Feng L, Benkert T, Block KT et al (2017) Compressed sensing for body MRI. J Magn Reson Imaging 45:966–987PubMedCrossRef Feng L, Benkert T, Block KT et al (2017) Compressed sensing for body MRI. J Magn Reson Imaging 45:966–987PubMedCrossRef
23.
Zurück zum Zitat Chandarana H, Feng L, Ream J et al (2015) Respiratory motion-resolved compressed sensing reconstruction of free-breathing radial acquisition for dynamic liver magnetic resonance imaging. Investig Radiol 50:749–756CrossRef Chandarana H, Feng L, Ream J et al (2015) Respiratory motion-resolved compressed sensing reconstruction of free-breathing radial acquisition for dynamic liver magnetic resonance imaging. Investig Radiol 50:749–756CrossRef
24.
Zurück zum Zitat Zhang T, Yousaf U, Hsiao A et al (2015) Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography. Pediatr Radiol 45:1635–1643PubMedPubMedCentralCrossRef Zhang T, Yousaf U, Hsiao A et al (2015) Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography. Pediatr Radiol 45:1635–1643PubMedPubMedCentralCrossRef
25.
Zurück zum Zitat Robertson RL, Silk S, Ecklund K et al (2018) Imaging optimization in children. J Am Coll Radiol 15:440–443PubMedCrossRef Robertson RL, Silk S, Ecklund K et al (2018) Imaging optimization in children. J Am Coll Radiol 15:440–443PubMedCrossRef
26.
Zurück zum Zitat Chandarana H, Block KT, Winfeld MJ et al (2014) Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI. Eur Radiol 24:320–326PubMedCrossRef Chandarana H, Block KT, Winfeld MJ et al (2014) Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI. Eur Radiol 24:320–326PubMedCrossRef
27.
Zurück zum Zitat Coll-Font J, Afacan O, Chow JS et al (2020) Bulk motion-compensated DCE-MRI for functional imaging of kidneys in newborns. J Magn Reson Imaging 52:207–216PubMedCrossRef Coll-Font J, Afacan O, Chow JS et al (2020) Bulk motion-compensated DCE-MRI for functional imaging of kidneys in newborns. J Magn Reson Imaging 52:207–216PubMedCrossRef
28.
Zurück zum Zitat Duffy PB, Stemmer A, Callahan MJ et al (2021) Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients. Pediatr Radiol 51:1645–1653PubMedCrossRef Duffy PB, Stemmer A, Callahan MJ et al (2021) Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients. Pediatr Radiol 51:1645–1653PubMedCrossRef
29.
Zurück zum Zitat Browne LP, Malone LJ, Englund EK et al (2022) Free-breathing magnetic resonance imaging with radial k-space sampling for neonates and infants to reduce anesthesia. Pediatr Radiol 52:1326–1337PubMedCrossRef Browne LP, Malone LJ, Englund EK et al (2022) Free-breathing magnetic resonance imaging with radial k-space sampling for neonates and infants to reduce anesthesia. Pediatr Radiol 52:1326–1337PubMedCrossRef
30.
Zurück zum Zitat Balza R, Jaimes C, Risacher S et al (2019) Impact of a fast free-breathing 3-T abdominal MRI protocol on improving scan time and image quality for pediatric patients with tuberous sclerosis complex. Pediatr Radiol 49:1788–1797PubMedCrossRef Balza R, Jaimes C, Risacher S et al (2019) Impact of a fast free-breathing 3-T abdominal MRI protocol on improving scan time and image quality for pediatric patients with tuberous sclerosis complex. Pediatr Radiol 49:1788–1797PubMedCrossRef
31.
Zurück zum Zitat Gruber L, Rainer V, Plaikner M et al (2018) CAIPIRINHA-Dixon-TWIST (CDT)-VIBE MR imaging of the liver at 3.0 T with gadoxetate disodium: a solution for transient arterial-phase respiratory motion-related artifacts? Eur Radiol 28:2013–2021PubMedCrossRef Gruber L, Rainer V, Plaikner M et al (2018) CAIPIRINHA-Dixon-TWIST (CDT)-VIBE MR imaging of the liver at 3.0 T with gadoxetate disodium: a solution for transient arterial-phase respiratory motion-related artifacts? Eur Radiol 28:2013–2021PubMedCrossRef
32.
Zurück zum Zitat Saranathan M, Rettmann DW, Hargreaves BA et al (2012) Differential subsampling with Cartesian ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging. J Magn Reson Imaging 35:1484–1492PubMedPubMedCentralCrossRef Saranathan M, Rettmann DW, Hargreaves BA et al (2012) Differential subsampling with Cartesian ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging. J Magn Reson Imaging 35:1484–1492PubMedPubMedCentralCrossRef
33.
Zurück zum Zitat Yoon JH, Lee JM, Yu MH et al (2022) Simultaneous evaluation of perfusion and morphology using GRASP MRI in hepatic fibrosis. Eur Radiol 32:34–45PubMedCrossRef Yoon JH, Lee JM, Yu MH et al (2022) Simultaneous evaluation of perfusion and morphology using GRASP MRI in hepatic fibrosis. Eur Radiol 32:34–45PubMedCrossRef
34.
Zurück zum Zitat Choi KS, Choi YH, Cheon JE et al (2020) Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence. Acta Radiol 61:1406–1413PubMedCrossRef Choi KS, Choi YH, Cheon JE et al (2020) Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence. Acta Radiol 61:1406–1413PubMedCrossRef
35.
Zurück zum Zitat Busse RF, Brau AC, Vu A et al (2008) Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magn Reson Med 60:640–649PubMedPubMedCentralCrossRef Busse RF, Brau AC, Vu A et al (2008) Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magn Reson Med 60:640–649PubMedPubMedCentralCrossRef
36.
Zurück zum Zitat Mugler JP 3rd (2014) Optimized three-dimensional fast-spin-echo MRI. J Magn Reson Imaging 39:745–767PubMedCrossRef Mugler JP 3rd (2014) Optimized three-dimensional fast-spin-echo MRI. J Magn Reson Imaging 39:745–767PubMedCrossRef
37.
Zurück zum Zitat Park HJ, Lee SY, Kang KA et al (2018) Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist. Br J Radiol 91:20170604PubMedPubMedCentralCrossRef Park HJ, Lee SY, Kang KA et al (2018) Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist. Br J Radiol 91:20170604PubMedPubMedCentralCrossRef
38.
Zurück zum Zitat Bao S, Tamir JI, Young JL et al (2017) Fast comprehensive single-sequence four-dimensional pediatric knee MRI with T2 shuffling. J Magn Reson Imaging 45:1700–1711PubMedCrossRef Bao S, Tamir JI, Young JL et al (2017) Fast comprehensive single-sequence four-dimensional pediatric knee MRI with T2 shuffling. J Magn Reson Imaging 45:1700–1711PubMedCrossRef
39.
Zurück zum Zitat Serai SD, Hu HH, Ahmad R et al (2020) Newly developed methods for reducing motion artifacts in pediatric abdominal MRI: tips and pearls. AJR Am J Roentgenol 214:1042–1053PubMedCrossRef Serai SD, Hu HH, Ahmad R et al (2020) Newly developed methods for reducing motion artifacts in pediatric abdominal MRI: tips and pearls. AJR Am J Roentgenol 214:1042–1053PubMedCrossRef
40.
Zurück zum Zitat Lee JH, Choi YH, Cheon JE et al (2015) Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique. Pediatr Radiol 45:840–846PubMedCrossRef Lee JH, Choi YH, Cheon JE et al (2015) Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique. Pediatr Radiol 45:840–846PubMedCrossRef
41.
Zurück zum Zitat Haneder S, Dinter D, Gutfleisch A et al (2011) Image quality of T2W-TSE of the abdomen and pelvis with Cartesian or BLADE-type k-space sampling: a retrospective interindividual comparison study. Eur J Radiol 79:177–182PubMedCrossRef Haneder S, Dinter D, Gutfleisch A et al (2011) Image quality of T2W-TSE of the abdomen and pelvis with Cartesian or BLADE-type k-space sampling: a retrospective interindividual comparison study. Eur J Radiol 79:177–182PubMedCrossRef
42.
Zurück zum Zitat Zaccagnino E, Devincent C, Leelakanok N et al (2019) Assessment of quiet T2 weighted PROPELLER sequence in pediatric abdominal imaging. Clin Imaging 53:12–16PubMedCrossRef Zaccagnino E, Devincent C, Leelakanok N et al (2019) Assessment of quiet T2 weighted PROPELLER sequence in pediatric abdominal imaging. Clin Imaging 53:12–16PubMedCrossRef
43.
Zurück zum Zitat Chavhan GB, Babyn PS, Manson D, Vidarsson L (2008) Pediatric MR cholangiopancreatography: principles, technique, and clinical applications. Radiographics 28:1951–1962PubMedCrossRef Chavhan GB, Babyn PS, Manson D, Vidarsson L (2008) Pediatric MR cholangiopancreatography: principles, technique, and clinical applications. Radiographics 28:1951–1962PubMedCrossRef
44.
Zurück zum Zitat Yoon JH, Lee SM, Kang HJ et al (2017) Clinical feasibility of 3-dimensional magnetic resonance cholangiopancreatography using compressed sensing: comparison of image quality and diagnostic performance. Investig Radiol 52:612–619CrossRef Yoon JH, Lee SM, Kang HJ et al (2017) Clinical feasibility of 3-dimensional magnetic resonance cholangiopancreatography using compressed sensing: comparison of image quality and diagnostic performance. Investig Radiol 52:612–619CrossRef
45.
Zurück zum Zitat Mannes I, Dallongeville A, Badat N et al (2020) Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders. Abdom Radiol 45:1082–1091CrossRef Mannes I, Dallongeville A, Badat N et al (2020) Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders. Abdom Radiol 45:1082–1091CrossRef
46.
Zurück zum Zitat Blaise H, Remen T, Ambarki K et al (2021) Comparison of respiratory-triggered 3D MR cholangiopancreatography and breath-hold compressed-sensing 3D MR cholangiopancreatography at 1.5 T and 3 T and impact of individual factors on image quality. Eur J Radiol 142(109873) Blaise H, Remen T, Ambarki K et al (2021) Comparison of respiratory-triggered 3D MR cholangiopancreatography and breath-hold compressed-sensing 3D MR cholangiopancreatography at 1.5 T and 3 T and impact of individual factors on image quality. Eur J Radiol 142(109873)
47.
Zurück zum Zitat Nam JG, Lee JM, Kang HJ et al (2018) GRASE revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a gradient and spin echo (GRASE) technique at 3T. Eur Radiol 28:3721–3728PubMedCrossRef Nam JG, Lee JM, Kang HJ et al (2018) GRASE revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a gradient and spin echo (GRASE) technique at 3T. Eur Radiol 28:3721–3728PubMedCrossRef
48.
Zurück zum Zitat Yoshida M, Nakaura T, Inoue T et al (2018) Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0 T: does it improve image quality and acquisition time as compared with 3D TSE? Eur Radiol 28:2436–2443PubMedCrossRef Yoshida M, Nakaura T, Inoue T et al (2018) Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0 T: does it improve image quality and acquisition time as compared with 3D TSE? Eur Radiol 28:2436–2443PubMedCrossRef
49.
Zurück zum Zitat Szklaruk J, Son JB, Wei W et al (2019) Comparison of free breathing and respiratory triggered diffusion-weighted imaging sequences for liver imaging. World J Radiol 11:134–143PubMedPubMedCentralCrossRef Szklaruk J, Son JB, Wei W et al (2019) Comparison of free breathing and respiratory triggered diffusion-weighted imaging sequences for liver imaging. World J Radiol 11:134–143PubMedPubMedCentralCrossRef
50.
Zurück zum Zitat Kaga T, Noda Y, Mori T et al (2021) Diffusion-weighted imaging of the abdomen using echo planar imaging with compressed SENSE: feasibility, image quality, and ADC value evaluation. Eur J Radiol 142:109889PubMedCrossRef Kaga T, Noda Y, Mori T et al (2021) Diffusion-weighted imaging of the abdomen using echo planar imaging with compressed SENSE: feasibility, image quality, and ADC value evaluation. Eur J Radiol 142:109889PubMedCrossRef
51.
Zurück zum Zitat Kamal O, McTavish S, Harder FN et al (2022) Noise reduction in diffusion weighted MRI of the pancreas using an L1-regularized iterative SENSE reconstruction. Magn Reson Imaging 87:1–6PubMedCrossRef Kamal O, McTavish S, Harder FN et al (2022) Noise reduction in diffusion weighted MRI of the pancreas using an L1-regularized iterative SENSE reconstruction. Magn Reson Imaging 87:1–6PubMedCrossRef
53.
54.
Zurück zum Zitat Pokorney AL, Chia JM, Pfeifer CM et al (2017) Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T. Acta Radiol 58:1386–1394PubMedCrossRef Pokorney AL, Chia JM, Pfeifer CM et al (2017) Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T. Acta Radiol 58:1386–1394PubMedCrossRef
55.
Zurück zum Zitat Kammen BF, Padua EM, Karakas SP et al (2019) Clinical experience with two-point mDixon turbo spin echo as an alternative to conventional turbo spin echo for magnetic resonance imaging of the pediatric knee. Pediatr Radiol 49:791–800PubMedCrossRef Kammen BF, Padua EM, Karakas SP et al (2019) Clinical experience with two-point mDixon turbo spin echo as an alternative to conventional turbo spin echo for magnetic resonance imaging of the pediatric knee. Pediatr Radiol 49:791–800PubMedCrossRef
56.
Zurück zum Zitat Ma J, Singh SK, Kumar AJ et al (2004) T2-weighted spine imaging with a fast three-point Dixon technique: comparison with chemical shift selective fat suppression. J Magn Reson Imaging 20:1025–1029PubMedCrossRef Ma J, Singh SK, Kumar AJ et al (2004) T2-weighted spine imaging with a fast three-point Dixon technique: comparison with chemical shift selective fat suppression. J Magn Reson Imaging 20:1025–1029PubMedCrossRef
57.
Zurück zum Zitat Ma J (2004) Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm. Magn Reson Med 52:415–419PubMedCrossRef Ma J (2004) Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm. Magn Reson Med 52:415–419PubMedCrossRef
58.
Zurück zum Zitat Xiang QS (2006) Two-point water-fat imaging with partially-opposed-phase (POP) acquisition: an asymmetric Dixon method. Magn Reson Med 56:572–584PubMedCrossRef Xiang QS (2006) Two-point water-fat imaging with partially-opposed-phase (POP) acquisition: an asymmetric Dixon method. Magn Reson Med 56:572–584PubMedCrossRef
59.
Zurück zum Zitat Eggers H, Brendel B, Duijndam A, Herigault G (2011) Dual-echo Dixon imaging with flexible choice of echo times. Magn Reson Med 65:96–107PubMedCrossRef Eggers H, Brendel B, Duijndam A, Herigault G (2011) Dual-echo Dixon imaging with flexible choice of echo times. Magn Reson Med 65:96–107PubMedCrossRef
60.
Zurück zum Zitat Jungmann PM, Agten CA, Pfirrmann CW, Sutter R (2017) Advances in MRI around metal. J Magn Reson Imaging 46:972–991PubMedCrossRef Jungmann PM, Agten CA, Pfirrmann CW, Sutter R (2017) Advances in MRI around metal. J Magn Reson Imaging 46:972–991PubMedCrossRef
61.
Zurück zum Zitat Carl M, Koch K, Du J (2013) MR imaging near metal with undersampled 3D radial UTE-MAVRIC sequences. Magn Reson Med 69:27–36PubMedCrossRef Carl M, Koch K, Du J (2013) MR imaging near metal with undersampled 3D radial UTE-MAVRIC sequences. Magn Reson Med 69:27–36PubMedCrossRef
Metadaten
Titel
State-of-the-art magnetic resonance imaging sequences for pediatric body imaging
verfasst von
Mareen Sarah Kraus
Ailish C. Coblentz
Vibhas S. Deshpande
Johannes M. Peeters
Pedro M. Itriago-Leon
Govind B. Chavhan
Publikationsdatum
18.10.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 7/2023
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-022-05528-y

Weitere Artikel der Ausgabe 7/2023

Pediatric Radiology 7/2023 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.