Skip to main content
Erschienen in: Abdominal Radiology 4/2020

09.10.2019 | Pancreas

Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders

verfasst von: Inès Mannes, Axel Dallongeville, Neesmah Badat, Hélène Beaussier, Gilles Chatellier, Marc Zins

Erschienen in: Abdominal Radiology | Ausgabe 4/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To compare image quality and diagnostic performance of three magnetic resonance cholangiopancreatography (MRCP) protocols in patients with suspected pancreatic abnormalities: free-breathing standard 3D-MRCP (STD), free-breathing compressed sensing 3D-MRCP (CS), and CS 3D-MRCP with acquisition during a single breath-hold > 20 s (BH-CS).

Methods

Informed consent was obtained. We performed 57 MRCPs in 56 prospectively included patients (29 men, median age 59 years). The three protocols were performed in random order. Acquisition time was recorded. Two radiologists blinded to the protocols used 5-point scales to assess image quality parameters (overall image quality, amount of artifacts, background suppression, bile and pancreatic duct visualization) and diagnostic performance (anatomical variants, duct abnormalities, cystic lesions).

Results

Acquisition time was 279 s with STD, 176 s with CS (-37%), and 22 s with BH-CS (-93%). STD and BH-CS were not significantly different for overall image quality, artifacts, or background suppression. The BH-CS group had fewer non-diagnostic scans (3% vs. 19% with STD and 21% with CS, p < 0.05), higher-quality scans (78% vs. 66% with STD and 58% with CS, p < 0.05), and milder artifacts (2% vs. 18% with STD and 16% with CS, p < 0.05). The main pancreatic duct was better visualized with BH-CS compared to STD (p = 0.015) and CS (p < 0.001). Diagnostic performance did not differ across the three protocols. There were fewer indeterminate scans in the BH-CS group.

Conclusion

3T BH-CS is reliable, saves time, and is not associated with decreases in image quality or diagnostic performance compared to STD and CS.
Literatur
1.
Zurück zum Zitat Barish MA, Yucel EK, Ferrucci JT (1999) Magnetic resonance cholangiopancreatography. N Engl J Med 341:258–264.CrossRef Barish MA, Yucel EK, Ferrucci JT (1999) Magnetic resonance cholangiopancreatography. N Engl J Med 341:258–264.CrossRef
2.
Zurück zum Zitat Nandalur KR, Hussain HK, Weadock WJ, et al (2008) Possible Biliary Disease: Diagnostic Performance of High-Spatial-Resolution Isotropic 3D T2-weighted MRCP. Radiology 249:883–890.CrossRef Nandalur KR, Hussain HK, Weadock WJ, et al (2008) Possible Biliary Disease: Diagnostic Performance of High-Spatial-Resolution Isotropic 3D T2-weighted MRCP. Radiology 249:883–890.CrossRef
3.
Zurück zum Zitat Irie H, Honda H, Tajima T, et al (1998) Optimal MR cholangiopancreatographic sequence and its clinical application. Radiology 206:379–387.CrossRef Irie H, Honda H, Tajima T, et al (1998) Optimal MR cholangiopancreatographic sequence and its clinical application. Radiology 206:379–387.CrossRef
4.
Zurück zum Zitat Wallner BK, Schumacher KA, Weidenmaier W, Friedrich JM (1991) Dilated biliary tract: evaluation with MR cholangiography with a T2-weighted contrast-enhanced fast sequence. Radiology 181:805–808.CrossRef Wallner BK, Schumacher KA, Weidenmaier W, Friedrich JM (1991) Dilated biliary tract: evaluation with MR cholangiography with a T2-weighted contrast-enhanced fast sequence. Radiology 181:805–808.CrossRef
5.
Zurück zum Zitat Asbach P, Dewey M, Klessen C, et al (2006) Respiratory-triggered MRCP applying parallel acquisition techniques. J Magn Reson Imaging 24:1095–1100.CrossRef Asbach P, Dewey M, Klessen C, et al (2006) Respiratory-triggered MRCP applying parallel acquisition techniques. J Magn Reson Imaging 24:1095–1100.CrossRef
6.
Zurück zum Zitat Zhang J, Israel GM, Hecht EM, Krinsky GA, Babb JS, Lee VS (2006) Isotropic 3D T2-Weighted MR Cholangiopancreatography with Parallel Imaging: Feasibility Study. Am J Roentgenol 187:1564–1570.CrossRef Zhang J, Israel GM, Hecht EM, Krinsky GA, Babb JS, Lee VS (2006) Isotropic 3D T2-Weighted MR Cholangiopancreatography with Parallel Imaging: Feasibility Study. Am J Roentgenol 187:1564–1570.CrossRef
7.
Zurück zum Zitat Yoshida M, Nakaura T, Inoue T, et al (2018) Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE? Eur Radiol 28:2436–2443.CrossRef Yoshida M, Nakaura T, Inoue T, et al (2018) Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE? Eur Radiol 28:2436–2443.CrossRef
8.
Zurück zum Zitat Nam JG, Lee JM, Kang H-J, et al (2018) GRASE Revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a Gradient and Spin Echo (GRASE) technique at 3T. Eur Radiol 28:3721–3728CrossRef Nam JG, Lee JM, Kang H-J, et al (2018) GRASE Revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a Gradient and Spin Echo (GRASE) technique at 3T. Eur Radiol 28:3721–3728CrossRef
9.
Zurück zum Zitat Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195.CrossRef Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195.CrossRef
10.
Zurück zum Zitat Jaspan ON, Fleysher R, Lipton ML (2015) Compressed sensing MRI: a review of the clinical literature. Br J Radiol 88:20150487.CrossRef Jaspan ON, Fleysher R, Lipton ML (2015) Compressed sensing MRI: a review of the clinical literature. Br J Radiol 88:20150487.CrossRef
11.
Zurück zum Zitat Yang AC, Kretzler M, Sudarski S, Gulani V, Seiberlich N (2016) Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption. Invest Radiol 51:349–364.CrossRef Yang AC, Kretzler M, Sudarski S, Gulani V, Seiberlich N (2016) Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption. Invest Radiol 51:349–364.CrossRef
12.
Zurück zum Zitat Feng L, Benkert T, Block KT, Sodickson DK, Otazo R, Chandarana H (2017) Compressed sensing for body MRI: Compressed Sensing for Body MRI. J Magn Reson Imaging 45:966–987.CrossRef Feng L, Benkert T, Block KT, Sodickson DK, Otazo R, Chandarana H (2017) Compressed sensing for body MRI: Compressed Sensing for Body MRI. J Magn Reson Imaging 45:966–987.CrossRef
13.
Zurück zum Zitat Runge VM, Richter JK, Heverhagen JT (2017) Speed in Clinical Magnetic Resonance: Invest Radiol 52:1–17.PubMed Runge VM, Richter JK, Heverhagen JT (2017) Speed in Clinical Magnetic Resonance: Invest Radiol 52:1–17.PubMed
14.
Zurück zum Zitat Chandarana H, Doshi AM, Shanbhogue A, et al (2016) Three-dimensional MR Cholangiopancreatography in a Breath Hold with Sparsity-based Reconstruction of Highly Undersampled Data. Radiology 280:585–594.CrossRef Chandarana H, Doshi AM, Shanbhogue A, et al (2016) Three-dimensional MR Cholangiopancreatography in a Breath Hold with Sparsity-based Reconstruction of Highly Undersampled Data. Radiology 280:585–594.CrossRef
15.
Zurück zum Zitat Taron J, Weiss J, Notohamiprodjo M, et al. (2018) Acceleration of Magnetic Resonance Cholangiopancreatography Using Compressed Sensing at 1.5 and 3 T: A Clinical Feasibility Study. Invest Radiol 53:681–688CrossRef Taron J, Weiss J, Notohamiprodjo M, et al. (2018) Acceleration of Magnetic Resonance Cholangiopancreatography Using Compressed Sensing at 1.5 and 3 T: A Clinical Feasibility Study. Invest Radiol 53:681–688CrossRef
16.
Zurück zum Zitat Zhu L, Wu X, Sun Z, et al (2017) Compressed-Sensing Accelerated 3-Dimensional Magnetic Resonance Cholangiopancreatography: Application in Suspected Pancreatic Diseases. Invest Radiol 53:150–157CrossRef Zhu L, Wu X, Sun Z, et al (2017) Compressed-Sensing Accelerated 3-Dimensional Magnetic Resonance Cholangiopancreatography: Application in Suspected Pancreatic Diseases. Invest Radiol 53:150–157CrossRef
17.
Zurück zum Zitat Yoon JH, Lee SM, Kang H-J, et al (2017) Clinical Feasibility of 3-Dimensional Magnetic Resonance Cholangiopancreatography Using Compressed Sensing: Comparison of Image Quality and Diagnostic Performance. Invest Radiol 52:612–619.CrossRef Yoon JH, Lee SM, Kang H-J, et al (2017) Clinical Feasibility of 3-Dimensional Magnetic Resonance Cholangiopancreatography Using Compressed Sensing: Comparison of Image Quality and Diagnostic Performance. Invest Radiol 52:612–619.CrossRef
18.
Zurück zum Zitat Zhu L, Xue H, Sun Z, et al (2018) Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: Clinical feasibility in biliary and pancreatic disorders. J Magn Reson Imaging 48:1389–1399CrossRef Zhu L, Xue H, Sun Z, et al (2018) Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: Clinical feasibility in biliary and pancreatic disorders. J Magn Reson Imaging 48:1389–1399CrossRef
19.
Zurück zum Zitat Seo N, Park M-S, Han K, et al (2017) Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T. J Magn Reson Imaging 46:1289–1297CrossRef Seo N, Park M-S, Han K, et al (2017) Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T. J Magn Reson Imaging 46:1289–1297CrossRef
20.
Zurück zum Zitat Taylor ACF, Little AF, Hennessy OF, Banting SW, Smith PJ, Desmond PV (2002) Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree. Gastrointest Endosc 55:17–22.CrossRef Taylor ACF, Little AF, Hennessy OF, Banting SW, Smith PJ, Desmond PV (2002) Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree. Gastrointest Endosc 55:17–22.CrossRef
21.
Zurück zum Zitat Worters PW, Sung K, Stevens KJ, Koch KM, Hargreaves BA (2013) Compressed-sensing multispectral imaging of the postoperative spine. J Magn Reson Imaging 37:243–248.CrossRef Worters PW, Sung K, Stevens KJ, Koch KM, Hargreaves BA (2013) Compressed-sensing multispectral imaging of the postoperative spine. J Magn Reson Imaging 37:243–248.CrossRef
22.
Zurück zum Zitat Sharma SD, Fong CL, Tzung BS, Law M, Nayak KS (2013) Clinical Image Quality Assessment of Accelerated Magnetic Resonance Neuroimaging Using Compressed Sensing: Invest Radiol 48:638–645.CrossRef Sharma SD, Fong CL, Tzung BS, Law M, Nayak KS (2013) Clinical Image Quality Assessment of Accelerated Magnetic Resonance Neuroimaging Using Compressed Sensing: Invest Radiol 48:638–645.CrossRef
Metadaten
Titel
Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders
verfasst von
Inès Mannes
Axel Dallongeville
Neesmah Badat
Hélène Beaussier
Gilles Chatellier
Marc Zins
Publikationsdatum
09.10.2019
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 4/2020
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-019-02254-2

Weitere Artikel der Ausgabe 4/2020

Abdominal Radiology 4/2020 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.