Skip to main content
Erschienen in: Annals of Vascular Surgery 2/2006

01.03.2006

The Relationship between Gestational Age and Compliance in Human Umbilical Vein and Its Possible Application in Vascular Grafting

verfasst von: Wenchun Li, MD, Tiezhu Huang, MD, Yanjun Zeng, PhD, Zhongjun Yao, MD

Erschienen in: Annals of Vascular Surgery | Ausgabe 2/2006

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to provide a theoretical basis, using biomechanical properties, for the clinical application of human umbilical vein (HUV) as material for vascular grafting. This was a nonrandomized, noncontrolled in vitro study. The experiment was conducted in the Laboratory of Medical Biomechanics, Yunyang Medical College. HUVs of 50 normal fetuses were collected on spontaneous miscarriage or labor with the pregnant women’s permission by the Department of Obstetrics and Gynecology, Taihe Hospital, Shiyan, Hubei Province. Gestational aged ranged 24-42 weeks, and parturients were 20-30 years old. The pressure-volume (P-V) relationship of HUV was measured on the biomechanical experiment stand for soft tissues, and then compliance was calculated. The P-V relationship of HUV corresponded to a parabolic curve. The compliance of HUV increased gradually with gestational age [24-27 weeks (2.22 ± 0.34) × 10−4 mL/(kPa • cm), 28-32 weeks (3.65 ± 0.46) × 10−4 mL/(kPa • cm), 33-36 weeks (4.22 ± 0.55) × 10−4 mL/(kPa • cm), 37 weeks (7.63 ± 0.48) × 10−4 mL/(kPa • cm), 38 weeks (8.32 ± 0.76) × 10−4 mL/(kPa • cm)]. However, after 39 weeks of gestation, compliance decreased gradually with gestational age [39 weeks 7.61 ± 0.46) × 10−4 mL/(kPa • cm), 40 weeks (7.53 ± 0.72) × 10−4 mL/(kPa • cm), 41 weeks (4.13 ± 0.35) × 10−4 mL/(kPa • cm), 42 weeks (2.25 ± 0.62) × 10−4 mL/(kPa • cm)]. The compliance of HUVs collected at 37-40 weeks of gestational age was similar. When the HUVs older than 42 weeks or under 28 weeks were compared, there was significant difference in their compliance (F = 65.84-86.52, p < 0.01). The results of the present study suggest that HUVs collected at 37-40 weeks of gestational age have good compliance, i.e., a good P-V relationship, and therefore may be a suitable material for vascular grafting. HUV is one of several graft materials that may be used when autogenous saphenous vein is absent or inadequate. HUV is very biocompatible and shows promise for use in orthopedic implants.
Literatur
1.
Zurück zum Zitat Heyligers JM, Arts CH, Verhagen HJ, de Groot PG, Moll FL. Improving small-diameter vascular grafts: from the application of an endothelial cell lining to the construction of a tissue-engineered blood vessel. Ann Vasc Surg 2005;19:448–456PubMedCrossRef Heyligers JM, Arts CH, Verhagen HJ, de Groot PG, Moll FL. Improving small-diameter vascular grafts: from the application of an endothelial cell lining to the construction of a tissue-engineered blood vessel. Ann Vasc Surg 2005;19:448–456PubMedCrossRef
2.
Zurück zum Zitat Stoltz JF, Lehalle B, Blondel WC, Bensoussan D, Paulus F. Introduction to vascular engineering. J Mal Vasc 2001;26:183–190PubMed Stoltz JF, Lehalle B, Blondel WC, Bensoussan D, Paulus F. Introduction to vascular engineering. J Mal Vasc 2001;26:183–190PubMed
3.
Zurück zum Zitat Nerem RM, Ensley AE. The tissue engineering of blood vessels and the heart. Am J Transplant 2004;4:36–42PubMedCrossRef Nerem RM, Ensley AE. The tissue engineering of blood vessels and the heart. Am J Transplant 2004;4:36–42PubMedCrossRef
4.
Zurück zum Zitat Liu SQ, Tieche C, Alkema PK. Neointima formation on vascular elastic laminae and collagen matrices scaffolds implanted in the rat aortae. Biomaterials 2004;25:1869–1882PubMedCrossRef Liu SQ, Tieche C, Alkema PK. Neointima formation on vascular elastic laminae and collagen matrices scaffolds implanted in the rat aortae. Biomaterials 2004;25:1869–1882PubMedCrossRef
5.
Zurück zum Zitat MacNeill BD, Pomerantseva I, Lowe HC, Oesterle SN, Vacanti JP. Toward a new blood vessel. Vasc Med 2002;7:241–246PubMedCrossRef MacNeill BD, Pomerantseva I, Lowe HC, Oesterle SN, Vacanti JP. Toward a new blood vessel. Vasc Med 2002;7:241–246PubMedCrossRef
6.
Zurück zum Zitat Lamm P, Juchem G, Milz S, Schuffenhauer M, Reichart B. Autologous endothelialized vein allograft: a solution in the search for small-caliber grafts in coronary artery bypass graft operations. Circulation 2001;104(Suppl 1):I108–I114PubMed Lamm P, Juchem G, Milz S, Schuffenhauer M, Reichart B. Autologous endothelialized vein allograft: a solution in the search for small-caliber grafts in coronary artery bypass graft operations. Circulation 2001;104(Suppl 1):I108–I114PubMed
7.
Zurück zum Zitat Calles-Vazquez MC, Uson JM, Viguera FJ, Sun F, Paz JI, Uson-Gargallo J. Vascular closure stapler clips versus polypropylene sutures in end-to-end anastomoses of growing arteries and veins. Ann Vasc Surg 2005;19:320–327PubMedCrossRef Calles-Vazquez MC, Uson JM, Viguera FJ, Sun F, Paz JI, Uson-Gargallo J. Vascular closure stapler clips versus polypropylene sutures in end-to-end anastomoses of growing arteries and veins. Ann Vasc Surg 2005;19:320–327PubMedCrossRef
8.
Zurück zum Zitat Sierra J, Beghetti M, Kalangos A. Truncus arteriosus repair with double aortic homograft. J Card Surg 2004;19:252–253PubMedCrossRef Sierra J, Beghetti M, Kalangos A. Truncus arteriosus repair with double aortic homograft. J Card Surg 2004;19:252–253PubMedCrossRef
9.
Zurück zum Zitat Pascual G, Martinez S, Garcia-Honduvilla N, Corrales C, Bellon JM, Bujan J. Long-term behaviour of cryopreserved arterial grafts versus prosthetic micrografts. Eur. J Vasc Endovasc Surg 2004;27:423–431PubMedCrossRef Pascual G, Martinez S, Garcia-Honduvilla N, Corrales C, Bellon JM, Bujan J. Long-term behaviour of cryopreserved arterial grafts versus prosthetic micrografts. Eur. J Vasc Endovasc Surg 2004;27:423–431PubMedCrossRef
10.
Zurück zum Zitat Nishinari K, Wolosker N, Yazbek G, et al. Vascular reconstruction in limbs associated with resection of tumors. Ann Vasc Surg 2003;17:411–416PubMedCrossRef Nishinari K, Wolosker N, Yazbek G, et al. Vascular reconstruction in limbs associated with resection of tumors. Ann Vasc Surg 2003;17:411–416PubMedCrossRef
11.
Zurück zum Zitat Dardik I, Dardik H. Vascular heterograft: human umbilical cord vein as an aortic substitute in baboon. A preliminary report J Med Primatol 1973;2:296–301 Dardik I, Dardik H. Vascular heterograft: human umbilical cord vein as an aortic substitute in baboon. A preliminary report J Med Primatol 1973;2:296–301
12.
Zurück zum Zitat Dardik H, Wengerter K, Qin F, et al. Comparative decades of experience with glutaraldehyde-tanned human umbilical cord vein graft for lower limb revascularization: an analysis of 1275 cases. J Vasc Surg 2002;35:64–71PubMed Dardik H, Wengerter K, Qin F, et al. Comparative decades of experience with glutaraldehyde-tanned human umbilical cord vein graft for lower limb revascularization: an analysis of 1275 cases. J Vasc Surg 2002;35:64–71PubMed
13.
Zurück zum Zitat Vlessis AA, Hovaguimian H, Arntson E, Starr A. Use of autologous umbilical artery and vein for vascular reconstruction in the newborn. J Thorac Cardiovasc Surg. 1995;109:854–857PubMedCrossRef Vlessis AA, Hovaguimian H, Arntson E, Starr A. Use of autologous umbilical artery and vein for vascular reconstruction in the newborn. J Thorac Cardiovasc Surg. 1995;109:854–857PubMedCrossRef
14.
Zurück zum Zitat Aslan R, Sevin B, Dernek S, Manti Z. Human umbilical cord vein grafts for replacement of the superior vena cava. J Cardiovasc Surg (Torino) 1992;33:154–159 Aslan R, Sevin B, Dernek S, Manti Z. Human umbilical cord vein grafts for replacement of the superior vena cava. J Cardiovasc Surg (Torino) 1992;33:154–159
15.
Zurück zum Zitat Pennati G. Biomechanical properties of the human umbilical cord. Biorheology 2001;38:355–366PubMed Pennati G. Biomechanical properties of the human umbilical cord. Biorheology 2001;38:355–366PubMed
16.
Zurück zum Zitat Li W, Huang T, Zeng F, Zhou L. Biomechanical properties of human umbilical vessels at different gestational ages and their clinical significanc. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 2001;18:530–533PubMed Li W, Huang T, Zeng F, Zhou L. Biomechanical properties of human umbilical vessels at different gestational ages and their clinical significanc. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 2001;18:530–533PubMed
17.
18.
Zurück zum Zitat Li WC, Wang J, Tang J. Quantitative analysis of histological structure of umbilical cord vein for assessing the feasibility as arteriole transplantation substitute. ZhongGuo Lin Chuang Kang Fu 2005;9:216–219 Li WC, Wang J, Tang J. Quantitative analysis of histological structure of umbilical cord vein for assessing the feasibility as arteriole transplantation substitute. ZhongGuo Lin Chuang Kang Fu 2005;9:216–219
19.
Zurück zum Zitat Lanne T, Sonesson B, Bergqvist D, Bengtsson H, Gustafsson D. Diameter and compliance in the male human abdominal aorta: influence of age and aortic aneurysm. Eur. J. Vasc. Surg. 1992;6:178–184PubMedCrossRef Lanne T, Sonesson B, Bergqvist D, Bengtsson H, Gustafsson D. Diameter and compliance in the male human abdominal aorta: influence of age and aortic aneurysm. Eur. J. Vasc. Surg. 1992;6:178–184PubMedCrossRef
20.
Zurück zum Zitat Dardik H, Dardik II. Successful arterial substitution with modified human umbilical vein Ann Surg 1976;183:252–258PubMedCrossRef Dardik H, Dardik II. Successful arterial substitution with modified human umbilical vein Ann Surg 1976;183:252–258PubMedCrossRef
21.
Zurück zum Zitat Dardik H, Miller N, Dardik A, Ibrahim IM. A decade of experience with the glutaraldehyde-tanned human umbilical cord vein graft for revascularization of the lower limb. J Vasc Surg 1998;7:336–346CrossRef Dardik H, Miller N, Dardik A, Ibrahim IM. A decade of experience with the glutaraldehyde-tanned human umbilical cord vein graft for revascularization of the lower limb. J Vasc Surg 1998;7:336–346CrossRef
22.
Zurück zum Zitat Anderson LI, Nielson OM, Hansen Buchardt HJ. Umbilical vein bypass in patients with severe lower limb ischemia: a report of 121 consecutive cases. Surgery 1985;97:294–299 Anderson LI, Nielson OM, Hansen Buchardt HJ. Umbilical vein bypass in patients with severe lower limb ischemia: a report of 121 consecutive cases. Surgery 1985;97:294–299
23.
Zurück zum Zitat Daniel J, Abe K, McFetridge PS. Development of the human umbilical vein scaffold for cardiovascular tissue engineering applications. ASAIO J. 2005;51:252–261PubMedCrossRef Daniel J, Abe K, McFetridge PS. Development of the human umbilical vein scaffold for cardiovascular tissue engineering applications. ASAIO J. 2005;51:252–261PubMedCrossRef
24.
Zurück zum Zitat Johnson WC, Lee KK. A comparative evaluation of polytetrafluoroethylene, umbilical vein, and saphenous vein bypass grafts for femoral-popliteal above-knee revascularization: a prospective randomized Department of Veterans Affairs cooperative study. J Vasc Surg 2000;32:268–277PubMedCrossRef Johnson WC, Lee KK. A comparative evaluation of polytetrafluoroethylene, umbilical vein, and saphenous vein bypass grafts for femoral-popliteal above-knee revascularization: a prospective randomized Department of Veterans Affairs cooperative study. J Vasc Surg 2000;32:268–277PubMedCrossRef
25.
Zurück zum Zitat Morasch MD, Dobrin PB, Dong QS, Mrkvicka R. Mechanics of spatulated end-to-end artery-to-vein anastomoses. Ann Vasc Surg 1998;12:55–59PubMedCrossRef Morasch MD, Dobrin PB, Dong QS, Mrkvicka R. Mechanics of spatulated end-to-end artery-to-vein anastomoses. Ann Vasc Surg 1998;12:55–59PubMedCrossRef
26.
Zurück zum Zitat Haruguchi H, Teraoka S. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review. J Artif Organs 2003;6:227–235PubMedCrossRef Haruguchi H, Teraoka S. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review. J Artif Organs 2003;6:227–235PubMedCrossRef
27.
Zurück zum Zitat Huang TZ, Chen EY, Yu HY. Changes of compliance and morphology of human brachial artery at different elongations and their clinical significance. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 1995;12:295–299 Huang TZ, Chen EY, Yu HY. Changes of compliance and morphology of human brachial artery at different elongations and their clinical significance. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 1995;12:295–299
28.
Zurück zum Zitat Yu HY, Chen EY, Zhu XH. Compliance changes of human femoral arterial segment after stretching. Zhongguo Sheng Wu Yi Xue Gong Cheng Xue Bao 1993;12:285–289 Yu HY, Chen EY, Zhu XH. Compliance changes of human femoral arterial segment after stretching. Zhongguo Sheng Wu Yi Xue Gong Cheng Xue Bao 1993;12:285–289
29.
Zurück zum Zitat Stooker W, Gok M, Sipkema P, Niessen HW, Baidoshvili A, Westerhof N. Pressure-diameter relationship in the human greater saphenous vein. Ann Thorac Surg 2003;76:1533–1538PubMedCrossRef Stooker W, Gok M, Sipkema P, Niessen HW, Baidoshvili A, Westerhof N. Pressure-diameter relationship in the human greater saphenous vein. Ann Thorac Surg 2003;76:1533–1538PubMedCrossRef
Metadaten
Titel
The Relationship between Gestational Age and Compliance in Human Umbilical Vein and Its Possible Application in Vascular Grafting
verfasst von
Wenchun Li, MD
Tiezhu Huang, MD
Yanjun Zeng, PhD
Zhongjun Yao, MD
Publikationsdatum
01.03.2006
Verlag
Springer-Verlag
Erschienen in
Annals of Vascular Surgery / Ausgabe 2/2006
Print ISSN: 0890-5096
Elektronische ISSN: 1615-5947
DOI
https://doi.org/10.1007/s10016-006-9020-4

Weitere Artikel der Ausgabe 2/2006

Annals of Vascular Surgery 2/2006 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.