Skip to main content
Erschienen in: Clinical Oral Investigations 9/2022

22.07.2022 | Original Article

Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology

verfasst von: Fatih Demirci, Erkan Bahce, Melike Cigdem Baran

Erschienen in: Clinical Oral Investigations | Ausgabe 9/2022

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The aim of this study was to evaluate the mechanical analysis of different three-unit metal-free fixed dental prostheses (FDPs) produced by computer-aided design (CAD)/computer-aided manufacturing (CAM).

Materials and methods

A hundred stainless steel die models of a mandibular left first premolar and a mandibular left first molar were prepared. The specimens were divided into five CAD/CAM material groups (n = 20): Group ZIR, a cubic zirconia (DD cube ONE®); Group FRC, FRC resin material (Trinia); Group PEEK, a PEEK material (KERA® starPEEK); Group PEKK, a PEKK material (Pekkton® ivory); and Group COMP, a polymer composite material (BreCAM.HIPC). Compression test was applied to the specimens, and then the results were analyzed statistically using one-way ANOVA and Tukey’s tests. In addition, deformation analyses in FDPs were compared with finite element method (FEM). After the compression test, the damage to FDPs was evaluated with a scanning electron microscopy.

Results

Although ZIR (2461 ± 93.70 N) showed high fracture load values, FRC (1571 ± 35.96 N) material was found to be advantageous in terms of toughness. These were followed by PEEK (1398 ± 38.26 N), PEKK (1227 ± 44.25 N), and COMP (829 ± 32.33 N), respectively. A ductile fracture was observed in PEEK, PEKK, and FRC due to their elastic structures. The deformation properties examined by the FEM were found to be similar to the compression test.

Conclusions

CAD/CAM high-performance polymers and cubic zirconia material can be used in three-unit FDPs. In three-unit FDPs, the use of FRC material can be advantageous due to both biomechanics and lightness.

Clinical relevance

Metal-free CAD/CAM materials may offer new possibilities in three-unit FDPs.
Literatur
1.
Zurück zum Zitat Preis V, Hahnel S, Behr M, Bein L, Rosentritt M (2017) In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater 33(4):427–433CrossRef Preis V, Hahnel S, Behr M, Bein L, Rosentritt M (2017) In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater 33(4):427–433CrossRef
2.
Zurück zum Zitat Lambert H, Durand JC, Jacquot B, Fages M (2017) Dental biomaterials for chairside CAD/CAM: State of the art. J Adv Prosthodont 9(6):486–495CrossRef Lambert H, Durand JC, Jacquot B, Fages M (2017) Dental biomaterials for chairside CAD/CAM: State of the art. J Adv Prosthodont 9(6):486–495CrossRef
3.
Zurück zum Zitat Denry I, Kelly JR (2014) Emerging ceramic-based materials for dentistry. J Dent Res 93(12):1235–1242CrossRef Denry I, Kelly JR (2014) Emerging ceramic-based materials for dentistry. J Dent Res 93(12):1235–1242CrossRef
4.
Zurück zum Zitat Pereira GKR, Guilardi LF, Dapieve KS, Kleverlaan CJ, Rippe MP, Valandro LF (2018) Mechanical reliability, fatigue strength and survival analysis of new polycrystalline translucent zirconia ceramics for monolithic restorations. J Mech Behav Biomed Mater 85:57–65CrossRef Pereira GKR, Guilardi LF, Dapieve KS, Kleverlaan CJ, Rippe MP, Valandro LF (2018) Mechanical reliability, fatigue strength and survival analysis of new polycrystalline translucent zirconia ceramics for monolithic restorations. J Mech Behav Biomed Mater 85:57–65CrossRef
5.
Zurück zum Zitat Yilmaz B, Batak B, Seghi RR (2019) Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses. Clin Implant Dent Relat Res 21(6):1132–1139CrossRef Yilmaz B, Batak B, Seghi RR (2019) Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses. Clin Implant Dent Relat Res 21(6):1132–1139CrossRef
6.
Zurück zum Zitat Stawarczyk B, Keul C, Eichberger M, Figge D, Edelhoff D, Lümkemann N (2017) Three generations of zirconia: from veneered to monolithic. Part I Quintessence Int 48(5):369–380PubMed Stawarczyk B, Keul C, Eichberger M, Figge D, Edelhoff D, Lümkemann N (2017) Three generations of zirconia: from veneered to monolithic. Part I Quintessence Int 48(5):369–380PubMed
7.
Zurück zum Zitat Alqurashi H, Khurshid Z, Syed AUY, Rashid Habib S, Rokaya D, Zafar MS (2020) Polyetherketoneketone (PEKK): AN emerging biomaterial for oral implants and dental prostheses. J Adv Res 28:87–95CrossRef Alqurashi H, Khurshid Z, Syed AUY, Rashid Habib S, Rokaya D, Zafar MS (2020) Polyetherketoneketone (PEKK): AN emerging biomaterial for oral implants and dental prostheses. J Adv Res 28:87–95CrossRef
8.
Zurück zum Zitat Erkmen E, Meriç G, Kurt A, Tunç Y, Eser A (2011) Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study. J Mech Behav Biomed Mater 4(1):107–116CrossRef Erkmen E, Meriç G, Kurt A, Tunç Y, Eser A (2011) Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study. J Mech Behav Biomed Mater 4(1):107–116CrossRef
9.
Zurück zum Zitat Najeeb S, Zafar MS, Khurshid Z, Siddiqui F (2016) Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 60(1):12–19CrossRef Najeeb S, Zafar MS, Khurshid Z, Siddiqui F (2016) Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 60(1):12–19CrossRef
10.
Zurück zum Zitat Ahmed KE, Li KY, Murray CA (2017) Longevity of fiber-reinforced composite fixed partial dentures (FRC FPD)-Systematic review. J Dent 61:1–11CrossRef Ahmed KE, Li KY, Murray CA (2017) Longevity of fiber-reinforced composite fixed partial dentures (FRC FPD)-Systematic review. J Dent 61:1–11CrossRef
11.
Zurück zum Zitat Bergamo ETP, Bastos TMC, Lopes ACO, de Araujo Júnior ENS, Coelho PG, Benalcazar Jalkh EB, Zahoui A, Bonfante EA (2021) Physicochemical and mechanical characterization of a fiber-reinforced composite used as frameworks of implant-supported prostheses. Dent Mater 37(8):e443–e453CrossRef Bergamo ETP, Bastos TMC, Lopes ACO, de Araujo Júnior ENS, Coelho PG, Benalcazar Jalkh EB, Zahoui A, Bonfante EA (2021) Physicochemical and mechanical characterization of a fiber-reinforced composite used as frameworks of implant-supported prostheses. Dent Mater 37(8):e443–e453CrossRef
12.
Zurück zum Zitat Bonfante EA, Suzuki M, Carvalho RM, Hirata R, Lubelski W, Bonfante G, Pegoraro TA, Coelho PG (2015) Digitally produced fiber-reinforced composite substructures for three-unit implant-supported fixed dental prostheses. Int J Oral Maxillofac Implants 30(2):321–329CrossRef Bonfante EA, Suzuki M, Carvalho RM, Hirata R, Lubelski W, Bonfante G, Pegoraro TA, Coelho PG (2015) Digitally produced fiber-reinforced composite substructures for three-unit implant-supported fixed dental prostheses. Int J Oral Maxillofac Implants 30(2):321–329CrossRef
13.
Zurück zum Zitat Jovanović M, Živić M, Milosavljević M (2021) A potential application of materials based on a polymer and CAD/CAM composite resins in prosthetic dentistry. J Prosthodont Res 65(2):137–147CrossRef Jovanović M, Živić M, Milosavljević M (2021) A potential application of materials based on a polymer and CAD/CAM composite resins in prosthetic dentistry. J Prosthodont Res 65(2):137–147CrossRef
14.
Zurück zum Zitat Niem T, Youssef N, Wöstmann B (2019) Energy dissipation capacities of CAD-CAM restorative materials: a comparative evaluation of resilience and toughness. J Prosthet Dent 121(1):101–109CrossRef Niem T, Youssef N, Wöstmann B (2019) Energy dissipation capacities of CAD-CAM restorative materials: a comparative evaluation of resilience and toughness. J Prosthet Dent 121(1):101–109CrossRef
15.
Zurück zum Zitat Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR (2013) Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 101(7):1209–1216CrossRef Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR (2013) Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 101(7):1209–1216CrossRef
16.
Zurück zum Zitat Amelya A, Kim JE, Woo CW, Otgonbold J, Lee KW (2019) Load-bearing capacity of posterior CAD/CAM implant-supported fixed partial dentures fabricated with different esthetic materials. Int J Prosthodont 32(2):201–204CrossRef Amelya A, Kim JE, Woo CW, Otgonbold J, Lee KW (2019) Load-bearing capacity of posterior CAD/CAM implant-supported fixed partial dentures fabricated with different esthetic materials. Int J Prosthodont 32(2):201–204CrossRef
17.
Zurück zum Zitat Rodríguez V, Tobar C, López-Suárez C, Peláez J, Suárez MJ (2021) Fracture load of metal, zirconia and polyetheretherketone posterior CAD-CAM milled fixed partial denture frameworks. Materials (Basel) 14(4):959CrossRef Rodríguez V, Tobar C, López-Suárez C, Peláez J, Suárez MJ (2021) Fracture load of metal, zirconia and polyetheretherketone posterior CAD-CAM milled fixed partial denture frameworks. Materials (Basel) 14(4):959CrossRef
18.
Zurück zum Zitat Stawarczyk B, Eichberger M, Uhrenbacher J, Wimmer T, Edelhoff D, Schmidlin PR (2015) Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J 34(1):7–12CrossRef Stawarczyk B, Eichberger M, Uhrenbacher J, Wimmer T, Edelhoff D, Schmidlin PR (2015) Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J 34(1):7–12CrossRef
19.
Zurück zum Zitat Corbani K, Hardan L, Eid R, Skienhe H, Alharbi N, Ozcan M, Salameh Z (2021) Fracture resistance of three-unit fixed dental prostheses fabricated with milled and 3D printed composite-based materials. J Contemp Dent Pract 22(9):985–990CrossRef Corbani K, Hardan L, Eid R, Skienhe H, Alharbi N, Ozcan M, Salameh Z (2021) Fracture resistance of three-unit fixed dental prostheses fabricated with milled and 3D printed composite-based materials. J Contemp Dent Pract 22(9):985–990CrossRef
20.
Zurück zum Zitat Mayinger F, Pfefferle R, Reichert A, Stawarczyk B (2021) Impact of high-speed sintering of three-unit 3Y-TZP and 4Y-TZP fixed dental prostheses on fracture load with and without artificial aging. Int J Prosthodont 34(1):47–53CrossRef Mayinger F, Pfefferle R, Reichert A, Stawarczyk B (2021) Impact of high-speed sintering of three-unit 3Y-TZP and 4Y-TZP fixed dental prostheses on fracture load with and without artificial aging. Int J Prosthodont 34(1):47–53CrossRef
21.
Zurück zum Zitat López-Suárez C, Castillo-Oyagüe R, Rodríguez-Alonso V, Lynch CD, Suárez-García MJ (2018) Fracture load of metal-ceramic, monolithic, and bi-layered zirconia-based posterior fixed dental prostheses after thermo-mechanical cycling. J Dent 73:97–104CrossRef López-Suárez C, Castillo-Oyagüe R, Rodríguez-Alonso V, Lynch CD, Suárez-García MJ (2018) Fracture load of metal-ceramic, monolithic, and bi-layered zirconia-based posterior fixed dental prostheses after thermo-mechanical cycling. J Dent 73:97–104CrossRef
22.
Zurück zum Zitat Campaner LM, Silveira MPM, de Andrade GS, Borges ALS, Bottino MA, Dal Piva AMO, Lo Giudice R, Ausiello P, Tribst JPM (2021) Influence of polymeric restorative materials on the stress distribution in posterior fixed partial dentures: 3D finite element analysis. Polymers (Basel) 13(5):758CrossRef Campaner LM, Silveira MPM, de Andrade GS, Borges ALS, Bottino MA, Dal Piva AMO, Lo Giudice R, Ausiello P, Tribst JPM (2021) Influence of polymeric restorative materials on the stress distribution in posterior fixed partial dentures: 3D finite element analysis. Polymers (Basel) 13(5):758CrossRef
23.
Zurück zum Zitat Rayyan MM, Abdallah J, Segaan LG, Bonfante EA, Osman E (2020) Static and fatigue loading of veneered implant-supported fixed dental prostheses. J Prosthodont 29(8):679–685CrossRef Rayyan MM, Abdallah J, Segaan LG, Bonfante EA, Osman E (2020) Static and fatigue loading of veneered implant-supported fixed dental prostheses. J Prosthodont 29(8):679–685CrossRef
24.
Zurück zum Zitat Partiyan A, Osman E, Rayyan MM, Aboushelib M, Ibrahim A, Jimbo R (2017) Fracture resistance of three-unit zirconia fixed partial denture with modified framework. Odontology 105(1):62–67CrossRef Partiyan A, Osman E, Rayyan MM, Aboushelib M, Ibrahim A, Jimbo R (2017) Fracture resistance of three-unit zirconia fixed partial denture with modified framework. Odontology 105(1):62–67CrossRef
25.
Zurück zum Zitat Abad-Coronel C, Carrera E, MenaCórdova N, Fajardo JI, Aliaga P (2021) Comparative analysis of fracture resistance between CAD/CAM materials for interim fixed prosthesis. Materials (Basel) 14(24):7791CrossRef Abad-Coronel C, Carrera E, MenaCórdova N, Fajardo JI, Aliaga P (2021) Comparative analysis of fracture resistance between CAD/CAM materials for interim fixed prosthesis. Materials (Basel) 14(24):7791CrossRef
26.
Zurück zum Zitat Dayan SC, Geckili O (2021) The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis. Comput Methods Biomech Biomed Engin 24(14):1606–1617CrossRef Dayan SC, Geckili O (2021) The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis. Comput Methods Biomech Biomed Engin 24(14):1606–1617CrossRef
27.
Zurück zum Zitat Zhang Y, Lawn BR (2018) Novel Zirconia Materials in Dentistry. J Dent Res 97(2):140–147CrossRef Zhang Y, Lawn BR (2018) Novel Zirconia Materials in Dentistry. J Dent Res 97(2):140–147CrossRef
28.
Zurück zum Zitat Cevik P, Schimmel M, Yilmaz B (2022) New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies. Biomed Res Int 2(2022):3074182 Cevik P, Schimmel M, Yilmaz B (2022) New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies. Biomed Res Int 2(2022):3074182
29.
Zurück zum Zitat Soares PM, Cadore-Rodrigues AC, Souto Borges AL, Valandro LF, Pereira GKR, Rippe MP (2021) Load-bearing capacity under fatigue and FEA analysis of simplified ceramic restorations supported by Peek or zirconia polycrystals as foundation substrate for implant purposes. J Mech Behav Biomed Mater 123:10476CrossRef Soares PM, Cadore-Rodrigues AC, Souto Borges AL, Valandro LF, Pereira GKR, Rippe MP (2021) Load-bearing capacity under fatigue and FEA analysis of simplified ceramic restorations supported by Peek or zirconia polycrystals as foundation substrate for implant purposes. J Mech Behav Biomed Mater 123:10476CrossRef
30.
Zurück zum Zitat Gibbs CH, Mahan PE, Lundeen HC, Brehnan K, Walsh EK, Holbrook WB (1981) Occlusal forces during chewing and swallowing as measured by sound transmission. J Prosthet Dent 46:443–449CrossRef Gibbs CH, Mahan PE, Lundeen HC, Brehnan K, Walsh EK, Holbrook WB (1981) Occlusal forces during chewing and swallowing as measured by sound transmission. J Prosthet Dent 46:443–449CrossRef
31.
Zurück zum Zitat Waltimo A, Kononen M (1993) A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res 101:171–175PubMed Waltimo A, Kononen M (1993) A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res 101:171–175PubMed
32.
Zurück zum Zitat Hensel F, Koenig A, Doerfler HM, Fuchs F, Rosentritt M, Hahnel S (2021) CAD/CAM Resin-based composites for use in long-term temporary fixed dental prostheses. Polymers (Basel) 13(20):3469CrossRef Hensel F, Koenig A, Doerfler HM, Fuchs F, Rosentritt M, Hahnel S (2021) CAD/CAM Resin-based composites for use in long-term temporary fixed dental prostheses. Polymers (Basel) 13(20):3469CrossRef
33.
Zurück zum Zitat Zimmermann M, Ender A, Attin T, Mehl A (2020) Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology. Clin Oral Investig 24(2):1035–1042CrossRef Zimmermann M, Ender A, Attin T, Mehl A (2020) Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology. Clin Oral Investig 24(2):1035–1042CrossRef
34.
Zurück zum Zitat Rosentritt M, Behr M, Gebhard R, Handel G (2006) Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dent Mater 22(2):176–182CrossRef Rosentritt M, Behr M, Gebhard R, Handel G (2006) Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dent Mater 22(2):176–182CrossRef
35.
Zurück zum Zitat Özcan M, Jonasch M (2018) Effect of cyclic fatigue tests on aging and their translational implications for survival of all-ceramic tooth-borne single crowns and fixed dental prostheses. J Prosthodont 27(4):364–375CrossRef Özcan M, Jonasch M (2018) Effect of cyclic fatigue tests on aging and their translational implications for survival of all-ceramic tooth-borne single crowns and fixed dental prostheses. J Prosthodont 27(4):364–375CrossRef
36.
Zurück zum Zitat Wimmer T, Erdelt KJ, Eichberger M, Roos M, Edelhoff D, Stawarczyk B (2014) Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses. Dent Mater J 33(6):717–724CrossRef Wimmer T, Erdelt KJ, Eichberger M, Roos M, Edelhoff D, Stawarczyk B (2014) Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses. Dent Mater J 33(6):717–724CrossRef
37.
Zurück zum Zitat Wimmer T, Ender A, Roos M, Stawarczyk B (2013) Fracture load of milled polymeric fixed dental prostheses as a function of connector cross-sectional areas. J Prosthet Dent 110(4):288–295CrossRef Wimmer T, Ender A, Roos M, Stawarczyk B (2013) Fracture load of milled polymeric fixed dental prostheses as a function of connector cross-sectional areas. J Prosthet Dent 110(4):288–295CrossRef
Metadaten
Titel
Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology
verfasst von
Fatih Demirci
Erkan Bahce
Melike Cigdem Baran
Publikationsdatum
22.07.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 9/2022
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-022-04623-6

Weitere Artikel der Ausgabe 9/2022

Clinical Oral Investigations 9/2022 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.