Purpose

This investigation was an observational study designed to evaluate the newly developed GlideScope video laryngoscope (GVL) and to assess its ability both to provide a laryngeal view and to facilitate intubation.

Principal findings

The study, which was conducted from November 2001 to March 2003, included 133 operators from five centres (Ontario and British Columbia, Canada and Washington State, USA) involving 728 patients. The resulting Cormack-Lehane (C/L) laryngeal exposure was excellent (1) in 92% of patients and good (2) in 7% of patients. The GVL provided a comparable or superior view in the 133 patients in whom both the GVL and the direct laryngoscope (DL) were used. Among the 35 patients with a C/L grade ≥ 3 view with the DL, the view improved to a C/L grade 1 view in 24 patients and a C/L grade 2 view in three patients. Tracheal intubation with the GVL was successful in 96.3% of patients and failed in 3.7%. Fifty-four percent of the failed intubations occurred despite achieving a C/L grade 1 view and resulted from the inability to direct the endotracheal tube toward a clearly seen larynx.

Conclusions

The GVL consistently yielded a comparable or superior glottic view compared with the DL despite the operators’ limited or lack of prior experience with the device. Successful intubation was typically achieved even when direct laryngoscopy was predicted to be moderately or considerably difficult. Not only was the GVL a novice-friendly device, this novel study also suggested that a video laryngoscope might provide superior performance when compared with the DL, particularly in patients in whom the DL provided a poor laryngeal view.
Fußnoten
1
Jack Pacey, personal communication.
 
Literatur
1.
Zurück zum Zitat Mort TC. Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts. Anesth Analg 2004; 99: 607-13.PubMedCrossRef Mort TC. Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts. Anesth Analg 2004; 99: 607-13.PubMedCrossRef
2.
Zurück zum Zitat Hung OR, Pytka S, Morris I, Murphy M, Stewart RD. Lightwand intubation: II - Clinical trial of a new lightwand for tracheal intubation in patients with difficult airways. Can J Anaesth 1995; 42: 826-30.PubMedCrossRef Hung OR, Pytka S, Morris I, Murphy M, Stewart RD. Lightwand intubation: II - Clinical trial of a new lightwand for tracheal intubation in patients with difficult airways. Can J Anaesth 1995; 42: 826-30.PubMedCrossRef
3.
4.
Zurück zum Zitat Shulman GB, Nordin NG, Connelly NR. Teaching with a video system improves the training period but not the subsequent success of tracheal intubation with the Bullard laryngoscope. Anesthesiology 2003; 98: 615-20.PubMedCrossRef Shulman GB, Nordin NG, Connelly NR. Teaching with a video system improves the training period but not the subsequent success of tracheal intubation with the Bullard laryngoscope. Anesthesiology 2003; 98: 615-20.PubMedCrossRef
5.
Zurück zum Zitat Kaplan MB, Ward DS, Berci G. A new video laryngoscope – an aide to intubation and teaching. J Clin Anesth 2002; 14: 620-6.PubMedCrossRef Kaplan MB, Ward DS, Berci G. A new video laryngoscope – an aide to intubation and teaching. J Clin Anesth 2002; 14: 620-6.PubMedCrossRef
6.
Zurück zum Zitat Jungbauer A, Schumann M, Brunkhorst V, Borgers A, Groeben H. Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients. Br J Anaesth 2009; 102: 546-50.PubMedCrossRef Jungbauer A, Schumann M, Brunkhorst V, Borgers A, Groeben H. Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients. Br J Anaesth 2009; 102: 546-50.PubMedCrossRef
7.
Zurück zum Zitat Cooper RM. Use of a new videolaryngoscope (GlideScope®) in the management of a difficult airway. Can J Anesth 2003; 50: 611-3.PubMedCrossRef Cooper RM. Use of a new videolaryngoscope (GlideScope®) in the management of a difficult airway. Can J Anesth 2003; 50: 611-3.PubMedCrossRef
8.
Zurück zum Zitat Agro F, Barzoi G, Montecchia F. Tracheal intubation using a Macintosh laryngoscope or GlideScope® in 15 patients with cervical spine immobilization. Br J Anaesth 2003; 90: 705-6.PubMedCrossRef Agro F, Barzoi G, Montecchia F. Tracheal intubation using a Macintosh laryngoscope or GlideScope® in 15 patients with cervical spine immobilization. Br J Anaesth 2003; 90: 705-6.PubMedCrossRef
9.
Zurück zum Zitat Cooper RM, Pacey JA, Bishop MJ, McCluskey SA. Early clinical experience with a new videolaryngoscope (GlideScope®) in 728 patients. Can J Anesth 2005; 52: 191-8.PubMedCrossRef Cooper RM, Pacey JA, Bishop MJ, McCluskey SA. Early clinical experience with a new videolaryngoscope (GlideScope®) in 728 patients. Can J Anesth 2005; 52: 191-8.PubMedCrossRef
10.
Zurück zum Zitat Sun DA, Warriner CB, Parsons DG, Klein R, Umedaly HS, Moult M. The GlideScope® Video Laryngoscope: randomized clinical trial in 200 patients. Br J Anaesth 2005; 94: 381-4.PubMedCrossRef Sun DA, Warriner CB, Parsons DG, Klein R, Umedaly HS, Moult M. The GlideScope® Video Laryngoscope: randomized clinical trial in 200 patients. Br J Anaesth 2005; 94: 381-4.PubMedCrossRef
11.
Zurück zum Zitat Fridrich P, Frass M, Krenn CG, Weinstabl C, Benumof JL, Krafft P. The UpsherScope™ in routine and difficult airway management: a randomized, controlled clinical trial. Anesth Analg 1997; 85: 1377-81.PubMedCrossRef Fridrich P, Frass M, Krenn CG, Weinstabl C, Benumof JL, Krafft P. The UpsherScope™ in routine and difficult airway management: a randomized, controlled clinical trial. Anesth Analg 1997; 85: 1377-81.PubMedCrossRef
12.
Zurück zum Zitat Griesdale DE, Liu D, McKinney J, Choi PT. Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Can J Anesth 2012; 59: 41-52.PubMedCentralPubMedCrossRef Griesdale DE, Liu D, McKinney J, Choi PT. Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Can J Anesth 2012; 59: 41-52.PubMedCentralPubMedCrossRef
13.
Zurück zum Zitat Healy DW, Maties O, Hovord D, Kheterpal S. A systematic review of the role of videolaryngoscopy in successful orotracheal intubation. BMC Anesthesiol 2012; 12: 32.PubMedCentralPubMedCrossRef Healy DW, Maties O, Hovord D, Kheterpal S. A systematic review of the role of videolaryngoscopy in successful orotracheal intubation. BMC Anesthesiol 2012; 12: 32.PubMedCentralPubMedCrossRef
14.
Zurück zum Zitat Kory P, Guevarra K, Mathew JP, Hegde A, Mayo PH. The impact of video laryngoscopy use during urgent endotracheal intubation in the critically ill. Anesth Analg 2013; 117: 144-9.PubMedCrossRef Kory P, Guevarra K, Mathew JP, Hegde A, Mayo PH. The impact of video laryngoscopy use during urgent endotracheal intubation in the critically ill. Anesth Analg 2013; 117: 144-9.PubMedCrossRef
15.
Zurück zum Zitat Aziz MF, Healy D, Kheterpal S, Fu RF, Dillman D, Brambrink AM. Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions. Anesthesiology 2011; 114: 34-41.PubMedCrossRef Aziz MF, Healy D, Kheterpal S, Fu RF, Dillman D, Brambrink AM. Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions. Anesthesiology 2011; 114: 34-41.PubMedCrossRef
Metadaten
Titel
From the Journal archives: Early clinical experience with a new video laryngoscope
verfasst von
Edward T. Crosby, MD
Publikationsdatum
01.05.2014
Verlag
Springer US
Erschienen in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Ausgabe 5/2014
Print ISSN: 0832-610X
Elektronische ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-013-0102-9

Weitere Artikel der Ausgabe 5/2014

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 5/2014 Zur Ausgabe

Book and New Media Reviews

Cancer pain

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Delir bei kritisch Kranken – Antipsychotika versus Placebo

16.05.2024 Delir Nachrichten

Um die Langzeitfolgen eines Delirs bei kritisch Kranken zu mildern, wird vielerorts auf eine Akuttherapie mit Antipsychotika gesetzt. Eine US-amerikanische Forschungsgruppe äußert jetzt erhebliche Vorbehalte gegen dieses Vorgehen. Denn es gibt neue Daten zum Langzeiteffekt von Haloperidol bzw. Ziprasidon versus Placebo.

Eingreifen von Umstehenden rettet vor Erstickungstod

15.05.2024 Fremdkörperaspiration Nachrichten

Wer sich an einem Essensrest verschluckt und um Luft ringt, benötigt vor allem rasche Hilfe. Dass Umstehende nur in jedem zweiten Erstickungsnotfall bereit waren, diese zu leisten, ist das ernüchternde Ergebnis einer Beobachtungsstudie aus Japan. Doch es gibt auch eine gute Nachricht.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.