Skip to main content
Erschienen in: International Orthopaedics 11/2013

01.11.2013 | Original Paper

A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty

verfasst von: Young-Hoo Kim, Jang-Won Park, Sourabh S. Kulkarni, Yoon-Hong Kim

Erschienen in: International Orthopaedics | Ausgabe 11/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Very few studies have compared alumina-on-alumina ceramic and alumina-on-highly cross-linked polyethylene bearings in the same patient. The purpose of this prospective randomised study was to compare the clinical and radiographic results and the prevalence of osteolysis in cementless total hip arthroplasty using an alumina-on-alumina and alumina-on-highly cross-linked polyethylene bearings in young active patients.

Methods

We prospectively compared the results of 100 patients (200 hips) who had undergone a cementless total hip arthroplasty with an alumina-on-alumina ceramic bearing in one hip and an alumina-on-highly cross-linked polyethylene in the other. There were 66 men and 34 women with a mean age of 45.3 years (range, 21–49 years) at the time of surgery. The mean follow-up was 12.4 years (range, 11–13 years). The patients were assessed clinically and radiographically at three months, one year, and annually thereafter.

Results

Harris hip, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles activity scores did not show statistically significant differences between the two groups of bearings preoperatively or at the time of final follow-up. Radiographic findings of the component were not significantly different between the two groups. The mean polyethylene linear penetration was 0.031 ± 0.004 mm per year. No hips in either group displayed osteolysis. The Kaplan-Meier survivorship with revision as the end point at 12.4 years was 100 % (95 % confidence interval [CI], 94–100 %) for the femoral component in both groups and 99 % (95 %CI, 93–100 %) for the acetabular component.

Conclusion

The clinical and radiographic results of using an alumina-on-alumina ceramic and alumina-on-highly cross-linked polyethylene bearings were similar.
Literatur
1.
Zurück zum Zitat Dowd JE, Sychterz CJ, Young AM, Engh CA (2000) Characterization of long-term femoral-head-penetration rates. Association with and prediction of osteolysis. J Bone Joint Surg Am 82(8):1102–1107PubMed Dowd JE, Sychterz CJ, Young AM, Engh CA (2000) Characterization of long-term femoral-head-penetration rates. Association with and prediction of osteolysis. J Bone Joint Surg Am 82(8):1102–1107PubMed
2.
Zurück zum Zitat Elfick AP, Hall RM, Pinder IM, Unsworth A (1998) Wear in retrieved acetabular components: effect of femoral head radius and patient parameters. J Arthroplasty 13(3):291–295PubMedCrossRef Elfick AP, Hall RM, Pinder IM, Unsworth A (1998) Wear in retrieved acetabular components: effect of femoral head radius and patient parameters. J Arthroplasty 13(3):291–295PubMedCrossRef
3.
Zurück zum Zitat Kim Y-H, Kim J-S, Choi Y-W, Kwon O-R (2009) Intermediate results of simultaneous alumina-on-alumina bearing and alumina-on-highly cross-linked polyethylene bearing total hip arthroplasties. J Arthroplasty 24(6):885–891PubMedCrossRef Kim Y-H, Kim J-S, Choi Y-W, Kwon O-R (2009) Intermediate results of simultaneous alumina-on-alumina bearing and alumina-on-highly cross-linked polyethylene bearing total hip arthroplasties. J Arthroplasty 24(6):885–891PubMedCrossRef
4.
Zurück zum Zitat Kim Y-H, Choi Y-W, Kim J-S (2011) Cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearing in young patients with femoral head osteonecrosis. J Arthroplasty 26(2):218–223PubMedCrossRef Kim Y-H, Choi Y-W, Kim J-S (2011) Cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearing in young patients with femoral head osteonecrosis. J Arthroplasty 26(2):218–223PubMedCrossRef
5.
Zurück zum Zitat Kim Y-H, Park J-W, Patel C, Kim D-Y (2013) Polyethylene wear and osteolysis after cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearings in patients younger than thirty tears of age. J Bone Joint Surg Am 95(12):1088–1093PubMedCrossRef Kim Y-H, Park J-W, Patel C, Kim D-Y (2013) Polyethylene wear and osteolysis after cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearings in patients younger than thirty tears of age. J Bone Joint Surg Am 95(12):1088–1093PubMedCrossRef
6.
Zurück zum Zitat Kim YH (2008) The results of a proximally-coated cementless femoral component in total hip replacement: a five- to 12-year follow-up. J Bone Joint Surg Br 90(3):299–305PubMed Kim YH (2008) The results of a proximally-coated cementless femoral component in total hip replacement: a five- to 12-year follow-up. J Bone Joint Surg Br 90(3):299–305PubMed
7.
Zurück zum Zitat Capello WN, D’Antonio JA, Feinberg JR, Manley MT, Naughton M (2008) Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty 23(7 Suppl):39–43PubMedCrossRef Capello WN, D’Antonio JA, Feinberg JR, Manley MT, Naughton M (2008) Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty 23(7 Suppl):39–43PubMedCrossRef
8.
Zurück zum Zitat Garvin KL, Hartman CW, Mangla J, Murdoch N, Martell JM (2009) Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene. Clin Orthop Relat Res 467(1):141–145PubMedCrossRef Garvin KL, Hartman CW, Mangla J, Murdoch N, Martell JM (2009) Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene. Clin Orthop Relat Res 467(1):141–145PubMedCrossRef
9.
Zurück zum Zitat Urban JA, Garvin KL, Boese CK, Bryson L, Pedersen DR, Callaghan JJ, Miller RK (2001) Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am 83(11):1688–1694PubMed Urban JA, Garvin KL, Boese CK, Bryson L, Pedersen DR, Callaghan JJ, Miller RK (2001) Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am 83(11):1688–1694PubMed
10.
Zurück zum Zitat Kress AM, Schmidt R, Holzwarth U, Forst R, Mueller LA (2011) Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-years follow-up. Int Orthop 35:195–200PubMedCrossRef Kress AM, Schmidt R, Holzwarth U, Forst R, Mueller LA (2011) Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-years follow-up. Int Orthop 35:195–200PubMedCrossRef
11.
Zurück zum Zitat Hamnouche D, Zaoui A, Zadegan F, Sedel L, Nizand R (2011) Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty. Int Orthop 35:207–213CrossRef Hamnouche D, Zaoui A, Zadegan F, Sedel L, Nizand R (2011) Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty. Int Orthop 35:207–213CrossRef
12.
Zurück zum Zitat Bascarevic Z, Vukasinovic Z, Slavkovic N, Dulic B, Trajkovic G, Bascarevic V, Timotijevic S (2010) Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearing in total arthroplasty: a comparative study. Int Orthop 34(8):1129–1135PubMedCrossRef Bascarevic Z, Vukasinovic Z, Slavkovic N, Dulic B, Trajkovic G, Bascarevic V, Timotijevic S (2010) Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearing in total arthroplasty: a comparative study. Int Orthop 34(8):1129–1135PubMedCrossRef
13.
Zurück zum Zitat Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS (2009) The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am 91(6):1344–1349PubMedCrossRef Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS (2009) The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am 91(6):1344–1349PubMedCrossRef
14.
Zurück zum Zitat Keurentjes JC, Kulpers RM, Wever DJ, Schreurs BW (2008) High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res 466(6):1438–1443PubMedCrossRef Keurentjes JC, Kulpers RM, Wever DJ, Schreurs BW (2008) High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res 466(6):1438–1443PubMedCrossRef
15.
Zurück zum Zitat Walter WL, Waters TS, Gillies M, Donohoo S, Kurtz SM, Ranawat AS, Hozack WJ, Tuke MA (2008) Squeaking hips. J Bone Joint Surg Am 90(suppl4):102–111PubMedCrossRef Walter WL, Waters TS, Gillies M, Donohoo S, Kurtz SM, Ranawat AS, Hozack WJ, Tuke MA (2008) Squeaking hips. J Bone Joint Surg Am 90(suppl4):102–111PubMedCrossRef
16.
Zurück zum Zitat Yoo JJ, Kim YM, Yoon KS, Koo KH, Song WS, Kim HJ (2005) Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study. J Bone Joint Surg Am 87(3):530–535PubMedCrossRef Yoo JJ, Kim YM, Yoon KS, Koo KH, Song WS, Kim HJ (2005) Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study. J Bone Joint Surg Am 87(3):530–535PubMedCrossRef
17.
Zurück zum Zitat Ficat RP (1985) Idiopathic bone necrosis of the femoral head. Early diagnosis and treatment. J Bone Joint Surg Br 67(1):3–9PubMed Ficat RP (1985) Idiopathic bone necrosis of the femoral head. Early diagnosis and treatment. J Bone Joint Surg Br 67(1):3–9PubMed
18.
Zurück zum Zitat Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51(4):737–755PubMed Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51(4):737–755PubMed
19.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Reumatol 15(12):1833–1840 Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Reumatol 15(12):1833–1840
20.
Zurück zum Zitat Zahiri CA, Schmalzried TP, Szuszczewicz ES, Amstutz HC (1998) Assessing activity in joint replacement patients. J Arthroplasty 13(8):890–895PubMedCrossRef Zahiri CA, Schmalzried TP, Szuszczewicz ES, Amstutz HC (1998) Assessing activity in joint replacement patients. J Arthroplasty 13(8):890–895PubMedCrossRef
21.
Zurück zum Zitat Dorr LD (1986) Total hip replacement using APR system. Tech Orthop 1:22–34CrossRef Dorr LD (1986) Total hip replacement using APR system. Tech Orthop 1:22–34CrossRef
22.
Zurück zum Zitat Kim Y-H, Kim VE (1993) Uncemented porous-coated anatomic total hip replacement. Results at six years in a consecutive series. J Bone Joint Surg Br 75(1):6–13PubMed Kim Y-H, Kim VE (1993) Uncemented porous-coated anatomic total hip replacement. Results at six years in a consecutive series. J Bone Joint Surg Br 75(1):6–13PubMed
23.
Zurück zum Zitat Kim Y-H, Kim J-S, Oh S-H, Kim J-M (2003) Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating. J Bone Joint Surg Am 85(9):1682–1688PubMed Kim Y-H, Kim J-S, Oh S-H, Kim J-M (2003) Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating. J Bone Joint Surg Am 85(9):1682–1688PubMed
24.
Zurück zum Zitat Kim Y-H, Kim J-S, Cho S-H (2001) A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomized study. J Bone Joint Surg Br 83(5):742–750PubMedCrossRef Kim Y-H, Kim J-S, Cho S-H (2001) A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomized study. J Bone Joint Surg Br 83(5):742–750PubMedCrossRef
25.
Zurück zum Zitat Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 64(7):970–982PubMed Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 64(7):970–982PubMed
26.
Zurück zum Zitat DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed
27.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed
28.
Zurück zum Zitat Kaplan EL, Meier P (1958) Nonparametric estimation from incomplete observation. J Am Stat Assoc 53:457–481CrossRef Kaplan EL, Meier P (1958) Nonparametric estimation from incomplete observation. J Am Stat Assoc 53:457–481CrossRef
29.
Zurück zum Zitat Hyder N, Nevelos AB, Barabas TG (1996) Cementless ceramic hip arthroplasties in patients less than 30 years old. J Arthroplasty 11(6):679–686PubMedCrossRef Hyder N, Nevelos AB, Barabas TG (1996) Cementless ceramic hip arthroplasties in patients less than 30 years old. J Arthroplasty 11(6):679–686PubMedCrossRef
30.
Zurück zum Zitat Bizot P, Banallec L, Sedel L, Nizard R (2000) Alumina-on-alumina total hip prostheses in patients 40 years of age or younger. Clin Orthop Relat Res 379:68–76PubMedCrossRef Bizot P, Banallec L, Sedel L, Nizard R (2000) Alumina-on-alumina total hip prostheses in patients 40 years of age or younger. Clin Orthop Relat Res 379:68–76PubMedCrossRef
31.
Zurück zum Zitat Garcia-Rey E, Cruz-Pardos A, Garcia-Cimbrelo E (2009) Alumina-on-alumina total hip arthroplasty in young patients: diagnosis is more important than age. Clin Orthop Relat Res 467(9):2281–2289PubMedCrossRef Garcia-Rey E, Cruz-Pardos A, Garcia-Cimbrelo E (2009) Alumina-on-alumina total hip arthroplasty in young patients: diagnosis is more important than age. Clin Orthop Relat Res 467(9):2281–2289PubMedCrossRef
32.
Zurück zum Zitat Yoon H-J, Yoo J-J, Yoon K-S, Koo K-H, Kim H-J (2012) Alumina-on-alumina THA performed in patients younger than 30 years: a 10-year minimum followup study. Clin Orthop Relat Res 470(12):3530–3536PubMedCrossRef Yoon H-J, Yoo J-J, Yoon K-S, Koo K-H, Kim H-J (2012) Alumina-on-alumina THA performed in patients younger than 30 years: a 10-year minimum followup study. Clin Orthop Relat Res 470(12):3530–3536PubMedCrossRef
33.
Zurück zum Zitat Bierbaum BE, Nairus J, Kuesis D, Morrison JC, Ward D (2002) Ceramic-on-ceramic bearings in total hip arthroplasty. Clin Orthop Relat Res 405:158–163PubMedCrossRef Bierbaum BE, Nairus J, Kuesis D, Morrison JC, Ward D (2002) Ceramic-on-ceramic bearings in total hip arthroplasty. Clin Orthop Relat Res 405:158–163PubMedCrossRef
34.
Zurück zum Zitat Kim Y-H, Park J-W, Kim J-S (2012) Cementless metaphyseal fitting anatomic total hip arthroplasty with a ceramic-on-ceramic bearing in patients thirty years of age or younger. J Bone Joint Surg Am 94(17):1570–1575PubMedCrossRef Kim Y-H, Park J-W, Kim J-S (2012) Cementless metaphyseal fitting anatomic total hip arthroplasty with a ceramic-on-ceramic bearing in patients thirty years of age or younger. J Bone Joint Surg Am 94(17):1570–1575PubMedCrossRef
35.
Zurück zum Zitat Engh CA Jr, Stepniewski AS, Ginn SD, Beykirch SE, Sychterz-Terefenko CJ, Hopper RH Jr, Engh CA (2006) A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked Marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty 21(6 suppl 2):17–25PubMedCrossRef Engh CA Jr, Stepniewski AS, Ginn SD, Beykirch SE, Sychterz-Terefenko CJ, Hopper RH Jr, Engh CA (2006) A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked Marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty 21(6 suppl 2):17–25PubMedCrossRef
36.
Zurück zum Zitat Bitsch RG, Loidolt T, Heisel C, Ball S, Schmalzried TP (2008) Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am 90(7):1487–1491PubMedCrossRef Bitsch RG, Loidolt T, Heisel C, Ball S, Schmalzried TP (2008) Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am 90(7):1487–1491PubMedCrossRef
37.
Zurück zum Zitat Bradford L, Baker D, Ries MD, Pruitt LA (2004) Fatigue crack propagation resistance of highly crosslinked polyethylene. Clin Orthop Relat Res 429:68–73PubMedCrossRef Bradford L, Baker D, Ries MD, Pruitt LA (2004) Fatigue crack propagation resistance of highly crosslinked polyethylene. Clin Orthop Relat Res 429:68–73PubMedCrossRef
38.
Zurück zum Zitat Endo M, Tipper JL, Barton DC, Stone MH, Ingham E, Fisher J (2002) Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proc Inst Mech Eng H 216(2):111–122PubMedCrossRef Endo M, Tipper JL, Barton DC, Stone MH, Ingham E, Fisher J (2002) Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proc Inst Mech Eng H 216(2):111–122PubMedCrossRef
39.
Zurück zum Zitat Fisher J, McEwen HM, Tipper JL, Galvin AL, Ingram J, Kamali A, Stone MH, Ingham E (2004) Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns. Clin Orthop Relat Res 428:114–119PubMedCrossRef Fisher J, McEwen HM, Tipper JL, Galvin AL, Ingram J, Kamali A, Stone MH, Ingham E (2004) Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns. Clin Orthop Relat Res 428:114–119PubMedCrossRef
40.
Zurück zum Zitat Thomas GE, Simpson DJ, Mehmood S, Taylor A, McLardy-Smith P, Gill HS, Murray DW, Glyn-Jones S (2011) The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg Am 93(8):716–722PubMedCrossRef Thomas GE, Simpson DJ, Mehmood S, Taylor A, McLardy-Smith P, Gill HS, Murray DW, Glyn-Jones S (2011) The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg Am 93(8):716–722PubMedCrossRef
41.
Zurück zum Zitat McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD (2009) Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Joint Surg Am 91(4):773–782PubMedCrossRef McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD (2009) Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Joint Surg Am 91(4):773–782PubMedCrossRef
Metadaten
Titel
A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty
verfasst von
Young-Hoo Kim
Jang-Won Park
Sourabh S. Kulkarni
Yoon-Hong Kim
Publikationsdatum
01.11.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 11/2013
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-2036-9

Weitere Artikel der Ausgabe 11/2013

International Orthopaedics 11/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.