Background

An accurate, early diagnosis and treatment of adenomatous polyp can curtail progression to colorectal cancer. F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG PET) reveals the biochemical changes associated with the development of many cancers which precede the appearance of gross anatomical changes that may be visualized during surgical resection or via imaging with MR or CT.

Intervention

We detail the history of a 64 year old female who had a whole-body FDG PET scan as a part of an employee wellness program. A dose of 12.2 mCi of F-18 labeled FDG was administered.

Results

A focal cecal uptake with a standardized uptake value (SUV) of 8.9 was found on the PET scan. Conversely, only normal mucosa was observed during a colonoscopy done 2 months after the PET scan. Motivated by the PET scan finding, the colonoscopist performed a biopsy which revealed a villous adenoma without high grade dysplasia. Pathology from tissue extracted during an exploratory laparatomy completed one month later found the lesion to be a villous adenoma with high grade dysplasia.

Conclusion

Whole-body FDG PET scan revealed the biochemical metabolic changes in malignancy that preceded the appearance of any gross anatomical abnormality. A positive FDG PET scan indicative of colorectal cancer should be followed up with a colonoscopy and biopsy even in a visibly normal mucosa.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1752-1947-1-99) contains supplementary material, which is available to authorized users.

Competing interests

The author(s) declare that they have no competing interests.

Authors' contributions

BR drafted the manuscript, BR and PS reviewed the literature,
RC did the colonoscopy; AB admitted the patient and followed up with the patient,
JM and MS were involved with imaging the patient; YD interpreted the pathology report.
All authors read and approved the final manuscript.

Background

We hereby report a case of advanced adenoma which was detected on a whole-body FDG PET scan despite the fact that the mucosa had a normal appearance on follow up colonoscopy. F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG PET) reveals the biochemical changes associated with the development of many cancers which precede the appearance of gross anatomical changes that may be visualized during surgical resection or via imaging with MR or CT.

Methods

A dose of 12.2 mCi was given to the patient following a 4 hour fasting period. The tracer incorporated for 1 hour prior to image acquisition. A 6 bed position, whole-body PET scan was performed on a Siemens HR+ PET scanner. Each bed position included a 2 minute transmission followed by a 5 minute emission scan. Reconstruction parameters were 2 iterations/8 subsets (OSEM) with a 4 mm smoothing Guassian filter

Case presentation

The patient is a 64 year old female who had a whole body FDG-PET scan in June 2004 as part of an employee wellness program. The scan was negative except for a focal abnormality in the cecal area which had an SUV of 8.9 (Figure 1). The patient was completely asymptomatic. A colonoscopy performed two years earlier was normal.
Two months after the FDG-PET scan, a colonoscopy was performed. There was no visible abnormality in the cecum (Figure 2) but prompted by the positive PET scan, a biopsy was obtained. During the biopsy, the gastroenterologist noted abnormal tissue consistency and suspected a blanket of polyps. Multiple biopsies were obtained although no gross abnormality was visible. The pathology results showed a villotubular adenoma without high grade dysplasia. An exploratory laparatomy was performed one month after the colonoscopy to remove the tissue with abnormal histology. Gross pathology showed an exophytic polypoid lesion in the cecal pouch, adjacent to the ileocecal valve. The lesion measured 4.5 × 3 × 0.5 cm. Microscopic examination revealed villous adenoma with focal high grade dysplasia, negative for invasive carcinoma (Figure 3). Surgical margins and lymph nodes were free from dysplasia. A subsequent whole-body FDG PET/CT scan performed 10 months postoperatively was found to be normal.

Discussion

Polyp is a small growth of tissue shaped like the head or stalk of a mushroom. They are classified histologically as neoplastic (adenomatous) or non neoplastic [1]. Adenomas are traditionally divided into three types: tubular, tubulovillous, and villous. Advanced adenoma is defined by a national polyp study as being >= 1 cm in diameter or containing appreciable villous tissue or high grade dysplasia [2]. Our patient had a villous adenoma with high grade dysplasia. Once diagnosed, advanced adenomas should be resected to prevent progression to cancer and thus early diagnosis is critical.
In this educational case report, the patient had a high grade villous adenoma which was discovered due to its increased FDG uptake on a whole-body PET scan but the mucosa looked normal on the colonoscopy. FDG PET scanning detects biochemical changes which precede gross morphological changes in cancerous tissue. Increased cell surface glucose transporter protein 1 to 5 and increased level of hexokinase pathway explain the high FDG uptake in malignancy.
Narrow Band imaging and Chromoendoscopy with indigo carmine can increase the yield of conventional colonoscopy. [3, 4] The reasons cancers may be missed on colonoscopy are attributed to incomplete colonoscopy, poor bowel preparation, misinterpretation of what was seen (mostly flat polyps), failure to carry out adequate biopsy of lesions, and system failures related to follow up investigations in patients who had incomplete colonoscopy [58]. However, these conditions are not applicable for this case in which the mucosa was visibly normal on colonoscopy. The gastroenterologist has 25 years of experience in Endoscopy. Two other endoscopists were shown the pictures; they both said they would have assumed a false positive scan and wouldn't have done a biopsy of the area.
According to the current guidelines [9], since a colonoscopy had been performed on this patient two years prior to the PET scan, another colonoscopy would not have been repeated for another eight years. A whole-body FDG PET scan enabled the early diagnosis and removal of the advanced adenoma preventing its progression to invasive cancer in this patient.
FDG PET has a high sensitivity in diagnosing premalignant and advanced colonic neoplasia [1014]. Van Kouwen et al showed in a large prospective study that the sensitivity increases with size and grade of dysplasia [11]. An interesting experimental study showed induced colonic adenomas and carcinomas may be detected in apparently normal mucosa [15].

Conclusion

Whole-body FDG PET scan revealed the biochemical metabolic changes in malignancy that preceded the appearance of any gross anatomical abnormality. A positive FDG PET scan with a focal uptake in colon should be considered a significant finding indicative of colorectal cancer and follow up colonoscopy and biopsy should be recommended even in a visibly normal mucosa.

Acknowledgements

We would like to acknowledge the faculty and staff of Nuclear Medicine department who were involved in the care of the patient. A written consent was obtained from the patient.
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

The author(s) declare that they have no competing interests.

Authors' contributions

BR drafted the manuscript, BR and PS reviewed the literature,
RC did the colonoscopy; AB admitted the patient and followed up with the patient,
JM and MS were involved with imaging the patient; YD interpreted the pathology report.
All authors read and approved the final manuscript.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Allgemeinmedizin

Kombi-Abonnement

Mit e.Med Allgemeinmedizin erhalten Sie Zugang zu allen CME-Fortbildungen und Premium-Inhalten der allgemeinmedizinischen Zeitschriften, inklusive einer gedruckten Allgemeinmedizin-Zeitschrift Ihrer Wahl.

Anhänge

Authors’ original submitted files for images

Literatur
1.
Zurück zum Zitat Thoeni RF: Colorectal Cancer. Radiologic Staging. Radiol Clin North Am. 1997, 35 (2): 457-485.PubMed Thoeni RF: Colorectal Cancer. Radiologic Staging. Radiol Clin North Am. 1997, 35 (2): 457-485.PubMed
2.
Zurück zum Zitat Bond JH: Polyp Guideline: diagnosis, treatment and surveillance for patients with Colorectal polyps Practice Parameters. Committee of the American College of Gastroenterol. 2000, 95 (11): 3053-63. 10.1111/j.1572-0241.2000.03434.x.CrossRef Bond JH: Polyp Guideline: diagnosis, treatment and surveillance for patients with Colorectal polyps Practice Parameters. Committee of the American College of Gastroenterol. 2000, 95 (11): 3053-63. 10.1111/j.1572-0241.2000.03434.x.CrossRef
3.
Zurück zum Zitat Ince AT, Bolukbas C, Peker O, Bolukbas F, Ovunc O: Pit pattern type analyses of colon polyps with high-resolution colonoscope. Hepatogastroenterology. 2007, 54 (73): 67-70.PubMed Ince AT, Bolukbas C, Peker O, Bolukbas F, Ovunc O: Pit pattern type analyses of colon polyps with high-resolution colonoscope. Hepatogastroenterology. 2007, 54 (73): 67-70.PubMed
4.
Zurück zum Zitat Su MY, Hsu CM, Ho YP, Chen PC, Lin CJ, Chiu CT: Comparative study of conventional colonoscopy, chromoendoscopy, and narrow-band imaging systems in differential diagnosis of neoplastic and nonneoplastic colonic polyps. Am J Gastroenterol. 2006, 101 (12): 2711-16. 10.1111/j.1572-0241.2006.00932.x.CrossRefPubMed Su MY, Hsu CM, Ho YP, Chen PC, Lin CJ, Chiu CT: Comparative study of conventional colonoscopy, chromoendoscopy, and narrow-band imaging systems in differential diagnosis of neoplastic and nonneoplastic colonic polyps. Am J Gastroenterol. 2006, 101 (12): 2711-16. 10.1111/j.1572-0241.2006.00932.x.CrossRefPubMed
5.
Zurück zum Zitat Leaper M, Johnston MJ, Barclay M, Dobbis BR, Frizelle FA: Reasons for failure to Diagnose colorectal carcinoma at colonoscopy. Endoscopy. 2004, 36 (6): 499-503. 10.1055/s-2004-814399.CrossRefPubMed Leaper M, Johnston MJ, Barclay M, Dobbis BR, Frizelle FA: Reasons for failure to Diagnose colorectal carcinoma at colonoscopy. Endoscopy. 2004, 36 (6): 499-503. 10.1055/s-2004-814399.CrossRefPubMed
6.
Zurück zum Zitat Haseman JH, Lemmel GT, Rahmani EY, Rex DK: Failure of colonoscopy to detect Colorectal carcinoma: evaluation of 47 cases in 20 hospitals. Gastrointestinal Endosc. 1997, 45 (6): 451-5. 10.1016/S0016-5107(97)70172-X.CrossRef Haseman JH, Lemmel GT, Rahmani EY, Rex DK: Failure of colonoscopy to detect Colorectal carcinoma: evaluation of 47 cases in 20 hospitals. Gastrointestinal Endosc. 1997, 45 (6): 451-5. 10.1016/S0016-5107(97)70172-X.CrossRef
7.
Zurück zum Zitat Rex DK, Cultler CS, Lemmel GT, Rahmani EY, Clark DW, Helper DJ, Lehman GA, Mark DG: Colonoscopic miss rates of adenomas Determined by back to back colonoscopies. Gastroenterology. 1997, 112: 24-28. 10.1016/S0016-5085(97)70214-2.CrossRefPubMed Rex DK, Cultler CS, Lemmel GT, Rahmani EY, Clark DW, Helper DJ, Lehman GA, Mark DG: Colonoscopic miss rates of adenomas Determined by back to back colonoscopies. Gastroenterology. 1997, 112: 24-28. 10.1016/S0016-5085(97)70214-2.CrossRefPubMed
8.
Zurück zum Zitat Hosokawa O, Shirasaki S, Kaizaki Y, Hayashi H, Douden K, Hattori M: Invasive colorectal cancer detected unto 3 Years after colonoscopy negative for cancer. Endoscopy. 2003, 35 (6): 506-10. 10.1055/s-2003-39665.CrossRefPubMed Hosokawa O, Shirasaki S, Kaizaki Y, Hayashi H, Douden K, Hattori M: Invasive colorectal cancer detected unto 3 Years after colonoscopy negative for cancer. Endoscopy. 2003, 35 (6): 506-10. 10.1055/s-2003-39665.CrossRefPubMed
9.
Zurück zum Zitat Houston TP, Elster AB, Davis RM, Deitchman SD: The U.S. Preventive Services Task Force Guide to Clinical Preventive Services, second edition. AMA Council on Scientific Affairs. Am J Prev Med. 1998, 14 (4): 374-6. 10.1016/S0749-3797(97)00066-4.CrossRefPubMed Houston TP, Elster AB, Davis RM, Deitchman SD: The U.S. Preventive Services Task Force Guide to Clinical Preventive Services, second edition. AMA Council on Scientific Affairs. Am J Prev Med. 1998, 14 (4): 374-6. 10.1016/S0749-3797(97)00066-4.CrossRefPubMed
10.
Zurück zum Zitat Gutman F, Alberini JL, Wartski M, Vilain D, Le Stanc E, Sarandi F, Corone C, Tainturier C, Pecking AP: Incidental colonic focal lesions detected by FDG PET/CT. AJR Am J Roentgenol. 2005, 185 (2): 495-500.CrossRefPubMed Gutman F, Alberini JL, Wartski M, Vilain D, Le Stanc E, Sarandi F, Corone C, Tainturier C, Pecking AP: Incidental colonic focal lesions detected by FDG PET/CT. AJR Am J Roentgenol. 2005, 185 (2): 495-500.CrossRefPubMed
11.
Zurück zum Zitat Van Kouwen MC, Nagengast FM, Jansen JB, Oyen WJ, Drenth JP: 2-(18F)-fluoro-2-deoxy-D-glucose Positron emission tomography detects clinical relevant adenomas of the colon: A prospective study. J Clin Oncol. 2005, 23 (16): 3713-7. 10.1200/JCO.2005.02.401.CrossRefPubMed Van Kouwen MC, Nagengast FM, Jansen JB, Oyen WJ, Drenth JP: 2-(18F)-fluoro-2-deoxy-D-glucose Positron emission tomography detects clinical relevant adenomas of the colon: A prospective study. J Clin Oncol. 2005, 23 (16): 3713-7. 10.1200/JCO.2005.02.401.CrossRefPubMed
12.
Zurück zum Zitat Tatlidil R, Jadvar H, Bading JR, Conti PS: Incidental colonic fluorodeoxyglucose Uptake: correlation with Colonoscopic and histopathologic findings. Radiology. 2002, 224 (3): 783-7. 10.1148/radiol.2243011214.CrossRefPubMed Tatlidil R, Jadvar H, Bading JR, Conti PS: Incidental colonic fluorodeoxyglucose Uptake: correlation with Colonoscopic and histopathologic findings. Radiology. 2002, 224 (3): 783-7. 10.1148/radiol.2243011214.CrossRefPubMed
13.
Zurück zum Zitat Drenth JP, Nagengast FM, Oyen WJ: Evaluation of (pre-) malignant colonic Abnormalities: endoscopic validation of FDG-PET findings. Eur J Nucl Med. 2001, 28 (12): 1766-9. 10.1007/s002590100645.CrossRefPubMed Drenth JP, Nagengast FM, Oyen WJ: Evaluation of (pre-) malignant colonic Abnormalities: endoscopic validation of FDG-PET findings. Eur J Nucl Med. 2001, 28 (12): 1766-9. 10.1007/s002590100645.CrossRefPubMed
14.
Zurück zum Zitat Arslan N, Dehdashti F, Siegel BA: FDG uptake in colonic villous adenomas. Ann Nucl Med. 2005, 19 (4): 331-4.CrossRefPubMed Arslan N, Dehdashti F, Siegel BA: FDG uptake in colonic villous adenomas. Ann Nucl Med. 2005, 19 (4): 331-4.CrossRefPubMed
15.
Zurück zum Zitat Rubio CA, Jaramillo E, Sethyle J: Adenomas and carcinomas may be histologically Detected in apparently normal colonic mucosa. A study of carcinogen treated rats. In Vivo. 2001, 15 (4): 299-301.PubMed Rubio CA, Jaramillo E, Sethyle J: Adenomas and carcinomas may be histologically Detected in apparently normal colonic mucosa. A study of carcinogen treated rats. In Vivo. 2001, 15 (4): 299-301.PubMed
Metadaten
Titel
Advanced adenoma diagnosis with FDG PET in a visibly normal mucosa: a case report
verfasst von
Bhavya Rehani
Richard M. Chasen
Yvonne Dowdy
Ankur Bharija
Martin Satter
Pamela Strohmeyer
Joseph Mantil
Publikationsdatum
01.12.2007
Verlag
BioMed Central
Erschienen in
Journal of Medical Case Reports / Ausgabe 1/2007
Elektronische ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-1-99

Weitere Artikel der Ausgabe 1/2007

Journal of Medical Case Reports 1/2007 Zur Ausgabe