Skip to main content
Erschienen in: Journal of Children's Orthopaedics 6/2013

01.12.2013 | Original Clinical Article

Airport metal detector activation is rare after posterior spinal fusion in children with scoliosis

verfasst von: Peter D. Fabricant, Alex Robles, John S. Blanco

Erschienen in: Journal of Children's Orthopaedics | Ausgabe 6/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Since the September 11, 2001 terrorist attacks on the World Trade Center in New York City, travel security has become an ever-increasing priority in the United States. Frequent parent and patient inquiry and recent literature reports have generated interest in the impact of heightened security measures on patients with orthopaedic implants, and have indicated increasing rates of metal detector triggering. There are no reports to date, however, evaluating children and adolescents who have undergone posterior spinal fusion for scoliosis, so responses to patient and parent inquiries are not data-driven. The purpose of this study is to determine the frequency of airport metal detector triggering by patients who have had posterior-only spinal fusion and to characterise any potential predictors of metal detector activation.

Methods

A cross-sectional study was performed by interviewing 90 patients who underwent posterior-only spinal fusion for a diagnosis of juvenile or adolescent idiopathic scoliosis and have travelled by air in the past year. Demographic, clinical and surgical instrumentation data were collected and evaluated, along with patients’ reports of airport metal detector triggering and subsequent screening procedures.

Results

Five patients with stainless steel instrumentation (5.6 % of the cohort) triggered an airport walkthrough metal detector, and an additional five patients who did not trigger an airport detector triggered a handheld detector at a different venue. All patients who triggered an airport metal detector had stainless steel instrumentation implanted prior to 2008, and no patient with titanium instrumentation triggered any detector in any venue. All trigger events required subsequent screening procedures, even when an implant card was presented.

Conclusions

In this cohort of children and adolescents with posterior spinal instrumentation, airport walkthrough metal detector triggering was a rare event. Therefore, we advise patients and families with planned posterior scoliosis fusions using titanium instrumentation that airport detection risk is essentially non-existent, and only rare for those with planned stainless steel instrumentation. We no longer issue implant cards postoperatively, as these did not prevent further screening procedures in this cohort.

Level of evidence

Prognostic level 2. Study design: cross-sectional.
Literatur
1.
Zurück zum Zitat Basu P, Packer GJ, Himstedt J (1997) Detection of orthopaedic implants by airport metal detectors. J Bone Joint Surg Br 79:388–389PubMedCrossRef Basu P, Packer GJ, Himstedt J (1997) Detection of orthopaedic implants by airport metal detectors. J Bone Joint Surg Br 79:388–389PubMedCrossRef
2.
Zurück zum Zitat Grohs JG, Gottsauner-Wolf F (1997) Detection of orthopaedic prostheses at airport security checks. J Bone Joint Surg Br 79:385–387PubMedCrossRef Grohs JG, Gottsauner-Wolf F (1997) Detection of orthopaedic prostheses at airport security checks. J Bone Joint Surg Br 79:385–387PubMedCrossRef
3.
Zurück zum Zitat van Rhijn LW, Veraart BE (1994) Metal detectors for security checks mostly insensitive for metal implants. Ned Tijdschr Geneeskd 138:825–827PubMed van Rhijn LW, Veraart BE (1994) Metal detectors for security checks mostly insensitive for metal implants. Ned Tijdschr Geneeskd 138:825–827PubMed
6.
Zurück zum Zitat Johnson AJ, Naziri Q, Hooper HA, Mont MA (2012) Detection of total hip prostheses at airport security checkpoints: how has heightened security affected patients? J Bone Joint Surg Am 94:e44. doi:10.2106/JBJS.K.00864PubMed Johnson AJ, Naziri Q, Hooper HA, Mont MA (2012) Detection of total hip prostheses at airport security checkpoints: how has heightened security affected patients? J Bone Joint Surg Am 94:e44. doi:10.​2106/​JBJS.​K.​00864PubMed
9.
Zurück zum Zitat Ramirez MA, Rodriguez EK, Zurakowski D, Richardson LC (2007) Detection of orthopaedic implants in vivo by enhanced-sensitivity, walk-through metal detectors. J Bone Joint Surg Am 89:742–746. doi:10.2106/JBJS.F.00570PubMedCrossRef Ramirez MA, Rodriguez EK, Zurakowski D, Richardson LC (2007) Detection of orthopaedic implants in vivo by enhanced-sensitivity, walk-through metal detectors. J Bone Joint Surg Am 89:742–746. doi:10.​2106/​JBJS.​F.​00570PubMedCrossRef
10.
Zurück zum Zitat Kamineni S, Legge S, Ware H (2002) Metallic orthopaedic implants and airport metal detectors. J Arthroplasty 17:62–65PubMedCrossRef Kamineni S, Legge S, Ware H (2002) Metallic orthopaedic implants and airport metal detectors. J Arthroplasty 17:62–65PubMedCrossRef
11.
Zurück zum Zitat Kocher MS, Zurakowski D (2004) Clinical epidemiology and biostatistics: a primer for orthopaedic surgeons. J Bone Joint Surg Am 86-A:607–620PubMed Kocher MS, Zurakowski D (2004) Clinical epidemiology and biostatistics: a primer for orthopaedic surgeons. J Bone Joint Surg Am 86-A:607–620PubMed
12.
Zurück zum Zitat Emsley J (2001) Titanium. In: Nature’s building blocks: an A–Z guide to the elements. Oxford University Press, Oxford, p 452 Emsley J (2001) Titanium. In: Nature’s building blocks: an A–Z guide to the elements. Oxford University Press, Oxford, p 452
13.
Zurück zum Zitat Transportation Security Administration (TSA) (2012) Notification Card 2012 Transportation Security Administration (TSA) (2012) Notification Card 2012
14.
Zurück zum Zitat Transportation Security Administration (TSA) (2012) Advanced Imaging Technology (AIT) 2012 Transportation Security Administration (TSA) (2012) Advanced Imaging Technology (AIT) 2012
Metadaten
Titel
Airport metal detector activation is rare after posterior spinal fusion in children with scoliosis
verfasst von
Peter D. Fabricant
Alex Robles
John S. Blanco
Publikationsdatum
01.12.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Journal of Children's Orthopaedics / Ausgabe 6/2013
Print ISSN: 1863-2521
Elektronische ISSN: 1863-2548
DOI
https://doi.org/10.1007/s11832-013-0527-2

Weitere Artikel der Ausgabe 6/2013

Journal of Children's Orthopaedics 6/2013 Zur Ausgabe

Current Concept Review

Longitudinal epiphyseal bracket

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.