Skip to main content

Annals of Nuclear Medicine

Ausgabe 1/2001

Inhalt (14 Artikel)

Original Articles

Lymphoscintigraphy of melanoma: Lymphatic channel activity guides localization of sentinel lymph nodes, and gamma camera imaging/counting confirms presence of radiotracer in excised nodes

Wei-Jen Shih, David A. Sloan, Michael T. Hackett, U Yun Ryo, Becky Weizbinski, John J. Coupal, Sylvia Magoun

Original Articles

Relationship between thallium-201 myocardial SPECT and findings of endomyocardial biopsy specimens in dilated cardiomyopathy

Motohiro Watanabe, Kohshi Gotoh, Kenshi Nagashima, Yoshihiro Uno, Toshiyuki Noda, Kazuhiko Nishigaki, Genzou Takemura, Motoo Kanoh, Norio Yasuda, Yasushi Ohno, Shinya Minatoguchi, Hisayoshi Fujiwara

Original Articles

Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source on thallium-201 myocardial SPECT

Yoichi Ohyama, Seiji Tomiguchi, Tomohiro Kira, Mitsuko Kira, Akinori Tsuji, Akihiro Kojima, Masanori Matsumoto, Mutsumasa Takahashi, Yoshito Inobe, Hirofumi Yasue

Original Articles

A simple objective parameter for perfusion study of renal transplant

Kiyoshi Koizumi, Hideo Kakiuchi, Toru Sacuchi, Shingo Inoue, Shuichiro Fuse, Etsuko Kawakami, Akira Yamazaki, Koichi Kozaki, Takeshi Nagao

Original Articles

Comparison of99mTc-tetrofosmin uptakes on planar images with those in excised rats organs with those in excised rats organs

Masahisa Onoguchi, Teruhiko Takayama, Norihisa Tonami, Shinsuke Kyogoku, Yutaka Naoi, Masahiro Irimoto, Tadayuki Maehara

Case Reports

The role of technetium-99m-HMPAO-labeled WBC scintigraphy in the diagnosis of orbital cellulitis

Elvan Sayit, Meltem Söylev, Gamze Çapa, Ismet Durak, Emel Ada, Mustafa Yilmaz, Hatice Durak

Case Reports

Superiority of Tc-99m MAG3 to Tc-99m DTPA in treating a patient with mild renal artery stenosis

Pinar Özgen Kiratli, Biray Caner, Bülent Altun, Saruhan Çekirge

Case Reports

Interesting RI accumulation in hepatic images with Tc-99m GSA SPECT scintigraphy in idiopathic portal hypertension

Takuro Nishida, Katsumi Hayakawa, Hiroyuki Ogasawara, Yoshinori Katsuma

Case Reports

Unusual early bile excretion from the liver in patients with fulminant hepatic failure as detected by Tc-99m-PMT hepatobiliary scintigraphy; Comparison with Tc-99m-GSA scintigraphy

Shin Matsuoka, Katsuhiro Uchiyama, Yoshio Kuniyasu, Yasuo Niio, Shin Hasebe, Hideki Shima, Sonomi Oishi, Youko Nojiri, Hitoshi Ogata

Short Communications

Validation of CBF measurement with non-invasive microsphere method (NIMS) compared with autoradiography method (ARG)

Tatsuro Kaminaga, Natsuko Kunimatsu, Takashi Chikamatsu, Shigeru Furui

Short Communications

Clinical significance of reverse redistribution on resting thallium-301 imaging in patients with vasospastic angina

Akira Narang, Jong-Dae Lee, Hiromasa Shimiru, Aklyoshi Tsubokawa, Hiroyasu Uzui, Tatsuro Tsuchida, Norio Takahashi, Yoshiharu Yonekura, Takanori Ueda

Short Communications

Evaluation of resting brain conditions measured by two different methods (i.v. and oral administration) with18F-FDG-PET

Mehedi Masud, Kellehiro Yamaguchi, Hisashi Rikimaru, Manabu Tashiro, Kaoru Ozaki, Shoichi Watanuki, Masayasu Miyake, Tatsuo Ido, Masatoshi Itoh

Technical Notes

Performance assessment of O-18 water purifier

Haruhiro Kitano, Yasuhiro Magata, Akira Tanaka, Takahiro Mukai, Yuji Kuge, Kotaro Nagatsu, Junji Konishi, Hideo Saji

Technical Notes

Comparison of image reconstruction algorithms in myocardial perfusion scintigraphy

Jingming Bai, Jun Hashimoto, Takayuki Suzuki, Tadaki Nakahara, Atsushi Kubo, Shiro Iwanaga, Hideo Mitamura, Satoshi Ogawa