Skip to main content
Erschienen in: European Spine Journal 5/2008

01.05.2008 | Original Article

Application of full-scale three-dimensional models in patients with rheumatoid cervical spine

verfasst von: Jun Mizutani, Takeshi Matsubara, Muneyoshi Fukuoka, Nobuhiko Tanaka, Hirotaka Iguchi, Aiharu Furuya, Hideki Okamoto, Ikuo Wada, Takanobu Otsuka

Erschienen in: European Spine Journal | Ausgabe 5/2008

Einloggen, um Zugang zu erhalten

Abstract

Full-scale three-dimensional (3D) models offer a useful tool in preoperative planning, allowing full-scale stereoscopic recognition from any direction and distance with tactile feedback. Although skills and implants have progressed with various innovations, rheumatoid cervical spine surgery remains challenging. No previous studies have documented the usefulness of full-scale 3D models in this complicated situation. The present study assessed the utility of full-scale 3D models in rheumatoid cervical spine surgery. Polyurethane or plaster 3D models of 15 full-sized occipitocervical or upper cervical spines were fabricated using rapid prototyping (stereolithography) techniques from 1-mm slices of individual CT data. A comfortable alignment for patients was reproduced from CT data obtained with the patient in a comfortable occipitocervical position. Usefulness of these models was analyzed. Using models as a template, appropriate shape of the plate-rod construct could be created in advance. No troublesome Halo-vests were needed for preoperative adjustment of occipitocervical angle. No patients complained of dysphasia following surgery. Screw entry points and trajectories were simultaneously determined with full-scale dimensions and perspective, proving particularly valuable in cases involving high-riding vertebral artery. Full-scale stereoscopic recognition has never been achieved with any existing imaging modalities. Full-scale 3D models thus appear useful and applicable to all complicated spinal surgeries. The combination of computer-assisted navigation systems and full-scale 3D models appears likely to provide much better surgical results.
Literatur
1.
Zurück zum Zitat Abumi K, Takada K, Shono Y, Kaneda K, Fujiya M (1999) Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems. Spine 24:1425–1434PubMedCrossRef Abumi K, Takada K, Shono Y, Kaneda K, Fujiya M (1999) Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems. Spine 24:1425–1434PubMedCrossRef
2.
Zurück zum Zitat Abumi K, Kaneda K, Shono Y, Fujiya M (1999) One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg 90:19–26PubMed Abumi K, Kaneda K, Shono Y, Fujiya M (1999) One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg 90:19–26PubMed
3.
Zurück zum Zitat Brown GA, Milner B, Firoozbakhsh K (2002) Application of computer-generated stereolithography and interpositioning template in acetabular fractures: a report of eight cases. J Orthop Trauma 16:347–352PubMedCrossRef Brown GA, Milner B, Firoozbakhsh K (2002) Application of computer-generated stereolithography and interpositioning template in acetabular fractures: a report of eight cases. J Orthop Trauma 16:347–352PubMedCrossRef
4.
Zurück zum Zitat Brown GA, Firoozbakhsh K, DeCoster TA, Reyna JR, Moneim M (2003) Rapid prototyping: the future of trauma surgery? J Bone Joint Surg Am 85A(Suppl 4):49–55 Brown GA, Firoozbakhsh K, DeCoster TA, Reyna JR, Moneim M (2003) Rapid prototyping: the future of trauma surgery? J Bone Joint Surg Am 85A(Suppl 4):49–55
5.
Zurück zum Zitat Chen JF, Wu CT, Lee SC, Lee ST (2005) Posterior atlantoaxial transpedicular screw and plate fixation. J Neurosurg Spine 2:386–392PubMed Chen JF, Wu CT, Lee SC, Lee ST (2005) Posterior atlantoaxial transpedicular screw and plate fixation. J Neurosurg Spine 2:386–392PubMed
6.
Zurück zum Zitat van Dick M, Smit TH, Jiya TU, Wuisman PI (2001) Polyurethane real-size models used in planning complex spinal surgery. Spine 26:1920–1926CrossRef van Dick M, Smit TH, Jiya TU, Wuisman PI (2001) Polyurethane real-size models used in planning complex spinal surgery. Spine 26:1920–1926CrossRef
7.
Zurück zum Zitat D’Urso PS, Askin G, Earwaker JS, Merry GS, Thompson RG, Baker TM et.al (1999) Spinal biomodeling. Spine 24:1247–1251PubMedCrossRef D’Urso PS, Askin G, Earwaker JS, Merry GS, Thompson RG, Baker TM et.al (1999) Spinal biomodeling. Spine 24:1247–1251PubMedCrossRef
8.
Zurück zum Zitat Ebraheim NA, Lu J, Biyani A, Brown JA, Yeasting RA (1996) An anatomic study of the thickness of the occipital bone. Implications for occipitocervical instrumentation. Spine 21:1725–1729PubMedCrossRef Ebraheim NA, Lu J, Biyani A, Brown JA, Yeasting RA (1996) An anatomic study of the thickness of the occipital bone. Implications for occipitocervical instrumentation. Spine 21:1725–1729PubMedCrossRef
9.
Zurück zum Zitat Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw, rod fixation. Spine 26:2467–2471PubMedCrossRef Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw, rod fixation. Spine 26:2467–2471PubMedCrossRef
10.
Zurück zum Zitat Magerl F, Seemann PS, Gallen S (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine 1. Springer, New York, pp 322–327 Magerl F, Seemann PS, Gallen S (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine 1. Springer, New York, pp 322–327
11.
Zurück zum Zitat Matsubara T, Mizutani J, Fukuoka M, Hatoh T, Kojima H, Otsuka T (2007) Safe atlantoaxial fixation using a laminar screw (intralaminar screw) in a patient with unilateral occlusion of vertebral artery. Spine 32:E30–E33PubMedCrossRef Matsubara T, Mizutani J, Fukuoka M, Hatoh T, Kojima H, Otsuka T (2007) Safe atlantoaxial fixation using a laminar screw (intralaminar screw) in a patient with unilateral occlusion of vertebral artery. Spine 32:E30–E33PubMedCrossRef
12.
Zurück zum Zitat Morishita N, Ohota K, Miura Y (2005) The influences of Halo-Vest fixation and cervical hyperextension on swallowing in healthy volunteers. Spine 30:E179–E182CrossRef Morishita N, Ohota K, Miura Y (2005) The influences of Halo-Vest fixation and cervical hyperextension on swallowing in healthy volunteers. Spine 30:E179–E182CrossRef
13.
Zurück zum Zitat Garfin SR, Botte MJ, Waters RL (1986) Complication in the use of the halo fixation device. J Bone Joint Surg 68-A:320–325 Garfin SR, Botte MJ, Waters RL (1986) Complication in the use of the halo fixation device. J Bone Joint Surg 68-A:320–325
14.
Zurück zum Zitat Mizutani J, Tsubouchi S, Fukuoka M, Otsuka T, Matsui N (2002) Surgical treatment of the rheumatoid cervical spine in patients aged 70 years or older. Rheumatology 41:910–916PubMedCrossRef Mizutani J, Tsubouchi S, Fukuoka M, Otsuka T, Matsui N (2002) Surgical treatment of the rheumatoid cervical spine in patients aged 70 years or older. Rheumatology 41:910–916PubMedCrossRef
15.
Zurück zum Zitat Mizutani J, Tsubouchi S, Fukuoka M, Otsuka T, Matsui N (2002) Syringomyelia caused by loosening of multistrand cables following C1–2 Brooks-type fusion in the rheumatoid cervical spine. J Neurosurg 97(Suppl 3):366–368PubMed Mizutani J, Tsubouchi S, Fukuoka M, Otsuka T, Matsui N (2002) Syringomyelia caused by loosening of multistrand cables following C1–2 Brooks-type fusion in the rheumatoid cervical spine. J Neurosurg 97(Suppl 3):366–368PubMed
16.
Zurück zum Zitat Nadim Y, Lu J, Sabry FF, Ebraheim N (2000) Occipital screws in occipitocervical fusion, their relation to the venous sinuses: an anatomic and radiographic study. Orthopedics 23:717–719PubMed Nadim Y, Lu J, Sabry FF, Ebraheim N (2000) Occipital screws in occipitocervical fusion, their relation to the venous sinuses: an anatomic and radiographic study. Orthopedics 23:717–719PubMed
17.
Zurück zum Zitat Nicholas JM, Andrew MC, Noel GS (1990) The display of three-dimensional anatomy with stereolithographic models. J Digit Imaging 3:200–203CrossRef Nicholas JM, Andrew MC, Noel GS (1990) The display of three-dimensional anatomy with stereolithographic models. J Digit Imaging 3:200–203CrossRef
18.
Zurück zum Zitat Onishi K, Maruyama Y (2001) Three-dimensional solid model integrated with dental model for maxillofacial surgery. Plast Reconstr Surg 108:1696–1699PubMedCrossRef Onishi K, Maruyama Y (2001) Three-dimensional solid model integrated with dental model for maxillofacial surgery. Plast Reconstr Surg 108:1696–1699PubMedCrossRef
19.
Zurück zum Zitat Ono I, Abe K, Shiotani S, Hirayama K (2000) Producing a full-scale model from computed tomographic data with the rapid prototyping technique using the binder jet method: a comparison with the laser lithography method using a dry skull. J Craniofac Surg 11:527–537PubMedCrossRef Ono I, Abe K, Shiotani S, Hirayama K (2000) Producing a full-scale model from computed tomographic data with the rapid prototyping technique using the binder jet method: a comparison with the laser lithography method using a dry skull. J Craniofac Surg 11:527–537PubMedCrossRef
20.
Zurück zum Zitat Seichi A, Takeshita K, Nakajima S, Akune T, Kawaguchi H, Nakamura K (2005) Revision cervical spine surgery using transarticular or pedicle screws under a computer-assisted image-guidance system. J Orthop Sci 10:385–390PubMedCrossRef Seichi A, Takeshita K, Nakajima S, Akune T, Kawaguchi H, Nakamura K (2005) Revision cervical spine surgery using transarticular or pedicle screws under a computer-assisted image-guidance system. J Orthop Sci 10:385–390PubMedCrossRef
21.
Zurück zum Zitat Stoker NG, Mankovich NJ, Valentino D (1992) Stereolithographic models for surgical planning: preliminary report. J Oral Maxillofac Surg 50:466–471PubMedCrossRef Stoker NG, Mankovich NJ, Valentino D (1992) Stereolithographic models for surgical planning: preliminary report. J Oral Maxillofac Surg 50:466–471PubMedCrossRef
22.
Zurück zum Zitat Tan M, Wang H, Wang Y, Zhang G, Yi P, Li Z et al (2003) Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine 28:888–895PubMedCrossRef Tan M, Wang H, Wang Y, Zhang G, Yi P, Li Z et al (2003) Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine 28:888–895PubMedCrossRef
23.
Zurück zum Zitat Wagner JD, Baack B, Brown GA, Kelly J (2004) Rapid 3-dimensional prototyping for surgical repair of maxillofacial fractures: a technical note. J Oral Maxillofac Surg 62:898–901PubMedCrossRef Wagner JD, Baack B, Brown GA, Kelly J (2004) Rapid 3-dimensional prototyping for surgical repair of maxillofacial fractures: a technical note. J Oral Maxillofac Surg 62:898–901PubMedCrossRef
24.
Zurück zum Zitat Winder J, Bibb R (2005) Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery. J Oral Maxillofac Surg 63:1006–1015PubMedCrossRef Winder J, Bibb R (2005) Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery. J Oral Maxillofac Surg 63:1006–1015PubMedCrossRef
Metadaten
Titel
Application of full-scale three-dimensional models in patients with rheumatoid cervical spine
verfasst von
Jun Mizutani
Takeshi Matsubara
Muneyoshi Fukuoka
Nobuhiko Tanaka
Hirotaka Iguchi
Aiharu Furuya
Hideki Okamoto
Ikuo Wada
Takanobu Otsuka
Publikationsdatum
01.05.2008
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 5/2008
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-008-0611-3

Weitere Artikel der Ausgabe 5/2008

European Spine Journal 5/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.