Skip to main content
Erschienen in: Advances in Therapy 8/2017

30.06.2017 | Original Research

Assessing the Therapeutic Utility of Professional Continuous Glucose Monitoring in Type 2 Diabetes Across Various Therapies: A Retrospective Evaluation

verfasst von: Jothydev Kesavadev, Robert Vigersky, John Shin, Pradeep Babu Sadasivan Pillai, Arun Shankar, Geethu Sanal, Gopika Krishnan, Sunitha Jothydev

Erschienen in: Advances in Therapy | Ausgabe 8/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

There have been few large studies that have analyzed the effect of professional (masked) continuous glucose monitoring (P-CGM) on glycemic control in patients with type 2 diabetes (T2DM) who were on a broad spectrum of baseline therapies.

Methods

We performed a retrospective, blinded evaluation of glycemic control in 296 T2DM adults for 6 months following a 6- to 7-day study of their glycemic profile using masked P-CGM. At baseline, 91% of the patients were on some form of insulin treatment with oral hypoglycemic agents (OHA), while 7% were on one or more OHAs without insulin, and the remaining 2% were on GLP-1RAs. On the basis of the masked CGM profile, patients were counselled on diet and exercise change(s) in their baseline diabetes therapy by our professionally trained diabetes team. They also continued to receive regular treatment advice and dose titrations through our Diabetes Tele-Management System (DTMS®). The baseline changes in hemoglobin A1C (A1C) observed in these patients after 6 months of undergoing P-CGM was compared to a matched control group.

Results

P-CGM revealed that the predominant pattern of hyperglycemia was postprandial while previously unknown hypoglycemia was found in 38% of the patients; over half of the cases of hypoglycemia were nocturnal. The mean A1C of the P-CGM group dropped from 7.5 ± 1.4% at baseline vs. 7.0 ± 0.9% at 6 months (p < 0.0001). The frequency of performing self-monitoring of blood glucose (SMBG) was also found to be significantly increased in these patients from the baseline. Meanwhile, no significant improvement in A1C was noted in the control group during the same time frame (7.7 ± 1.1% at baseline vs. 7.4 ± 1.1% at 6 months; p = 0.0663) and frequency of SMBG remained almost unchanged.

Conclusions

P-CGM can provide actionable data and motivate patients for diabetes self-care practices, resulting in an improvement in glycemic control over a wide range of baseline therapies.
Literatur
1.
Zurück zum Zitat Klonoff DC, Buckingham B, Christiansen JS, et al. Continuous glucose monitoring: an Endocrine Society clinical practice guideline. J Clin Endocrinol Metab. 2011;96(10):2968–79.CrossRefPubMed Klonoff DC, Buckingham B, Christiansen JS, et al. Continuous glucose monitoring: an Endocrine Society clinical practice guideline. J Clin Endocrinol Metab. 2011;96(10):2968–79.CrossRefPubMed
2.
Zurück zum Zitat Grunberger G, Bailey T, Camacho PM, et al. Proceedings from the American Association of Clinical Endocrinologists and American College of Endocrinology consensus conference on glucose monitoring. Endocr Pract. 2015;21(5):522–33.CrossRefPubMed Grunberger G, Bailey T, Camacho PM, et al. Proceedings from the American Association of Clinical Endocrinologists and American College of Endocrinology consensus conference on glucose monitoring. Endocr Pract. 2015;21(5):522–33.CrossRefPubMed
3.
Zurück zum Zitat Inzucchi SE, Bergenstal RM, Buse JB, et al. Management of hyperglycemia in type 2 diabetes, 2015: a patient-centered approach: update to a position statement of the American Diabetes Association and the European Association for the Study of Diabetes. Diabetes Care. 2015;38(1):140–9.CrossRefPubMed Inzucchi SE, Bergenstal RM, Buse JB, et al. Management of hyperglycemia in type 2 diabetes, 2015: a patient-centered approach: update to a position statement of the American Diabetes Association and the European Association for the Study of Diabetes. Diabetes Care. 2015;38(1):140–9.CrossRefPubMed
5.
Zurück zum Zitat Liebl A, Henrichs HR, Heinemann L, Freckmann G, Biermann E, Thomas A. Continuous glucose monitoring: evidence and consensus statement for clinical use. J Diabetes Sci Technol. 2013;7(2):500–19.CrossRefPubMedPubMedCentral Liebl A, Henrichs HR, Heinemann L, Freckmann G, Biermann E, Thomas A. Continuous glucose monitoring: evidence and consensus statement for clinical use. J Diabetes Sci Technol. 2013;7(2):500–19.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Joubert M, Baillot-Rudoni S, Catargi B, et al. Indication, organization, practical implementation and interpretation guidelines for retrospective CGM recording: a French position statement. Diabetes Metab. 2015;41(6):498–508.CrossRefPubMed Joubert M, Baillot-Rudoni S, Catargi B, et al. Indication, organization, practical implementation and interpretation guidelines for retrospective CGM recording: a French position statement. Diabetes Metab. 2015;41(6):498–508.CrossRefPubMed
7.
Zurück zum Zitat Fonseca VA, Grunberger G, Anhalt H, et al. Continuous glucose monitoring: a consensus conference of the American Association of Clinical Endocrinologists and American College of Endocrinology. Endocr Pract. 2016;22(8):1008–21.CrossRefPubMed Fonseca VA, Grunberger G, Anhalt H, et al. Continuous glucose monitoring: a consensus conference of the American Association of Clinical Endocrinologists and American College of Endocrinology. Endocr Pract. 2016;22(8):1008–21.CrossRefPubMed
8.
Zurück zum Zitat Rodbard D, Bailey T, Jovanovic L, Zisser H, Kaplan R, Garg SK. Improved quality of glycemic control and reduced glycemic variability with use of continuous glucose monitoring. Diabetes Technol Ther. 2009;11(11):717–23.CrossRefPubMed Rodbard D, Bailey T, Jovanovic L, Zisser H, Kaplan R, Garg SK. Improved quality of glycemic control and reduced glycemic variability with use of continuous glucose monitoring. Diabetes Technol Ther. 2009;11(11):717–23.CrossRefPubMed
9.
Zurück zum Zitat Garg S, Jovanovic L. Relationship of fasting and hourly blood glucose levels to HbA1c values. Diabetes Care. 2006;29(12):2644–9.CrossRefPubMed Garg S, Jovanovic L. Relationship of fasting and hourly blood glucose levels to HbA1c values. Diabetes Care. 2006;29(12):2644–9.CrossRefPubMed
10.
Zurück zum Zitat Garg SK. The future of glucose monitoring. Diabetes Technol Ther. 2016;18(Suppl 2):S2-iv-S. Garg SK. The future of glucose monitoring. Diabetes Technol Ther. 2016;18(Suppl 2):S2-iv-S.
11.
Zurück zum Zitat Poolsup N, Suksomboon N, Kyaw AM. Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes. Diabetol Metab Syndr. 2013;5(1):39.CrossRefPubMedPubMedCentral Poolsup N, Suksomboon N, Kyaw AM. Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes. Diabetol Metab Syndr. 2013;5(1):39.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Vigersky RA, Fonda SJ, Chellappa M, Walker MS, Ehrhardt NM. Short-and long-term effects of real-time continuous glucose monitoring in patients with type 2 diabetes. Diabetes Care. 2012;35(1):32–8.CrossRefPubMed Vigersky RA, Fonda SJ, Chellappa M, Walker MS, Ehrhardt NM. Short-and long-term effects of real-time continuous glucose monitoring in patients with type 2 diabetes. Diabetes Care. 2012;35(1):32–8.CrossRefPubMed
13.
Zurück zum Zitat Munshi MN, Segal AR, Suhl E, et al. Frequent hypoglycemia among elderly patients with poor glycemic control. Arch Intern Med. 2011;171(4):362–4.CrossRefPubMedPubMedCentral Munshi MN, Segal AR, Suhl E, et al. Frequent hypoglycemia among elderly patients with poor glycemic control. Arch Intern Med. 2011;171(4):362–4.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Gehlaut RR, Dogbey GY, Schwartz FL, Marling CR, Shubrook JH. Hypoglycemia in type 2 diabetes–more common than you think: a continuous glucose monitoring study. J Diabetes Sci Technol. 2015;9(5):999–1005.CrossRefPubMedPubMedCentral Gehlaut RR, Dogbey GY, Schwartz FL, Marling CR, Shubrook JH. Hypoglycemia in type 2 diabetes–more common than you think: a continuous glucose monitoring study. J Diabetes Sci Technol. 2015;9(5):999–1005.CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Allen NA, Fain JA, Braun B, Chipkin SR. Continuous glucose monitoring counseling improves physical activity behaviors of individuals with type 2 diabetes: a randomized clinical trial. Diabetes Res Clin Pract. 2008;80(3):371–9.CrossRefPubMedPubMedCentral Allen NA, Fain JA, Braun B, Chipkin SR. Continuous glucose monitoring counseling improves physical activity behaviors of individuals with type 2 diabetes: a randomized clinical trial. Diabetes Res Clin Pract. 2008;80(3):371–9.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Kim SK, Kim HJ, Kim T, et al. Effectiveness of 3-day continuous glucose monitoring for improving glucose control in type 2 diabetic patients in clinical practice. Diabetes Metab J. 2014;38(6):449–55.CrossRefPubMedPubMedCentral Kim SK, Kim HJ, Kim T, et al. Effectiveness of 3-day continuous glucose monitoring for improving glucose control in type 2 diabetic patients in clinical practice. Diabetes Metab J. 2014;38(6):449–55.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Leinung M, Nardacci E, Patel N, Bettadahalli S, Paika K, Thompson S. Benefits of short-term professional continuous glucose monitoring in clinical practice. Diabetes Technol Ther. 2013;15(9):744–7.CrossRefPubMed Leinung M, Nardacci E, Patel N, Bettadahalli S, Paika K, Thompson S. Benefits of short-term professional continuous glucose monitoring in clinical practice. Diabetes Technol Ther. 2013;15(9):744–7.CrossRefPubMed
18.
Zurück zum Zitat Kesavadev J, Shankar A, Pillai PBS, Krishnan G, Jothydev S. Cost-effective use of telemedicine and self-monitoring of blood glucose via Diabetes Tele Management System (DTMS) to achieve target glycosylated hemoglobin values without serious symptomatic hypoglycemia in 1,000 subjects with Type 2 diabetes mellitus—a retrospective study. Diabetes Technol Ther. 2012;14(9):772–6.CrossRefPubMed Kesavadev J, Shankar A, Pillai PBS, Krishnan G, Jothydev S. Cost-effective use of telemedicine and self-monitoring of blood glucose via Diabetes Tele Management System (DTMS) to achieve target glycosylated hemoglobin values without serious symptomatic hypoglycemia in 1,000 subjects with Type 2 diabetes mellitus—a retrospective study. Diabetes Technol Ther. 2012;14(9):772–6.CrossRefPubMed
19.
Zurück zum Zitat Bode BW, Schwartz S, Stubbs HA, Block JE. Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes: normative values. Diabetes Care. 2005;28(10):2361–6.CrossRefPubMed Bode BW, Schwartz S, Stubbs HA, Block JE. Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes: normative values. Diabetes Care. 2005;28(10):2361–6.CrossRefPubMed
20.
Zurück zum Zitat Blackberry ID, Furler JS, Ginnivan LE, et al. An exploratory trial of basal and prandial insulin initiation and titration for type 2 diabetes in primary care with adjunct retrospective continuous glucose monitoring: INITIATION study. Diabetes Res Clin Pract. 2014;106(2):247–55.CrossRefPubMed Blackberry ID, Furler JS, Ginnivan LE, et al. An exploratory trial of basal and prandial insulin initiation and titration for type 2 diabetes in primary care with adjunct retrospective continuous glucose monitoring: INITIATION study. Diabetes Res Clin Pract. 2014;106(2):247–55.CrossRefPubMed
21.
Zurück zum Zitat Mohan V, Jain S, Kesavadev J, al. Use of retrospective continuous glucose monitoring for optimizing management of type 2 diabetes in India. J Assoc Physicians India. 2016;64:16–21.PubMed Mohan V, Jain S, Kesavadev J, al. Use of retrospective continuous glucose monitoring for optimizing management of type 2 diabetes in India. J Assoc Physicians India. 2016;64:16–21.PubMed
22.
Zurück zum Zitat Hoeks L, Greven W, De Valk H. Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review. Diabet Med. 2011;28(4):386–94.CrossRefPubMed Hoeks L, Greven W, De Valk H. Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review. Diabet Med. 2011;28(4):386–94.CrossRefPubMed
23.
Zurück zum Zitat Pepper GM, Steinsapir J, Reynolds K. Effect of short-term iPRO continuous glucose monitoring on hemoglobin A1c levels in clinical practice. Diabetes Technol Ther. 2012;14(8):654–7.CrossRefPubMed Pepper GM, Steinsapir J, Reynolds K. Effect of short-term iPRO continuous glucose monitoring on hemoglobin A1c levels in clinical practice. Diabetes Technol Ther. 2012;14(8):654–7.CrossRefPubMed
Metadaten
Titel
Assessing the Therapeutic Utility of Professional Continuous Glucose Monitoring in Type 2 Diabetes Across Various Therapies: A Retrospective Evaluation
verfasst von
Jothydev Kesavadev
Robert Vigersky
John Shin
Pradeep Babu Sadasivan Pillai
Arun Shankar
Geethu Sanal
Gopika Krishnan
Sunitha Jothydev
Publikationsdatum
30.06.2017
Verlag
Springer Healthcare
Erschienen in
Advances in Therapy / Ausgabe 8/2017
Print ISSN: 0741-238X
Elektronische ISSN: 1865-8652
DOI
https://doi.org/10.1007/s12325-017-0576-x

Weitere Artikel der Ausgabe 8/2017

Advances in Therapy 8/2017 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.