Skip to main content
Erschienen in: Journal of Medical Systems 3/2012

01.06.2012 | ORIGINAL PAPER

Automatic Detection of the Existence of Subarachnoid Hemorrhage from Clinical CT Images

verfasst von: Yonghong Li, Jianhuang Wu, Hongwei Li, Degang Li, Xiaohua Du, Zhijun Chen, Fucang Jia, Qingmao Hu

Erschienen in: Journal of Medical Systems | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

Subarachnoid hemorrhage (SAH) is a medical emergency which can lead to death or severe disability. Misinterpretation of computed tomography (CT) in patients with SAH is a common problem. How to improve the accuracy of diagnosis is a great challenge to both the clinical physicians and medical researchers. In this paper we proposed a method for the automatic detection of SAH on clinical non-contrast head CT scans. The novelty includes approximation of the subarachnoid space in head CT using an atlas based registration, and exploration of support vector machine to the detection of SAH. The study included 60 patients with SAH and 69 normal controls from clinical hospitals. Thirty patients with SAH and 30 normal controls were used for training, while the rest were used for testing to achieve a testing sensitivity of 100% and specificity of 89.7%. The proposed algorithm might be a potential tool to screen the existence of SAH.
Literatur
1.
Zurück zum Zitat Petrea, R. E., Beiser, A. S., Seshadri, S., Kelly-Hayes, M., Kase, C. S., and Wolf, P. A., Gender differences in stroke incidence and poststroke disability in the framingham heart study. Stroke 40:1032–1037, 2009.CrossRef Petrea, R. E., Beiser, A. S., Seshadri, S., Kelly-Hayes, M., Kase, C. S., and Wolf, P. A., Gender differences in stroke incidence and poststroke disability in the framingham heart study. Stroke 40:1032–1037, 2009.CrossRef
2.
Zurück zum Zitat Van, G. J., Kerr, R. S., and Rinkel, G. J. E., Subarachnoid haemorrhage. Lancet 369:306–318, 2007.CrossRef Van, G. J., Kerr, R. S., and Rinkel, G. J. E., Subarachnoid haemorrhage. Lancet 369:306–318, 2007.CrossRef
3.
Zurück zum Zitat Schievink, W. I., Intracranial aneurysms. N Engl J. Med. 336:28–40, 1997.CrossRef Schievink, W. I., Intracranial aneurysms. N Engl J. Med. 336:28–40, 1997.CrossRef
4.
Zurück zum Zitat Edlow, J. A., Malek, A. M., and Ogilvy, C. S., Aneurysmal subarachnoid hemorrhage: Update for emergency physicians. J. Emerg. Med. 34:237–251, 2008.CrossRef Edlow, J. A., Malek, A. M., and Ogilvy, C. S., Aneurysmal subarachnoid hemorrhage: Update for emergency physicians. J. Emerg. Med. 34:237–251, 2008.CrossRef
5.
Zurück zum Zitat Schwartz, D. T., Sensitivity of computed tomography for subarachnoid hemorrhage. Ann. Emerg. Med. 53:160–161, 2009.CrossRef Schwartz, D. T., Sensitivity of computed tomography for subarachnoid hemorrhage. Ann. Emerg. Med. 53:160–161, 2009.CrossRef
6.
Zurück zum Zitat Chan, T., Computer aided detection of small acute intracranial hemorrhage on computer tomography of brain. Comput. Med. Imaging Graph. 31(4–5):285–298, 2007.CrossRef Chan, T., Computer aided detection of small acute intracranial hemorrhage on computer tomography of brain. Comput. Med. Imaging Graph. 31(4–5):285–298, 2007.CrossRef
7.
Zurück zum Zitat Yuh, E. L., Gean, A. D., Manley, G. T., Callen, A. L., and Wintermark, M., Computer-aided assessment of head computed tomography (CT) studies in patients with suspected traumatic brain injury. J. Neurotrauma 25:1163–1172, 2008.CrossRef Yuh, E. L., Gean, A. D., Manley, G. T., Callen, A. L., and Wintermark, M., Computer-aided assessment of head computed tomography (CT) studies in patients with suspected traumatic brain injury. J. Neurotrauma 25:1163–1172, 2008.CrossRef
8.
Zurück zum Zitat Loncaric, S., Dhawan, A. P., Broderick, J., and Thomas, B., 3-D image analysis of intra-cerebral brain hemorrhage from digitized CT films. Comput. Meth. Programs Biomed. 46(3):207–216, 1995.CrossRef Loncaric, S., Dhawan, A. P., Broderick, J., and Thomas, B., 3-D image analysis of intra-cerebral brain hemorrhage from digitized CT films. Comput. Meth. Programs Biomed. 46(3):207–216, 1995.CrossRef
9.
Zurück zum Zitat Bardera, A., Boada, I., Feixasa, M., Remollob, S., Blascob, G., Silvab, Y., and Pedrazabet, S., Semi-automated method for brain hematoma and edema quantification using computed tomography. Comput. Med. Imaging Graph. 33:304–311, 2009.CrossRef Bardera, A., Boada, I., Feixasa, M., Remollob, S., Blascob, G., Silvab, Y., and Pedrazabet, S., Semi-automated method for brain hematoma and edema quantification using computed tomography. Comput. Med. Imaging Graph. 33:304–311, 2009.CrossRef
10.
Zurück zum Zitat Baldy, R. E., Brindle, G. S., Ewusi-Mensah, I., Jacobson, R., Reveley, M. A., Turner, S. W., and Lishman, W. A., A fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density. Neuroradiology 28(2):109–117, 1986.CrossRef Baldy, R. E., Brindle, G. S., Ewusi-Mensah, I., Jacobson, R., Reveley, M. A., Turner, S. W., and Lishman, W. A., A fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density. Neuroradiology 28(2):109–117, 1986.CrossRef
11.
Zurück zum Zitat Li, Y. H., Jia, F. C., and Hu, Q. M., Several practical problems in clinical head CT image registration. The 4th International Conference on Bioinformatics and Biomedical Engineering (iCBBE), 2010. Li, Y. H., Jia, F. C., and Hu, Q. M., Several practical problems in clinical head CT image registration. The 4th International Conference on Bioinformatics and Biomedical Engineering (iCBBE), 2010.
12.
Zurück zum Zitat Boulfelfel, D., Rangayyan, R. M., Hahn, L. J., Kloiber, R., and Kuduvalli, G. R., Two-dimensional restoration of single photon emission computed tomography images using the kalman filter. IEEE Trans. Med. Imaging 13(1):102–109, 1994.CrossRef Boulfelfel, D., Rangayyan, R. M., Hahn, L. J., Kloiber, R., and Kuduvalli, G. R., Two-dimensional restoration of single photon emission computed tomography images using the kalman filter. IEEE Trans. Med. Imaging 13(1):102–109, 1994.CrossRef
13.
Zurück zum Zitat Toprak, A., and Güler, Ì., Angiograph image restoration with the use of rule base fuzzy 2D Kalman filter. Expert Syst. Appl. 35:1752–1761, 2008.CrossRef Toprak, A., and Güler, Ì., Angiograph image restoration with the use of rule base fuzzy 2D Kalman filter. Expert Syst. Appl. 35:1752–1761, 2008.CrossRef
14.
Zurück zum Zitat Hu, Q. M., Qian, G. Y., Aziz, A., and Nowinski, W. L., Segmentation of brain from computed tomography head images. Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, 3375–3378, 2005. Hu, Q. M., Qian, G. Y., Aziz, A., and Nowinski, W. L., Segmentation of brain from computed tomography head images. Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, 3375–3378, 2005.
15.
Zurück zum Zitat Mazziotta, J. C., Toga, A. W., Evans, A., Fox, P., and Lancaster, J., A probabilistic atlas of the human brain: theory and rationale for its development. The International Consortium for Brain Mapping (ICBM). Neuroimage 2:89–101, 1995.CrossRef Mazziotta, J. C., Toga, A. W., Evans, A., Fox, P., and Lancaster, J., A probabilistic atlas of the human brain: theory and rationale for its development. The International Consortium for Brain Mapping (ICBM). Neuroimage 2:89–101, 1995.CrossRef
16.
Zurück zum Zitat Ibanez, L., Schroeder, W., Ng, L., and Cates, J., The ITK software guide. Kitware Inc, Clifton Park, 2003. Ibanez, L., Schroeder, W., Ng, L., and Cates, J., The ITK software guide. Kitware Inc, Clifton Park, 2003.
17.
Zurück zum Zitat Skilling, J., and Bryan, R. K., Maximum entropy image reconstruction: General algorithm. Mon. Not. R. Astron. Soc. 211:111–124, 1984.MATH Skilling, J., and Bryan, R. K., Maximum entropy image reconstruction: General algorithm. Mon. Not. R. Astron. Soc. 211:111–124, 1984.MATH
18.
Zurück zum Zitat Cortes, C., and Vapnik, V., Support-vector network. Mach. Learn. 273–297, 1995. Cortes, C., and Vapnik, V., Support-vector network. Mach. Learn. 273–297, 1995.
19.
Zurück zum Zitat Vapnik, V., Statistical learning theory, 2nd edition. Wiley, New York, 1998.MATH Vapnik, V., Statistical learning theory, 2nd edition. Wiley, New York, 1998.MATH
20.
Zurück zum Zitat Boser, B. E., Guyon, I. M., and Vapnik, V., A training algorithm for optimal margin classifiers. In Fifth Annual Workshop on Computational Learning Theory. ACM, Pittsburgh, 1992. Boser, B. E., Guyon, I. M., and Vapnik, V., A training algorithm for optimal margin classifiers. In Fifth Annual Workshop on Computational Learning Theory. ACM, Pittsburgh, 1992.
22.
Zurück zum Zitat Duda, R. O., Hart, P. E., and Stork, D. G., Pattern classification. John Wiley & Sons, New York, pp. 483–484, 2001.MATH Duda, R. O., Hart, P. E., and Stork, D. G., Pattern classification. John Wiley & Sons, New York, pp. 483–484, 2001.MATH
Metadaten
Titel
Automatic Detection of the Existence of Subarachnoid Hemorrhage from Clinical CT Images
verfasst von
Yonghong Li
Jianhuang Wu
Hongwei Li
Degang Li
Xiaohua Du
Zhijun Chen
Fucang Jia
Qingmao Hu
Publikationsdatum
01.06.2012
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 3/2012
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-010-9587-8

Weitere Artikel der Ausgabe 3/2012

Journal of Medical Systems 3/2012 Zur Ausgabe