We reviewed 12 male patients with scaphoid nonunions treated by open reduction, bone grafting, and internal fixation with biodegradable implants made of self-reinforced poly-l-lactic acid. Mean patient age was 22.5 (20–25) years. Ten patients had type D2 scaphoid nonunions with a fracture line in the middle one third, one patient had type D2 nonunion with a fracture line in the proximal one third, and one patient had type D1 distal one-third fibrous union. The mean wrist score (modified Mayo wrist score) was 20.8 (10–40) preoperatively and improved after 22–80 months (55–90). All nonunions healed, and the mean solid union time was 4.5 (3.5–7) months. We obtained excellent results in five patients, good results in four, fair results in two, and a poor result in one. The results of this study offer a valid alternative in the fixation of scaphoid nonunions. The major advantage of biodegradable materials is to eliminate the requirement for the removal of the fixation material.
Literatur
1.
Zurück zum Zitat Blasier RD, Bucholz R, Cole W, Johnson LL, Makela EA (1997) Bioresorbable implants: applications in orthopaedic surgery. Instr Course Lect 46:531–546PubMed Blasier RD, Bucholz R, Cole W, Johnson LL, Makela EA (1997) Bioresorbable implants: applications in orthopaedic surgery. Instr Course Lect 46:531–546PubMed
2.
Zurück zum Zitat Böstman OM (1991) Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br 73:679–682PubMed Böstman OM (1991) Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br 73:679–682PubMed
3.
Zurück zum Zitat Böstman OM, Pihlajamaki H (1996) Routine implant removal after fracture surgery: a potentially reducible consumer of hospital resources in trauma units. J Trauma 41:846–849PubMed Böstman OM, Pihlajamaki H (1996) Routine implant removal after fracture surgery: a potentially reducible consumer of hospital resources in trauma units. J Trauma 41:846–849PubMed
4.
Zurück zum Zitat Böstman OM, Makela EA, Tormala P, Rokkanen P (1989) Transphyseal fracture fixation using biodegradable pins. J Bone Joint Surg Br 71:706–707PubMed Böstman OM, Makela EA, Tormala P, Rokkanen P (1989) Transphyseal fracture fixation using biodegradable pins. J Bone Joint Surg Br 71:706–707PubMed
5.
Zurück zum Zitat Böstman OM, Hirvensalo E, Makinen J, Rokkanen P (1990) Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 72:592–596PubMed Böstman OM, Hirvensalo E, Makinen J, Rokkanen P (1990) Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 72:592–596PubMed
6.
Zurück zum Zitat Bucholz RW, Henry S, Henley MB (1994) Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg Am 76:319–324PubMed Bucholz RW, Henry S, Henley MB (1994) Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg Am 76:319–324PubMed
7.
Zurück zum Zitat Herbert TJ, Fisher WE (1984) Management of the fractured scaphoid using a new bone screw. J Bone Joint Surg Br 66:114–123PubMed Herbert TJ, Fisher WE (1984) Management of the fractured scaphoid using a new bone screw. J Bone Joint Surg Br 66:114–123PubMed
8.
Zurück zum Zitat Hopa PG, Williamson DM, Coates CJ, Cole WG (1991) Biodegradable pin fixation of elbow fractures in children. J Bone Joint Surg Br 73:965–968PubMed Hopa PG, Williamson DM, Coates CJ, Cole WG (1991) Biodegradable pin fixation of elbow fractures in children. J Bone Joint Surg Br 73:965–968PubMed
9.
Zurück zum Zitat Juutilainen T, Hirvensalo E, Partio EK, Patiala H, Tormala P, Rokkanen P (2002) Complications in the first 1,043 operations where self-reinforced poly-l-lactide implants were used solely for tissue fixation in orthopaedics and traumatology. Int Orthop 26:122–125CrossRefPubMed Juutilainen T, Hirvensalo E, Partio EK, Patiala H, Tormala P, Rokkanen P (2002) Complications in the first 1,043 operations where self-reinforced poly-l-lactide implants were used solely for tissue fixation in orthopaedics and traumatology. Int Orthop 26:122–125CrossRefPubMed
10.
Zurück zum Zitat Merrell GA, Wolfe SW, Slade JF III (2002) Treatment of scaphoid nonunions: quantitative meta-analysis of the literature. J Hand Surg Am 27:685–691CrossRefPubMed Merrell GA, Wolfe SW, Slade JF III (2002) Treatment of scaphoid nonunions: quantitative meta-analysis of the literature. J Hand Surg Am 27:685–691CrossRefPubMed
11.
Zurück zum Zitat Partio EK, Hirvensalo E, Partio E, Pelttari S, Jukkala-Partio K, Böstman OM et al (1992) Talocrural arthrodesis with absorbable screws, 12 cases followed for 1 year. Acta Orthop Scand 63:170–172PubMed Partio EK, Hirvensalo E, Partio E, Pelttari S, Jukkala-Partio K, Böstman OM et al (1992) Talocrural arthrodesis with absorbable screws, 12 cases followed for 1 year. Acta Orthop Scand 63:170–172PubMed
12.
Zurück zum Zitat Partio EK, Merikanto J, Heikkila JT, Ylinen P, Makela EA, Vainio J et al (1992) Totally absorbable screws in fixation of subtalar extra articular arthrodesis in children with spastic neuromuscular disease. Preliminary report of a randomized prospective study of fourteen arthrodeses fixed with absorbable or metallic screws. J Pediatr Orthop 12:646–650PubMed Partio EK, Merikanto J, Heikkila JT, Ylinen P, Makela EA, Vainio J et al (1992) Totally absorbable screws in fixation of subtalar extra articular arthrodesis in children with spastic neuromuscular disease. Preliminary report of a randomized prospective study of fourteen arthrodeses fixed with absorbable or metallic screws. J Pediatr Orthop 12:646–650PubMed
13.
Zurück zum Zitat Pelto-Vasenius K, Hirvensalo E, Böstman OM, Rokkanen P (1995) Fixation of scaphoid delayed union and nonunion with absorbable polyglycolide pin or Herbert screw. Consolidation and functional results. Arch Orthop Trauma Surg 114:347–351PubMed Pelto-Vasenius K, Hirvensalo E, Böstman OM, Rokkanen P (1995) Fixation of scaphoid delayed union and nonunion with absorbable polyglycolide pin or Herbert screw. Consolidation and functional results. Arch Orthop Trauma Surg 114:347–351PubMed
14.
Zurück zum Zitat Rajagopalan BM, Squire DS, Samuels LO (1999) Results of Herbert-screw fixation with bone-grafting for the treatment of nonunion of the scaphoid. J Bone Joint Surg Am 81:48–52PubMed Rajagopalan BM, Squire DS, Samuels LO (1999) Results of Herbert-screw fixation with bone-grafting for the treatment of nonunion of the scaphoid. J Bone Joint Surg Am 81:48–52PubMed
15.
Zurück zum Zitat Santavirta S, Konttinen YT, Saito T, Gronblad M, Partio E, Kemppinen P et al (1990) Immune response to polyglycolic acid implants. J Bone Joint Surg Br 72:597–600PubMed Santavirta S, Konttinen YT, Saito T, Gronblad M, Partio E, Kemppinen P et al (1990) Immune response to polyglycolic acid implants. J Bone Joint Surg Br 72:597–600PubMed
16.
Zurück zum Zitat Smith BS, Cooney WP (1996) Revision of failed bone grafting for nonunion of the scaphoid. Treatment options and results. Clin Orthop 327:98–109CrossRefPubMed Smith BS, Cooney WP (1996) Revision of failed bone grafting for nonunion of the scaphoid. Treatment options and results. Clin Orthop 327:98–109CrossRefPubMed
Metadaten
Titel
Biodegradable implants in the treatment of scaphoid nonunions
verfasst von
Ibrahim Akmaz
Ahmet Kiral
Ozcan Pehlivan
Mahir Mahirogulları
Can Solakoglu
Osman Rodop
Publikationsdatum
01.10.2004
Erschienen in
International Orthopaedics / Ausgabe 5/2004
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-004-0580-z

Weitere Artikel der Ausgabe 5/2004

International Orthopaedics 5/2004 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.