Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study

verfasst von: Christina A. Niosi, Qingan A. Zhu, Derek C. Wilson, Ory Keynan, David R. Wilson, Thomas R. Oxland

Erschienen in: European Spine Journal | Ausgabe 6/2006

Einloggen, um Zugang zu erhalten

Abstract

The Dynesys, a flexible posterior stabilization system that provides an alternative to fusion, is designed to preserve intersegmental kinematics and alleviate loading at the facet joints. Recent biomechanical evidence suggests that the overall range of motion (ROM) with the Dynesys is less than the intact spine. The purpose of this investigation was to conduct a comprehensive characterization of the three-dimensional kinematic behaviour of the Dynesys and determine if the length of the Dynesys polymer spacer contributes to differences in the kinematic behaviour at the implanted level. Ten cadaveric lumbar spine segments (L2–L5) were tested by applying a pure moment of ±7.5 Nm in flexion–extension, lateral bending, and axial rotation, with and without a follower preload of 600 N. Test conditions included: (a) intact; (b) injury; (c) injury stabilized with Dynesys at L3–L4 (standard spacer); (d) long spacer (+2 mm); and (e) short spacer (−2 mm). Intervertebral rotations were measured using an optoelectronic camera system. The intersegmental range of motion (ROM), neutral zone (NZ), and three-dimensional helical axis of motion (HAM) were calculated. Statistical significance of changes in ROM, NZ, and HAM was determined using repeated measures analysis of variance (ANOVA) and Student–Newman–Keuls post-hoc analysis with P<0.05. Implantation of the standard length Dynesys significantly reduced ROM compared to the intact and injured specimens, with the least significant changes seen in axial rotation. Injury typically increased the NZ, but implantation of the Dynesys restored the NZ to a magnitude less that that of the intact spine. The Dynesys produced a significant posterior shift in the HAM in flexion–extension and axial rotation. The spacer length had a significant effect on ROM with the long spacer resulting in the largest ROM in all loading directions without a follower preload. The largest differences were in axial rotation. A 4 mm increase in spacer length led to an average intersegmental motion increase of 30% in axial rotation, 23% in extension, 14% in flexion, and 11% in lateral bending. There were no significant changes in NZ with different spacer lengths. Typically, the short spacer caused a greater shift and a greater change in orientation of the HAM than the long spacer. The long spacer resulted in a ROM and a motion pattern, as represented by the HAM, that was closer to that seen in an intact specimen. The results of this study suggest that the length of the Dynesys spacer altered the segmental position and therefore affected kinematic behaviour.
Literatur
1.
2.
Zurück zum Zitat Eck JC, Humphreys SC, Hodges SD (1999) Adjacent-segment degeneration after lumbar fusion: a review of clinical, biomechanical, and radiologic studies. Am J Orthop 28:336–340PubMed Eck JC, Humphreys SC, Hodges SD (1999) Adjacent-segment degeneration after lumbar fusion: a review of clinical, biomechanical, and radiologic studies. Am J Orthop 28:336–340PubMed
3.
Zurück zum Zitat Freudiger S, Dubois G, Lorrain M (1999) Dynamic neutralisation of the lumbar spine confirmed on a new lumbar spine simulator in vitro. Arch Orthop Trauma Surg 119:127–132CrossRefPubMed Freudiger S, Dubois G, Lorrain M (1999) Dynamic neutralisation of the lumbar spine confirmed on a new lumbar spine simulator in vitro. Arch Orthop Trauma Surg 119:127–132CrossRefPubMed
4.
Zurück zum Zitat Fritzell P, Hagg O, Wessberg P, et al (2001) Volvo award winner in clinical studies: lumbar fusion versus nonsurgical treatment for chronic low back pain: a multicenter randomized controlled trial from the Swedish Lumbar Spine Study Group. Spine 26:2521–2532 (discussion 32–34)CrossRefPubMed Fritzell P, Hagg O, Wessberg P, et al (2001) Volvo award winner in clinical studies: lumbar fusion versus nonsurgical treatment for chronic low back pain: a multicenter randomized controlled trial from the Swedish Lumbar Spine Study Group. Spine 26:2521–2532 (discussion 32–34)CrossRefPubMed
5.
Zurück zum Zitat Fujiwara A, Lim TH, An HS, et al (2000) The effect of disc degeneration and facet joint osteoarthritis on the segmental flexibility of the lumbar spine. Spine 25:3036–3044CrossRefPubMed Fujiwara A, Lim TH, An HS, et al (2000) The effect of disc degeneration and facet joint osteoarthritis on the segmental flexibility of the lumbar spine. Spine 25:3036–3044CrossRefPubMed
6.
Zurück zum Zitat Gardner-Morse MG, Stokes IA (2003) Physiological axial compressive preloads increase motion segment stiffness, linearity and hysteresis in all six degrees of freedom for small displacements about the neutral posture. J Orthop Res 21:547–552CrossRefPubMed Gardner-Morse MG, Stokes IA (2003) Physiological axial compressive preloads increase motion segment stiffness, linearity and hysteresis in all six degrees of freedom for small displacements about the neutral posture. J Orthop Res 21:547–552CrossRefPubMed
7.
Zurück zum Zitat Goertzen DJ, Lane C, Oxland TR (2004) Neutral zone and range of motion in the spine are greater with stepwise loading than with a continuous loading protocol. An in vitro porcine investigation. J Biomech 37:257–261CrossRefPubMed Goertzen DJ, Lane C, Oxland TR (2004) Neutral zone and range of motion in the spine are greater with stepwise loading than with a continuous loading protocol. An in vitro porcine investigation. J Biomech 37:257–261CrossRefPubMed
8.
Zurück zum Zitat Kinzel GL, Hall AS Jr, Hillberry BM (1972) Measurement of the total motion between two body segments. I. Analytical development. J Biomech 5:93–105CrossRefPubMed Kinzel GL, Hall AS Jr, Hillberry BM (1972) Measurement of the total motion between two body segments. I. Analytical development. J Biomech 5:93–105CrossRefPubMed
9.
Zurück zum Zitat Lee CK (1988) Accelerated degeneration of the segment adjacent to a lumbar fusion. Spine 13:375–377PubMed Lee CK (1988) Accelerated degeneration of the segment adjacent to a lumbar fusion. Spine 13:375–377PubMed
10.
Zurück zum Zitat Lund T, Rathonyi G, Schlenzka D, et al (1999) The external spinal fixator does not reduce anterior column motion under axial compressive loads. A mechanical in vitro study. Acta Orthop Scand 70:37–41PubMed Lund T, Rathonyi G, Schlenzka D, et al (1999) The external spinal fixator does not reduce anterior column motion under axial compressive loads. A mechanical in vitro study. Acta Orthop Scand 70:37–41PubMed
11.
Zurück zum Zitat McKinnon ME, Vickers MR, Ruddock VM, et al (1997) Community studies of the health service implications of low back pain. Spine 22:2161–2166CrossRefPubMed McKinnon ME, Vickers MR, Ruddock VM, et al (1997) Community studies of the health service implications of low back pain. Spine 22:2161–2166CrossRefPubMed
12.
Zurück zum Zitat Mimura M, Panjabi MM, Oxland TR, et al (1994) Disc degeneration affects the multidirectional flexibility of the lumbar spine. Spine 19:1371–1380PubMed Mimura M, Panjabi MM, Oxland TR, et al (1994) Disc degeneration affects the multidirectional flexibility of the lumbar spine. Spine 19:1371–1380PubMed
13.
Zurück zum Zitat Niosi CA, Zhu QA, Wilson DC, et al (2004) Does spacer length of dynamic posterior stablization system have an effect on range of motion? ISSLS 31st Annual Meeting (Poster) Porto, Portugal Niosi CA, Zhu QA, Wilson DC, et al (2004) Does spacer length of dynamic posterior stablization system have an effect on range of motion? ISSLS 31st Annual Meeting (Poster) Porto, Portugal
14.
Zurück zum Zitat Panjabi MM, Krag MH, Goel VK (1981) A technique for measurement and description of three-dimensional six degree-of-freedom motion of a body joint with an application to the human spine. J Biomech 14:447–460CrossRefPubMed Panjabi MM, Krag MH, Goel VK (1981) A technique for measurement and description of three-dimensional six degree-of-freedom motion of a body joint with an application to the human spine. J Biomech 14:447–460CrossRefPubMed
15.
Zurück zum Zitat Panjabi MM, Oxland TR, Yamamoto I, et al (1994) Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load–displacement curves. J Bone Joint Surg Am 76:413–424PubMed Panjabi MM, Oxland TR, Yamamoto I, et al (1994) Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load–displacement curves. J Bone Joint Surg Am 76:413–424PubMed
16.
Zurück zum Zitat Patwardhan AG, Havey RM, Meade KP, et al (1999) A follower load increases the load-carrying capacity of the lumbar spine in compression. Spine 24:1003–1009CrossRefPubMed Patwardhan AG, Havey RM, Meade KP, et al (1999) A follower load increases the load-carrying capacity of the lumbar spine in compression. Spine 24:1003–1009CrossRefPubMed
17.
Zurück zum Zitat Patwardhan AG, Havey RM, Carandang G, et al (2003) Effect of compressive follower preload on the flexion–extension response of the human lumbar spine. J Orthop Res 21:540–546CrossRefPubMed Patwardhan AG, Havey RM, Carandang G, et al (2003) Effect of compressive follower preload on the flexion–extension response of the human lumbar spine. J Orthop Res 21:540–546CrossRefPubMed
18.
Zurück zum Zitat Rohlmann A, Neller S, Claes L, et al (2001) Influence of a follower load on intradiscal pressure and intersegmental rotation of the lumbar spine. Spine 26:E557–E561CrossRefPubMed Rohlmann A, Neller S, Claes L, et al (2001) Influence of a follower load on intradiscal pressure and intersegmental rotation of the lumbar spine. Spine 26:E557–E561CrossRefPubMed
19.
Zurück zum Zitat Schlegel JD, Smith JA, Schleusener RL (1996) Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine 21:970–981CrossRefPubMed Schlegel JD, Smith JA, Schleusener RL (1996) Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine 21:970–981CrossRefPubMed
20.
Zurück zum Zitat Schmoelz W, Huber JF, Nydegger T, et al (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 16:418–23PubMed Schmoelz W, Huber JF, Nydegger T, et al (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 16:418–23PubMed
21.
Zurück zum Zitat Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11(Suppl 2):S170–S178PubMed Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11(Suppl 2):S170–S178PubMed
22.
Zurück zum Zitat Woltring HJ, Huiskes R, de Lange A, et al (1985) Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech 18:379–389CrossRefPubMed Woltring HJ, Huiskes R, de Lange A, et al (1985) Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech 18:379–389CrossRefPubMed
23.
Zurück zum Zitat Yamamoto I, Panjabi MM, Crisco T, et al (1989) Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine 14:1256–1260PubMed Yamamoto I, Panjabi MM, Crisco T, et al (1989) Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine 14:1256–1260PubMed
Metadaten
Titel
Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study
verfasst von
Christina A. Niosi
Qingan A. Zhu
Derek C. Wilson
Ory Keynan
David R. Wilson
Thomas R. Oxland
Publikationsdatum
01.06.2006
Erschienen in
European Spine Journal / Ausgabe 6/2006
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-005-0948-9

Weitere Artikel der Ausgabe 6/2006

European Spine Journal 6/2006 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.