Skip to main content
Erschienen in: European Spine Journal 8/2009

01.08.2009 | Original Article

Biomechanical evaluation of a new fixation device for the thoracic spine

verfasst von: Michio Hongo, Brice Ilharreborde, Ralph E. Gay, Chunfeng Zhao, Kristin D. Zhao, Lawrence J. Berglund, Mark Zobitz, Kai-Nan An

Erschienen in: European Spine Journal | Ausgabe 8/2009

Einloggen, um Zugang zu erhalten

Abstract

The technology used in surgery for spinal deformity has progressed rapidly in recent years. Commonly used fixation techniques may include monofilament wires, sublaminar wires and cables, and pedicle screws. Unfortunately, neurological complications can occur with all of these, compromising the patients’ health and quality of life. Recently, an alternative fixation technique using a metal clamp and polyester belt was developed to replace hooks and sublaminar wiring in scoliosis surgery. The goal of this study was to compare the pull-out strength of this new construct with sublaminar wiring, laminar hooks and pedicle screws. Forty thoracic vertebrae from five fresh frozen human thoracic spines (T5–12) were divided into five groups (8 per group), such that BMD values, pedicle diameter, and vertebral levels were equally distributed. They were then potted in polymethylmethacrylate and anchored with metal screws and polyethylene bands. One of five fixation methods was applied to the right side of the vertebra in each group: Pedicle screw, sublaminar belt with clamp, figure-8 belt with clamp, sublaminar wire, or laminar hook. Pull-out strength was then assessed using a custom jig in a servohydraulic tester. The mean failure load of the pedicle screw group was significantly larger than that of the figure-8 clamp (P = 0.001), sublaminar belt (0.0172), and sublaminar wire groups (P = 0.04) with no significant difference in pull-out strength between the latter three constructs. The most common mode of failure was the fracture of the pedicle. BMD was significantly correlated with failure load only in the figure-8 clamp and pedicle screw constructs. Only the pedicle screw had a statistically significant higher failure load than the sublaminar clamp. The sublaminar method of applying the belt and clamp device was superior to the figure-8 method. The sublaminar belt and clamp construct compared favorably to the traditional methods of sublaminar wires and laminar hooks, and should be considered as an alternative fixation device in the thoracic spine.
Literatur
1.
Zurück zum Zitat Bernard TN Jr, Johnston CE 2nd, Roberts JM, Burke SW (1983) Late complications due to wire breakage in segmental spinal instrumentation. Report of two cases. J Bone Joint Surg Am 65:1339–1345PubMed Bernard TN Jr, Johnston CE 2nd, Roberts JM, Burke SW (1983) Late complications due to wire breakage in segmental spinal instrumentation. Report of two cases. J Bone Joint Surg Am 65:1339–1345PubMed
3.
5.
Zurück zum Zitat Gaines RW Jr (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A:1458–1476PubMed Gaines RW Jr (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A:1458–1476PubMed
6.
11.
12.
Zurück zum Zitat Harrington PR (1962) Treatment of scoliosis. Correction and internal fixation by spine instrumentation. J Bone Joint Surg Am 44-A:591–610PubMed Harrington PR (1962) Treatment of scoliosis. Correction and internal fixation by spine instrumentation. J Bone Joint Surg Am 44-A:591–610PubMed
13.
Zurück zum Zitat Herndon WA, Sullivan JA, Yngve DA, Gross RH, Dreher G (1987) Segmental spinal instrumentation with sublaminar wires. A critical appraisal. J Bone Joint Surg Am 69:851–859PubMed Herndon WA, Sullivan JA, Yngve DA, Gross RH, Dreher G (1987) Segmental spinal instrumentation with sublaminar wires. A critical appraisal. J Bone Joint Surg Am 69:851–859PubMed
14.
Zurück zum Zitat Ilharreborde B, Mazda K (2007) The universal clamp: a new method of thoracic fixation in the treatment of adolescent idiopathic scoliosis. Eur Musculoskeletal Rev 2:66–68 Ilharreborde B, Mazda K (2007) The universal clamp: a new method of thoracic fixation in the treatment of adolescent idiopathic scoliosis. Eur Musculoskeletal Rev 2:66–68
15.
Zurück zum Zitat Johnston CE 2nd, Happel LT Jr, Norris R, Burke SW, King AG, Roberts JM (1986) Delayed paraplegia complicating sublaminar segmental spinal instrumentation. J Bone Joint Surg Am 68:556–563PubMed Johnston CE 2nd, Happel LT Jr, Norris R, Burke SW, King AG, Roberts JM (1986) Delayed paraplegia complicating sublaminar segmental spinal instrumentation. J Bone Joint Surg Am 68:556–563PubMed
17.
Zurück zum Zitat Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed
18.
Zurück zum Zitat Luque ER (1982) Segmental spinal instrumentation for correction of scoliosis. Clin Orthop Relat Res 19:2–198 Luque ER (1982) Segmental spinal instrumentation for correction of scoliosis. Clin Orthop Relat Res 19:2–198
19.
Zurück zum Zitat Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 12:5–141 Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 12:5–141
21.
Zurück zum Zitat Nicastro JF, Hartjen CA, Traina J, Lancaster JM (1986) Intraspinal pathways taken by sublaminar wires during removal. An experimental study. J Bone Joint Surg Am 68:1206–1209PubMed Nicastro JF, Hartjen CA, Traina J, Lancaster JM (1986) Intraspinal pathways taken by sublaminar wires during removal. An experimental study. J Bone Joint Surg Am 68:1206–1209PubMed
24.
Zurück zum Zitat Reulen HJ, Pfaundler S, Ebeling U (1987) The lateral microsurgical approach to the “extracanalicular” lumbar disc herniation. I: A technical note. Acta Neurochir (Wien) 84:64–67. doi:10.1007/BF01456353 CrossRef Reulen HJ, Pfaundler S, Ebeling U (1987) The lateral microsurgical approach to the “extracanalicular” lumbar disc herniation. I: A technical note. Acta Neurochir (Wien) 84:64–67. doi:10.​1007/​BF01456353 CrossRef
25.
Zurück zum Zitat Rittmeister M, Leyendecker K, Kurth A, Schmitt E (1999) Cauda equina compression due to a laminar hook: a late complication of posterior instrumentation in scoliosis surgery. Eur Spine J 8:417–420. doi:90080417.586 [pii]PubMedCrossRef Rittmeister M, Leyendecker K, Kurth A, Schmitt E (1999) Cauda equina compression due to a laminar hook: a late complication of posterior instrumentation in scoliosis surgery. Eur Spine J 8:417–420. doi:90080417.​586 [pii]PubMedCrossRef
29.
Zurück zum Zitat Wilber RG, Thompson GH, Shaffer JW, Brown RH, Nash CL Jr (1984) Postoperative neurological deficits in segmental spinal instrumentation. A study using spinal cord monitoring. J Bone Joint Surg Am 66:1178–1187PubMed Wilber RG, Thompson GH, Shaffer JW, Brown RH, Nash CL Jr (1984) Postoperative neurological deficits in segmental spinal instrumentation. A study using spinal cord monitoring. J Bone Joint Surg Am 66:1178–1187PubMed
Metadaten
Titel
Biomechanical evaluation of a new fixation device for the thoracic spine
verfasst von
Michio Hongo
Brice Ilharreborde
Ralph E. Gay
Chunfeng Zhao
Kristin D. Zhao
Lawrence J. Berglund
Mark Zobitz
Kai-Nan An
Publikationsdatum
01.08.2009
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 8/2009
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-009-0999-4

Weitere Artikel der Ausgabe 8/2009

European Spine Journal 8/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.