Seventy-four total hip arthroplasties using a cementless acetabular component without holes for supplemental screw fixation were evaluated during a follow-up period of 2–6 years. Immediate full weight-bearing walking was allowed after the operation. A comparison of anteroposterior (AP) radiographs of the pelvis taken in the early postoperative period and when the patient returned for the final follow-up revealed that there was no migration of the acetabular component. Based on the early postoperative radiographs and using the zones described by Martell et al. [J Bone Joint Surg (1993) 75-A:554–571], gaps between the acetabular component and the bone occurred at zone A2 in three hips (4.1%), at zone B1 in 12 hips (16.2%), and at zone B2 in seven hips (9.5%). The final follow-up radiographs, however, revealed only one hip to have a gap of 1.1 mm at zone B2; the majority of the gaps had disappeared. The results suggest that immediate weight-bearing walking did not result in the migration of the cementless acetabular component.
Literatur
1.
Zurück zum Zitat Claus AM, Sychterz CJ, Hopper RH Jr, Engh CA (2001) Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10-year follow-up. J Arthroplasty 16[Suppl 1]:177–182PubMedCrossRef Claus AM, Sychterz CJ, Hopper RH Jr, Engh CA (2001) Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10-year follow-up. J Arthroplasty 16[Suppl 1]:177–182PubMedCrossRef
2.
Zurück zum Zitat Clohisy JC, Harris WH (1999) The Harris-Galante porous-coated acetabular component with screw fixation. An average ten-year follow-up study. J Bone Joint Surg 81-A:66–73 Clohisy JC, Harris WH (1999) The Harris-Galante porous-coated acetabular component with screw fixation. An average ten-year follow-up study. J Bone Joint Surg 81-A:66–73
3.
Zurück zum Zitat DeLee JG, Charnley J (1976 ) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32PubMed DeLee JG, Charnley J (1976 ) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32PubMed
4.
Zurück zum Zitat Engh CA, Hopper RH Jr, Engh CA Jr (2004) Long term porous coated cup survivorship using spikes, screws and press-fitting for initial fixation. J Arthroplasty 19[Suppl 2]:54–60PubMedCrossRef Engh CA, Hopper RH Jr, Engh CA Jr (2004) Long term porous coated cup survivorship using spikes, screws and press-fitting for initial fixation. J Arthroplasty 19[Suppl 2]:54–60PubMedCrossRef
5.
Zurück zum Zitat Martell JM, Pierson III RH, Jacobs JJ, Rosenberg AG, Maley M, Galante JO (1993) Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg 75-A:554–571 Martell JM, Pierson III RH, Jacobs JJ, Rosenberg AG, Maley M, Galante JO (1993) Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg 75-A:554–571
6.
Zurück zum Zitat Massin P, Schmidt EA, Engh CA (1989) Evaluation of cementless acetabular component migration. an experimental study. J Arthroplasty 4:245–251PubMedCrossRef Massin P, Schmidt EA, Engh CA (1989) Evaluation of cementless acetabular component migration. an experimental study. J Arthroplasty 4:245–251PubMedCrossRef
7.
Zurück zum Zitat Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws; average ten-year follow-up. J Bone Joint Surg 84-A:1195–A:1200PubMed Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws; average ten-year follow-up. J Bone Joint Surg 84-A:1195–A:1200PubMed
8.
Zurück zum Zitat Valle AGD, Zoppi A, Peterson M, Salvati (2004) Clinical and radiological results associated with a modern cementless modular cup design in total hip arthroplasty. J Bone Joint Surg 86-A:1998–A:2004PubMed Valle AGD, Zoppi A, Peterson M, Salvati (2004) Clinical and radiological results associated with a modern cementless modular cup design in total hip arthroplasty. J Bone Joint Surg 86-A:1998–A:2004PubMed
9.
Zurück zum Zitat Weber D, Schaper LA, Pomeroy DL, Badenhausen Jr WE, Curry JI, Smith MW, Suthers KE (2000) Cementless hemispheric acetabular component in total hip replacement. Int Orthop 24:130–133PubMedCrossRef Weber D, Schaper LA, Pomeroy DL, Badenhausen Jr WE, Curry JI, Smith MW, Suthers KE (2000) Cementless hemispheric acetabular component in total hip replacement. Int Orthop 24:130–133PubMedCrossRef
Metadaten
Titel
Cementless acetabular component inserted without screws – the effect of immediate weight-bearing
verfasst von
F. Y. Ng
Y. Zhu
K. Y. Chiu
Publikationsdatum
01.06.2007
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 3/2007
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0189-5

Weitere Artikel der Ausgabe 3/2007

International Orthopaedics 3/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.