Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 10/2016

08.06.2016 | Symposium: 2015 International Hip Society Proceedings

Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup

verfasst von: Christian P. Delaunay, MD, Sophie Putman, MD, Benjamin Puliéro, MD, Matthieu Bégin, MD, Henri Migaud, MD, François Bonnomet, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 10/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

A primary concern of younger, more active patients who have undergone total hip arthroplasty (THA) is the longevity of the implant. Cementless fixation and hard-on-hard bearings are recognized as options to enhance THA durability. Earlier, we published a series of 83 cementless primary THAs using 28-mm metal-on-metal (MoM) bearings in patients aged 50 years or younger; here we provide concise followup on that same group after an additional 8-year survey period.

Questions/purposes

(1) What is the long-term survivorship of cementless primary THA using 28-mm MoM bearings in patients aged 50 years or younger? (2) What are the clinical and radiographic results of cementless THA in this active patient population? (3) Can any of the observed implant failures or adverse events be attributed to the metallic nature of the bearing couple?

Methods

We retrospectively reviewed 83 cementless THAs performed in three institutions over a decade (1995–2004) in 68 patients with 28-mm MoM articulation. All patients (15 bilateral) had a median age of 42 years (range, 24–50 years) at the time of the index procedure and 56 of them (82% [70 hips]) had activity level graded Devane 4 or 5 before significant hip pain. A 28-mm Metasul™ articulation was used with an Alloclassic-SL™ cementless stem in all cases paired with three different cementless titanium acetabular components (one threaded and two press-fit cups) from the same manufacturer. Survivorship analysis was calculated according to Dobbs life table, patient clinical results were evaluated with use of the Postel-Merle d’Aubigné scoring system, radiographic analysis was performed by independent observers, and cobalt level was determined in whole blood.

Results

The 15-year survivorship (33 hips at risk) for revision for any reasons (four hips) and for aseptic loosening (one hip) was 96% (95% confidence interval [CI], 81%–99%) and 99% (95% CI, 85%–99.9%), respectively. The median Merle d’Aubigné-Postel score remained stable at 17 points (range, 10–18). Thus far, we have not observed pseudotumors or other adverse reactions to metallic debris. Eight hips have undergone reoperation: trochanteric suture removal (one), psoas tendon impingement (two), and five revisions for periprosthetic fracture (one), late infection (two), acetabular osteolysis (one, as a result of polyethylene backside wear), and one hydroxyapatite-coated cup for aseptic loosening. None of the complications, failures, or revisions observed so far could directly be related to the metallic nature of the 28-mm Metasul bearings used in this selected group of patients.

Conclusions

The current survey at 13-year median followup has not yet indicated any long-term deleterious effects related to dissemination of metallic ions. Two senior authors continue to use 28- or 32-mm Metasul™ bearings with cementless THA components in young and active patient populations. Longer followup with a more sophisticated imaging study is necessary to confirm this so far positive report.

Level of Evidence

Level IV, therapeutic study.
Literatur
1.
Zurück zum Zitat Aldinger PR, Thomsen M, Mau H, Ewerbeck V, Breusch SJ. Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand. 2003;74:253–258.CrossRefPubMed Aldinger PR, Thomsen M, Mau H, Ewerbeck V, Breusch SJ. Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand. 2003;74:253–258.CrossRefPubMed
2.
Zurück zum Zitat Amstutz HC, Ball ST, Le Duff MJ, Dorey FJ. Resurfacing THA for patients younger than 50 years. Clin Orthop Relat Res. 2007;460:159–164.PubMed Amstutz HC, Ball ST, Le Duff MJ, Dorey FJ. Resurfacing THA for patients younger than 50 years. Clin Orthop Relat Res. 2007;460:159–164.PubMed
3.
Zurück zum Zitat Brodner W, Grohs JG, Bancher-Todesca D, Dorotka R, Meisinger V, Gottsauner-Wolf F, Kotz R. Does the placenta inhibit the passage of chromium and cobalt after metal-on-metal total hip arthroplasty? J Arthroplasty. 2004;19(Suppl 3):102–106.CrossRefPubMed Brodner W, Grohs JG, Bancher-Todesca D, Dorotka R, Meisinger V, Gottsauner-Wolf F, Kotz R. Does the placenta inhibit the passage of chromium and cobalt after metal-on-metal total hip arthroplasty? J Arthroplasty. 2004;19(Suppl 3):102–106.CrossRefPubMed
4.
Zurück zum Zitat Brooker AF, Bowerman JW, Robinson RA, Riley LH. Ectopic ossification following total hip replacement: incidence and a method of classification. J Bone Joint Surg Am. 1973;55:1629–1632.PubMed Brooker AF, Bowerman JW, Robinson RA, Riley LH. Ectopic ossification following total hip replacement: incidence and a method of classification. J Bone Joint Surg Am. 1973;55:1629–1632.PubMed
5.
Zurück zum Zitat Capello WN, D’Antonio JA, Feinberg JR, Manley MT. Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report. J Bone Joint Surg Am. 2003;85:885–889.PubMed Capello WN, D’Antonio JA, Feinberg JR, Manley MT. Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report. J Bone Joint Surg Am. 2003;85:885–889.PubMed
7.
Zurück zum Zitat Crowther JD, Lachiewicz PF. Survival and polyethylene wear of porous coated acetabular components in patients less than fifty years old: results at nine to fourteen years. J Bone Joint Surg Am. 2002;84:729–735.CrossRefPubMed Crowther JD, Lachiewicz PF. Survival and polyethylene wear of porous coated acetabular components in patients less than fifty years old: results at nine to fourteen years. J Bone Joint Surg Am. 2002;84:729–735.CrossRefPubMed
8.
Zurück zum Zitat Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg Am. 2005;87:18-27.CrossRefPubMed Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg Am. 2005;87:18-27.CrossRefPubMed
9.
Zurück zum Zitat DeKam DCJ, Busch VJJF, Veth RPH, Schreurs BW. Total hip arthroplasties in young patients under 50 years: limited evidence for current trends. A descriptive literature review. Hip Int. 2011;21:518–585. DeKam DCJ, Busch VJJF, Veth RPH, Schreurs BW. Total hip arthroplasties in young patients under 50 years: limited evidence for current trends. A descriptive literature review. Hip Int. 2011;21:518–585.
10.
Zurück zum Zitat Delaunay C. Metal-on-metal bearings in cementless primary total hip arthroplasty. J Arthroplasty. 2004;19(Suppl 3):35–40.CrossRefPubMed Delaunay C. Metal-on-metal bearings in cementless primary total hip arthroplasty. J Arthroplasty. 2004;19(Suppl 3):35–40.CrossRefPubMed
11.
Zurück zum Zitat Delaunay C, Bonnomet F, Clavert P, Laffargue P, Migaud H. THA using metal-on-metal articulation in active patients younger than 50 years. Clin Orthop Relat Res. 2008;466:340–346.CrossRefPubMedPubMedCentral Delaunay C, Bonnomet F, Clavert P, Laffargue P, Migaud H. THA using metal-on-metal articulation in active patients younger than 50 years. Clin Orthop Relat Res. 2008;466:340–346.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Delaunay C, Petit I, Learmonth ID, Oger P, Vendittoli PA. Metal-on metal bearings total hip arthroplasty: the cobalt and chromium ions release concern. Orthop Traumatol Surg Res. 2010;96:894–904.CrossRefPubMed Delaunay C, Petit I, Learmonth ID, Oger P, Vendittoli PA. Metal-on metal bearings total hip arthroplasty: the cobalt and chromium ions release concern. Orthop Traumatol Surg Res. 2010;96:894–904.CrossRefPubMed
13.
Zurück zum Zitat DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
14.
Zurück zum Zitat Department of Orthopaedics, Sahlgrenska University Hospital. The Swedish Hip Arthroplasty Register: Annual Report 2013. Available at: www.jru.orthop.gu.se. Accessed May 2015. Department of Orthopaedics, Sahlgrenska University Hospital. The Swedish Hip Arthroplasty Register: Annual Report 2013. Available at: www.​jru.​orthop.​gu.​se. Accessed May 2015.
15.
Zurück zum Zitat Desmarchelier R, Viste A, Chouteau J, Lerat J-L, Fessy M-H. Metasul versus Cerasul bearings. A prospective, randomized study at 9 years. J Arthroplasty. 2013;28:296.CrossRefPubMed Desmarchelier R, Viste A, Chouteau J, Lerat J-L, Fessy M-H. Metasul versus Cerasul bearings. A prospective, randomized study at 9 years. J Arthroplasty. 2013;28:296.CrossRefPubMed
16.
Zurück zum Zitat Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.CrossRefPubMed Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.CrossRefPubMed
17.
Zurück zum Zitat Dorey F, Nasser S, Amstutz HC. The need for confidence intervals in the presentation of orthopaedic data. J Bone Joint Surg Am. 1993:1844–1852. Dorey F, Nasser S, Amstutz HC. The need for confidence intervals in the presentation of orthopaedic data. J Bone Joint Surg Am. 1993:1844–1852.
18.
Zurück zum Zitat Duffy GP, Prpa B, Rowland CM, Berry DJ. Primary uncemented Harris-Galante acetabular components in patients 50 years old or younger: results at 10 to 12 years. Clin Orthop Relat Res. 2004;427:157–161.CrossRefPubMed Duffy GP, Prpa B, Rowland CM, Berry DJ. Primary uncemented Harris-Galante acetabular components in patients 50 years old or younger: results at 10 to 12 years. Clin Orthop Relat Res. 2004;427:157–161.CrossRefPubMed
19.
Zurück zum Zitat Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990;257:107–128.PubMed Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990;257:107–128.PubMed
20.
Zurück zum Zitat Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P. Total hip arthroplasty for primary osteoarthrosis in younger patients in the Finnish arthroplasty register. 4,661 primary replacements followed for 0-22 years. Acta Orthop. 2005;76:28–41.CrossRefPubMed Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P. Total hip arthroplasty for primary osteoarthrosis in younger patients in the Finnish arthroplasty register. 4,661 primary replacements followed for 0-22 years. Acta Orthop. 2005;76:28–41.CrossRefPubMed
21.
Zurück zum Zitat Halley DK, Glassman AH. Twenty- to twenty-six-year radiographic review in patients 50 years of age or younger with cemented Charnley low-friction arthroplasty. J Arthroplasty. 2003;18(Suppl 1):79–85.CrossRefPubMed Halley DK, Glassman AH. Twenty- to twenty-six-year radiographic review in patients 50 years of age or younger with cemented Charnley low-friction arthroplasty. J Arthroplasty. 2003;18(Suppl 1):79–85.CrossRefPubMed
22.
Zurück zum Zitat Hannemann F, Hartmann A, Schmitt J, Lützner J, Seidler A, Campbell P, Delaunay CP, Drexler H, Ettema HB, Garcia-Cimbrelo E, Huberti H, Knahr K, Kunze J, Langton DJ, Lauer W, Learmonth I, Lohmann CH, Morlock M, Wimmer MA, Zagra L, Günther KP. European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res. 2013;99:263–271.CrossRefPubMed Hannemann F, Hartmann A, Schmitt J, Lützner J, Seidler A, Campbell P, Delaunay CP, Drexler H, Ettema HB, Garcia-Cimbrelo E, Huberti H, Knahr K, Kunze J, Langton DJ, Lauer W, Learmonth I, Lohmann CH, Morlock M, Wimmer MA, Zagra L, Günther KP. European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res. 2013;99:263–271.CrossRefPubMed
23.
Zurück zum Zitat Hartmann A, Hennemann F, Lützner J, Seidler A, Drexler H, Günther K-P, Schmitt J. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearings—systematic review of clinical and epidemiological studies. PLoS One. 2013;8 e70359:1–25. Hartmann A, Hennemann F, Lützner J, Seidler A, Drexler H, Günther K-P, Schmitt J. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearings—systematic review of clinical and epidemiological studies. PLoS One. 2013;8 e70359:1–25.
24.
Zurück zum Zitat Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP. The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am. 2005;87:781–787.CrossRefPubMed Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP. The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am. 2005;87:781–787.CrossRefPubMed
25.
Zurück zum Zitat Huber M, Reinisch G, Zenz P, Zweymüller K, Lintner F. Postmortem study of femoral osteolysis associated with metal-on-metal articulation in total hip replacement. An analysis of nine cases. J Bone Joint Surg Am. 2010;92:1720–1731.CrossRefPubMed Huber M, Reinisch G, Zenz P, Zweymüller K, Lintner F. Postmortem study of femoral osteolysis associated with metal-on-metal articulation in total hip replacement. An analysis of nine cases. J Bone Joint Surg Am. 2010;92:1720–1731.CrossRefPubMed
26.
Zurück zum Zitat Hwang KT, Kim YH, Kim YS, Choi IY. Cementless total hip arthroplasty with a metal-on-metal bearing in patients younger than 50 years. J Arthroplasty. 2011;26:1481–1487.CrossRefPubMed Hwang KT, Kim YH, Kim YS, Choi IY. Cementless total hip arthroplasty with a metal-on-metal bearing in patients younger than 50 years. J Arthroplasty. 2011;26:1481–1487.CrossRefPubMed
27.
Zurück zum Zitat Hwang KT, Kim YH, Kim YS, Ryu JA. Prevalence of a soft-tissue lesion after small head metal-on-metal total hip replacement:13- to 19-year follow-up study. Bone Joint J. 2014;96:1594–1599.CrossRefPubMed Hwang KT, Kim YH, Kim YS, Ryu JA. Prevalence of a soft-tissue lesion after small head metal-on-metal total hip replacement:13- to 19-year follow-up study. Bone Joint J. 2014;96:1594–1599.CrossRefPubMed
28.
Zurück zum Zitat Innmann MM, Gotterbarm T, Kretzer JP, Merle C, Ewerbeck V, Weiss S, Aldinger PR, Streit M. Minimum ten-year results of a 28-mm metal-on-metal bearing in cementless total hip arthroplasty in patients fifty years of age and younger. Int Orthop. 2014;38:920–934.CrossRef Innmann MM, Gotterbarm T, Kretzer JP, Merle C, Ewerbeck V, Weiss S, Aldinger PR, Streit M. Minimum ten-year results of a 28-mm metal-on-metal bearing in cementless total hip arthroplasty in patients fifty years of age and younger. Int Orthop. 2014;38:920–934.CrossRef
29.
Zurück zum Zitat Jacobs JJ, Hallab NJ, Urban RM, Wimmer MA. Wear particles. J Bone Joint Surg Am. 2006;88(Suppl 2):99–102.CrossRefPubMed Jacobs JJ, Hallab NJ, Urban RM, Wimmer MA. Wear particles. J Bone Joint Surg Am. 2006;88(Suppl 2):99–102.CrossRefPubMed
30.
Zurück zum Zitat Jacobs JJ, Skipor AK, Campbell PA, Hallab NJ, Urban RM, Amstutz HC. Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty. 2004;19(Suppl 3):59–65.CrossRefPubMed Jacobs JJ, Skipor AK, Campbell PA, Hallab NJ, Urban RM, Amstutz HC. Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty. 2004;19(Suppl 3):59–65.CrossRefPubMed
31.
Zurück zum Zitat Keener JD, Callaghan JJ, Goetz DD, Pederson DR, Sullivan PM, Johnston RC. Twenty five-year results after Charnley total hip arthroplasty in patients less than fifty years old: a concise follow-up of a previous report. J Bone Joint Surg Am. 2003;85:1066–1072.PubMed Keener JD, Callaghan JJ, Goetz DD, Pederson DR, Sullivan PM, Johnston RC. Twenty five-year results after Charnley total hip arthroplasty in patients less than fifty years old: a concise follow-up of a previous report. J Bone Joint Surg Am. 2003;85:1066–1072.PubMed
32.
Zurück zum Zitat Kerboull L, Hamadouche M, Courpied JP, Kerboull M. Long-term results of Charnley-Kerboull hip arthroplasty in patients younger than 50 years. Clin Orthop Relat Res. 2004;418:112–118.CrossRefPubMed Kerboull L, Hamadouche M, Courpied JP, Kerboull M. Long-term results of Charnley-Kerboull hip arthroplasty in patients younger than 50 years. Clin Orthop Relat Res. 2004;418:112–118.CrossRefPubMed
33.
Zurück zum Zitat Lewthwaite SC, Squires B, Gie GA, Timperley AJ, Ling RS. The Exeter Universal hip in patients 50 years or younger at 10-17 years’ followup. Clin Orthop Relat Res. 2008;466:324–331.CrossRefPubMedPubMedCentral Lewthwaite SC, Squires B, Gie GA, Timperley AJ, Ling RS. The Exeter Universal hip in patients 50 years or younger at 10-17 years’ followup. Clin Orthop Relat Res. 2008;466:324–331.CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Mäkela KT, Visuri T, Pulkkinen P, Eskelinen A, Remes V, Virolainen P, Junnila M, Pukkala E. Cancer incidence and cause-specific mortality in patients with metal-on-metal hip replacements in Finland. A population-based study with a mean follow-up of 4.6 (1-11) years. Acta Orthop. 2014;85:32–38.CrossRefPubMedPubMedCentral Mäkela KT, Visuri T, Pulkkinen P, Eskelinen A, Remes V, Virolainen P, Junnila M, Pukkala E. Cancer incidence and cause-specific mortality in patients with metal-on-metal hip replacements in Finland. A population-based study with a mean follow-up of 4.6 (1-11) years. Acta Orthop. 2014;85:32–38.CrossRefPubMedPubMedCentral
35.
Zurück zum Zitat McAuley JP, Szuszczewicz ES, Young A, Engh CA Sr. Total hip arthroplasty in patients 50 years and younger. Clin Orthop Relat Res. 2004;418:119–125.CrossRefPubMed McAuley JP, Szuszczewicz ES, Young A, Engh CA Sr. Total hip arthroplasty in patients 50 years and younger. Clin Orthop Relat Res. 2004;418:119–125.CrossRefPubMed
36.
Zurück zum Zitat Merle D’Aubigné R. [Numerical classification of the function of the hip. 1970] [in French]. Rev Chir Orthop Reparatrice Appar Mot. 1990;76:371–374. Merle D’Aubigné R. [Numerical classification of the function of the hip. 1970] [in French]. Rev Chir Orthop Reparatrice Appar Mot. 1990;76:371–374.
37.
Zurück zum Zitat Migaud H, Putman S, Krantz N, Vasseur L, Girard J. Cementless metal-on-metal versus ceramic-on-polyethylene hip arthroplasty in patients less than fifty years of age: a comparative study with twelve to fourteen-year follow-up. J Bone Joint Surg Am. 2011;93(Suppl 2):137–142.PubMed Migaud H, Putman S, Krantz N, Vasseur L, Girard J. Cementless metal-on-metal versus ceramic-on-polyethylene hip arthroplasty in patients less than fifty years of age: a comparative study with twelve to fourteen-year follow-up. J Bone Joint Surg Am. 2011;93(Suppl 2):137–142.PubMed
38.
Zurück zum Zitat Muller U, Gautier E, Roeder C, Busato A. The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty. J Bone Joint Surg Br. 2003;85:31–36.CrossRefPubMed Muller U, Gautier E, Roeder C, Busato A. The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty. J Bone Joint Surg Br. 2003;85:31–36.CrossRefPubMed
39.
40.
Zurück zum Zitat Naudie D, Roeder CP, Parvizi J, Berry DJ, Eggli S, Busato A. Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty: a matched case-control study. J Arthroplasty. 2004;19(Suppl 2):35–41.CrossRefPubMed Naudie D, Roeder CP, Parvizi J, Berry DJ, Eggli S, Busato A. Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty: a matched case-control study. J Arthroplasty. 2004;19(Suppl 2):35–41.CrossRefPubMed
41.
Zurück zum Zitat Pedersen AB, Mehnert F, Havelin LI, Furnes O, Herberts P, Kärrholm J, Garellick G, Mäkela K, Eskelinen A, Overgaard S. Association between fixation technique and revision risk in total hip arthroplasty patients younger than 55 years of age. Results from the Nordic Arthroplasty Register Association. Osteoarthritis Cartilage. 2014;22:659–667.CrossRefPubMed Pedersen AB, Mehnert F, Havelin LI, Furnes O, Herberts P, Kärrholm J, Garellick G, Mäkela K, Eskelinen A, Overgaard S. Association between fixation technique and revision risk in total hip arthroplasty patients younger than 55 years of age. Results from the Nordic Arthroplasty Register Association. Osteoarthritis Cartilage. 2014;22:659–667.CrossRefPubMed
42.
Zurück zum Zitat Porter M. Long term outcome of the Charnley hip replacement in the young. Hip Int. 2003;13(Suppl 2):S28–S30.CrossRef Porter M. Long term outcome of the Charnley hip replacement in the young. Hip Int. 2003;13(Suppl 2):S28–S30.CrossRef
43.
Zurück zum Zitat Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Favae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. Wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.CrossRefPubMed Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Favae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. Wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.CrossRefPubMed
44.
Zurück zum Zitat Shetty V, Shitole B, Shetty G, Thakur H, Bhandari M. Optimal bearing surfaces for total hip replacement in the young patient: a meta-analysis. Int Orthop. 2011;35:1281–1287.CrossRefPubMed Shetty V, Shitole B, Shetty G, Thakur H, Bhandari M. Optimal bearing surfaces for total hip replacement in the young patient: a meta-analysis. Int Orthop. 2011;35:1281–1287.CrossRefPubMed
45.
Zurück zum Zitat Shia DS, Clohisy JC, Schinsky MF, Martell JM, Maloney WJ. THA with highly cross-linked polyethylene in patients 50 years or younger. Clin Orthop Relat Res. 2009;467:2059–2065.CrossRefPubMedPubMedCentral Shia DS, Clohisy JC, Schinsky MF, Martell JM, Maloney WJ. THA with highly cross-linked polyethylene in patients 50 years or younger. Clin Orthop Relat Res. 2009;467:2059–2065.CrossRefPubMedPubMedCentral
46.
Zurück zum Zitat Singh S, Trikha SP, Edge AJ. Hydroxyapatite ceramic-coated femoral stems in young patients. A prospective ten-year study. J Bone Joint Surg Br. 2004;86:1118–1123.CrossRefPubMed Singh S, Trikha SP, Edge AJ. Hydroxyapatite ceramic-coated femoral stems in young patients. A prospective ten-year study. J Bone Joint Surg Br. 2004;86:1118–1123.CrossRefPubMed
47.
Zurück zum Zitat Smith SE, Estok DM, Harris WH. 20-year experience with cemented primary and conversion total hip arthroplasty using so-called second-generation cementing techniques in patients aged 50 years or younger. J Arthroplasty. 2000;15:263–273.CrossRefPubMed Smith SE, Estok DM, Harris WH. 20-year experience with cemented primary and conversion total hip arthroplasty using so-called second-generation cementing techniques in patients aged 50 years or younger. J Arthroplasty. 2000;15:263–273.CrossRefPubMed
48.
Zurück zum Zitat Vervest TMJS, Anderson PG. The Zweymüller cementless total hip prosthesis in patients aged 50 years and younger. Hip Int. 2005;15:1–11. Vervest TMJS, Anderson PG. The Zweymüller cementless total hip prosthesis in patients aged 50 years and younger. Hip Int. 2005;15:1–11.
49.
Zurück zum Zitat Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005;87:28–36.CrossRefPubMed Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005;87:28–36.CrossRefPubMed
50.
Zurück zum Zitat Wroblewski BM, Siney PD, Fleming PA. Charnley low-frictional torque arthroplasty in patients under the age of 51 years. Follow-up to 33 years. J Bone Joint Surg Br. 2002;84:540–543.CrossRefPubMed Wroblewski BM, Siney PD, Fleming PA. Charnley low-frictional torque arthroplasty in patients under the age of 51 years. Follow-up to 33 years. J Bone Joint Surg Br. 2002;84:540–543.CrossRefPubMed
51.
Zurück zum Zitat Ziaee H, Daniel J, Datta AK, Blunt S, McMinn DJW. Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty. A controlled study. J Bone Joint Surg Br. 2007;89:301–305.CrossRefPubMed Ziaee H, Daniel J, Datta AK, Blunt S, McMinn DJW. Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty. A controlled study. J Bone Joint Surg Br. 2007;89:301–305.CrossRefPubMed
Metadaten
Titel
Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup
verfasst von
Christian P. Delaunay, MD
Sophie Putman, MD
Benjamin Puliéro, MD
Matthieu Bégin, MD
Henri Migaud, MD
François Bonnomet, MD
Publikationsdatum
08.06.2016
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 10/2016
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-016-4920-2

Weitere Artikel der Ausgabe 10/2016

Clinical Orthopaedics and Related Research® 10/2016 Zur Ausgabe

Symposium: 2015 International Hip Society Proceeding

Editorial Comment: 2015 International Hip Society Proceedings

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie