Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 10/2008

01.10.2008 | Original Article

Changes in Knee Kinematics Reflect the Articular Geometry after Arthroplasty

verfasst von: Anthony M. J. Bull, PhD, Oliver Kessler, MD, Mahbub Alam, FRCS, Andrew A. Amis, DSc(Eng)

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 10/2008

Einloggen, um Zugang zu erhalten

Abstract

We hypothesized changes in rotations and translations after TKA with a fixed-bearing anterior cruciate ligament (ACL)-sacrificing but posterior cruciate ligament (PCL)-retaining design with equal-sized, circular femoral condyles would reflect the changes of articular geometry. Using 8 cadaveric knees, we compared the kinematics of normal knees and TKA in a standardized navigated position with defined loads. The quadriceps was tensed and moments and drawer forces applied during knee flexion-extension while recording the kinematics with the navigation system. TKA caused loss of the screw-home; the flexed tibia remained at the externally rotated position of normal full knee extension with considerably increased external rotation from 63° to 11° extension. The range of internal-external rotation was shifted externally from 30° to 20° extension. There was a small tibial posterior translation from 40° to 90° flexion. The varus-valgus alignment and laxity did not change after TKA. Thus, navigated TKA provided good coronal plane alignment but still lost some aspects of physiologic motion. The loss of tibial screw-home was related to the symmetric femoral condyles, but the posterior translation in flexion was opposite the expected change after TKA with the PCL intact and the ACL excised. Thus, the data confirmed our hypothesis for rotations but not for translations. It is not known whether the standard navigated position provides the best match to physiologic kinematics.
Literatur
1.
Zurück zum Zitat Aglietti P, Buzzi R, Gaudenzi A. Patellofemoral functional results and complications with posterior stabilized total knee prosthesis. J Arthroplasty. 1988;3:17–25.PubMedCrossRef Aglietti P, Buzzi R, Gaudenzi A. Patellofemoral functional results and complications with posterior stabilized total knee prosthesis. J Arthroplasty. 1988;3:17–25.PubMedCrossRef
2.
Zurück zum Zitat Banks SA, Hodge WA. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng. 1996;43:638–649.PubMedCrossRef Banks SA, Hodge WA. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng. 1996;43:638–649.PubMedCrossRef
3.
Zurück zum Zitat Banks SA, Hodge WA. Implant design affects knee arthroplasty kinematics during stair-stepping. Clin Orthop Relat Res. 2004;426:187–193.PubMedCrossRef Banks SA, Hodge WA. Implant design affects knee arthroplasty kinematics during stair-stepping. Clin Orthop Relat Res. 2004;426:187–193.PubMedCrossRef
4.
Zurück zum Zitat Banks SA, Markovich GD, Hodge WA. In-vivo kinematics of cruciate-retaining and substituting knee arthroplasties. J Arthroplasty. 1997;12:297–304.PubMedCrossRef Banks SA, Markovich GD, Hodge WA. In-vivo kinematics of cruciate-retaining and substituting knee arthroplasties. J Arthroplasty. 1997;12:297–304.PubMedCrossRef
5.
Zurück zum Zitat Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L. Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res. 2001;392:46–55.PubMedCrossRef Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L. Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res. 2001;392:46–55.PubMedCrossRef
6.
Zurück zum Zitat Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A. Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty: influence of posterior condylar offset. J Bone Joint Surg Br. 2002;84:50–53.PubMedCrossRef Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A. Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty: influence of posterior condylar offset. J Bone Joint Surg Br. 2002;84:50–53.PubMedCrossRef
7.
Zurück zum Zitat Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res. 1998;356:144–153.PubMedCrossRef Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res. 1998;356:144–153.PubMedCrossRef
8.
Zurück zum Zitat Berger RA, Lyon JH, Jacobs JJ, Barden RM, Berkson EM, Sheinkop MB, Rosenberg AG, Galante JO. Problems with cementless total knee arthroplasty at 11 years followup. Clin Orthop Relat Res. 2001;392:196–207.PubMedCrossRef Berger RA, Lyon JH, Jacobs JJ, Barden RM, Berkson EM, Sheinkop MB, Rosenberg AG, Galante JO. Problems with cementless total knee arthroplasty at 11 years followup. Clin Orthop Relat Res. 2001;392:196–207.PubMedCrossRef
9.
Zurück zum Zitat Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res. 1993;286:40–47.PubMed Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res. 1993;286:40–47.PubMed
10.
Zurück zum Zitat Blankevoort L, Huiskes R, de Lange A. The envelope of passive knee joint motion. J Biomech. 1988;21:705–720.PubMedCrossRef Blankevoort L, Huiskes R, de Lange A. The envelope of passive knee joint motion. J Biomech. 1988;21:705–720.PubMedCrossRef
11.
Zurück zum Zitat Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique: a randomized, prospective trial. J Bone Joint Surg Br. 2004;86:372–377.PubMedCrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique: a randomized, prospective trial. J Bone Joint Surg Br. 2004;86:372–377.PubMedCrossRef
12.
Zurück zum Zitat Churchill DL, Incavo SJ, Johnson CC, Beynnon BD. The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res. 1998;356:111–118.PubMedCrossRef Churchill DL, Incavo SJ, Johnson CC, Beynnon BD. The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res. 1998;356:111–118.PubMedCrossRef
13.
Zurück zum Zitat Daniel DM, Malcom LL, Losse G, Stone ML, Sachs R, Burks R. Instrumented measurement of anterior laxity of the knee. J Bone Joint Surg Am. 1985;67:720–726.PubMed Daniel DM, Malcom LL, Losse G, Stone ML, Sachs R, Burks R. Instrumented measurement of anterior laxity of the knee. J Bone Joint Surg Am. 1985;67:720–726.PubMed
14.
Zurück zum Zitat Dowson D. Biotribology of natural and replacement synovial joints. In: Mow VC, Ratcliffe A, Woo SLY, eds. Biomechanics of Diarthrodial Joints. New York, NY: Springer-Verlag; 1990:305–345. Dowson D. Biotribology of natural and replacement synovial joints. In: Mow VC, Ratcliffe A, Woo SLY, eds. Biomechanics of Diarthrodial Joints. New York, NY: Springer-Verlag; 1990:305–345.
15.
Zurück zum Zitat Figgie HE 3rd, Goldberg VM, Hieple KG, Moller HS 3rd, Gordon NH. The influence of tibial-patellofemoral location on the function of the knee in patients with posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am. 1986;68:1035–1040.PubMed Figgie HE 3rd, Goldberg VM, Hieple KG, Moller HS 3rd, Gordon NH. The influence of tibial-patellofemoral location on the function of the knee in patients with posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am. 1986;68:1035–1040.PubMed
16.
Zurück zum Zitat Fisher J, Dowson D (1991). Tribology of total artificial joints. Proc Inst Mech Eng [H] 205:73–79. Fisher J, Dowson D (1991). Tribology of total artificial joints. Proc Inst Mech Eng [H] 205:73–79.
17.
Zurück zum Zitat Fort-Rodriguez DE, Scuderi GR, Insall JN. Survivorship of cemented total knee arthroplasty. Clin Orthop Relat Res. 1997;345:79–86.CrossRef Fort-Rodriguez DE, Scuderi GR, Insall JN. Survivorship of cemented total knee arthroplasty. Clin Orthop Relat Res. 1997;345:79–86.CrossRef
18.
Zurück zum Zitat Grood ES, Stowers SF, Noyes FR. Limits of movement in the human knee: effect of sectioning the posterior cruciate ligament and posterolateral structures. J Bone Joint Surg Am. 1988;70:88–97.PubMed Grood ES, Stowers SF, Noyes FR. Limits of movement in the human knee: effect of sectioning the posterior cruciate ligament and posterolateral structures. J Bone Joint Surg Am. 1988;70:88–97.PubMed
19.
Zurück zum Zitat Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng. 1983;105:133–144.CrossRef Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng. 1983;105:133–144.CrossRef
20.
Zurück zum Zitat Hallen LG, Lindahl O. The “screw-home” movement in the knee joint. Acta Orthop Scand. 1966;37:97–106.PubMed Hallen LG, Lindahl O. The “screw-home” movement in the knee joint. Acta Orthop Scand. 1966;37:97–106.PubMed
21.
Zurück zum Zitat Hsu HP, Garg A, Walker PS, Spector M, Ewald FC. Effect of knee component alignment on tibial load distribution with clinical correlation. Clin Orthop Relat Res. 1989;248:135–144.PubMed Hsu HP, Garg A, Walker PS, Spector M, Ewald FC. Effect of knee component alignment on tibial load distribution with clinical correlation. Clin Orthop Relat Res. 1989;248:135–144.PubMed
22.
Zurück zum Zitat Incavo SJ, Beynnon BD, Johnson CC, Churchill DL. Knee kinematics in genesis total knee arthroplasty: a comparison of different tibial designs with and without posterior cruciate ligament substitution in cadaveric specimens. Am J Knee Surg. 1997;10:209–215.PubMed Incavo SJ, Beynnon BD, Johnson CC, Churchill DL. Knee kinematics in genesis total knee arthroplasty: a comparison of different tibial designs with and without posterior cruciate ligament substitution in cadaveric specimens. Am J Knee Surg. 1997;10:209–215.PubMed
23.
Zurück zum Zitat Ishii Y, Terajima K, Koga Y, Bechtold JE. Screw home motion after total knee replacement. Clin Orthop Relat Res. 1999;358:181–187.PubMedCrossRef Ishii Y, Terajima K, Koga Y, Bechtold JE. Screw home motion after total knee replacement. Clin Orthop Relat Res. 1999;358:181–187.PubMedCrossRef
24.
Zurück zum Zitat Ishii Y, Terajima K, Terashima S, Koga Y. Three-dimensional kinematics of the human knee with intracortical pin fixation. Clin Orthop Relat Res. 1997;343:144–150.PubMedCrossRef Ishii Y, Terajima K, Terashima S, Koga Y. Three-dimensional kinematics of the human knee with intracortical pin fixation. Clin Orthop Relat Res. 1997;343:144–150.PubMedCrossRef
25.
Zurück zum Zitat Karrholm J, Jonsson H, Nilsson KG, Soderqvist I. Kinematics of successful knee prostheses during weight-bearing: three dimensional movements and positions of screw axes in Tricon-M and Miller-Galante designs. Knee Surg Sports Traumatol Arthrosc. 1994;2:50–59.PubMedCrossRef Karrholm J, Jonsson H, Nilsson KG, Soderqvist I. Kinematics of successful knee prostheses during weight-bearing: three dimensional movements and positions of screw axes in Tricon-M and Miller-Galante designs. Knee Surg Sports Traumatol Arthrosc. 1994;2:50–59.PubMedCrossRef
26.
Zurück zum Zitat Kessler O, Durselen L, Banks S, Mannel H, Marin F. Sagittal curvature of total knee replacements predicts in vivo kinematics. Clin Biomech (Bristol, Avon). 2007;22:52–58CrossRef Kessler O, Durselen L, Banks S, Mannel H, Marin F. Sagittal curvature of total knee replacements predicts in vivo kinematics. Clin Biomech (Bristol, Avon). 2007;22:52–58CrossRef
27.
Zurück zum Zitat Kettelkamp DB, Johnson RJ, Smidt GL, Chao EY, Walker M. An electrogoniometric study of knee motion in normal gait. J Bone Joint Surg Am. 1970;52:775–790.PubMed Kettelkamp DB, Johnson RJ, Smidt GL, Chao EY, Walker M. An electrogoniometric study of knee motion in normal gait. J Bone Joint Surg Am. 1970;52:775–790.PubMed
28.
Zurück zum Zitat Lafortune MA, Cavanagh PR, Sommer HJ 3rd, Kalenak A. Three-dimensional kinematics of the human knee during walking. J Biomech. 1992;25:347–357.PubMedCrossRef Lafortune MA, Cavanagh PR, Sommer HJ 3rd, Kalenak A. Three-dimensional kinematics of the human knee during walking. J Biomech. 1992;25:347–357.PubMedCrossRef
29.
Zurück zum Zitat Merkow RL, Soudry M, Insall JN. Patellar dislocation following total knee replacement. J Bone Joint Surg Am. 1985;67:1321–1327.PubMed Merkow RL, Soudry M, Insall JN. Patellar dislocation following total knee replacement. J Bone Joint Surg Am. 1985;67:1321–1327.PubMed
30.
Zurück zum Zitat Most E, Li G, Schule S, Sultan P, Park SE, Zayontz S, Rubash HE. The kinematics of fixed- and mobile-bearing total knee arthroplasty. Clin Orthop Relat Res. 2003;416:197–207.PubMedCrossRef Most E, Li G, Schule S, Sultan P, Park SE, Zayontz S, Rubash HE. The kinematics of fixed- and mobile-bearing total knee arthroplasty. Clin Orthop Relat Res. 2003;416:197–207.PubMedCrossRef
31.
Zurück zum Zitat Nilsson KG, Karrholm J, Gadegaard P. Abnormal kinematics of the artificial knee: roentgen stereophotogrammetric analysis of 10 Miller-Galante and five New Jersey LCS knees. Acta Orthop Scand. 1991;62:440–446.PubMedCrossRef Nilsson KG, Karrholm J, Gadegaard P. Abnormal kinematics of the artificial knee: roentgen stereophotogrammetric analysis of 10 Miller-Galante and five New Jersey LCS knees. Acta Orthop Scand. 1991;62:440–446.PubMedCrossRef
32.
Zurück zum Zitat Pandit H, Ward T, Hollinghurst D, Beard J, Gill HS, Thomas NP, Murray DW. Influence of surface geometry and cam-post mechanism on the kinematics of total knee replacement. J Bone Joint Surg Br. 2005;87:940–945.PubMedCrossRef Pandit H, Ward T, Hollinghurst D, Beard J, Gill HS, Thomas NP, Murray DW. Influence of surface geometry and cam-post mechanism on the kinematics of total knee replacement. J Bone Joint Surg Br. 2005;87:940–945.PubMedCrossRef
33.
Zurück zum Zitat Piazza SJ, Cavanagh PR. Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment. J Biomech. 2000;33:1029–1034.PubMedCrossRef Piazza SJ, Cavanagh PR. Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment. J Biomech. 2000;33:1029–1034.PubMedCrossRef
34.
Zurück zum Zitat Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, Freeman MA. Does the femur roll-back with flexion? J Bone Joint Surg Br. 2004;86:925–931.PubMedCrossRef Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, Freeman MA. Does the femur roll-back with flexion? J Bone Joint Surg Br. 2004;86:925–931.PubMedCrossRef
35.
Zurück zum Zitat Scarvell JM, Smith PN, Refshauge KM, Galloway HR, Woods KR. Comparison of kinematic analysis by mapping tibiofemoral contact with movement of the femoral condylar centres in healthy and anterior cruciate ligament injured knees. J Orthop Res. 2004;22:955–962.PubMedCrossRef Scarvell JM, Smith PN, Refshauge KM, Galloway HR, Woods KR. Comparison of kinematic analysis by mapping tibiofemoral contact with movement of the femoral condylar centres in healthy and anterior cruciate ligament injured knees. J Orthop Res. 2004;22:955–962.PubMedCrossRef
36.
Zurück zum Zitat Shih YF, Bull AM, Amis AA. The cartilaginous and osseous geometry of the femoral trochlear groove. Knee Surg Sports Traumatol Arthrosc. 2004;12:300–306.PubMedCrossRef Shih YF, Bull AM, Amis AA. The cartilaginous and osseous geometry of the femoral trochlear groove. Knee Surg Sports Traumatol Arthrosc. 2004;12:300–306.PubMedCrossRef
37.
Zurück zum Zitat Stein A, Fleming B, Pope MH, Howe JG. Total knee arthroplasty kinematics: an in vivo evaluation of four different designs. J Arthroplasty. 1988;3(suppl):S31–36.PubMedCrossRef Stein A, Fleming B, Pope MH, Howe JG. Total knee arthroplasty kinematics: an in vivo evaluation of four different designs. J Arthroplasty. 1988;3(suppl):S31–36.PubMedCrossRef
38.
Zurück zum Zitat Stiehl JB, Dennis DA, Komistek RD, Crane HS. In vivo determination of condylar lift-off and screw-home in a mobile bearing total knee arthroplasty. J Arthroplasty. 1999;14:293–299.PubMedCrossRef Stiehl JB, Dennis DA, Komistek RD, Crane HS. In vivo determination of condylar lift-off and screw-home in a mobile bearing total knee arthroplasty. J Arthroplasty. 1999;14:293–299.PubMedCrossRef
39.
Zurück zum Zitat Stiehl JB, Komistek RD, Dennis DA, Paxson RD, Hoff WA. Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br. 1995;77:884–889.PubMed Stiehl JB, Komistek RD, Dennis DA, Paxson RD, Hoff WA. Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br. 1995;77:884–889.PubMed
40.
Zurück zum Zitat Uvehammer J. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Acta Orthop Scand Suppl. 2001;72:1–52.PubMedCrossRef Uvehammer J. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Acta Orthop Scand Suppl. 2001;72:1–52.PubMedCrossRef
41.
Zurück zum Zitat Uvehammer J, Kärrholm J, Brandsson S. In vivo kinematics of total knee arthroplasty: concave versus posterior-stabilised tibial joint surface. J Bone Joint Surg Br. 2000;82:499–505.PubMedCrossRef Uvehammer J, Kärrholm J, Brandsson S. In vivo kinematics of total knee arthroplasty: concave versus posterior-stabilised tibial joint surface. J Bone Joint Surg Br. 2000;82:499–505.PubMedCrossRef
42.
Zurück zum Zitat Uvehammer J, Kärrholm J, Brandsson S, Herberts P, Carlsson L, Karlsson J, Regnér L. In vivo kinematics of total knee arthroplasty: flat compared with concave tibial joint surface. J Orthop Res. 2000;18:856–864.PubMedCrossRef Uvehammer J, Kärrholm J, Brandsson S, Herberts P, Carlsson L, Karlsson J, Regnér L. In vivo kinematics of total knee arthroplasty: flat compared with concave tibial joint surface. J Orthop Res. 2000;18:856–864.PubMedCrossRef
43.
Zurück zum Zitat Vince KG, Insall JN, Kelly MA. The total condylar prosthesis: 10- to 12-year results of a cemented knee replacement. J Bone Joint Surg Br. 1989;71:793–797.PubMed Vince KG, Insall JN, Kelly MA. The total condylar prosthesis: 10- to 12-year results of a cemented knee replacement. J Bone Joint Surg Br. 1989;71:793–797.PubMed
44.
Zurück zum Zitat Weir DJ, Moran CG, Pinder IM. Kinematic condylar total knee arthroplasty: 14-year survivorship analysis of 208 consecutive cases. J Bone Joint Surg Br. 1996;78:907–911.PubMedCrossRef Weir DJ, Moran CG, Pinder IM. Kinematic condylar total knee arthroplasty: 14-year survivorship analysis of 208 consecutive cases. J Bone Joint Surg Br. 1996;78:907–911.PubMedCrossRef
45.
Zurück zum Zitat Whiteside LA, Kasselt MR, Haynes DW. Varus-valgus and rotational stability in rotationally unconstrained total knee arthroplasty. Clin Orthop Relat Res. 1987;219:47–157.PubMed Whiteside LA, Kasselt MR, Haynes DW. Varus-valgus and rotational stability in rotationally unconstrained total knee arthroplasty. Clin Orthop Relat Res. 1987;219:47–157.PubMed
46.
Zurück zum Zitat Wimmer MA, Andriacchi TP. Tractive forces during rolling motion of the knee: implications for wear in total knee replacement. J Biomech. 1997;30:131–137.PubMedCrossRef Wimmer MA, Andriacchi TP. Tractive forces during rolling motion of the knee: implications for wear in total knee replacement. J Biomech. 1997;30:131–137.PubMedCrossRef
Metadaten
Titel
Changes in Knee Kinematics Reflect the Articular Geometry after Arthroplasty
verfasst von
Anthony M. J. Bull, PhD
Oliver Kessler, MD
Mahbub Alam, FRCS
Andrew A. Amis, DSc(Eng)
Publikationsdatum
01.10.2008
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 10/2008
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0440-z

Weitere Artikel der Ausgabe 10/2008

Clinical Orthopaedics and Related Research® 10/2008 Zur Ausgabe

Symposium: ABJS/C.T. Brighton Workshop on Trauma in the Developing World

Musculoskeletal Trauma Services in Mozambique and Sri Lanka

Symposium: ABJS/C.T. Brighton Workshop on Trauma in the Developing World

Musculoskeletal Trauma Service in Thailand

Symposium: ABJS/C.T. Brighton Workshop on Trauma in the Developing World

Topics in Global Public Health

Symposium: ABJS/C.T. Brighton Workshop on Trauma in the Developing World

Musculoskeletal Training for Orthopaedists and Nonorthopaedists in China

Symposium: ABJS/C.T. Brighton Workshop on Trauma in the Developing World

Trauma Training for Nonorthopaedic Doctors in Low- and Middle-income Countries

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.