Skip to main content
Erschienen in: Clinical Oral Investigations 3/2007

01.09.2007 | Original Article

Clinical study on the primary stability of two dental implant systems with resonance frequency analysis

verfasst von: Annette Rabel, Steffen Gerhard Köhler, Andrea Maria Schmidt-Westhausen

Erschienen in: Clinical Oral Investigations | Ausgabe 3/2007

Einloggen, um Zugang zu erhalten

Abstract

Primary stability has a major impact on the long-term success of dental implants. The aim of this study was to investigate the correlation of resonance frequency analysis (RFA) and insertion torque of self-tapping and non-self-tapping implants and their respective differences in primary stability. A group of 263 patients were treated with a total of 602 conically formed dental implants: 408 non-self-tapping Ankylos® and 194 self-tapping Camlog®. The maximum insertion torque during implant placement was recorded. Resonance frequency, measured as the implant stability quotient (ISQ), was assessed once immediately after insertion and twice 3 months later. Torque values of the non-self-tapping implants were significantly higher than those in the self-tapping group (p = 0.023). RFA did not show differences between the 2 groups (p = 0.956), but a correlation between ISQ values after implantation and 3 months after implant placement was measured (r = 0.712). Within the implant systems, no correlation between insertion torque and resonance frequency values could be determined (r = 0.305). Our study indicates that the ISQ values obtained from different implant systems are not comparable. The RFA does not appear suitable for the evaluation of implant stability when used as a single method. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical primary stability.
Literatur
1.
Zurück zum Zitat Akca K, Akkocaoglu M, Comert A, Tekdemir I, Cehreli MC (2005) Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures. Clin Oral Implants Res 16(6):715–722PubMedCrossRef Akca K, Akkocaoglu M, Comert A, Tekdemir I, Cehreli MC (2005) Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures. Clin Oral Implants Res 16(6):715–722PubMedCrossRef
2.
Zurück zum Zitat Akkocaoglu M, Uysal S, Tekdemir I, Akca K, Cehreli MC (2005) Implant design and intraosseous stability of immediately placed implants: a human cadaver study. Clin Oral Implants Res 16(2):202–209PubMedCrossRef Akkocaoglu M, Uysal S, Tekdemir I, Akca K, Cehreli MC (2005) Implant design and intraosseous stability of immediately placed implants: a human cadaver study. Clin Oral Implants Res 16(2):202–209PubMedCrossRef
3.
Zurück zum Zitat Al-Nawas B, Brahm R, Grötz KA (2002) Resonanzfrequenzanalyse zur non-invasiven Analyse der Primärstabilität enossaler Implantate in vivo. Z Zahnärztl Implantol 18:142–148 Al-Nawas B, Brahm R, Grötz KA (2002) Resonanzfrequenzanalyse zur non-invasiven Analyse der Primärstabilität enossaler Implantate in vivo. Z Zahnärztl Implantol 18:142–148
4.
Zurück zum Zitat Bähr W (1992) Comparison of torque measurements between cortical screws and emergency replacement screws in the cadaver mandible. J Oral Maxillofac Surg 50(1):46–49PubMedCrossRef Bähr W (1992) Comparison of torque measurements between cortical screws and emergency replacement screws in the cadaver mandible. J Oral Maxillofac Surg 50(1):46–49PubMedCrossRef
5.
Zurück zum Zitat Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A (2002) Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study. Clin Implant Dent Relat Res 4(3):128–132PubMedCrossRef Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A (2002) Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study. Clin Implant Dent Relat Res 4(3):128–132PubMedCrossRef
6.
Zurück zum Zitat Beer A, Gahleitner A, Holm A, Tschabitscher M, Homolka P (2003) Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible. Clin Oral Implants Res 14(5):616–620PubMedCrossRef Beer A, Gahleitner A, Holm A, Tschabitscher M, Homolka P (2003) Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible. Clin Oral Implants Res 14(5):616–620PubMedCrossRef
7.
Zurück zum Zitat Becker W, Sennerby L, Bedrossian E, Becker BE, Lucchini JP (2005) Implant stability measurements for implants placed at the time of extraction: a cohort, prospective clinical trial. J Periodontol 76(3):391–397PubMedCrossRef Becker W, Sennerby L, Bedrossian E, Becker BE, Lucchini JP (2005) Implant stability measurements for implants placed at the time of extraction: a cohort, prospective clinical trial. J Periodontol 76(3):391–397PubMedCrossRef
8.
Zurück zum Zitat Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J (2004) Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 15(5):529–539PubMedCrossRef Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J (2004) Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 15(5):529–539PubMedCrossRef
9.
Zurück zum Zitat Büchter A, Kleinheinz J, Joos U, Meyer U (2003) Primary implant stability with different bone surgery techniques. An in vitro study of the mandible of the minipig. Mund Kiefer Gesichtschir 7(6):351–355PubMedCrossRef Büchter A, Kleinheinz J, Joos U, Meyer U (2003) Primary implant stability with different bone surgery techniques. An in vitro study of the mandible of the minipig. Mund Kiefer Gesichtschir 7(6):351–355PubMedCrossRef
10.
Zurück zum Zitat da Cunha HA, Francischone CE, Filho HN, de Oliveira RC (2004) A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. Int J Oral Maxillofac Implants 19(4):578–585PubMed da Cunha HA, Francischone CE, Filho HN, de Oliveira RC (2004) A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. Int J Oral Maxillofac Implants 19(4):578–585PubMed
11.
Zurück zum Zitat Ersanli S, Karabuda C, Beck F, Leblebicioglu B (2005) Resonance frequency analysis of one-stage dental implant stability during the osseointegration period. J Periodontol 76(7):1066–1071PubMedCrossRef Ersanli S, Karabuda C, Beck F, Leblebicioglu B (2005) Resonance frequency analysis of one-stage dental implant stability during the osseointegration period. J Periodontol 76(7):1066–1071PubMedCrossRef
12.
Zurück zum Zitat Friberg B, Jemt T, Lekholm U (1991) Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 surgery to the connection of completed protheses. Int J Oral Maxillofac Implants 6(2):142–146PubMed Friberg B, Jemt T, Lekholm U (1991) Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 surgery to the connection of completed protheses. Int J Oral Maxillofac Implants 6(2):142–146PubMed
13.
Zurück zum Zitat Friberg B, Sennerby L, Meredith N, Lekholm U (1999) A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 28(4):297–303PubMedCrossRef Friberg B, Sennerby L, Meredith N, Lekholm U (1999) A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 28(4):297–303PubMedCrossRef
14.
Zurück zum Zitat Friberg B, Sennerby L, Roos J, Johansson P, Strid CG, Lekholm U (1995) Evaluation of bone density using cutting resistance and microradiography: an in vitro study in pig ribs. Clin Oral Implants Res 6(3):164–171PubMedCrossRef Friberg B, Sennerby L, Roos J, Johansson P, Strid CG, Lekholm U (1995) Evaluation of bone density using cutting resistance and microradiography: an in vitro study in pig ribs. Clin Oral Implants Res 6(3):164–171PubMedCrossRef
15.
Zurück zum Zitat Friberg B, Sennerby L, Roos J, Lekholm U (1995) Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens. Clin Oral Implants Res 6(4):213–219PubMedCrossRef Friberg B, Sennerby L, Roos J, Lekholm U (1995) Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens. Clin Oral Implants Res 6(4):213–219PubMedCrossRef
16.
Zurück zum Zitat Glauser R, Sennerby L, Meredith N, Ree A, Lundgren A, Gottlow J, Hammerle CH (2004) Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 15(4):428–434PubMedCrossRef Glauser R, Sennerby L, Meredith N, Ree A, Lundgren A, Gottlow J, Hammerle CH (2004) Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 15(4):428–434PubMedCrossRef
17.
Zurück zum Zitat Homolka P, Beer A, Birkfellner W, Nowotny R, Gahleitner A, Tschabitscher M, Bergmann H (2002) Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study. Radiology 224(1):247–252PubMedCrossRef Homolka P, Beer A, Birkfellner W, Nowotny R, Gahleitner A, Tschabitscher M, Bergmann H (2002) Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study. Radiology 224(1):247–252PubMedCrossRef
18.
Zurück zum Zitat Horwitz J, Zuabi O, Peled M (2003) Resonance frequency analysis in immediate loading of dental implants. Refuat Hapeh Vehashinayim 20(3):80–88, 104 Horwitz J, Zuabi O, Peled M (2003) Resonance frequency analysis in immediate loading of dental implants. Refuat Hapeh Vehashinayim 20(3):80–88, 104
19.
Zurück zum Zitat Huang HM, Chiu CL, Yeh CY, Lee SY (2003) Factors influencing the resonance frequency of dental implants. J Oral Maxillofac Surg 61(10):1184–1188PubMedCrossRef Huang HM, Chiu CL, Yeh CY, Lee SY (2003) Factors influencing the resonance frequency of dental implants. J Oral Maxillofac Surg 61(10):1184–1188PubMedCrossRef
20.
Zurück zum Zitat Huang HM, Lee SY, Yeh CY, Lin CT (2002) Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Implants Res 13(1):65–74PubMedCrossRef Huang HM, Lee SY, Yeh CY, Lin CT (2002) Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Implants Res 13(1):65–74PubMedCrossRef
21.
Zurück zum Zitat Ivanoff CJ, Sennerby L, Lekholm U (1996) Influence of mono- and bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia. Int J Oral Maxillofac Surg 25(3):229–235PubMedCrossRef Ivanoff CJ, Sennerby L, Lekholm U (1996) Influence of mono- and bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia. Int J Oral Maxillofac Surg 25(3):229–235PubMedCrossRef
22.
Zurück zum Zitat Johansson P, Strid KG (1994) Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Implants 9:279–288 Johansson P, Strid KG (1994) Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Implants 9:279–288
23.
Zurück zum Zitat Lachmann S, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H (2006) Resonance frequency analysis and damping capacity assessment. Part 1: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 17(1):75–79PubMedCrossRef Lachmann S, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H (2006) Resonance frequency analysis and damping capacity assessment. Part 1: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 17(1):75–79PubMedCrossRef
24.
Zurück zum Zitat Lachmann S, Laval JY, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H (2006) Resonance frequency analysis and damping capacity assessment. Part 2: peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments. Clin Oral Implants Res 17(1):80–84PubMedCrossRef Lachmann S, Laval JY, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H (2006) Resonance frequency analysis and damping capacity assessment. Part 2: peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments. Clin Oral Implants Res 17(1):80–84PubMedCrossRef
25.
Zurück zum Zitat Lekholm U, Zarb GA (1985) Patient selection and preparation. In: Brånemark PI, Zarb GA, Albrektson T (eds) Tissue-integrated protheses: osseointegration in clinical dentistry. Quintessence, Chicago, pp 199–209 Lekholm U, Zarb GA (1985) Patient selection and preparation. In: Brånemark PI, Zarb GA, Albrektson T (eds) Tissue-integrated protheses: osseointegration in clinical dentistry. Quintessence, Chicago, pp 199–209
26.
Zurück zum Zitat Meredith N (1998) Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11(5):491–501PubMed Meredith N (1998) Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11(5):491–501PubMed
27.
Zurück zum Zitat Meredith N, Alleyne D, Cawley P (1996) Quantitative determination of the stability of the implant–tissue interface using resonance frequency analysis. Clin Oral Implants Res 7(3):261–267PubMedCrossRef Meredith N, Alleyne D, Cawley P (1996) Quantitative determination of the stability of the implant–tissue interface using resonance frequency analysis. Clin Oral Implants Res 7(3):261–267PubMedCrossRef
28.
Zurück zum Zitat Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T (2005) Influence of cortical bone thickness and implant length on implant stability at the time of surgery—clinical, prospective, biomechanical, and imaging study. Bone 37(6):776–780PubMedCrossRef Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T (2005) Influence of cortical bone thickness and implant length on implant stability at the time of surgery—clinical, prospective, biomechanical, and imaging study. Bone 37(6):776–780PubMedCrossRef
29.
Zurück zum Zitat Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J (2004) Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 15(5):520–528PubMedCrossRef Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J (2004) Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 15(5):520–528PubMedCrossRef
30.
Zurück zum Zitat Nentwig GH (2004) Ankylos implant system: concept and clinical application. J Oral Implantol 30(3):171–177PubMedCrossRef Nentwig GH (2004) Ankylos implant system: concept and clinical application. J Oral Implantol 30(3):171–177PubMedCrossRef
31.
Zurück zum Zitat Neugebauer J, Traini T, Thams U, Piattelli A, Zoller JE (2006) Peri-implant bone organization under immediate loading state. Circularly polarized light analyses: a minipig study. J Periodontol 77(2):152–160PubMedCrossRef Neugebauer J, Traini T, Thams U, Piattelli A, Zoller JE (2006) Peri-implant bone organization under immediate loading state. Circularly polarized light analyses: a minipig study. J Periodontol 77(2):152–160PubMedCrossRef
32.
Zurück zum Zitat Ostman PO, Hellman M, Sennerby L (2005) Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion. Clin Implant Dent Relat Res 7(Suppl 1):S60–S69PubMedCrossRef Ostman PO, Hellman M, Sennerby L (2005) Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion. Clin Implant Dent Relat Res 7(Suppl 1):S60–S69PubMedCrossRef
33.
Zurück zum Zitat Ostman PO, Hellman M, Wendelhag I, Sennerby L (2006) Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont 19(1):77–83, discussion 84PubMed Ostman PO, Hellman M, Wendelhag I, Sennerby L (2006) Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont 19(1):77–83, discussion 84PubMed
34.
Zurück zum Zitat O’Sullivan D, Sennerby L, Meredith N (2000) Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res 2(2):85–92PubMedCrossRef O’Sullivan D, Sennerby L, Meredith N (2000) Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res 2(2):85–92PubMedCrossRef
35.
Zurück zum Zitat O’Sullivan D, Sennerby L, Meredith N (2004) Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 15(4):474–480PubMedCrossRef O’Sullivan D, Sennerby L, Meredith N (2004) Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 15(4):474–480PubMedCrossRef
36.
Zurück zum Zitat Ottoni JM, Oliveira ZF, Mansini R, Cabral AM (2005) Correlation between placement torque and survival of single-tooth implants. Int J Oral Maxillofac Implants 20(5):769–776PubMed Ottoni JM, Oliveira ZF, Mansini R, Cabral AM (2005) Correlation between placement torque and survival of single-tooth implants. Int J Oral Maxillofac Implants 20(5):769–776PubMed
37.
Zurück zum Zitat Sakoh J, Wahlmann U, Stender E, Nat R, Al-Nawas B, Wagner W (2006) Primary stability of a conical implant and a hybrid, cylindric screw-type implant in vitro. Int J Oral Maxillofac Implants 4(21):560–566 Sakoh J, Wahlmann U, Stender E, Nat R, Al-Nawas B, Wagner W (2006) Primary stability of a conical implant and a hybrid, cylindric screw-type implant in vitro. Int J Oral Maxillofac Implants 4(21):560–566
38.
Zurück zum Zitat Schmid MR, Schiel HJ, Lambrecht JT (2002) Torque of endosseous dental screw type implants. Schweiz Monatsschr Zahnmed 112(8):804–813PubMed Schmid MR, Schiel HJ, Lambrecht JT (2002) Torque of endosseous dental screw type implants. Schweiz Monatsschr Zahnmed 112(8):804–813PubMed
39.
Zurück zum Zitat Schroeder A, Stich H, Straumann F, Sutter F (1978) Über die Anlagerung von Osteozement an einen belasteten Implantatkörper. Schweiz Monatsschr Zahnmed 88(10):1051–1058 Schroeder A, Stich H, Straumann F, Sutter F (1978) Über die Anlagerung von Osteozement an einen belasteten Implantatkörper. Schweiz Monatsschr Zahnmed 88(10):1051–1058
40.
Zurück zum Zitat Traini T, Assenza B, San Roman F, Thams U, Caputi S, Piattelli A (2006) Bone microvascular pattern around loaded dental implants in a canine model. Clin Oral Investig 10(2):151–156PubMedCrossRef Traini T, Assenza B, San Roman F, Thams U, Caputi S, Piattelli A (2006) Bone microvascular pattern around loaded dental implants in a canine model. Clin Oral Investig 10(2):151–156PubMedCrossRef
41.
Zurück zum Zitat Trisi P, Rao W (1999) Bone classification: clinical-histomorphometric comparison. Clin Oral Implants Res 10(1):1–7PubMedCrossRef Trisi P, Rao W (1999) Bone classification: clinical-histomorphometric comparison. Clin Oral Implants Res 10(1):1–7PubMedCrossRef
42.
Zurück zum Zitat Turkyilmaz I, Tozum TF, Tumer C, Ozbek EN (2006) Assessment of correlation between computerized tomography values of bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil 33(12):881–888PubMedCrossRef Turkyilmaz I, Tozum TF, Tumer C, Ozbek EN (2006) Assessment of correlation between computerized tomography values of bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil 33(12):881–888PubMedCrossRef
43.
Zurück zum Zitat Zix J, Kessler-Liechti G, Mericske-Stern R (2005) Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. Int J Oral Maxillofac Implants 20(5):747–752PubMed Zix J, Kessler-Liechti G, Mericske-Stern R (2005) Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. Int J Oral Maxillofac Implants 20(5):747–752PubMed
Metadaten
Titel
Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
verfasst von
Annette Rabel
Steffen Gerhard Köhler
Andrea Maria Schmidt-Westhausen
Publikationsdatum
01.09.2007
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 3/2007
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-007-0115-2

Weitere Artikel der Ausgabe 3/2007

Clinical Oral Investigations 3/2007 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.