Closure of Interatrial Defects by Immediate-Release Patch

verfasst von: Aliakbar Zeinaloo, Keyhan Sayadpour Zanjani, Bahman Rastkar, Alimohammad Hajizeinali, Bahram Sohrabi, Mahmoud Samadi, Eleftherios B. Sideris

Erschienen in: Pediatric Cardiology | Ausgabe 8/2012

Einloggen, um Zugang zu erhalten

Abstract

The Immediate-Release Patch is the newest version of the Transcatheter Patch, which is a bioabsorbable device for the closure of cardiac defects. Closure of 12 atrial septal defects and 1 fenestration was attempted using this device. Of the 13 devices used, 12 were implanted successfully (including that for the fenestration), whereas 1 device moved from the original position and was retrieved percutaneously. No other major adverse events occurred. After a median follow-up period of 11 months, trivial (≤2-mm) residual shunts remained in two patients, and a significant residual defect (7 mm) remained in 1 patient. The major advantages of this device include its wirelessness, its bioabsorbablity, potential application for defects up to 30 mm using only three sizes, its easier retrieval, and its ability to occlude defects with a deficient rim and some ostium primum and sinus venosus type defects. In contrast to the metal devices, it is bulkier and has a different application method requiring operator familiarity, and it sometimes leaves residual shunts.
Literatur
1.
Zurück zum Zitat Sideris EB, Macuil B, Sideris VE, Moulopoulos SD (2005) Abstracts of the 54th Annual Scientific Session of the American College of Cardiology, 6–9 March 2005, Orlando. J Am Coll Cardiol 45:1A–446A Sideris EB, Macuil B, Sideris VE, Moulopoulos SD (2005) Abstracts of the 54th Annual Scientific Session of the American College of Cardiology, 6–9 March 2005, Orlando. J Am Coll Cardiol 45:1A–446A
2.
Zurück zum Zitat Calachanis M, Macuil B, Zamora R, Coulson J, Toumanides S, Sideris E (2007) Effectiveness of transcatheter patch release with surgical adhesives in the occlusion of heart defects. Abstracts of the 42nd Annual Meeting of the Association for European Paediatric Cardiology, 16–19 May 2007, Warsaw, Poland. Cardiol Young 17(Suppl 1):1–99 Calachanis M, Macuil B, Zamora R, Coulson J, Toumanides S, Sideris E (2007) Effectiveness of transcatheter patch release with surgical adhesives in the occlusion of heart defects. Abstracts of the 42nd Annual Meeting of the Association for European Paediatric Cardiology, 16–19 May 2007, Warsaw, Poland. Cardiol Young 17(Suppl 1):1–99
3.
Zurück zum Zitat Amin Z, Hijazi ZM, Bass JL, Cheatham JP, Hellenbrand WE, Kleinman CS (2004) Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 63:496–502PubMedCrossRef Amin Z, Hijazi ZM, Bass JL, Cheatham JP, Hellenbrand WE, Kleinman CS (2004) Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 63:496–502PubMedCrossRef
4.
Zurück zum Zitat DiBardino DJ, McElhinney DB, Kaza AK, Mayer JE Jr (2009) Analysis of the US food and drug administration manufacturer and user facility device experience database for adverse events involving Amplatzer septal occluder devices and comparison with the Society of Thoracic Surgery congenital cardiac surgery database. J Thorac Cardiovasc Surg 137:1334–1341PubMedCrossRef DiBardino DJ, McElhinney DB, Kaza AK, Mayer JE Jr (2009) Analysis of the US food and drug administration manufacturer and user facility device experience database for adverse events involving Amplatzer septal occluder devices and comparison with the Society of Thoracic Surgery congenital cardiac surgery database. J Thorac Cardiovasc Surg 137:1334–1341PubMedCrossRef
5.
Zurück zum Zitat Divekar A, Gaamangwe T, Shaikh N, Raabe M, Ducas J (2005) Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder. J Am Coll Cardiol 45:1213–1218PubMedCrossRef Divekar A, Gaamangwe T, Shaikh N, Raabe M, Ducas J (2005) Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder. J Am Coll Cardiol 45:1213–1218PubMedCrossRef
6.
Zurück zum Zitat El-Said HG, Moore JW (2009) Erosion by the Amplatzer septal occluder: experienced operator opinions at odds with manufacturer recommendations? Catheter Cardiovasc Interv 73:925–930PubMedCrossRef El-Said HG, Moore JW (2009) Erosion by the Amplatzer septal occluder: experienced operator opinions at odds with manufacturer recommendations? Catheter Cardiovasc Interv 73:925–930PubMedCrossRef
7.
Zurück zum Zitat Khodaverdian RA, Jones KW (2009) Metal allergy to Amplatzer occluder device presented as severe bronchospasm. Ann Thorac Surg 88:2021–2022PubMedCrossRef Khodaverdian RA, Jones KW (2009) Metal allergy to Amplatzer occluder device presented as severe bronchospasm. Ann Thorac Surg 88:2021–2022PubMedCrossRef
8.
Zurück zum Zitat Lai DW, Saver JL, Araujo JA, Reidl M, Tobis J (2005) Pericarditis associated with nickel hypersensitivity to the Amplatzer occluder device: a case report. Catheter Cardiovasc Interv 66:424–426PubMedCrossRef Lai DW, Saver JL, Araujo JA, Reidl M, Tobis J (2005) Pericarditis associated with nickel hypersensitivity to the Amplatzer occluder device: a case report. Catheter Cardiovasc Interv 66:424–426PubMedCrossRef
9.
Zurück zum Zitat Levi DS, Moore JW (2004) Embolization and retrieval of the Amplatzer septal occluder. Catheter Cardiovasc Interv 61:543–547PubMedCrossRef Levi DS, Moore JW (2004) Embolization and retrieval of the Amplatzer septal occluder. Catheter Cardiovasc Interv 61:543–547PubMedCrossRef
10.
Zurück zum Zitat Marini D, Boudjemline Y, Agnoletti G (2007) Closure of extracardiac Fontan fenestration by using the covered Cheatham platinum stent. Catheter Cardiovasc Interv 69:1002–1006PubMedCrossRef Marini D, Boudjemline Y, Agnoletti G (2007) Closure of extracardiac Fontan fenestration by using the covered Cheatham platinum stent. Catheter Cardiovasc Interv 69:1002–1006PubMedCrossRef
11.
Zurück zum Zitat Meraji SM, Ghaffari S, Zanjani KS (2006) Occlusion of interatrial fenestration with the Amplatzer septal occluder device: first case report from Iran. Iranian Heart J 7:56–59 Meraji SM, Ghaffari S, Zanjani KS (2006) Occlusion of interatrial fenestration with the Amplatzer septal occluder device: first case report from Iran. Iranian Heart J 7:56–59
12.
Zurück zum Zitat Mullins CE (2002) Frameless patch occlusion of atrial septal defects: frameless–less secure. Catheter Cardiovasc Interv 57:408–409PubMedCrossRef Mullins CE (2002) Frameless patch occlusion of atrial septal defects: frameless–less secure. Catheter Cardiovasc Interv 57:408–409PubMedCrossRef
13.
Zurück zum Zitat Rezaian GR, Amirghofran AA, Afifi S, Moaref AR, Rezaian S (2011) Nitinol wire mesh fracture and traumatic left atrial thrombus in a patient with atrial septal defect amplatzer occluder. J Card Surg 26:41–43PubMedCrossRef Rezaian GR, Amirghofran AA, Afifi S, Moaref AR, Rezaian S (2011) Nitinol wire mesh fracture and traumatic left atrial thrombus in a patient with atrial septal defect amplatzer occluder. J Card Surg 26:41–43PubMedCrossRef
14.
Zurück zum Zitat Sideris EB, Moulopoulos SD (2004) Transcatheter patch occlusion of heart defects. Catheter Cardiovasc Interv 61:150–151PubMedCrossRef Sideris EB, Moulopoulos SD (2004) Transcatheter patch occlusion of heart defects. Catheter Cardiovasc Interv 61:150–151PubMedCrossRef
15.
Zurück zum Zitat Sideris EB, Kaneva A, Sideris SE, Moulopoulos SD (2000) Transcatheter atrial septal defect occlusion in piglets by balloon detachable devices. Catheter Cardiovasc Interv 51:529–534PubMedCrossRef Sideris EB, Kaneva A, Sideris SE, Moulopoulos SD (2000) Transcatheter atrial septal defect occlusion in piglets by balloon detachable devices. Catheter Cardiovasc Interv 51:529–534PubMedCrossRef
16.
Zurück zum Zitat Sideris EB, Toumanides S, Macuil B, Gutierrez-Leonard H, Poursanov M, Sokolov A, Moulopoulos SD (2002) Transcatheter patch correction of secundum atrial septal defects. Am J Cardiol 89:1082–1086PubMedCrossRef Sideris EB, Toumanides S, Macuil B, Gutierrez-Leonard H, Poursanov M, Sokolov A, Moulopoulos SD (2002) Transcatheter patch correction of secundum atrial septal defects. Am J Cardiol 89:1082–1086PubMedCrossRef
17.
Zurück zum Zitat Sideris EB, Sideris CE, Stamatelopoulos SF, Moulopoulos SD (2002) Transcatheter patch occlusion of experimental atrial septal defects. Catheter Cardiovasc Interv 57:404–407PubMedCrossRef Sideris EB, Sideris CE, Stamatelopoulos SF, Moulopoulos SD (2002) Transcatheter patch occlusion of experimental atrial septal defects. Catheter Cardiovasc Interv 57:404–407PubMedCrossRef
18.
Zurück zum Zitat Sideris E, Chamie F, Haddad G, Calachanis M, Toumanides S (2008) Transcatheter patch correction of nonsecundum atrial septal defects: patient selection and clinical results. Cardiol Young 18:1–106 Sideris E, Chamie F, Haddad G, Calachanis M, Toumanides S (2008) Transcatheter patch correction of nonsecundum atrial septal defects: patient selection and clinical results. Cardiol Young 18:1–106
19.
Zurück zum Zitat Sideris B, Sideris E, Calachanis M, Papantoniou V, Moulopoulos S (2010) The Immediate-Release Patch in the correction of experimental atrial septal defects. Catheter Cardiovasc Interv 76:572–577PubMedCrossRef Sideris B, Sideris E, Calachanis M, Papantoniou V, Moulopoulos S (2010) The Immediate-Release Patch in the correction of experimental atrial septal defects. Catheter Cardiovasc Interv 76:572–577PubMedCrossRef
20.
Zurück zum Zitat Spence MS, Qureshi SA (2005) Complications of transcatheter closure of atrial septal defects. Heart 91:1512–1514PubMedCrossRef Spence MS, Qureshi SA (2005) Complications of transcatheter closure of atrial septal defects. Heart 91:1512–1514PubMedCrossRef
21.
Zurück zum Zitat Taggart NW, Dearani JA, Hagler DJ (2011) Late erosion of an Amplatzer septal occluder device 6 years after placement. J Thorac Cardiovasc Surg 142:221–222PubMedCrossRef Taggart NW, Dearani JA, Hagler DJ (2011) Late erosion of an Amplatzer septal occluder device 6 years after placement. J Thorac Cardiovasc Surg 142:221–222PubMedCrossRef
22.
Zurück zum Zitat Tehrani RB, Rostami A, Basiri HA, Mortezaiian H (2008) Device-induced perforation of right atrium following interventional closure of atrial septal defect (ASD). J Teh Univ Heart Ctr 3:113–115 Tehrani RB, Rostami A, Basiri HA, Mortezaiian H (2008) Device-induced perforation of right atrium following interventional closure of atrial septal defect (ASD). J Teh Univ Heart Ctr 3:113–115
23.
Zurück zum Zitat Wertman B, Azarbal B, Riedl M, Tobis J (2006) Adverse events associated with nickel allergy in patients undergoing percutaneous atrial septal defect or patent foramen ovale closure. J Am Coll Cardiol 47:1226–1227PubMedCrossRef Wertman B, Azarbal B, Riedl M, Tobis J (2006) Adverse events associated with nickel allergy in patients undergoing percutaneous atrial septal defect or patent foramen ovale closure. J Am Coll Cardiol 47:1226–1227PubMedCrossRef
24.
Zurück zum Zitat Wilson WM, Goh TH, Oqueli E, Willis Y, Chan C, Skillington P, Grigg LE (2010) Aorto-left atrial fistula post-percutaneous device ASD closure. Heart Lung Circ 19:53–55PubMedCrossRef Wilson WM, Goh TH, Oqueli E, Willis Y, Chan C, Skillington P, Grigg LE (2010) Aorto-left atrial fistula post-percutaneous device ASD closure. Heart Lung Circ 19:53–55PubMedCrossRef
25.
Zurück zum Zitat Zeinaloo A, Meraji SM, Zanjani KS, Mirzaaghayan MR (2008) Device occlusion versus surgery for closure of congenital heart defects: cost issues in Iran. J Teh Univ Heart Ctr 3:141–144 Zeinaloo A, Meraji SM, Zanjani KS, Mirzaaghayan MR (2008) Device occlusion versus surgery for closure of congenital heart defects: cost issues in Iran. J Teh Univ Heart Ctr 3:141–144
26.
Zurück zum Zitat Zeinaloo A, Macuil B, Zanjani KS, Sideris E (2011) Transcatheter patch occlusion of ventricular septal defect in Down syndrome. Am J Cardiol 107:1838–1840PubMedCrossRef Zeinaloo A, Macuil B, Zanjani KS, Sideris E (2011) Transcatheter patch occlusion of ventricular septal defect in Down syndrome. Am J Cardiol 107:1838–1840PubMedCrossRef
Metadaten
Titel
Closure of Interatrial Defects by Immediate-Release Patch
verfasst von
Aliakbar Zeinaloo
Keyhan Sayadpour Zanjani
Bahman Rastkar
Alimohammad Hajizeinali
Bahram Sohrabi
Mahmoud Samadi
Eleftherios B. Sideris
Publikationsdatum
01.12.2012
Verlag
Springer-Verlag
Erschienen in
Pediatric Cardiology / Ausgabe 8/2012
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-012-0284-x

Weitere Artikel der Ausgabe 8/2012

Pediatric Cardiology 8/2012 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.