Abstract

Purpose

To compare the clinical and radiological outcomes of posterior atlantoaxial fixation and fusion using C1 lateral mass–C2 pedicle screws (screw-rod constructs, SRC) with C1–C2 transarticular screws (TAS).

Methods

A retrospective review was conducted of 105 patients with atlantoaxial instability who underwent posterior C1–C2 fixation and fusion by SRC group (60 pt) and TAS group (45 pt). The follow-up period was minimum 2 years. Clinical outcomes measurements included the Numeric Rating Scale (NRS) for pain assessment, the Neck Disability Index (NDI), the Japanese Orthopedic Association (JOA) score and the American Spinal Injury Association (ASIA) impairment scale for the functional and neurological outcomes that were assessed. Radiological outcomes were assessed by evaluating the fusion rate and proper screws position. Both outcomes were evaluated in the early postoperative period, 3, 6, 12 and 24 months after surgery. Operative time, estimated blood loss, complications and length of stay were also reviewed.

Results

The majority of cases were caused by trauma and presented with axial neck pain. The improvement of NRS, NDI, JOA score and ASIA impairment scale were not different between the two groups. Proper screw position and fusion rate were also observed similarly between the two groups. Estimated blood loss was lesser and operative time was shorter in TAS group than SRC group (p = 0.047, p = 0.001, respectively). Operative complications and the length of hospital stay were also not different between the two groups.

Conclusion

Both SRC and TAS produced excellent outcomes for atlantoaxial stabilization. But the volume of bleeding and operation time tended to be better in TAS group compared to SRC group.
Literatur
1.
Zurück zum Zitat Gallie WE (1939) Fractures and dislocation of the upper cervical spine. Am J Surg 46:495–499CrossRef Gallie WE (1939) Fractures and dislocation of the upper cervical spine. Am J Surg 46:495–499CrossRef
2.
Zurück zum Zitat Brooks AL, Jenkins EB (1978) Atlantoaxial arthrodesis by the wedge compression method. J Bone Jt Surg Am 60(3):279–284CrossRef Brooks AL, Jenkins EB (1978) Atlantoaxial arthrodesis by the wedge compression method. J Bone Jt Surg Am 60(3):279–284CrossRef
3.
Zurück zum Zitat Magerl F, Seemann P (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine I. Springer, New York, pp 322–327CrossRef Magerl F, Seemann P (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine I. Springer, New York, pp 322–327CrossRef
4.
Zurück zum Zitat Hanson PB, Montesano PX, Sharkey NA, Rauschning W (1991) Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability. Spine (Phila Pa 1976) 16(10):1141–1145CrossRef Hanson PB, Montesano PX, Sharkey NA, Rauschning W (1991) Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability. Spine (Phila Pa 1976) 16(10):1141–1145CrossRef
5.
Zurück zum Zitat Finn MA, Apfelbaum RI (2010) Atlantoaxial transarticular screw fixation: update on technique and outcome in 269 patients. Neurosurgery 66(suppl3):184–192CrossRefPubMed Finn MA, Apfelbaum RI (2010) Atlantoaxial transarticular screw fixation: update on technique and outcome in 269 patients. Neurosurgery 66(suppl3):184–192CrossRefPubMed
6.
Zurück zum Zitat Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wein) 129:47–53CrossRef Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wein) 129:47–53CrossRef
7.
Zurück zum Zitat Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471CrossRef Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471CrossRef
8.
Zurück zum Zitat Dickman CA, Sonntag VK (1998) Posterior C1–C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery 43(2):275–280CrossRefPubMed Dickman CA, Sonntag VK (1998) Posterior C1–C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery 43(2):275–280CrossRefPubMed
9.
Zurück zum Zitat Xie Y, Li Z, Tang H (2009) Posterior C1 lateral mass and C2 pedicle. Screw internal fixation for atlantoaxial instability. J Clin Neurosci 16:1592–1594CrossRefPubMed Xie Y, Li Z, Tang H (2009) Posterior C1 lateral mass and C2 pedicle. Screw internal fixation for atlantoaxial instability. J Clin Neurosci 16:1592–1594CrossRefPubMed
10.
Zurück zum Zitat El Masry MA, El Assuity WI, Sadek FZ (2007) Two methods of atlantoaxial stabilisation for atlantoaxial instability. Acta Orthop Belg 73:741–746PubMed El Masry MA, El Assuity WI, Sadek FZ (2007) Two methods of atlantoaxial stabilisation for atlantoaxial instability. Acta Orthop Belg 73:741–746PubMed
11.
Zurück zum Zitat Lee SH, Kim ES, Sung JK (2010) Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1–C2 transarticular screw fixation or C1 lateral mass–C2 pedicle screw fixation. J Clin Neurosci 17:886–892CrossRefPubMed Lee SH, Kim ES, Sung JK (2010) Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1–C2 transarticular screw fixation or C1 lateral mass–C2 pedicle screw fixation. J Clin Neurosci 17:886–892CrossRefPubMed
12.
Zurück zum Zitat Coyne JJ, Fehlings MG, Wallace MC, Bernstein M, Tator CH (1995) C1–C2 posterior cervical fusion: long term evaluation of results and efficacy. Neurosurgery 37:688–692 (discussion 692–693) CrossRefPubMed Coyne JJ, Fehlings MG, Wallace MC, Bernstein M, Tator CH (1995) C1–C2 posterior cervical fusion: long term evaluation of results and efficacy. Neurosurgery 37:688–692 (discussion 692–693) CrossRefPubMed
13.
Zurück zum Zitat Farey ID, Nadkarni S, Smith N (1999) Modified Gallie technique versus transarticular screw fixation in C1–C2 fusion. Clin Orthop Relat Res 359:126–135CrossRef Farey ID, Nadkarni S, Smith N (1999) Modified Gallie technique versus transarticular screw fixation in C1–C2 fusion. Clin Orthop Relat Res 359:126–135CrossRef
14.
Zurück zum Zitat Fraser AB, Sen C, Casden AM, Catalano PJ, Post KD (1994) Cervical transdural intramedullary migration of a sublaminar wire. A complication of cervical fixation. Spine (Phila Pa 1976) 19(4):456–459CrossRef Fraser AB, Sen C, Casden AM, Catalano PJ, Post KD (1994) Cervical transdural intramedullary migration of a sublaminar wire. A complication of cervical fixation. Spine (Phila Pa 1976) 19(4):456–459CrossRef
15.
Zurück zum Zitat Xu T, Guo Q, Liu Q, Zhang P, Lu M, Lu X, Chen F, Guo X, Ni B (2016) Biomecanical evaluation of a novel integrated C1 laminar hook combined with C1–C2 transarticular screws for atlantoaxial fusion: an invitro human cadaveric study. World Neurosurg 92:133–139CrossRefPubMed Xu T, Guo Q, Liu Q, Zhang P, Lu M, Lu X, Chen F, Guo X, Ni B (2016) Biomecanical evaluation of a novel integrated C1 laminar hook combined with C1–C2 transarticular screws for atlantoaxial fusion: an invitro human cadaveric study. World Neurosurg 92:133–139CrossRefPubMed
16.
Zurück zum Zitat Aryan HE, Newman CB, Nottmeier EW (2008) Stabilization of the atlantoaxial complex via C–1 lateral mass and C–2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques. J Neurosurg Spine 8:222–229CrossRefPubMed Aryan HE, Newman CB, Nottmeier EW (2008) Stabilization of the atlantoaxial complex via C–1 lateral mass and C–2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques. J Neurosurg Spine 8:222–229CrossRefPubMed
17.
Zurück zum Zitat Fiore AJ, Haid RW, Rodts GE (2002) Alantal lateral mass screws for posterior spinal reconstruction technical note and case series. Neurosurg Focus 12:E5CrossRefPubMed Fiore AJ, Haid RW, Rodts GE (2002) Alantal lateral mass screws for posterior spinal reconstruction technical note and case series. Neurosurg Focus 12:E5CrossRefPubMed
18.
Zurück zum Zitat Stulik J, Vyskocil T, Sebesta P (2007) Atlantoaxial fixation using the polyaxial screw-rod system. Eur Spine J 16:479–484CrossRefPubMed Stulik J, Vyskocil T, Sebesta P (2007) Atlantoaxial fixation using the polyaxial screw-rod system. Eur Spine J 16:479–484CrossRefPubMed
19.
Zurück zum Zitat Yan L, He B, Liu T, Yang L, Hao D (2016) A prospective, double-blind, randomized controlled trial of treatment of atlantoaxial instability with C1 posterior arch >4 mm by comparing C1 pedicle with lateral mass screws fixation. BMC Musculoskelet Disord 17:164CrossRefPubMedPubMedCentral Yan L, He B, Liu T, Yang L, Hao D (2016) A prospective, double-blind, randomized controlled trial of treatment of atlantoaxial instability with C1 posterior arch >4 mm by comparing C1 pedicle with lateral mass screws fixation. BMC Musculoskelet Disord 17:164CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Kim JY, Oh CH, Yoon SH (2014) Comparison of outcomes after atlantoaxial fusion with transarticular screws and screw-rod constructs. J Korean Neurosurg 55(5):255–260CrossRef Kim JY, Oh CH, Yoon SH (2014) Comparison of outcomes after atlantoaxial fusion with transarticular screws and screw-rod constructs. J Korean Neurosurg 55(5):255–260CrossRef
21.
Zurück zum Zitat Elliott RE, Tanweer O, Boah A, Morsi A, Ma T, Frempong-Boadu A (2014) Outcome comparison of atlantoaxial fusion with transarticular screws and screw-rod constructs: meta-analysis and review of literature. J Spinal Disord Technol 27(1):11–28CrossRef Elliott RE, Tanweer O, Boah A, Morsi A, Ma T, Frempong-Boadu A (2014) Outcome comparison of atlantoaxial fusion with transarticular screws and screw-rod constructs: meta-analysis and review of literature. J Spinal Disord Technol 27(1):11–28CrossRef
22.
Zurück zum Zitat Hott JS, Lynch JJ, Chamberlain RH (2005) Biomechanical comparison of C1–2 posterior fixation techniques. J Neurosurg Spine 2:175–181CrossRefPubMed Hott JS, Lynch JJ, Chamberlain RH (2005) Biomechanical comparison of C1–2 posterior fixation techniques. J Neurosurg Spine 2:175–181CrossRefPubMed
23.
Zurück zum Zitat Resnick DK, Lapsiwala S, Trost GR (2002) Anatomic suitability of the C1–C2 complex for pedicle screw fixation. Spine (Phila Pa 1976) 27:1494–1498CrossRef Resnick DK, Lapsiwala S, Trost GR (2002) Anatomic suitability of the C1–C2 complex for pedicle screw fixation. Spine (Phila Pa 1976) 27:1494–1498CrossRef
24.
Zurück zum Zitat Sivaraju L, Mani S, Prabhu K, Daniel RT, Chacko AG (2016) Three-dimensional computed tomography angiographic study of the vertebral artery in patients with congenital craniovertebral junction anomalies. Eur Spine J. doi:10.1007/s00586-016-4580-7 PubMed Sivaraju L, Mani S, Prabhu K, Daniel RT, Chacko AG (2016) Three-dimensional computed tomography angiographic study of the vertebral artery in patients with congenital craniovertebral junction anomalies. Eur Spine J. doi:10.​1007/​s00586-016-4580-7 PubMed
25.
Zurück zum Zitat Yoshida M, Neo M, Fujibayashi S et al (2006) Comparison of the anatomical risk for vertebral artery injury associated with the C2 pedicle screw and atlantoaxial transarticular screw. Spine (Phila Pa 1976) 31:E513–E517CrossRef Yoshida M, Neo M, Fujibayashi S et al (2006) Comparison of the anatomical risk for vertebral artery injury associated with the C2 pedicle screw and atlantoaxial transarticular screw. Spine (Phila Pa 1976) 31:E513–E517CrossRef
Metadaten
Titel
Comparison of outcomes after atlantoaxial fusion with C1 lateral mass–C2 pedicle screws and C1–C2 transarticular screws
verfasst von
Panupol Rajinda
Sirisomboon Towiwat
Piyawat Chirappapha
Publikationsdatum
22.10.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 4/2017
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-016-4829-1

Weitere Artikel der Ausgabe 4/2017

European Spine Journal 4/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.