Skip to main content
Erschienen in: Lasers in Medical Science 2/2009

01.03.2009 | Original article

Comparison of temperature increase in in vitro human tooth pulp by different light sources in the dental whitening process

verfasst von: Daniela Soares Coutinho, Landulfo Silveira Jr., Renata Amadei Nicolau, Fátima Zanin, Aldo Brugnera Jr.

Erschienen in: Lasers in Medical Science | Ausgabe 2/2009

Einloggen, um Zugang zu erhalten

Abstract

This work evaluated the increase in dental pulp temperature caused by different light sources, used in the dental whitening process, following the irradiation protocol from the light manufacturer. Human incisor, canine and premolar teeth were used. A whitening gel made of hydrogen peroxide 35% v/v and a condenser agent were applied to each tooth, on the vestibular surface, and was activated by five different light sources: photo-polymerizer with blue bandpass filtered halogen lamp (HL) (600 mW, λ = 430–480 nm), blue light emitting diode (LED) (BL) (1 W, λ = 470 nm), blue LED associated with infrared diode laser (BL+IL) (120 mW, λ = 795 nm), green LED (GL) (600 mW, λ = 530 nm) and green LED associated with infrared diode laser (GL+IL) (120 mW, λ = 795 nm), with the equipment turned on, an exposure time of 1 min, and resting time of 30 s, repeated three times. The temperature was measured at the beginning and ending of exposure by a digital thermometer (type K thermocouple), placed inside the dental pulp chamber. Analyzing the mean temperature variation that occurred along the irradiation time, we found that the BL and BL+IL group presented the highest temperature variations, mainly in the incisor tooth. The GL and GL+IL presented the lowest temperature increase. The maximum temperature variation reached was 5.5°C for the BL+IL in the incisor tooth. The HL presented a smaller temperature variation than the BL did, but it had a residual temperature when the light was off. The GL and GL+IL promoted a non-significant temperature increase, as low as 1°C, even with total power equal to the that of the HL.
Literatur
1.
Zurück zum Zitat Carrasco LD, Guerisoli DM, Rocha MJ, Pécora JD, Froner IC (2007) Efficacy of intracoronal bleaching techniques with different light activation sources. Int Endod J 40:204–208PubMedCrossRef Carrasco LD, Guerisoli DM, Rocha MJ, Pécora JD, Froner IC (2007) Efficacy of intracoronal bleaching techniques with different light activation sources. Int Endod J 40:204–208PubMedCrossRef
2.
Zurück zum Zitat Carrasco LD, Guerisoli DM, Pécora JD, Froner IC (2007) Evaluation of dentin permeability after light activated internal dental bleaching. Dent Traumatol 23:30–34PubMedCrossRef Carrasco LD, Guerisoli DM, Pécora JD, Froner IC (2007) Evaluation of dentin permeability after light activated internal dental bleaching. Dent Traumatol 23:30–34PubMedCrossRef
3.
Zurück zum Zitat Haywood VB, Heymann HO (1989) Nightguard vital bleaching. Quintessence Int 20:173–176PubMed Haywood VB, Heymann HO (1989) Nightguard vital bleaching. Quintessence Int 20:173–176PubMed
4.
Zurück zum Zitat Dostalova T, Jelinkova H, Housova D, Sulc J, Nemec M, Miyagi M, Brugnera A Jr, Zanin F (2004) Diode laser-activated bleaching. Braz Dent J 15:SI3–SI8PubMedCrossRef Dostalova T, Jelinkova H, Housova D, Sulc J, Nemec M, Miyagi M, Brugnera A Jr, Zanin F (2004) Diode laser-activated bleaching. Braz Dent J 15:SI3–SI8PubMedCrossRef
5.
Zurück zum Zitat Sun G (2000) The role of lasers in cosmetic dentistry. Dent Clin North Am 44:831–850PubMed Sun G (2000) The role of lasers in cosmetic dentistry. Dent Clin North Am 44:831–850PubMed
6.
Zurück zum Zitat Torres CRG, Borges AB, Kubo CH, Gonçalves SEP Araújo RM, Celaschi S, Giorgano C, Arcas F (2004) Clareamento Dental com Fontes Híbridas Led/Laser (ed). Taubaté, Evidência Visual, p 140 Torres CRG, Borges AB, Kubo CH, Gonçalves SEP Araújo RM, Celaschi S, Giorgano C, Arcas F (2004) Clareamento Dental com Fontes Híbridas Led/Laser (ed). Taubaté, Evidência Visual, p 140
7.
Zurück zum Zitat Reyto R (1998) Laser tooth whitening. Dent Clin North Am 42:755–762PubMed Reyto R (1998) Laser tooth whitening. Dent Clin North Am 42:755–762PubMed
8.
Zurück zum Zitat Christensen GJ (2002) The tooth-whitening revolution. J Am Dent Assoc 133:1277–1279PubMed Christensen GJ (2002) The tooth-whitening revolution. J Am Dent Assoc 133:1277–1279PubMed
9.
Zurück zum Zitat Zanin F, Brugnera A Jr A (2004). Clareamento dental com luz laser (ed). Santos, São Paulo, p 103 Zanin F, Brugnera A Jr A (2004). Clareamento dental com luz laser (ed). Santos, São Paulo, p 103
10.
Zurück zum Zitat Tavares M, Stultz J, Newman M, Smith V, Kent R, Carpino E, Goodson JM (2003) Light augments tooth whitening with peroxide. J Am Dent Assoc 134:167–175PubMed Tavares M, Stultz J, Newman M, Smith V, Kent R, Carpino E, Goodson JM (2003) Light augments tooth whitening with peroxide. J Am Dent Assoc 134:167–175PubMed
12.
Zurück zum Zitat Kurachi C, Magalhães DV, Eduardo CP, Bagnato VS (1998) Análise Térmica para um Pré-Molar Humano Exposto à Luz Laser. Rev Fis Apl Instrum 13:5–8 Kurachi C, Magalhães DV, Eduardo CP, Bagnato VS (1998) Análise Térmica para um Pré-Molar Humano Exposto à Luz Laser. Rev Fis Apl Instrum 13:5–8
13.
Zurück zum Zitat Goodis HE, White JM, Andrews J, Watanabe LG (1989) Measurements of temperature generated by visible-light-cure lamps in an in vitro model. Dent Mater 5:230–234PubMedCrossRef Goodis HE, White JM, Andrews J, Watanabe LG (1989) Measurements of temperature generated by visible-light-cure lamps in an in vitro model. Dent Mater 5:230–234PubMedCrossRef
14.
Zurück zum Zitat Powell GL, Anderson JR, Blankenau RJ (1999) Laser and curing light induced in vitro pulpal temperature changes. J Clin Laser Med Surg 17:3–5PubMed Powell GL, Anderson JR, Blankenau RJ (1999) Laser and curing light induced in vitro pulpal temperature changes. J Clin Laser Med Surg 17:3–5PubMed
15.
16.
Zurück zum Zitat Baik JW, Rueggeberg FA, Liewehr FR (2001) Effect of light-enhanced bleaching on in vitro surface and intrapulpal temperature rise. J Esthet Restor Dent 13:370–378PubMedCrossRef Baik JW, Rueggeberg FA, Liewehr FR (2001) Effect of light-enhanced bleaching on in vitro surface and intrapulpal temperature rise. J Esthet Restor Dent 13:370–378PubMedCrossRef
17.
Zurück zum Zitat Gutknecht N, Franzen R, Meister J, Vanweersch L, Mir M (2005) Temperature evolution on human teeth root surface after diode laser assisted endodontic treatment. Lasers Med Sci 20:99–103PubMedCrossRef Gutknecht N, Franzen R, Meister J, Vanweersch L, Mir M (2005) Temperature evolution on human teeth root surface after diode laser assisted endodontic treatment. Lasers Med Sci 20:99–103PubMedCrossRef
18.
Zurück zum Zitat Wetter NU, Barroso MC, Pelino JE (2004) Dental bleaching efficacy with diode laser and LED irradiation: an in vitro study. Lasers Surg Med 35:254–258PubMedCrossRef Wetter NU, Barroso MC, Pelino JE (2004) Dental bleaching efficacy with diode laser and LED irradiation: an in vitro study. Lasers Surg Med 35:254–258PubMedCrossRef
19.
Zurück zum Zitat Mills RW, Jandt KD, Ashworth SH (1999) Dental composite depth of cure with halogen and blue light emitting diode technology. Br Dent J 186:388–391PubMedCrossRef Mills RW, Jandt KD, Ashworth SH (1999) Dental composite depth of cure with halogen and blue light emitting diode technology. Br Dent J 186:388–391PubMedCrossRef
20.
Zurück zum Zitat Cefaly DFG, Ferrarezi GAO, Tapety CMC, Lauris JRP, Navarro MFL (2005) Microhardness of resin-based materials polymerized with LED and halogen curing units. Braz Dent J 16:98–102PubMedCrossRef Cefaly DFG, Ferrarezi GAO, Tapety CMC, Lauris JRP, Navarro MFL (2005) Microhardness of resin-based materials polymerized with LED and halogen curing units. Braz Dent J 16:98–102PubMedCrossRef
21.
Zurück zum Zitat Calmon WJ, Brugnera A Jr, Munin E, Lobo PDC, Zanin F, Pécora JD, Barbin EL, Espano JCE (2004) Estudo do Aumento de Temperatura Intra-Pulpar Gerado pelo Clareamento Dental. Rev Gaúcha Odont 52:19–24 Calmon WJ, Brugnera A Jr, Munin E, Lobo PDC, Zanin F, Pécora JD, Barbin EL, Espano JCE (2004) Estudo do Aumento de Temperatura Intra-Pulpar Gerado pelo Clareamento Dental. Rev Gaúcha Odont 52:19–24
22.
Zurück zum Zitat Sulieman M, Addy M, Rees JS (2005) Surface and intra-pulpal temperature rises during tooth bleaching: an in vitro study. Br Dent J 199:37–40PubMedCrossRef Sulieman M, Addy M, Rees JS (2005) Surface and intra-pulpal temperature rises during tooth bleaching: an in vitro study. Br Dent J 199:37–40PubMedCrossRef
23.
Zurück zum Zitat Zhang C, Wang X, Kinoshita JI, Zhao B, Toko T, Kimura Y, Matsumoto K (2007) Effects of KTP irradiation laser irradiation, diode laser, and LED on tooth bleaching: a comparative study. Photomed Laser Surg 25:91–95PubMedCrossRef Zhang C, Wang X, Kinoshita JI, Zhao B, Toko T, Kimura Y, Matsumoto K (2007) Effects of KTP irradiation laser irradiation, diode laser, and LED on tooth bleaching: a comparative study. Photomed Laser Surg 25:91–95PubMedCrossRef
24.
Zurück zum Zitat Luk K, Tam L, Hubert M (2004) Effect of light energy on peroxide tooth bleaching. Am Dent Assoc 135:194–201 Luk K, Tam L, Hubert M (2004) Effect of light energy on peroxide tooth bleaching. Am Dent Assoc 135:194–201
25.
Zurück zum Zitat Sulieman M, Rees JS, Addy M (2006) Surface and pulp chamber temperature rises during tooth bleaching using a diode laser: a study in vitro. Br Dent J 200:631–634PubMedCrossRef Sulieman M, Rees JS, Addy M (2006) Surface and pulp chamber temperature rises during tooth bleaching using a diode laser: a study in vitro. Br Dent J 200:631–634PubMedCrossRef
26.
Zurück zum Zitat Eldeniz AU, Usumez A, Usumez S, Ozturk N (2005) Pulpal temperature rise during light-activated bleaching. J Biomed Mater Res B Appl Biomater 72:254–259PubMed Eldeniz AU, Usumez A, Usumez S, Ozturk N (2005) Pulpal temperature rise during light-activated bleaching. J Biomed Mater Res B Appl Biomater 72:254–259PubMed
27.
Zurück zum Zitat Coutinho DS, Silveira L Jr (2006) Comparação dos Coeficientes de Absorção da Luz Emitida por um LED Verde e um LED Azul em um Espessante na Cor Vermelha. Rev Assoc Bras Odontol 2:12–13 Coutinho DS, Silveira L Jr (2006) Comparação dos Coeficientes de Absorção da Luz Emitida por um LED Verde e um LED Azul em um Espessante na Cor Vermelha. Rev Assoc Bras Odontol 2:12–13
Metadaten
Titel
Comparison of temperature increase in in vitro human tooth pulp by different light sources in the dental whitening process
verfasst von
Daniela Soares Coutinho
Landulfo Silveira Jr.
Renata Amadei Nicolau
Fátima Zanin
Aldo Brugnera Jr.
Publikationsdatum
01.03.2009
Verlag
Springer-Verlag
Erschienen in
Lasers in Medical Science / Ausgabe 2/2009
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-008-0546-2

Weitere Artikel der Ausgabe 2/2009

Lasers in Medical Science 2/2009 Zur Ausgabe