Skip to main content
Erschienen in: European Spine Journal 6/2006

01.06.2006 | Original Article

Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation

verfasst von: D. Briem, W. Linhart, W. Lehmann, P. G. Begemann, G. Adam, U. Schumacher, D. M. Cullinane, J. M. Rueger, J. Windolf

Erschienen in: European Spine Journal | Ausgabe 6/2006

Einloggen, um Zugang zu erhalten

Abstract

Currently there are few data available regarding the application and efficacy of computer-assisted procedures in the sacral spine. In order to optimize and standardize this procedure, a controlled experimental investigation has been performed. The aim of the study is to systematically assess the efficacy of a novel three-dimensional image intensifier used for navigated transiliac screw insertion into the first sacral vertebra. Screws were inserted iliosacrally into the first sacral vertebra of preserved human cadaver specimens. The instrument navigated procedure was performed with the “Siremobil Iso-C3D ” (Siemens Medical Solutions) and the “Navigation System” by Stryker. The accuracy and quality of the imaging procedure as well as the fluoroscopic exposure times were measured. These results were compared to three control groups (CT-based navigation, C-arm navigation, and fluoroscopic guidance). In each group a total amount of 20 screws was implanted. Screw position was postoperatively assessed by Iso-C3D or CT-scan. The navigated procedure using the Iso-C3D provided good feasibility characteristics without requiring a specific matching process. It revealed the shortest procedure time of all navigated procedures and significantly decreased fluoroscopic time compared to C-arm navigation and fluoroscopic guidance. Furthermore, Iso-C3D navigation showed no screw malposition and was in this regard superior to C-arm navigated and fluoroscopic guided procedures. The quality of imaging was sufficient for accurate placement, but did not share the high-resolution level of CT-based navigation. These findings indicate that application of the Iso-C3D for navigated transiliac screw insertion into S1 can be recommended as a feasible and safe technique, enabling the surgeon to reduce procedure and fluoroscopic time. Further progress in improving the quality of the Iso-C3D image should be attempted.
Literatur
1.
Zurück zum Zitat Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25(5):606–614PubMed Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25(5):606–614PubMed
2.
Zurück zum Zitat Arand M, Kinzl L, Gebhard F (2002) Sources of error and risks in CT based navigation. Orthopäde 31(4):378–384PubMed Arand M, Kinzl L, Gebhard F (2002) Sources of error and risks in CT based navigation. Orthopäde 31(4):378–384PubMed
3.
Zurück zum Zitat Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop 422:201–207PubMed Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop 422:201–207PubMed
4.
Zurück zum Zitat Berlemann U, Monin D, Arm E, Nolte LP, Ozdoba C (1997) Planning and insertion of pedicle screws with computer assistance. J Spinal Disord 10(2):117–124PubMed Berlemann U, Monin D, Arm E, Nolte LP, Ozdoba C (1997) Planning and insertion of pedicle screws with computer assistance. J Spinal Disord 10(2):117–124PubMed
5.
Zurück zum Zitat El Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T, Klose KJ, Wagner HJ (2001) Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology 221(3):843–849PubMed El Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T, Klose KJ, Wagner HJ (2001) Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology 221(3):843–849PubMed
6.
Zurück zum Zitat Euler E, Heining S, Riquarts C, Mutschler W (2003) C-arm-based three-dimensional navigation: a preliminary feasibility study. Comput Aided Surg 8(1):35–41PubMed Euler E, Heining S, Riquarts C, Mutschler W (2003) C-arm-based three-dimensional navigation: a preliminary feasibility study. Comput Aided Surg 8(1):35–41PubMed
7.
Zurück zum Zitat Gebhard F, Weidner A, Liener UC, Stockle U, Arand M (2004) Navigation at the spine. Injury 35(Suppl 1):S35–S45 Gebhard F, Weidner A, Liener UC, Stockle U, Arand M (2004) Navigation at the spine. Injury 35(Suppl 1):S35–S45
8.
Zurück zum Zitat Giannikas KA, Khan AM, Karski MT, Maxwell HA (2004) Sacroiliac joint fusion for chronic pain: a simple technique avoiding the use of metalwork. Eur Spine J 13(3):253–256PubMed Giannikas KA, Khan AM, Karski MT, Maxwell HA (2004) Sacroiliac joint fusion for chronic pain: a simple technique avoiding the use of metalwork. Eur Spine J 13(3):253–256PubMed
9.
Zurück zum Zitat Grützner PA, Rose E, Vock B, Holz F, Nolte LP, Wentzensen A (2002) Computer-assisted screw osteosynthesis of the posterior pelvic ring. Initial experiences with an image reconstruction based optoelectronic navigation system. Unfallchirurg 105(3):254–260PubMed Grützner PA, Rose E, Vock B, Holz F, Nolte LP, Wentzensen A (2002) Computer-assisted screw osteosynthesis of the posterior pelvic ring. Initial experiences with an image reconstruction based optoelectronic navigation system. Unfallchirurg 105(3):254–260PubMed
10.
Zurück zum Zitat Kotsianos D, Rock C, Wirth S, Linsenmaier U, Brandl R, Fischer T, Euler E, Mutschler W, Pfeifer KJ, Reiser M (2002) Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): comparison with plain films and spiral CT. Rofo 174(1):82–87PubMed Kotsianos D, Rock C, Wirth S, Linsenmaier U, Brandl R, Fischer T, Euler E, Mutschler W, Pfeifer KJ, Reiser M (2002) Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): comparison with plain films and spiral CT. Rofo 174(1):82–87PubMed
11.
Zurück zum Zitat Kotsianos D, Wirth S, Fischer T, Euler E, Rock C, Linsenmaier U, Pfeifer KJ, Reiser M (2004) 3D imaging with an isocentric mobile C-arm. Comparison of image quality with spiral CT. Eur Radiol 14(9):1590–1595PubMed Kotsianos D, Wirth S, Fischer T, Euler E, Rock C, Linsenmaier U, Pfeifer KJ, Reiser M (2004) 3D imaging with an isocentric mobile C-arm. Comparison of image quality with spiral CT. Eur Radiol 14(9):1590–1595PubMed
12.
Zurück zum Zitat Krivonos O, Gebhard F, Keppler P, Kinzl L, Hesser J, Manner R (2001) Computer assisted treatment of pelvis fractures. Stud Health Technol Inform 81:242–246PubMed Krivonos O, Gebhard F, Keppler P, Kinzl L, Hesser J, Manner R (2001) Computer assisted treatment of pelvis fractures. Stud Health Technol Inform 81:242–246PubMed
13.
Zurück zum Zitat Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9(3):235–240PubMed Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9(3):235–240PubMed
14.
Zurück zum Zitat Laine T, Makitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6(6):402–405PubMed Laine T, Makitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6(6):402–405PubMed
15.
Zurück zum Zitat Langlotz F, Nolte L (2004) Technical approaches to computer-assisted orthopedic surgery. Eur J Trauma 30(1):1–11 Langlotz F, Nolte L (2004) Technical approaches to computer-assisted orthopedic surgery. Eur J Trauma 30(1):1–11
16.
Zurück zum Zitat Linsenmaier U, Rock C, Euler E, Wirth S, Brandl R, Kotsianos D, Mutschler W, Pfeifer KJ (2002) Three-dimensional CT with a modified C-arm image intensifier: feasibility. Radiology 224(1):286–292PubMed Linsenmaier U, Rock C, Euler E, Wirth S, Brandl R, Kotsianos D, Mutschler W, Pfeifer KJ (2002) Three-dimensional CT with a modified C-arm image intensifier: feasibility. Radiology 224(1):286–292PubMed
17.
Zurück zum Zitat Matta JM (1996) Regarding safe and effective placement of ileosacral screws. J Orthop Trauma 10(7):514PubMed Matta JM (1996) Regarding safe and effective placement of ileosacral screws. J Orthop Trauma 10(7):514PubMed
18.
Zurück zum Zitat Matta JM, Tornetta P III (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop 329:129–140PubMed Matta JM, Tornetta P III (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop 329:129–140PubMed
19.
Zurück zum Zitat Nogler M, Maurer H, Wimmer C, Gegenhuber C, Bach C, Krismer M (2001) Knee pain caused by a fiducial marker in the medial femoral condyle: a clinical and anatomic study of 20 cases. Acta Orthop Scand 72(5):477–480PubMed Nogler M, Maurer H, Wimmer C, Gegenhuber C, Bach C, Krismer M (2001) Knee pain caused by a fiducial marker in the medial femoral condyle: a clinical and anatomic study of 20 cases. Acta Orthop Scand 72(5):477–480PubMed
20.
Zurück zum Zitat Nolte LP, Beutler T (2004) Basic principles of CAOS. Injury 35(Suppl 1):S6–S16 Nolte LP, Beutler T (2004) Basic principles of CAOS. Injury 35(Suppl 1):S6–S16
21.
Zurück zum Zitat Nolte LP, Slomczykowski MA, Berlemann U, Strauss MJ, Hofstetter R, Schlenzka D, Laine T, Lund T (2000) A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation. Eur Spine J 9(sSuppl 1):S78–S88PubMed Nolte LP, Slomczykowski MA, Berlemann U, Strauss MJ, Hofstetter R, Schlenzka D, Laine T, Lund T (2000) A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation. Eur Spine J 9(sSuppl 1):S78–S88PubMed
22.
Zurück zum Zitat Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L (1995) Computer-aided fixation of spinal implants. J Image Guid Surg 1(2):88–93PubMed Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L (1995) Computer-aided fixation of spinal implants. J Image Guid Surg 1(2):88–93PubMed
23.
Zurück zum Zitat Rock C, Kotsianos D, Linsenmaier U, Fischer T, Brandl R, Vill F, Wirth S, Kaltschmidt R, Euler E, Pfeifer KJ, Reiser M (2002) Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3 D). Rofo 174(2):170–176PubMed Rock C, Kotsianos D, Linsenmaier U, Fischer T, Brandl R, Vill F, Wirth S, Kaltschmidt R, Euler E, Pfeifer KJ, Reiser M (2002) Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3 D). Rofo 174(2):170–176PubMed
24.
Zurück zum Zitat Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207–214PubMed Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207–214PubMed
25.
Zurück zum Zitat Routt ML Jr, Simonian PT (1996) Internal fixation of pelvic ring disruptions. Injury 27(Suppl 2):B20–B30PubMed Routt ML Jr, Simonian PT (1996) Internal fixation of pelvic ring disruptions. Injury 27(Suppl 2):B20–B30PubMed
26.
Zurück zum Zitat Schep NW, Haverlag R, van Vugt AB (2004) Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma 57(6):1299–1302PubMed Schep NW, Haverlag R, van Vugt AB (2004) Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma 57(6):1299–1302PubMed
27.
Zurück zum Zitat Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9(Suppl 1):S57–S64PubMed Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9(Suppl 1):S57–S64PubMed
28.
Zurück zum Zitat Stöckle U, Krettek C, Pohlemann T, Messmer P (2004) Clinical applications—pelvis. Injury 35(Suppl 1):S46–S56 Stöckle U, Krettek C, Pohlemann T, Messmer P (2004) Clinical applications—pelvis. Injury 35(Suppl 1):S46–S56
29.
Zurück zum Zitat Tile M, Helfet DL, Kellam JF (2003) Fractures of the pelvis and acetabulum. Lippincott Williams and Wilkins, Philadelphia Tile M, Helfet DL, Kellam JF (2003) Fractures of the pelvis and acetabulum. Lippincott Williams and Wilkins, Philadelphia
30.
Zurück zum Zitat Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallee S, Chirossel JP (2001) Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy. Comput Aided Surg 6(4):204–211PubMed Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallee S, Chirossel JP (2001) Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy. Comput Aided Surg 6(4):204–211PubMed
31.
Zurück zum Zitat Tonetti J, Carrat L, Lavallee S, Pittet L, Merloz P, Chirossel JP (1998) Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop 354:103–110PubMed Tonetti J, Carrat L, Lavallee S, Pittet L, Merloz P, Chirossel JP (1998) Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop 354:103–110PubMed
32.
Zurück zum Zitat Wendl K, von Recum J, Wentzensen A, Grützner PA (2003) Iso-C3D -gestützte navigierte Implantation von Pedikelschrauben an BWS und LWS. Unfallchirurg 106(11):907–913PubMed Wendl K, von Recum J, Wentzensen A, Grützner PA (2003) Iso-C3D -gestützte navigierte Implantation von Pedikelschrauben an BWS und LWS. Unfallchirurg 106(11):907–913PubMed
33.
Zurück zum Zitat Winkler D, Vitzthum HE, Seifert V (1999) Spinal markers: a new method for increasing accuracy in spinal navigation. Comput Aided Surg 4(2):101–104PubMed Winkler D, Vitzthum HE, Seifert V (1999) Spinal markers: a new method for increasing accuracy in spinal navigation. Comput Aided Surg 4(2):101–104PubMed
Metadaten
Titel
Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation
verfasst von
D. Briem
W. Linhart
W. Lehmann
P. G. Begemann
G. Adam
U. Schumacher
D. M. Cullinane
J. M. Rueger
J. Windolf
Publikationsdatum
01.06.2006
Erschienen in
European Spine Journal / Ausgabe 6/2006
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-005-0992-5

Weitere Artikel der Ausgabe 6/2006

European Spine Journal 6/2006 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.