01.07.2016 | Systems-Level Quality Improvement

Design and Construction of a Microcontroller-Based Ventilator Synchronized with Pulse Oximeter

verfasst von: Adem Gölcük, Hakan Işık, İnan Güler

Erschienen in: Journal of Medical Systems | Ausgabe 7/2016

Einloggen, um Zugang zu erhalten

Abstract

This study aims to introduce a novel device with which mechanical ventilator and pulse oximeter work in synchronization. Serial communication technique was used to enable communication between the pulse oximeter and the ventilator. The SpO2 value and the pulse rate read on the pulse oximeter were transmitted to the mechanical ventilator through transmitter (Tx) and receiver (Rx) lines. The fuzzy-logic-based software developed for the mechanical ventilator interprets these values and calculates the percentage of oxygen (FiO2) and Positive End-Expiratory Pressure (PEEP) to be delivered to the patient. The fuzzy-logic-based software was developed to check the changing medical states of patients and to produce new results (FiO2 ve PEEP) according to each new state. FiO2 and PEEP values delivered from the ventilator to the patient can be calculated in this way without requiring any arterial blood gas analysis. Our experiments and the feedbacks from physicians show that this device makes it possible to obtain more successful results when compared to the current practices.
Literatur
1.
Zurück zum Zitat Hopper K., “Basic mechanical ventilation”, small animal critical care medicine, pages 900–904, 2009. Hopper K., “Basic mechanical ventilation”, small animal critical care medicine, pages 900–904, 2009.
2.
Zurück zum Zitat Berry DC, Seitz RS., “Educating the educator: use of pulse oximetry in athletic training”, Athl. Train. Educ. J., ISSN:1947-380X doi:10.5608/070274, 7(2):74–80, 2012. Berry DC, Seitz RS., “Educating the educator: use of pulse oximetry in athletic training”, Athl. Train. Educ. J., ISSN:1947-380X doi:10.​5608/​070274, 7(2):74–80, 2012.
3.
Zurück zum Zitat Giuliano, K.K., and Higgins, T.L., New-generation pulse oximetry in the care of critically ill patients. Am. J. Crit. Care. 14:26–39, 2005.PubMed Giuliano, K.K., and Higgins, T.L., New-generation pulse oximetry in the care of critically ill patients. Am. J. Crit. Care. 14:26–39, 2005.PubMed
4.
Zurück zum Zitat Popovich, D., Richiuso, N., and Danek, G., Pediatric health care providers' knowledge of pulse oximetry. Pediatr. Nurs. 30:14–20, 2004.PubMed Popovich, D., Richiuso, N., and Danek, G., Pediatric health care providers' knowledge of pulse oximetry. Pediatr. Nurs. 30:14–20, 2004.PubMed
5.
Zurück zum Zitat Rice, T.W., Wheeler, A.P., Bernard, G.R., Hayden, D.L., Schoenfeld, D.A., and Ware, L.B., Comparison of the SpO2/FiO2 ratio and the PaO2/FiO2 ratio in patients with acute lung injury or ARDS. Chest. 132(2):410–441, 2007.CrossRefPubMed Rice, T.W., Wheeler, A.P., Bernard, G.R., Hayden, D.L., Schoenfeld, D.A., and Ware, L.B., Comparison of the SpO2/FiO2 ratio and the PaO2/FiO2 ratio in patients with acute lung injury or ARDS. Chest. 132(2):410–441, 2007.CrossRefPubMed
6.
Zurück zum Zitat Rusch TL, Sankar R, Scharf, J.E., “Signal processing methods for pulse oximetry”, Comput. Biol. Med. vol. 26, No. 2, pp. 143–159, Printed in Great Britain (SPO2 computation), 1996. Rusch TL, Sankar R, Scharf, J.E., “Signal processing methods for pulse oximetry”, Comput. Biol. Med. vol. 26, No. 2, pp. 143–159, Printed in Great Britain (SPO2 computation), 1996.
7.
Zurück zum Zitat Hall, J.E., “Guyton and hall medical physiology”, nobel medical bookstores: ISBN: 978-975-420-956-3, Ankara, 2003. Hall, J.E., “Guyton and hall medical physiology”, nobel medical bookstores: ISBN: 978-975-420-956-3, Ankara, 2003.
8.
Zurück zum Zitat Woodrow P., “Intensive care nursing-a framework for practice”, ISBN13:9-78-0-415-37323-7(hbk), London and Newyork, 2000. Woodrow P., “Intensive care nursing-a framework for practice”, ISBN13:9-78-0-415-37323-7(hbk), London and Newyork, 2000.
9.
Zurück zum Zitat Işık, A.H., and Güler, İ., Pulse oximeter based mobile biotelemetry application. Stud. Health Technol. Inform. 181:197–201, 2012.PubMed Işık, A.H., and Güler, İ., Pulse oximeter based mobile biotelemetry application. Stud. Health Technol. Inform. 181:197–201, 2012.PubMed
10.
Zurück zum Zitat Noblett, W.C., Wilcox, L.R., Scamman, F., Johnson, W.T., and Diaz-Arnold, A., Detection of pulpal circulation in vitro by pulse oximetry. J. Endod. 22:1–5, 1996.CrossRefPubMed Noblett, W.C., Wilcox, L.R., Scamman, F., Johnson, W.T., and Diaz-Arnold, A., Detection of pulpal circulation in vitro by pulse oximetry. J. Endod. 22:1–5, 1996.CrossRefPubMed
11.
Zurück zum Zitat Zapata J, Gómez JJ, Araque Campo R, Matiz Rubio A, Sola A., “A randomised controlled trial of an automated oxygen delivery algorithm for preterm neonates receiving supplemental oxygen without mechanical ventilation”, Regular Article, Acta Paediatr., doi:10.1111/apa.12684, accepted 7 May 2014. Zapata J, Gómez JJ, Araque Campo R, Matiz Rubio A, Sola A., “A randomised controlled trial of an automated oxygen delivery algorithm for preterm neonates receiving supplemental oxygen without mechanical ventilation”, Regular Article, Acta Paediatr., doi:10.​1111/​apa.​12684, accepted 7 May 2014.
12.
Zurück zum Zitat Hakverdioğlu G., “The pulse oxymetry using in assessment of oxygen saturation”, Journal of Cumhuriyet University School of Nursing, 11, 3 ISSN:1 301-6865, 2007. Hakverdioğlu G., “The pulse oxymetry using in assessment of oxygen saturation”, Journal of Cumhuriyet University School of Nursing, 11, 3 ISSN:1 301-6865, 2007.
13.
Zurück zum Zitat Severinghaus J. W., Astrup P. B., “History of blood gas analysis”, Int anesthesiology clinics 25 1987. Severinghaus J. W., Astrup P. B., “History of blood gas analysis”, Int anesthesiology clinics 25 1987.
14.
Zurück zum Zitat Lamberska, T., Vankova, J., and Plavka, R., Efficacy of FiO2 increase during the initial resuscitation of premature infants <29 Weeks: an observational study. Pediatr. Neonatol. 54:373e379, 2013.CrossRef Lamberska, T., Vankova, J., and Plavka, R., Efficacy of FiO2 increase during the initial resuscitation of premature infants <29 Weeks: an observational study. Pediatr. Neonatol. 54:373e379, 2013.CrossRef
15.
Zurück zum Zitat Celik, B., Güler, N.F., and Güler, İ., Design and realization of a microcontroller based E-test strip application device. Instrum. Sci. Technol. 37(6):676–682, 2009.CrossRef Celik, B., Güler, N.F., and Güler, İ., Design and realization of a microcontroller based E-test strip application device. Instrum. Sci. Technol. 37(6):676–682, 2009.CrossRef
16.
Zurück zum Zitat Kapıdere, M., Ahıska, R., and Güler, İ., A new microcontroller-based human brain hypothermia system. J. Med. Syst. 29(5):501–512, 2005.CrossRefPubMed Kapıdere, M., Ahıska, R., and Güler, İ., A new microcontroller-based human brain hypothermia system. J. Med. Syst. 29(5):501–512, 2005.CrossRefPubMed
17.
Zurück zum Zitat Kapıdere, M., Müldür, S., and Güler, İ., Control of dental prosthesis system with microcontroller. J. Med. Syst. 24(2):119–129, 2000.CrossRefPubMed Kapıdere, M., Müldür, S., and Güler, İ., Control of dental prosthesis system with microcontroller. J. Med. Syst. 24(2):119–129, 2000.CrossRefPubMed
18.
Zurück zum Zitat Koçer, S., Canal, M.R., and Güler, İ., Design of low-cost general purpose microcontroller based neuromuscular stimulator. J. Med. Syst. 24(2):91–101, 2000.CrossRefPubMed Koçer, S., Canal, M.R., and Güler, İ., Design of low-cost general purpose microcontroller based neuromuscular stimulator. J. Med. Syst. 24(2):91–101, 2000.CrossRefPubMed
21.
Zurück zum Zitat Chen, K.Y., Chen, F.G., and Hou, T.W., A low-cost reader for automatically collecting vital signs in hospitals. J. Med. Syst. 36:2599–2607, 2012.CrossRefPubMed Chen, K.Y., Chen, F.G., and Hou, T.W., A low-cost reader for automatically collecting vital signs in hospitals. J. Med. Syst. 36:2599–2607, 2012.CrossRefPubMed
22.
Zurück zum Zitat Mihm, F.G., and Halperin, B.D., Noninvasive detection of profound arterial desaturations using a pulse oximetry device. Anesthesiology. 62:85–87, 1985.CrossRefPubMed Mihm, F.G., and Halperin, B.D., Noninvasive detection of profound arterial desaturations using a pulse oximetry device. Anesthesiology. 62:85–87, 1985.CrossRefPubMed
23.
Zurück zum Zitat TAŞKIN G. A., “Comparison of pulse oxymeter and cerebral oxymeter values in healthy newborns at first five minutes of life”, Yüzüncü Yıl University, Faculty of Medicine, Department of Child Health and Diseases, Thesis, VAN – 2011. TAŞKIN G. A., “Comparison of pulse oxymeter and cerebral oxymeter values in healthy newborns at first five minutes of life”, Yüzüncü Yıl University, Faculty of Medicine, Department of Child Health and Diseases, Thesis, VAN – 2011.
24.
Zurück zum Zitat Sung, W., and Chang, K., Health parameter monitoring via a novel wireless system. Appl. Soft Comput. 22:667–680, 2014.CrossRef Sung, W., and Chang, K., Health parameter monitoring via a novel wireless system. Appl. Soft Comput. 22:667–680, 2014.CrossRef
25.
Zurück zum Zitat Dresher R., “Wearable forehead pulse oximetry: minimization of motion and pressure artifacts”, A Thesis Submitted to the Faculty of the Worcester Polytechnic Institute in partial fulfillment of the requirements for the Degree of Master of Science, Submitted on: May 3, 2006. Dresher R., “Wearable forehead pulse oximetry: minimization of motion and pressure artifacts”, A Thesis Submitted to the Faculty of the Worcester Polytechnic Institute in partial fulfillment of the requirements for the Degree of Master of Science, Submitted on: May 3, 2006.
26.
Zurück zum Zitat Mendelson, Y., Pulse oximetry: theory and applications for noninvasive monitoring. Clin. Chem. 38(9):1601–1607, 1992.PubMed Mendelson, Y., Pulse oximetry: theory and applications for noninvasive monitoring. Clin. Chem. 38(9):1601–1607, 1992.PubMed
27.
Zurück zum Zitat Ates G., Polat K., “Measuring of oxygen saturation using pulse oximeter based on fuzzy logic”, Int. Symp. Med. Meas. Appl., May 18–19, Budapest-Hungary, 2012. Ates G., Polat K., “Measuring of oxygen saturation using pulse oximeter based on fuzzy logic”, Int. Symp. Med. Meas. Appl., May 18–19, Budapest-Hungary, 2012.
28.
Zurück zum Zitat Eastwood, G.M., Peck, L., Young, H., Suzuki, S., Garcia, M., and Bellomo, R., Intensive care clinicians’ opinion of conservative oxygen therapy (SpO2 90–92 %) for mechanically ventilated patients. Aust. Crit. Care. 27:120–125, 2014.CrossRefPubMed Eastwood, G.M., Peck, L., Young, H., Suzuki, S., Garcia, M., and Bellomo, R., Intensive care clinicians’ opinion of conservative oxygen therapy (SpO2 90–92 %) for mechanically ventilated patients. Aust. Crit. Care. 27:120–125, 2014.CrossRefPubMed
29.
30.
Zurück zum Zitat William J. M., "Clinical blood gases: assessment and intervention", ISBN 0-7216-8422-X, USA (1990). William J. M., "Clinical blood gases: assessment and intervention", ISBN 0-7216-8422-X, USA (1990).
31.
Zurück zum Zitat Balcı, E., Comparison of the SpO2 / FiO2 ratio and the PaO2/FiO2 ratio and comparison of the effects of varying PEEP values and the factors that effect oxyhemoglobin dissociation curve in patients with or without ALI/ARDS. Ankara University, Department of Anesthesiology and Reanimation, Thesis Medicine, Ankara, 2014. Balcı, E., Comparison of the SpO2 / FiO2 ratio and the PaO2/FiO2 ratio and comparison of the effects of varying PEEP values and the factors that effect oxyhemoglobin dissociation curve in patients with or without ALI/ARDS. Ankara University, Department of Anesthesiology and Reanimation, Thesis Medicine, Ankara, 2014.
32.
Zurück zum Zitat Smith, G.B., Prytherch, D.R., Watson, D., Forde, V., Windsor, A., Schmidt, P.E., Featherstone, P.I., Higgins, B., and Meredith, P., SPO2 values in acute medical admissions breathing air—implications for the British Thoracic Society guideline for emergency oxygen use in adult patients? ELSEVIER, Resuscitation. 83:1201–1205, 2012.CrossRef Smith, G.B., Prytherch, D.R., Watson, D., Forde, V., Windsor, A., Schmidt, P.E., Featherstone, P.I., Higgins, B., and Meredith, P., SPO2 values in acute medical admissions breathing air—implications for the British Thoracic Society guideline for emergency oxygen use in adult patients? ELSEVIER, Resuscitation. 83:1201–1205, 2012.CrossRef
33.
Zurück zum Zitat Işık, H., and Saraçoğlu, E., “The design of thermoelectric footwear heating system via fuzzy logic”. J. Med. Syst. 31:521–527, 2007.CrossRefPubMed Işık, H., and Saraçoğlu, E., “The design of thermoelectric footwear heating system via fuzzy logic”. J. Med. Syst. 31:521–527, 2007.CrossRefPubMed
34.
Zurück zum Zitat Saraoğlu, H.M., and Şanlı, S., A fuzzy logic-based decision support system on anesthetic depth control for helping anesthetists in surgeries. J. Med. Syst. 31:511–519, 2007.CrossRefPubMed Saraoğlu, H.M., and Şanlı, S., A fuzzy logic-based decision support system on anesthetic depth control for helping anesthetists in surgeries. J. Med. Syst. 31:511–519, 2007.CrossRefPubMed
35.
Zurück zum Zitat Kilic, Y.A., and Kilic, I., A novel fuzzy logic inference system for decision support in weaning from mechanical ventilation. J. Med. Syst. 34:1089–1095, 2010.CrossRefPubMed Kilic, Y.A., and Kilic, I., A novel fuzzy logic inference system for decision support in weaning from mechanical ventilation. J. Med. Syst. 34:1089–1095, 2010.CrossRefPubMed
36.
Zurück zum Zitat Allahverdi N., “Expert systems- application of an artificial intelligence”, ISBN: 975-6574-11-9 İstanbul, 2002. Allahverdi N., “Expert systems- application of an artificial intelligence”, ISBN: 975-6574-11-9 İstanbul, 2002.
37.
Zurück zum Zitat Dadone P., “Design Optimization of Fuzzy Logic Systems”, Doctor of Philosophy in Electrical Engineering”, Virginia Polytechnic Institute and State University, May 18, 2001, Blacksburg, Virginia Dadone P., “Design Optimization of Fuzzy Logic Systems”, Doctor of Philosophy in Electrical Engineering”, Virginia Polytechnic Institute and State University, May 18, 2001, Blacksburg, Virginia
38.
Zurück zum Zitat Ferrando C., Carbonell J.A., Gutierrez A., Hernandez J., Belda J., “Mechanical ventilation in the operating room: Adjusting VT, PEEP, and FiO2”, Trends Anaesth. Crit. Care 2, 269e273, Spain, 2012. Ferrando C., Carbonell J.A., Gutierrez A., Hernandez J., Belda J., “Mechanical ventilation in the operating room: Adjusting VT, PEEP, and FiO2”, Trends Anaesth. Crit. Care 2, 269e273, Spain, 2012.
39.
Zurück zum Zitat David W. Chang, Clinical application of mechanical ventilation (fourth edition), library of congress control number: 2012953799, ISBN-13:978-1-1115-3958-0 ISBN-10:1-1115-3958-8, Clifton Park, NY 12065–2919, USA, 2014. David W. Chang, Clinical application of mechanical ventilation (fourth edition), library of congress control number: 2012953799, ISBN-13:978-1-1115-3958-0 ISBN-10:1-1115-3958-8, Clifton Park, NY 12065–2919, USA, 2014.
40.
Zurück zum Zitat Coskun R., Guven M., Sungur M., “Reliability of pulse oximetry in intensive care settings and affecting factors”, Turk. J. Intensive Care Med., 2008;8(1):60–66, Kayseri, 2007. Coskun R., Guven M., Sungur M., “Reliability of pulse oximetry in intensive care settings and affecting factors”, Turk. J. Intensive Care Med., 2008;8(1):60–66, Kayseri, 2007.
Metadaten
Titel
Design and Construction of a Microcontroller-Based Ventilator Synchronized with Pulse Oximeter
verfasst von
Adem Gölcük
Hakan Işık
İnan Güler
Publikationsdatum
01.07.2016
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 7/2016
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-016-0538-x

Weitere Artikel der Ausgabe 7/2016

Journal of Medical Systems 7/2016 Zur Ausgabe

Transactional Processing Systems

Neonatal Jaundice Detection System