Skip to main content
Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging 9/2007

01.09.2007 | Original article

Development of a cost-effective modular SPECT/CT scanner

verfasst von: Dale L. Bailey, Paul J. Roach, Elizabeth A. Bailey, James Hewlett, Ronnie Keijzers

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 9/2007

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To develop a combined SPECT/CT based on a conventional gamma camera with the following design goals: (i) the subject is scanned on the same bed without moving between SPECT and CT scans, (ii) maintenance of full diagnostic utility of both scanners, (iii) a minimal equipment footprint which is adaptable to different site configurations, (iv) a modular design so that either scanner can be upgraded without impacting the other scanner and (v) cost-effectiveness.

Methods

A Philips SKYLight gamma camera was combined with a single-slice helical CT. The CT bed has been modified by mounting on wheels and is attached to a track in the floor when required. The CT bed is used for both the CT and the SPECT scans. The CT bed is parked outside the SKYLight’s active area when not required. The CT data are used for anatomical localisation, attenuation correction and definition of anatomical boundaries (e.g. lobar boundaries in the lungs).

Results

The combined SPECT/CT system is installed in a 6.2 m×4.6 m room. The CT can scan up to 1.3 m of the subject, which is usually sufficient for registration with the SPECT scan. More than 200 subjects have had SPECT/CT scans in the first year of operation. Initially, the main outcome has been improved confidence of localisation of abnormalities. Attenuation correction for all relevant radionuclides has been implemented.

Conclusion

We have developed a combined SPECT/CT using a novel approach based on a low-cost CT scanner. The design is compact, is readily upgradeable and does not compromise either machine’s diagnostic or functional capabilities.
Literatur
1.
Zurück zum Zitat Kuhl DE, Hale J, Eaton WL. Transmission scanning: a useful adjunct to conventional emission scanning for accurately keying isotope deposition to radiographic anatomy. Radiology 1966;87:278.PubMed Kuhl DE, Hale J, Eaton WL. Transmission scanning: a useful adjunct to conventional emission scanning for accurately keying isotope deposition to radiographic anatomy. Radiology 1966;87:278.PubMed
2.
Zurück zum Zitat Anger HO, McRae J. Transmission scintiphotography. J Nucl Med 1968;9(6):267–9.PubMed Anger HO, McRae J. Transmission scintiphotography. J Nucl Med 1968;9(6):267–9.PubMed
3.
Zurück zum Zitat Sorenson JA, Briggs RC, Cameron JR. 99mTc point source for transmission scanning. J Nucl Med 1969;10(5):252–3.PubMed Sorenson JA, Briggs RC, Cameron JR. 99mTc point source for transmission scanning. J Nucl Med 1969;10(5):252–3.PubMed
4.
Zurück zum Zitat Phelps ME, Hoffman EJ, Mullani NA, Ter-Pogossian MM. Application of annihilation coincidence detection to transaxial reconstruction tomography. J Nucl Med 1975;16(3):210–24.PubMed Phelps ME, Hoffman EJ, Mullani NA, Ter-Pogossian MM. Application of annihilation coincidence detection to transaxial reconstruction tomography. J Nucl Med 1975;16(3):210–24.PubMed
5.
Zurück zum Zitat Morozumi T, Nakajima M, Ogawa K, Yuta S. Attenuation correction methods using the information of attenuation distribution for single photon emission CT. Med Imag Tech 1984;2:20–8. Morozumi T, Nakajima M, Ogawa K, Yuta S. Attenuation correction methods using the information of attenuation distribution for single photon emission CT. Med Imag Tech 1984;2:20–8.
6.
Zurück zum Zitat Bailey DL, Hutton BF, Walker PJ. Improved SPECT using simultaneous emission and transmission tomography. J Nucl Med 1987;28(5):844–51.PubMed Bailey DL, Hutton BF, Walker PJ. Improved SPECT using simultaneous emission and transmission tomography. J Nucl Med 1987;28(5):844–51.PubMed
7.
Zurück zum Zitat Butler SP, Bailey DL, McLaughlin AF, Khafagi FA, Stephens FO. SPECT evaluation of arterial perfusion in regional chemotherapy. J Nucl Med 1988;29(5):593–8.PubMed Butler SP, Bailey DL, McLaughlin AF, Khafagi FA, Stephens FO. SPECT evaluation of arterial perfusion in regional chemotherapy. J Nucl Med 1988;29(5):593–8.PubMed
8.
Zurück zum Zitat Beyer T, Kinahan PE, Townsend DW, Sashin D. The use of X-ray CT for attenuation correction of PET data. In: Trendler RC (ed) IEEE Nuclear Science Symposium and Medical Imaging Conference; 1994; Norfolk, VA, USA: Inst of Electrical and Electronic Engineers; 1994. p. 1573–7. Beyer T, Kinahan PE, Townsend DW, Sashin D. The use of X-ray CT for attenuation correction of PET data. In: Trendler RC (ed) IEEE Nuclear Science Symposium and Medical Imaging Conference; 1994; Norfolk, VA, USA: Inst of Electrical and Electronic Engineers; 1994. p. 1573–7.
9.
Zurück zum Zitat Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT scanner for clinical oncology. J Nucl Med 2000;41(8):1369–79.PubMed Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT scanner for clinical oncology. J Nucl Med 2000;41(8):1369–79.PubMed
10.
Zurück zum Zitat Lang TF, Hasegawa BH, Liew SC, Brown JK, Blankespoor SC, Reilly SM, et al. Description of a prototype emission-transmission computed tomography imaging system. J Nucl Med 1992;33(10):1881–7.PubMed Lang TF, Hasegawa BH, Liew SC, Brown JK, Blankespoor SC, Reilly SM, et al. Description of a prototype emission-transmission computed tomography imaging system. J Nucl Med 1992;33(10):1881–7.PubMed
11.
Zurück zum Zitat Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, et al. Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images. Eur J Nucl Med 2000;27(6):619–27.PubMedCrossRef Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, et al. Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images. Eur J Nucl Med 2000;27(6):619–27.PubMedCrossRef
12.
Zurück zum Zitat Tan P, Bailey DL, Meikle SR, Eberl S, Fulton RR, Hutton BF. A scanning line source for simultaneous emission and transmission measurements in SPECT. J Nucl Med 1993;34(10):1752–60.PubMed Tan P, Bailey DL, Meikle SR, Eberl S, Fulton RR, Hutton BF. A scanning line source for simultaneous emission and transmission measurements in SPECT. J Nucl Med 1993;34(10):1752–60.PubMed
13.
Zurück zum Zitat Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imag 1994;MI-13(4):601–9.CrossRef Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imag 1994;MI-13(4):601–9.CrossRef
14.
Zurück zum Zitat Brown S, Bailey DL, Baldock CA. Relationship between CT Hounsfield units and linear attenuation coefficients for a number of single photon-emitting radionuclides [abstract]. J Nucl Med 2006;47(5 Suppl):381P. Brown S, Bailey DL, Baldock CA. Relationship between CT Hounsfield units and linear attenuation coefficients for a number of single photon-emitting radionuclides [abstract]. J Nucl Med 2006;47(5 Suppl):381P.
15.
Zurück zum Zitat Philips. Installation and Siting Support - CT/PQ SERIES SYSTEM (400 VAC); 2000. Philips. Installation and Siting Support - CT/PQ SERIES SYSTEM (400 VAC); 2000.
16.
Zurück zum Zitat Moss M, McLean D. Paediatric and adult computed tomography practice and patient dose in Australia. Australasian Radiol 2006;50:33–40.CrossRef Moss M, McLean D. Paediatric and adult computed tomography practice and patient dose in Australia. Australasian Radiol 2006;50:33–40.CrossRef
17.
Zurück zum Zitat Kneifel S. Radiation dose and radiation protection. In: von Shultness GK (ed) Clinical molecular anatomic imaging. Philadelphia: Lippincott; 2003. p. 68–71. Kneifel S. Radiation dose and radiation protection. In: von Shultness GK (ed) Clinical molecular anatomic imaging. Philadelphia: Lippincott; 2003. p. 68–71.
18.
Zurück zum Zitat ICRP. ICRP Publication 53: Radiation dose to patients from radiopharmaceuticals; 1988. ICRP. ICRP Publication 53: Radiation dose to patients from radiopharmaceuticals; 1988.
20.
Zurück zum Zitat Towson JEC. Radiation dosimetry and protection in PET. In: Valk P, Bailey DL, Townsend DW, Maisey MN (eds) Positron emission tomography: basic science and clinical practice. London: Springer, 2003. Towson JEC. Radiation dosimetry and protection in PET. In: Valk P, Bailey DL, Townsend DW, Maisey MN (eds) Positron emission tomography: basic science and clinical practice. London: Springer, 2003.
21.
Zurück zum Zitat Roach PJ, Schembri GP, Ho Shon IA, Bailey EA, Bailey DL. SPECT/CT imaging using a spiral CT scanner for anatomical localisation: impact on diagnostic accuracy and reporter confidence in clinical practice. Nucl Med Commun 2006;27:977–87.PubMedCrossRef Roach PJ, Schembri GP, Ho Shon IA, Bailey EA, Bailey DL. SPECT/CT imaging using a spiral CT scanner for anatomical localisation: impact on diagnostic accuracy and reporter confidence in clinical practice. Nucl Med Commun 2006;27:977–87.PubMedCrossRef
22.
Zurück zum Zitat Delbeke D, Coleman RE, Guiberteau MJ, Brown ML, Royal HD, Siegel BA, et al. Procedure guideline for SPECT/CT imaging 1.0. J Nucl Med 2006;47(7):1227–34.PubMed Delbeke D, Coleman RE, Guiberteau MJ, Brown ML, Royal HD, Siegel BA, et al. Procedure guideline for SPECT/CT imaging 1.0. J Nucl Med 2006;47(7):1227–34.PubMed
23.
Zurück zum Zitat Bailey DL. Is PET the future of nuclear medicine? (Invited Commentary). Eur J Nucl Med Mol Imag 2003;30(7):1045–6.CrossRef Bailey DL. Is PET the future of nuclear medicine? (Invited Commentary). Eur J Nucl Med Mol Imag 2003;30(7):1045–6.CrossRef
24.
Zurück zum Zitat Kashiwagi T, Yutani K, Fukuchi M, Naruse H, Iwasaki T, Yokozuka K, et al. Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT. Ann Nucl Med 2002;16(4):255–61.PubMedCrossRef Kashiwagi T, Yutani K, Fukuchi M, Naruse H, Iwasaki T, Yokozuka K, et al. Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT. Ann Nucl Med 2002;16(4):255–61.PubMedCrossRef
25.
Zurück zum Zitat Nehmeh SA, Erdi YE, Ling CC, Rosenzweig KE, Squire OD, Braban LE, et al. Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. Med Phys 2002;29(3):366–71.PubMedCrossRef Nehmeh SA, Erdi YE, Ling CC, Rosenzweig KE, Squire OD, Braban LE, et al. Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. Med Phys 2002;29(3):366–71.PubMedCrossRef
26.
Zurück zum Zitat Lardinois D, Weder W, Hany TF, Kamel EM, Korom S, Seifert B, et al. Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 2003;348:2500–7.PubMedCrossRef Lardinois D, Weder W, Hany TF, Kamel EM, Korom S, Seifert B, et al. Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 2003;348:2500–7.PubMedCrossRef
27.
Zurück zum Zitat Bar-Shalom R, Yefremov N, Guralnik L, Gaitini D, Frenkel A, Kuten A, et al. Clinical performance of PET/CT in evaluation of cancer: additional value for diagnostic imaging and patient management. J Nucl Med 2003;44(8):1200–9.PubMed Bar-Shalom R, Yefremov N, Guralnik L, Gaitini D, Frenkel A, Kuten A, et al. Clinical performance of PET/CT in evaluation of cancer: additional value for diagnostic imaging and patient management. J Nucl Med 2003;44(8):1200–9.PubMed
28.
Zurück zum Zitat Coleman R, Delbeke D, Guiberteau M, Conti P, Royal H, Weinreb J, et al. Concurrent PET/CT with an integrated imaging system: intersociety dialogue from the Joint Working Group of the American College of Radiology, the Society of Nuclear Medicine, and the Society of Computed Body Tomography and Magnetic Resonance. J Nucl Med 2005;46:1225–39.PubMed Coleman R, Delbeke D, Guiberteau M, Conti P, Royal H, Weinreb J, et al. Concurrent PET/CT with an integrated imaging system: intersociety dialogue from the Joint Working Group of the American College of Radiology, the Society of Nuclear Medicine, and the Society of Computed Body Tomography and Magnetic Resonance. J Nucl Med 2005;46:1225–39.PubMed
29.
Zurück zum Zitat Townsend DW, Cherry SR. Combining anatomy and function: the path to true image fusion. Eur Radiol 2001;11(10):1968–74.PubMedCrossRef Townsend DW, Cherry SR. Combining anatomy and function: the path to true image fusion. Eur Radiol 2001;11(10):1968–74.PubMedCrossRef
Metadaten
Titel
Development of a cost-effective modular SPECT/CT scanner
verfasst von
Dale L. Bailey
Paul J. Roach
Elizabeth A. Bailey
James Hewlett
Ronnie Keijzers
Publikationsdatum
01.09.2007
Verlag
Springer-Verlag
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 9/2007
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-006-0364-3

Weitere Artikel der Ausgabe 9/2007

European Journal of Nuclear Medicine and Molecular Imaging 9/2007 Zur Ausgabe