Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 11/2012

01.11.2012 | Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Do Survival Rate and Serum Ion Concentrations 10 Years After Metal-on-Metal Hip Resurfacing Provide Evidence for Continued Use?

verfasst von: Albrecht Hartmann, MD, Jörg Lützner, MD, Stephan Kirschner, MD, Wolf-Christoph Witzleb, MD, Klaus-Peter Günther, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 11/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

Owing to concerns attributable to problems associated with metal-on-metal bearing surfaces, current evidence for the use of hip resurfacing is unclear. Survival rates reported from registries and individual studies are controversial and the limited long-term studies do not conclusively allow one to judge whether hip resurfacing is still a reasonable alternative to conventional THA.

Questions/purposes

We asked whether the long-term survival rate of hip resurfacing is comparable to that of conventional THA and certain factors can be identified that influence serum ion concentration 10 years postoperatively. We specifically assessed (1) the 10-year survivorship in the whole cohort and in male and female patients, (2) serum concentrations of metal ions in patients with hip resurfacing who had not undergone revision surgery, and (3) potential influencing factors on the serum ion concentration.

Methods

We retrospectively reviewed our first 95 patients who had 100 hip resurfacings performed from 1998 to 2001. The median age of the patients at surgery was 52 years (range, 28–69 years); 49% were men. We assessed the survival rate (revision for any reason as the end point), radiographic changes, and serum ion concentrations for cobalt, chromium, and molybdenum. The correlations between serum ion concentration and patient-related factors (age, sex, BMI, activity) and implant-related factors (implant size, cup inclination, stem-shaft angle) were investigated. The minimum followup was 9.3 years (mean, 10 years; range, 9.3–10.5 years).

Results

The 10-year survivorship was 88% for the total cohort. The overall survival rate was greater in men (93%) than in women (84%). Median serum ion levels were 1.9 μg/L for chromium, 1.3 μg/L for cobalt, and 1.6 μg/L for molybdenum. Radiolucent lines around acetabular implants were observed in 4% and femoral neck thinning in 5%.

Conclusions

Although our overall failure rate was greater than anticipated, the relatively low serum ion levels and no revisions for pseudotumors in young male patients up to 10 years postoperatively provide some evidence of the suitability of hip resurfacing in this subgroup.

Level of Evidence

Level IV, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Akbar M, Brewer JM, Grant MH. Effect of chromium and cobalt ions on primary human lymphocytes in vitro. J Immunotoxicol. 2011:8:140–149.PubMedCrossRef Akbar M, Brewer JM, Grant MH. Effect of chromium and cobalt ions on primary human lymphocytes in vitro. J Immunotoxicol. 2011:8:140–149.PubMedCrossRef
2.
Zurück zum Zitat Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA. Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg Am. 2004:86:28–39.PubMed Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA. Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg Am. 2004:86:28–39.PubMed
3.
Zurück zum Zitat Amstutz HC, Le Duff MJ, Campbell PA, Gruen TA, Wisk LE. Clinical and radiographic results of metal-on-metal hip resurfacing with a minimum ten-year follow-up. J Bone Joint Surg Am. 2010:92:2663–2671.PubMedCrossRef Amstutz HC, Le Duff MJ, Campbell PA, Gruen TA, Wisk LE. Clinical and radiographic results of metal-on-metal hip resurfacing with a minimum ten-year follow-up. J Bone Joint Surg Am. 2010:92:2663–2671.PubMedCrossRef
5.
Zurück zum Zitat Baker RP, Pollard TC, Eastaugh-Waring SJ, Bannister GC. A medium-term comparison of hybrid hip replacement and Birmingham hip resurfacing in active young patients. J Bone Joint Surg Br. 2011:93:158–163.PubMedCrossRef Baker RP, Pollard TC, Eastaugh-Waring SJ, Bannister GC. A medium-term comparison of hybrid hip replacement and Birmingham hip resurfacing in active young patients. J Bone Joint Surg Br. 2011:93:158–163.PubMedCrossRef
6.
Zurück zum Zitat Beaule PE, Dorey FJ, Hoke R, Le DM, Amstutz HC. The value of patient activity level in the outcome of total hip arthroplasty. J Arthroplasty. 2006:21:547–552.PubMedCrossRef Beaule PE, Dorey FJ, Hoke R, Le DM, Amstutz HC. The value of patient activity level in the outcome of total hip arthroplasty. J Arthroplasty. 2006:21:547–552.PubMedCrossRef
7.
Zurück zum Zitat Beaule PE, Dorey FJ, Le Duff MJ, Gruen T, Amstutz HC. Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip. Clin Orthop Relat Res. 2004:418:87–93.PubMedCrossRef Beaule PE, Dorey FJ, Le Duff MJ, Gruen T, Amstutz HC. Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip. Clin Orthop Relat Res. 2004:418:87–93.PubMedCrossRef
8.
Zurück zum Zitat Beaule PE, Kim PR, Powell J, Mackenzie J, Werle J, Antoniou J, Huk O, Vendittoli PA, Lavigne M, Smith F, Naudie D, McCalden R, Bourne R, Schemitsch E, Garbuz D, Greidanus N, Duncan C, Belzile E; Canadian Hip Resurfacing Study Group. A survey on the prevalence of pseudotumors with metal-on-metal hip resurfacing in Canadian academic centers. J Bone Joint Surg Am. 2011:93(suppl 2):118–121.CrossRef Beaule PE, Kim PR, Powell J, Mackenzie J, Werle J, Antoniou J, Huk O, Vendittoli PA, Lavigne M, Smith F, Naudie D, McCalden R, Bourne R, Schemitsch E, Garbuz D, Greidanus N, Duncan C, Belzile E; Canadian Hip Resurfacing Study Group. A survey on the prevalence of pseudotumors with metal-on-metal hip resurfacing in Canadian academic centers. J Bone Joint Surg Am. 2011:93(suppl 2):118–121.CrossRef
9.
Zurück zum Zitat Corten K, MacDonald SJ. Hip resurfacing data from national joint registries: what do they tell us? What do they not tell us? Clin Orthop Relat Res. 2010:468:351–357.PubMedCrossRef Corten K, MacDonald SJ. Hip resurfacing data from national joint registries: what do they tell us? What do they not tell us? Clin Orthop Relat Res. 2010:468:351–357.PubMedCrossRef
10.
Zurück zum Zitat Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004:86:177–184.PubMedCrossRef Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004:86:177–184.PubMedCrossRef
11.
Zurück zum Zitat Daniel J, Ziaee H, Kamali A, Pradhan C, Band T, McMinn DJ. Ten-year results of a double-heat-treated metal-on-metal hip resurfacing. J Bone Joint Surg Br. 2010:92:20–27.PubMedCrossRef Daniel J, Ziaee H, Kamali A, Pradhan C, Band T, McMinn DJ. Ten-year results of a double-heat-treated metal-on-metal hip resurfacing. J Bone Joint Surg Br. 2010:92:20–27.PubMedCrossRef
12.
Zurück zum Zitat Daniel J, Ziaee H, Pradhan C, McMinn DJ. Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2009:91:176–179.PubMed Daniel J, Ziaee H, Pradhan C, McMinn DJ. Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2009:91:176–179.PubMed
13.
Zurück zum Zitat Desy NM, Bergeron SG, Petit A, Huk OL, Antoniou J. Surgical variables influence metal ion levels after hip resurfacing. Clin Orthop Relat Res. 2011:469:1635–1641.PubMedCrossRef Desy NM, Bergeron SG, Petit A, Huk OL, Antoniou J. Surgical variables influence metal ion levels after hip resurfacing. Clin Orthop Relat Res. 2011:469:1635–1641.PubMedCrossRef
14.
Zurück zum Zitat Glyn-Jones S, Pandit H, Kwon YM, Doll H, Gill HS, Murray DW. Risk factors for inflammatory pseudotumour formation following hip resurfacing. J Bone Joint Surg Br. 2009:91:1566–1574.PubMedCrossRef Glyn-Jones S, Pandit H, Kwon YM, Doll H, Gill HS, Murray DW. Risk factors for inflammatory pseudotumour formation following hip resurfacing. J Bone Joint Surg Br. 2009:91:1566–1574.PubMedCrossRef
15.
Zurück zum Zitat Griffin WL, Nanson CJ, Springer BD, Davies MA, Fehring TK. Reduced articular surface of one-piece cups: a cause of runaway wear and early failure. Clin Orthop Relat Res. 2010:468:2328–2332.PubMedCrossRef Griffin WL, Nanson CJ, Springer BD, Davies MA, Fehring TK. Reduced articular surface of one-piece cups: a cause of runaway wear and early failure. Clin Orthop Relat Res. 2010:468:2328–2332.PubMedCrossRef
16.
Zurück zum Zitat Grigoris P, Roberts P, Panousis K. The development of the Durom™ metal-on-metal hip resurfacing. Hip Int. 2006:16(suppl 4):65–72.PubMed Grigoris P, Roberts P, Panousis K. The development of the Durom™ metal-on-metal hip resurfacing. Hip Int. 2006:16(suppl 4):65–72.PubMed
17.
Zurück zum Zitat Haddad FS, Thakrar RR, Hart AJ, Skinner JA, Nargol AV, Nolan JF, Gill HS, Murray DW, Blom AW, Case CP. Metal-on-metal bearings: the evidence so far. J Bone Joint Surg Br. 2011:93:572–579.PubMed Haddad FS, Thakrar RR, Hart AJ, Skinner JA, Nargol AV, Nolan JF, Gill HS, Murray DW, Blom AW, Case CP. Metal-on-metal bearings: the evidence so far. J Bone Joint Surg Br. 2011:93:572–579.PubMed
18.
Zurück zum Zitat Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969:51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969:51:737–755.PubMed
19.
Zurück zum Zitat Hart AJ, Skinner JA, Henckel J, Sampson B, Gordon F. Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing. Clin Orthop Relat Res. 2011:469:2590–2597.PubMedCrossRef Hart AJ, Skinner JA, Henckel J, Sampson B, Gordon F. Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing. Clin Orthop Relat Res. 2011:469:2590–2597.PubMedCrossRef
20.
Zurück zum Zitat Kwon YM, Ostlere SJ, Lardy-Smith P, Athanasou NA, Gill HS, Murray DW. “Asymptomatic” pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. J Arthroplasty. 2011:26:511–518.PubMedCrossRef Kwon YM, Ostlere SJ, Lardy-Smith P, Athanasou NA, Gill HS, Murray DW. “Asymptomatic” pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. J Arthroplasty. 2011:26:511–518.PubMedCrossRef
21.
Zurück zum Zitat Langton DJ, Jameson SS, Joyce TJ, Gandhi JN, Sidaginamale R, Merredy P, Lord J, Nargol AV. Accelerating failure rate of the ASR total hip replacement. J Bone Joint Surg Br. 2011:93:1011–1016.PubMedCrossRef Langton DJ, Jameson SS, Joyce TJ, Gandhi JN, Sidaginamale R, Merredy P, Lord J, Nargol AV. Accelerating failure rate of the ASR total hip replacement. J Bone Joint Surg Br. 2011:93:1011–1016.PubMedCrossRef
22.
Zurück zum Zitat Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg Br. 2010:92:38–46.PubMedCrossRef Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg Br. 2010:92:38–46.PubMedCrossRef
23.
Zurück zum Zitat Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP, Nargol AV, De Smet KA. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br. 2011:93:164–171.PubMedCrossRef Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP, Nargol AV, De Smet KA. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br. 2011:93:164–171.PubMedCrossRef
24.
Zurück zum Zitat Langton DJ, Sprowson AP, Joyce TJ, Reed M, Carluke I, Partington P, Nargol AV. Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties. J Bone Joint Surg Br. 2009:91:1287–1295.PubMedCrossRef Langton DJ, Sprowson AP, Joyce TJ, Reed M, Carluke I, Partington P, Nargol AV. Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties. J Bone Joint Surg Br. 2009:91:1287–1295.PubMedCrossRef
25.
Zurück zum Zitat Lingard EA, Muthumayandi K, Holland JP. Comparison of patient-reported outcomes between hip resurfacing and total hip replacement. J Bone Joint Surg Br. 2009:91:1550–1554.PubMedCrossRef Lingard EA, Muthumayandi K, Holland JP. Comparison of patient-reported outcomes between hip resurfacing and total hip replacement. J Bone Joint Surg Br. 2009:91:1550–1554.PubMedCrossRef
26.
Zurück zum Zitat Lugowski SJ, Smith DC, McHugh AD, Van Loon JC. Determination of chromium, cobalt and molybdenum in synovial fluid by GFAAS. J Trace Elem Electrolytes Health Dis. 1991:5:23–29.PubMed Lugowski SJ, Smith DC, McHugh AD, Van Loon JC. Determination of chromium, cobalt and molybdenum in synovial fluid by GFAAS. J Trace Elem Electrolytes Health Dis. 1991:5:23–29.PubMed
27.
Zurück zum Zitat McArthur JR, Costa M, Griffin DR, Krikler SJ, Parsons N, Foguet PR. Groin pain following hip resurfacing: a case-control study. Hip Int. 2011:21:602–609.PubMedCrossRef McArthur JR, Costa M, Griffin DR, Krikler SJ, Parsons N, Foguet PR. Groin pain following hip resurfacing: a case-control study. Hip Int. 2011:21:602–609.PubMedCrossRef
28.
Zurück zum Zitat McBryde CW, Revell MP, Thomas AM, Treacy RB, Pynsent PB. The influence of surgical approach on outcome in Birmingham Hip Resurfacing. Clin Orthop Relat Res. 2008:466:920–926.PubMedCrossRef McBryde CW, Revell MP, Thomas AM, Treacy RB, Pynsent PB. The influence of surgical approach on outcome in Birmingham Hip Resurfacing. Clin Orthop Relat Res. 2008:466:920–926.PubMedCrossRef
29.
Zurück zum Zitat McGrory B, Barrack R, Lachiewicz PF, Schmalzried T, Yates AJ, Watters WC, Turkelson CM, Wies JL, Andre JS. Modern metal-on-metal hip resurfacing. J Am Acad Orthop Surg. 2010:18:306–314.PubMed McGrory B, Barrack R, Lachiewicz PF, Schmalzried T, Yates AJ, Watters WC, Turkelson CM, Wies JL, Andre JS. Modern metal-on-metal hip resurfacing. J Am Acad Orthop Surg. 2010:18:306–314.PubMed
30.
Zurück zum Zitat Mont MA, Seyler TM, Ulrich SD, Beaule PE, Boyd HS, Grecula MJ, Goldberg VM, Kennedy WR, Marker DR, Schmalzried T, Sparling EA, Vail TP, Amstutz HC. Effect of changing indications and techniques on total hip resurfacing. Clin Orthop Relat Res.2007:465:63–70.PubMed Mont MA, Seyler TM, Ulrich SD, Beaule PE, Boyd HS, Grecula MJ, Goldberg VM, Kennedy WR, Marker DR, Schmalzried T, Sparling EA, Vail TP, Amstutz HC. Effect of changing indications and techniques on total hip resurfacing. Clin Orthop Relat Res.2007:465:63–70.PubMed
31.
Zurück zum Zitat Murray DW, Carr AJ, Bulstrode C. Survival analysis of joint replacements. J Bone Joint Surg Br. 1993:75:697–704.PubMed Murray DW, Carr AJ, Bulstrode C. Survival analysis of joint replacements. J Bone Joint Surg Br. 1993:75:697–704.PubMed
32.
Zurück zum Zitat Murray DW, Grammatopoulos G, Gundle R, Gibbons CL, Whitwell D, Taylor A, Glyn-Jones S, Pandit HG, Ostlere S, Gill HS, Athanasou N, McLardy-Smith P. Hip resurfacing and pseudotumour. Hip Int. 2011:21:279–283.PubMedCrossRef Murray DW, Grammatopoulos G, Gundle R, Gibbons CL, Whitwell D, Taylor A, Glyn-Jones S, Pandit HG, Ostlere S, Gill HS, Athanasou N, McLardy-Smith P. Hip resurfacing and pseudotumour. Hip Int. 2011:21:279–283.PubMedCrossRef
33.
Zurück zum Zitat National Institute for Clinical Excellence. Guidance on the selection of prostheses for primary total hip replacement (TA2). Available at: http://www.nice.org.uk. Accessed October 8, 2011. National Institute for Clinical Excellence. Guidance on the selection of prostheses for primary total hip replacement (TA2). Available at: http://​www.​nice.​org.​uk. Accessed October 8, 2011.
34.
Zurück zum Zitat Nishii T, Sugano N, Miki H, Takao M, Koyama T, Yoshikawa H. Five-year results of metal-on-metal resurfacing arthroplasty in Asian patients. J Arthroplasty. 2007:22:176–183.PubMedCrossRef Nishii T, Sugano N, Miki H, Takao M, Koyama T, Yoshikawa H. Five-year results of metal-on-metal resurfacing arthroplasty in Asian patients. J Arthroplasty. 2007:22:176–183.PubMedCrossRef
35.
Zurück zum Zitat Nunley RM, Zhu J, Brooks PJ, Engh CA, Raterman SJ, Rogerson JS, Barrack RL. The learning curve for adopting hip resurfacing among hip specialists. Clin Orthop Relat Res. 2010:468:382–391.PubMedCrossRef Nunley RM, Zhu J, Brooks PJ, Engh CA, Raterman SJ, Rogerson JS, Barrack RL. The learning curve for adopting hip resurfacing among hip specialists. Clin Orthop Relat Res. 2010:468:382–391.PubMedCrossRef
36.
Zurück zum Zitat Olsen M, Davis ET, Gallie PA, Waddell JP, Schemitsch EH. The reliability of radiographic assessment of femoral neck-shaft and implant angulation in hip resurfacing arthroplasty. J Arthroplasty. 2009:24:333–340.PubMedCrossRef Olsen M, Davis ET, Gallie PA, Waddell JP, Schemitsch EH. The reliability of radiographic assessment of femoral neck-shaft and implant angulation in hip resurfacing arthroplasty. J Arthroplasty. 2009:24:333–340.PubMedCrossRef
37.
Zurück zum Zitat Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, Ostlere S, Athanasou N, Gill HS, Murray DW. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2008:90:847–851.PubMedCrossRef Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, Ostlere S, Athanasou N, Gill HS, Murray DW. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2008:90:847–851.PubMedCrossRef
38.
Zurück zum Zitat Prohaska C, Pomazal K, Steffan I. ETAAS method for the determination of Cd, Cr, Cu, Mn and Se in blood fractions and whole blood. Fresenius J Anal Chem. 2000:368:627–632.PubMedCrossRef Prohaska C, Pomazal K, Steffan I. ETAAS method for the determination of Cd, Cr, Cu, Mn and Se in blood fractions and whole blood. Fresenius J Anal Chem. 2000:368:627–632.PubMedCrossRef
39.
Zurück zum Zitat Prosser GH, Yates PJ, Wood DJ, Graves SE, Steiger RN, Miller LN. Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revision. Acta Orthop. 2010:81:66–71.PubMedCrossRef Prosser GH, Yates PJ, Wood DJ, Graves SE, Steiger RN, Miller LN. Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revision. Acta Orthop. 2010:81:66–71.PubMedCrossRef
40.
Zurück zum Zitat Reito A, Puolakka T, Paakkala A, Pajamaki J. Assessment of inter- and intra-observer reliability in the determination of radiographic version and inclination of the cup in metal-on-metal hip resurfacing. Int Orthop. 2012;36:519–525.PubMedCrossRef Reito A, Puolakka T, Paakkala A, Pajamaki J. Assessment of inter- and intra-observer reliability in the determination of radiographic version and inclination of the cup in metal-on-metal hip resurfacing. Int Orthop. 2012;36:519–525.PubMedCrossRef
41.
Zurück zum Zitat Shimmin A, Beaule PE, Campbell P. Metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Am. 2008:90:637–654.PubMedCrossRef Shimmin A, Beaule PE, Campbell P. Metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Am. 2008:90:637–654.PubMedCrossRef
42.
Zurück zum Zitat Shimmin AJ, Back D. Femoral neck fractures following Birmingham Hip Resurfacing: a national review of 50 cases. J Bone Joint Surg Br. 2005:87:463–464.PubMedCrossRef Shimmin AJ, Back D. Femoral neck fractures following Birmingham Hip Resurfacing: a national review of 50 cases. J Bone Joint Surg Br. 2005:87:463–464.PubMedCrossRef
43.
Zurück zum Zitat Smith TO, Nichols R, Donell ST, Hing CB. The clinical and radiological outcomes of hip resurfacing versus total hip arthroplasty: a meta-analysis and systematic review. Acta Orthop. 2010:81:684–695.PubMedCrossRef Smith TO, Nichols R, Donell ST, Hing CB. The clinical and radiological outcomes of hip resurfacing versus total hip arthroplasty: a meta-analysis and systematic review. Acta Orthop. 2010:81:684–695.PubMedCrossRef
44.
Zurück zum Zitat Springer BD, Connelly SE, Odum SM, Fehring TK, Griffin WL, Mason JB, Masonis JL. Cementless femoral components in young patients: review and meta-analysis of total hip arthroplasty and hip resurfacing. J Arthroplasty. 2009:24:2–8.PubMedCrossRef Springer BD, Connelly SE, Odum SM, Fehring TK, Griffin WL, Mason JB, Masonis JL. Cementless femoral components in young patients: review and meta-analysis of total hip arthroplasty and hip resurfacing. J Arthroplasty. 2009:24:2–8.PubMedCrossRef
46.
Zurück zum Zitat Treacy RB, McBryde CW, Pynsent PB. Birmingham Hip Resurfacing arthroplasty: a minimum follow-up of five years. J Bone Joint Surg Br. 2005:87:167–170.PubMedCrossRef Treacy RB, McBryde CW, Pynsent PB. Birmingham Hip Resurfacing arthroplasty: a minimum follow-up of five years. J Bone Joint Surg Br. 2005:87:167–170.PubMedCrossRef
47.
Zurück zum Zitat Treacy RB, McBryde CW, Shears E, Pynsent PB. Birmingham Hip Resurfacing: a minimum follow-up of ten years. J Bone Joint Surg Br. 2011:93:27–33.PubMedCrossRef Treacy RB, McBryde CW, Shears E, Pynsent PB. Birmingham Hip Resurfacing: a minimum follow-up of ten years. J Bone Joint Surg Br. 2011:93:27–33.PubMedCrossRef
48.
Zurück zum Zitat Van der Weegen W, Hoekstra HJ, Sijbesma T, Bos E, Schemitsch EH, Poolman RW. Survival of metal-on-metal hip resurfacing arthroplasty: a systematic review of the literature. J Bone Joint Surg Br. 2011:93:298–306.PubMedCrossRef Van der Weegen W, Hoekstra HJ, Sijbesma T, Bos E, Schemitsch EH, Poolman RW. Survival of metal-on-metal hip resurfacing arthroplasty: a systematic review of the literature. J Bone Joint Surg Br. 2011:93:298–306.PubMedCrossRef
49.
Zurück zum Zitat Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg Br. 2007:89:441–448.PubMedCrossRef Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg Br. 2007:89:441–448.PubMedCrossRef
50.
Zurück zum Zitat Witzleb WC, Arnold M, Krummenauer F, Knecht A, Ranisch H, Guenther KP. Birmingham Hip Resurfacing arthroplasty: short-term clinical and radiographic outcome. Eur J Med Res. 2008:13:39–46.PubMed Witzleb WC, Arnold M, Krummenauer F, Knecht A, Ranisch H, Guenther KP. Birmingham Hip Resurfacing arthroplasty: short-term clinical and radiographic outcome. Eur J Med Res. 2008:13:39–46.PubMed
Metadaten
Titel
Do Survival Rate and Serum Ion Concentrations 10 Years After Metal-on-Metal Hip Resurfacing Provide Evidence for Continued Use?
verfasst von
Albrecht Hartmann, MD
Jörg Lützner, MD
Stephan Kirschner, MD
Wolf-Christoph Witzleb, MD
Klaus-Peter Günther, MD
Publikationsdatum
01.11.2012
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 11/2012
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2329-0

Weitere Artikel der Ausgabe 11/2012

Clinical Orthopaedics and Related Research® 11/2012 Zur Ausgabe

Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Does Standing Affect Acetabular Component Inclination and Version After THA?

Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Is a Cementless Dual Mobility Socket in Primary THA a Reasonable Option?

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.