Skip to main content
Erschienen in: Systematic Reviews 1/2012

Open Access 01.12.2012 | Research

Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials

verfasst von: Lucas Lodi-Junqueira, Marcos Roberto de Sousa, Leonardo Carvalho da Paixão, Silvana Márcia Bruschi Kelles, Carlos Faria Santos Amaral, Antonio L Ribeiro

Erschienen in: Systematic Reviews | Ausgabe 1/2012

Abstract

Background

The role of intravascular ultrasound (IVUS) in percutaneous coronary interventions (PCI) is still controversial despite several previously published meta-analyses. A meta-analysis to evaluate the controversial role of IVUS-guided PCI with bare-metal stenting was performed and a previous published meta-analysis was re-evaluated in order to clarify the discrepancy between results of these studies.

Methods

A systematic review was performed by an electronic search of the PubMed, Embase and Web of Knowledge databases and by a manual search of reference lists for randomized controlled trials published until April 2011, with clinical outcomes and, at least, six months of clinical follow-up. A meta-analysis based on the intention to treat was performed with the selected studies.

Results

Five studies and 1,754 patients were included. There were no differences in death (OR = 1.86; 95% CI = 0.88-3.95; p = 0.10), non-fatal myocardial infarction (OR = 0.65; 95% CI = 0.27-1.58; p = 0.35) and major adverse cardiac events (OR = 0.74; 95% CI = 0.49-1.13; p = 0.16). An analysis of the previous published meta-analysis strongly suggested the presence of publication bias.

Conclusions

There is no evidence to recommend routine IVUS-guided PCI with bare-metal stent implantation. This may be explained by the paucity and heterogeneity of the studies published so far.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​2046-4053-1-42) contains supplementary material, which is available to authorized users.

Competing interest

The authors declare no conflicts of interest in the preparation and in the presentation of this meta-analysis.

Authors’ contributions

LLJ participated in the design of the study, retrieved, reviewed and selected the articles from electronic and manual searches, helped to discuss the results and to draft the manuscript. MRS participated in the design of the study, performed the statistical analysis and helped to discuss the results and to draft the manuscript. LCP retrieved, reviewed and selected the articles from electronic and manual searches. SMBK participated in the design of the study and helped to retrieve articles from electronic searches, to discuss the results and to draft the manuscript. CFSA participated in the design of the study and helped to discuss the results and to draft the manuscript. ALR participated in the coordination of the study, helped to select the articles, to discuss the results and to draft the manuscript. All authors read and approved the final manuscript.

Background

Since the first studies of intravascular ultrasound (IVUS) were published in 1989 [14], the technique has been widely used in clinical research and has contributed to technological improvements in interventional cardiology [5]. As a diagnostic tool, IVUS helps in the assessment of coronary lesions classified as moderate based on angiography, especially those located in the left main coronary artery [6, 7], and in the assessment of long lesions, small artery lesions, bifurcations and in-stent restenosis [8, 9]. As an ancillary technique in percutaneous coronary intervention (PCI), IVUS is useful in the evaluation of the target lesion and during stent implantation [10]. In theory, its use should reduce the risk of major adverse cardiovascular events (MACE) because of lower restenosis and stent thrombosis rates.
The first published systematic review evaluated the role of IVUS in PCI as well as its cost-effectiveness and did not show any difference between IVUS and angio-guided PCI [11]. A few years later, a meta-analysis did not show any reduction in death or myocardial infarction (MI) but revealed reductions in repeat revascularization and angiographic restenosis after a six-month follow-up [12]. This was corroborated by another meta-analysis that suggested an improvement in acute post-interventional results (larger minimal luminal diameter) and lower repeat revascularization, angiographic restenosis and MACE rates, but showed no effect on death or MI during the follow-up period of six to thirty months [13].
Since IVUS clinical benefit is still controversial and conclusions of meta-analyses may be misleading due to methodological issues, we performed a meta-analysis to assess the effect of IVUS in PCI with bare-metal stent implantation on clinically relevant outcomes, assessing the presence of publication bias. In addition, a critical review of the last published meta-analysis [13] was performed in order to clarify the discrepancy in the results found in this analysis comparing to medical literature.

Methods

The protocol for the present systematic review was based on the PRISMA Statement [14] and it was registered in the PROSPERO database (CRD42012002767).
We performed an electronic search of PubMed, Embase and Web of Knowledge databases with the following terms: Myocardial Ischemia; Ischemic Heart Disease; Acute Coronary Syndrome; Angina; Coronary Disease; Coronary Artery Disease; Coronary Occlusion; Coronary Thrombosis and Myocardial Infarction, in association with the terms Interventional Ultraso*; Intravascular Ultraso*; Intracoronary Ultraso*; IVUS and ICUS.
A manual search was also performed to retrieve potential articles cited in previous meta-analyses, in review articles and those considered to be relevant by the reviewers. The electronic search, which evaluated the articles included in the databases through April 2011, was limited neither by publication date nor by language.

Eligibility criteria

Only randomized controlled trials that compared IVUS-guided PCI with angiography-guided PCI, with clinical outcomes, and at least six months of clinical follow-up, were included in quantitative synthesis. The clinical outcomes considered were death, nonfatal MI and the combined endpoint of MACE (death, nonfatal MI, or repeat revascularization). For repeat revascularization, a report of any new coronary revascularization (surgical or percutaneous) was considered, regardless of the lesion and of the vessel treated. Surrogate outcomes, such as angiographic outcomes, were not taken into account because these can show a positive result with no effect (or harmful effect) on clinical outcomes [15]. These clinical outcomes (death, nonfatal MI and MACE) were considered primary endpoints in our meta-analysis.

Study selection

The titles and abstracts from the articles retrieved by the search strategy had been independently evaluated by two reviewers (LCP, LLJ). All articles in which IVUS was mentioned were selected. These articles were fully read, and those that met the criteria were included. Disagreements were solved by consensus. If consensus was not achieved, a third reviewer (ALR) defined the question.

Statistical analysis

The intention-to-treat meta-analysis that followed the systematic review was performed by the random-effects model of the Comprehensive Meta-Analysis software (Borenstein M, Hedges L, Higgins J, Rothstein H. Version 2.2.048, Biostat, Englewood NJ, USA 2005), with the odds ratio (OR), 95% confidence intervals and two-sided P-values calculated for each outcome. The analysis of heterogeneity between studies was estimated by the I 2 statistic.
Publication bias evaluation was performed by Duval and Tweedie’s Trim and Fill method [16]. Egger's test was also performed to analyze the impact of several factors on the size of the treatment effect [17]. The small study effect was also evaluated by cumulative analysis (from largest to smallest sample size) and by the one-study-removed method.

Results

A total of 4,247 articles in PubMed, 869 in Embase and 4,260 in Web of Knowledge databases were identified. Eight studies were selected according to the inclusion criteria (Figure 1) [1826]. After a comprehensive analysis, three studies were excluded because they used a provisional stenting technique [19, 25, 26], which is no longer performed because of its higher restenosis rate [27]. Table 1 summarizes the clinical and angiographic characteristics of the patients included in the selected studies.
Table 1
Patient characteristics
Study
DIPOL
AVID
RESIST
TULIP
OPTICUS
 
IVUS
QCA
IVUS
QCA
IVUS
QCA
IVUS
QCA
IVUS
QCA
Demographic characteristics
Patients, n
83
80
369
375
79
76
73
71
273
275
Age. years, mean ± SD
56 ± 8
54 ± 8
62 ± 12
63 ± 11
57 ± 10
56 ± 12
63 ± 10
61 ± 10
60.1 ± 10
61.5 ± 9.5
Men,%
71
73
73
68
86
93
71
72
77
78
Smoker,%
47
52
-
-
55
51
40
43
0.69
0.66
Previous MI,%
44
40
35
29
54
48
-
-
0.32
0.32
Previous CABG,%
-
-
18
20
-
-
-
-
0.03
0.04
Previous PCI,%
-
-
24
25
-
-
-
-
0.2
0.2
Diabetes mellitus.%
10
11
15
17
9
8
21
16
0.17
0.17
Dyslipidemia,%
47
40
40
44
54
52
62
61
0.61
0.67
Hypertension,%
-
-
46
45
24
26
30
27
0.48
0.52
LV ejection fraction,%, mean ± SD
52 ± 9
48 ± 10
53 ± 13
55 ± 13
51 ± 9
53 ± 13
-
-
56.5 ± 14
57.7 ± 14.3
Angiographic characteristics
Target vessel,%
- Left anterior descending artery
41
46
40
37
48
47
39
38
51
50
- Left circumflex artery
26
24
15
18
11
11
10
21
18
14
- Right coronary artery
33
30
35
32
41
42
51
41
30
35
- Left main coronary artery
-
-
0.8
0.5
-
-
-
-
-
-
Lesion length, mm, mean ± SD
N/A
N/A
13.0 ± 7.7
13.3 ± 9.2
7.7 ± 3.5
8.0 ± 4.0
27.0 ± 9
29.0 ± 10
11.9 ± 5.1
11.6 ± 5.5
Reference diameter, mm, mean ± SD
3.21 ± 0.64
3.19 ± 0.59
3.05 ± 0.64
3.00 ± 0.54
3.0 ± 0.64*
2.89 ± 0.54*
2.95 ± 0.57
2.96 ± 0.53
2.97 ± 0.53
3.01 ± 0.51
Type B2 or C ACC/AHA lesions,%
13
10
N/A
N/A
43
48
100
100
76
78
Pre-intervention
- Minimum lumen diameter, mm, mean ± SD
0.97 ± 0.33
0.95 ± 0.32
1.11 ± 0.5
1.09 ± 0.47
0.96 ± 0.37
1.02 ± 0.44
1.02 ± 0.42
0.99 ± 0.41
0.96 ± 0.35
0.99 ± 0.34
- Diameter stenosis,%, mean ± SD
69.7 ± 14.2
70.2 ± 11.4
63.4 ± 14.1
63.5 ± 14.3
65.0 ± 11.0
64.0 ± 12.0
65.0 ± 13.0
65.0 ± 10.0
67.6 ± 11.2
66.7 ± 10.1
Post-intervention
- Minimum lumen diameter, mm, mean ± SD
3.34 ± 0.55
3.06 ± 0.52
2.93 ± 0.55
2.87 ± 0.48
2.48 ± 0.43
2.46 ± 0.46
3.01 ± 0.40
2.80 ± 0.31
3.02 ± 0.49
2.91 ± 0.41
- Diameter stenosis,%, mean ± SD
3.4 ± 2.9
8.9 ± 5.4
N/A
N/A
19.0 ± 10.0
19.0 ± 9.0
12.0 ± 7.0
13.0 ± 9.0
2.8 ± 7.8
6.0 ± 8.0
* In the RESIST study, the reference diameter average was calculated. MI, myocardial infarction; CABG, coronary artery bypass graft; PCI, percutaneous coronary intervention; LV, left ventricular; ACA, American College of Cardiology; AHA, American Heart Association; IVUS, intravascular ultrasound; N/A, not applicable, QCA, Quantitative Coronary Angiography.

Qualitative study analysis

There were significant differences between the five studies included in the final analysis (Table 2). One of the current indications of IVUS-guided PCI is for patients with long lesions (greater than 15 or 25 mm) [8, 28, 29], who have been excluded from most studies [18, 20, 24]. Unlike the others, the TULIP study excluded those patients who had focal lesions (less than 20 mm in length). Every study but the AVID trial excluded patients with a current or past history of acute coronary syndrome (ACS). In the RESIST study, randomization was performed only after the intervention, which may have caused a selection bias. In the AVID trial, the IVUS analysis was only performed after implantation of the stent, excluding the initial assessment of the target lesion [8].
Table 2
Study characteristics
Study
DIPOL
AVID
RESIST
TULIP
OPTICUS
Enrolling years
2000 to 2002
1995 to 1998
1995 to 1997
1991 to 2001
1996 to 1998
Randomized
Yes
Yes
Yes
Yes
Yes
- Blinded?
Yes
Yes
N/A
N/A
Yes
- When?
Pre-intervention
Pre-intervention
Post-intervention
Pre-intervention
Pre-intervention
Intention-to-treat analysis
No
Yes
No
Yes
Yes
Exclusion criteria
- Long lesions
Yes (> 25 mm)
No
Yes (> 15 mm)
No
Yes (> 25 mm)
- Bifurcation
Yes
No
No
Yes
Yes
- Left main coronary artery
Yes
Yes
No
No
Yes
- Chronic total occlusion
Yes
Yes
Yes
Yes
No
- Recent acute coronary syndrome
Yes
No (except MI with TIMI flow grade < 3)
Yes
Yes
Yes
- Small vessels
Yes (≤ 2.75 mm)
Yes (< 2.5 mm)
Yes (< 3 mm)
Yes (< 3 mm)
Yes (< 2.5 mm)
- Others
Age < 18 and > 70 y; extensive calcification; saphenous vein graft lesions
Age < 18 y; non-covered dissection; large vessels (> 3.25 mm)
Previous CABG
Focal (< 20 mm) or ostial lesions
 
Pre-intervention IVUS
Yes
No
No
Yes
Yes
Post-intervention IVUS
Yes
Yes
Yes
Yes
Yes
PCI success criteria
Stent CSA/average CSA > 80%, complete apposition, stent CSA > 7.5 mm2
Stent CSA/distal CSA > 90%, complete apposition, no dissection
Stent CSA/average CSA > 80%
Stent MLD/average MLD > 80%, complete apposition, stent CSA ≥ distal CSA
Stenosis < 10% and MUSIC study criteria [10]
- PCI success by IVUS,%
96
63
61
89
82.2 and 56 (MUSIC)
Clinical follow-up, months
6
12
18
12
12
Angiographic follow-up, months
6*
 
6 (com USIC)
6
6
MACE
Death, nonfatal MI, repeat revascularization
Without explicit criteria
Death, repeat revascularization
Death, nonfatal MI, clinical TLR
Death, nonfatal MI, repeat revascularization
*Angiographic follow-up was left to the discretion of the operator: 87.9% (IVUS-guided group) and 83.7% (angio-guided group). CABG or repeat PCI for any reason. IVUS, interventional ultrasound; PCI, percutaneous coronary intervention; MACE, major adverse cardiovascular events; CSA, cross sectional area; MI, myocardial infarction; TIMI, thrombolysis in myocardial infarction; CABG, coronary artery bypass graft; MLD, minimum lumen diameter; clinical TLR, ischemia-driven target lesion revascularization.
The criteria for optimal stent implantation were heterogeneous. Only the OPTICUS study used the criteria proposed by the MUSIC study [10]. The majority of patients underwent angiographic assessment after six months (angiographic follow-up) [20, 22, 24]. Another difference between the studies was in the criteria used for MACE. In the RESIST study, MI was not included. In the TULIP study, the MACE criteria included death, nonfatal MI and ischemia-driven target lesion revascularization (TLR). In the AVID trial, the composition of this outcome was not explained. In the other studies, the criteria for repeat revascularization were more comprehensive and included coronary artery bypass grafting (CABG) or a repeated PCI for any reason [18, 20, 21, 24].

Heterogeneity

The heterogeneity among the studies showed intermediate values in nonfatal MI (I 2  = 48.82%) and MACE (I 2  = 57.38%). For death, no heterogeneity was observed among the studies (I 2  = 0%).

Publication bias

We also evaluated the possibility of publication bias (B0) for MACE. Egger’s Test (B0 = −3.43; 95% CI − 6.40 to −0.47, one-tailed P- value 0.02) and the trim and fill test (observed OR 0.74, 95% CI 0.49 to 1.13; two studies imputed: adjusted OR 0.93, 95% CI 0.60 to 1.44) (Figure 2) were positive, suggesting the presence of small studies effects, which can be attributable to differences in design (not detected) or to publication bias.

Meta-analysis results

A total of 1,754 patients were randomized in five studies. There was no statistically significant difference between the IVUS-guided group and the angiography-guided group (Table 3) for death (OR 1.86, 95% CI 0.88 to 3.95, P = 0.10) (Figure 3-A), nonfatal MI (OR 0.65, 95% CI 0.27 to 1.58, P = 0.35) (Figure 3-B) or MACE (OR 0.74, 95% CI 0.49 to 1.13, P = 0.16) (Figure 3-C).
Table 3
Clinical Outcomes
Study
DIPOL
AVID
RESIST
TULIP
OPTICUS
Total
 
IVUS
QCA
IVUS
QCA
IVUS
QCA
IVUS
QCA
IVUS
QCA
IVUS
QCA
Patients, n
83
80
369
375
79
76
73
71
273
275
877
877
Death, n (%)
1 (1.2)
1 (1.3)
12 (3.3)
7 (1.9)
1 (1.3)
1 (1.3)
2 (2.7)
1 (1.4)
5 (1.8)
1 (0.36)
21 (2.4)
11 (1.3)
Nonfatal MI, n (%)
1 (1.2)
4 (5)
25 (6.8)
19 (5.1)
N/A
N/A
1 (1.4)
5 (7.0)
6 (2.2)
10 (3.6)
33 (4.1) 1
38 (4.7) 1
MACE, n (%)
6 (7.2)
13 (16.2)
68 (18.4)
70 (18.7)
20 (25.3)
28 (36.8)
9 (12.3)
19 (26.8)
49 (17.9)
42 (15.3)
152 (17.3)
172 (19.6)
*The analysis of nonfatal MI excludes the RESIST Study, where this outcome was not calculated. MI, myocardial infarction; MACE, major adverse cardiovascular events; IVUS, interventional ultrasound.

Reviewing published data

In order to clarify the discrepancy in MACE results found in this analysis compared to the medical literature, the data of a previously published meta-analysis [13] were re-evaluated (Figure 4). Among the studies selected by that meta-analysis, only two were not included in the present selection because the provisional stenting technique was employed in both of them [19, 25].
A funnel plot analysis was performed along with Egger’s Test (B0 = −3.66, 95% CI − 5.54 to −1.78, one-tailed P-value = 0.002) and the trim and fill test (observed OR 0.70, 95% CI 0.50 to 0.98; three studies imputed: adjusted OR 0.89, 95% CI 0.62 to 1.27), which suggested the presence of publication bias [16, 17].
A cumulative meta-analysis by reverse order of sample size was performed. The results only became positive when the last and smallest study was included in the analysis (Figure 5). Moreover, the one-study-removed analysis showed that the removal of any one of the smaller studies gave a neutral result from the meta-analysis (Figure 6). This makes it plausible to assume that one small unpublished study with negative results would be enough to nullify the effect of that meta-analysis.

Discussion

In this rigorously conducted meta-analysis of randomized controlled trials that compared IVUS-guided PCI with angiography-guided PCI using bare metal stents, we did not find any advantage of the IVUS-guided strategy over the standard method in clinically relevant outcomes. Indeed, we found evidence of publication bias and of significant heterogeneity among the studies regarding the outcomes MI and MACE. These results diverge from the last two meta-analyses on this topic [12, 13], which included studies with provisional stenting, considered surrogate outcomes, and did not evaluate the presence of publication bias. However, they are in concordance with recently published studies of IVUS-guided PCI with drug-eluting stent implantation, which were not associated with significant clinical benefits [30, 31].

Differences between selected studies

The five selected studies have important differences that might lead to completely different outcomes in another context. For example, the exclusion of patients presenting with ACS may have led to a reduction in post-interventional adverse events [3235]. In the AVID trial, pre-interventional IVUS was not performed, which excluded an important phase of the method because one of the roles of IVUS is to assess the target lesion to help in the choice of technique and devices for the PCI [8]. Only the OPTICUS study used the MUSIC study criteria for optimal stent implantation [10], which theoretically could be associated with a lower MACE rate [36]. Angiographic follow-up was performed in most studies, which may have led to an overestimated rate of repeat revascularization, due to the oculo-stenotic reflex [37], which is the predisposition to indicate a PCI for any significant luminal obstruction, despite the presence or absence of myocardial ischemia [38]. The fact that most studies have used more comprehensive criteria for repeat revascularization may have also increased MACE rates [18, 20, 24].

Study biases

The data analysis suggested the presence of publication bias in both meta-analyses. This bias may have led to apparently positive results that could be easily modified by unpublished studies with small sample sizes. It may be harmful because it can maintain or amplify an apparent beneficial effect of the intervention [39].
Significance-chasing bias is an enticing term that refers to the clustering of the most common types of meta-analysis bias, including those in which the apparently negative results remain unpublished (study publication bias and selective outcome reporting bias), those in which negative results become positive (selective analysis reporting bias) and those in which no existing data are presented as positive (fabrication bias) [40, 41].
Selective reporting bias is the most common problem in meta-analyses. In selective outcome reporting bias, specific data with a negative result are omitted from publication. In selective analysis reporting bias, which is even more frequent, a negative result calculated from a pre-determined analysis plan is replaced by a positive result achieved through post hoc data analysis [41].
Another major problem is the potential presence of interests other than scientific truth. This matter becomes critical when the object of the meta-analysis is an industry product, as in the present study, because most of the researches are conducted or funded by manufacturers (Table 4) [42, 43]. There is a current trend towards opposing this practice [44].
Table 4
Study funding and conflicts of interest of the authors of original articles included in this meta-analysis
Trial
Industry funding
Conflicts of interest (authors)
DIPOL
None declared
N/A
AVID
None declared
Accumetrics; Baxter; BDS; Boston Scientific; Cardium; Conor Medical; Cordis; Johnson & Johnson; Medtronic; Volcano
RESIST
None declared
N/A
TULIP
Medtronic; AVE
Boston Scientific; Guidant
OPTICUS
Boston Scientific; Johnson & Johnson
N/A
N/A, not applicable.
Meta-analyses have gained prestige over time but they are still considered by some to be an ancillary method, accepted only when it corroborates the point of view of experts and of public policies [41]. They could play a fundamental role in changing (or in supporting) the evidence on relevant issues if conducted properly, with a pre-specified analysis plan and declared conflicts of interest for every study included, in addition to determining and reporting all possible biases.

Limitations

The paucity of randomized controlled trials comparing IVUS-guided PCI and angio-guided PCI and the exclusion of groups with specific lesions (long lesions, small vessels, bifurcations or left main coronary artery) may have masked a possible benefit. The same point applies to the exclusion of patients presenting with ACS, whose rate of cardiovascular events is higher, and PCI, when indicated, may even reduce mortality [3234].
The low statistical power of the present study and of the re-evaluated meta-analysis [13] is due to the presence of heterogeneity and to the possibility of study publication bias. The presence of other biases might be possible but that is even more difficult to prove.

Conclusion

The clinical benefit of IVUS-guided PCI with bare-metal stent implantation could be determined neither by the meta-analysis presented in this study nor by the re-evaluated meta-analysis. This may be explained by the paucity and heterogeneity of the studies published so far. Furthermore, both meta-analyses showed possible publication biases.
Therefore, there is no evidence so far to recommend routine IVUS-guided PCI with bare-metal stent implantation. Studies on specific subgroups and performance of a simple large randomized trial could show different results.
This research was conducted by public funding from the National Council for Scientific and Technological Development (CNPq) (CNPq Project: 559584/2009-1).
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interest

The authors declare no conflicts of interest in the preparation and in the presentation of this meta-analysis.

Authors’ contributions

LLJ participated in the design of the study, retrieved, reviewed and selected the articles from electronic and manual searches, helped to discuss the results and to draft the manuscript. MRS participated in the design of the study, performed the statistical analysis and helped to discuss the results and to draft the manuscript. LCP retrieved, reviewed and selected the articles from electronic and manual searches. SMBK participated in the design of the study and helped to retrieve articles from electronic searches, to discuss the results and to draft the manuscript. CFSA participated in the design of the study and helped to discuss the results and to draft the manuscript. ALR participated in the coordination of the study, helped to select the articles, to discuss the results and to draft the manuscript. All authors read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat Yock PG, Linker DT, Angelsen BA: Two-dimensional intravascular ultrasound: technical development and initial clinical experience. J Am Soc Echocardiogr. 1989, 2: 296-304.CrossRefPubMed Yock PG, Linker DT, Angelsen BA: Two-dimensional intravascular ultrasound: technical development and initial clinical experience. J Am Soc Echocardiogr. 1989, 2: 296-304.CrossRefPubMed
2.
Zurück zum Zitat Gussenhoven WJ, Essed CE, Frietman P, Mastik F, Lancee C, Slager C, Serruys P, Gerritsen P, Pieterman H, Bom N: Intravascular echographic assessment of vessel wall characteristics: a correlation with histology. Int J Card Imaging. 1989, 4: 105-116. 10.1007/BF01745140.CrossRefPubMed Gussenhoven WJ, Essed CE, Frietman P, Mastik F, Lancee C, Slager C, Serruys P, Gerritsen P, Pieterman H, Bom N: Intravascular echographic assessment of vessel wall characteristics: a correlation with histology. Int J Card Imaging. 1989, 4: 105-116. 10.1007/BF01745140.CrossRefPubMed
3.
Zurück zum Zitat Hodgson JM, Graham SP, Savakus AD, Dame SG, Stephens DN, Dhillon PS, Brands D, Sheehan H, Eberle MJ: Clinical percutaneous imaging of coronary anatomy using an over-the-wire ultrasound catheter system. Int J Card Imaging. 1989, 4: 187-193. 10.1007/BF01745149.CrossRefPubMed Hodgson JM, Graham SP, Savakus AD, Dame SG, Stephens DN, Dhillon PS, Brands D, Sheehan H, Eberle MJ: Clinical percutaneous imaging of coronary anatomy using an over-the-wire ultrasound catheter system. Int J Card Imaging. 1989, 4: 187-193. 10.1007/BF01745149.CrossRefPubMed
4.
Zurück zum Zitat Roelandt JR, Serruys PW, Bom N, Gussenhoven WG, Lancee CT, Ten HH: Intravascular real-time, two-dimensional echocardiography. Int J Card Imaging. 1989, 4: 63-67. 10.1007/BF01795127.CrossRefPubMed Roelandt JR, Serruys PW, Bom N, Gussenhoven WG, Lancee CT, Ten HH: Intravascular real-time, two-dimensional echocardiography. Int J Card Imaging. 1989, 4: 63-67. 10.1007/BF01795127.CrossRefPubMed
5.
Zurück zum Zitat Colombo A, Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, Gaglione A, Goldberg SL, Tobis JM: Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation. 1995, 91: 1676-1688. 10.1161/01.CIR.91.6.1676.CrossRefPubMed Colombo A, Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, Gaglione A, Goldberg SL, Tobis JM: Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation. 1995, 91: 1676-1688. 10.1161/01.CIR.91.6.1676.CrossRefPubMed
6.
Zurück zum Zitat Abizaid AS, Mintz GS, Abizaid A, Mehran R, Lansky AJ, Pichard AD, Satler LF, Wu H, Kent KM, Leon MB: One-year follow-up after intravascular ultrasound assessment of moderate left main coronary artery disease in patients with ambiguous angiograms. J Am Coll Cardiol. 1999, 34: 707-715. 10.1016/S0735-1097(99)00261-2.CrossRefPubMed Abizaid AS, Mintz GS, Abizaid A, Mehran R, Lansky AJ, Pichard AD, Satler LF, Wu H, Kent KM, Leon MB: One-year follow-up after intravascular ultrasound assessment of moderate left main coronary artery disease in patients with ambiguous angiograms. J Am Coll Cardiol. 1999, 34: 707-715. 10.1016/S0735-1097(99)00261-2.CrossRefPubMed
7.
Zurück zum Zitat Abizaid AS, Mintz GS, Mehran R, Abizaid A, Lansky AJ, Pichard AD, Satler LF, Wu H, Pappas C, Kent KM, Leon MB: Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: importance of lumen dimensions. Circulation. 1999, 100: 256-261. 10.1161/01.CIR.100.3.256.CrossRefPubMed Abizaid AS, Mintz GS, Mehran R, Abizaid A, Lansky AJ, Pichard AD, Satler LF, Wu H, Pappas C, Kent KM, Leon MB: Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: importance of lumen dimensions. Circulation. 1999, 100: 256-261. 10.1161/01.CIR.100.3.256.CrossRefPubMed
8.
Zurück zum Zitat Bourantas CV, Naka KK, Garg S, Thackray S, Papadopoulos D, Alamgir FM, Hoye A, Michalis LK: Clinical indications for intravascular ultrasound imaging. Echocardiography. 2010, 27: 1282-1290. 10.1111/j.1540-8175.2010.01259.x.CrossRefPubMed Bourantas CV, Naka KK, Garg S, Thackray S, Papadopoulos D, Alamgir FM, Hoye A, Michalis LK: Clinical indications for intravascular ultrasound imaging. Echocardiography. 2010, 27: 1282-1290. 10.1111/j.1540-8175.2010.01259.x.CrossRefPubMed
9.
Zurück zum Zitat Orford JL, Denktas AE, Williams BA, Fasseas P, Willerson JT, Berger PB, Holmes DR, PRESTO Investigators: Routine intravascular ultrasound scanning guidance of coronary stenting is not associated with improved clinical outcomes. Am Heart J. 2004, 148: 501-506. 10.1016/j.ahj.2004.03.033.CrossRefPubMed Orford JL, Denktas AE, Williams BA, Fasseas P, Willerson JT, Berger PB, Holmes DR, PRESTO Investigators: Routine intravascular ultrasound scanning guidance of coronary stenting is not associated with improved clinical outcomes. Am Heart J. 2004, 148: 501-506. 10.1016/j.ahj.2004.03.033.CrossRefPubMed
10.
Zurück zum Zitat De JP, Mudra H, Figulla H, Almagor Y, Doucet S, Penn I, Colombo A, Hamm C, Bartorelli A, Rothman M, Nobuyoshi M, Yamaguchi T, Voudris V, DiMario C, Makovski S, Hausmann D, Rowe S, Rabinovich S, Sunamura M, van Es GA: Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study). Eur Heart J. 1998, 19: 1214-1223. 10.1053/euhj.1998.1012.CrossRef De JP, Mudra H, Figulla H, Almagor Y, Doucet S, Penn I, Colombo A, Hamm C, Bartorelli A, Rothman M, Nobuyoshi M, Yamaguchi T, Voudris V, DiMario C, Makovski S, Hausmann D, Rowe S, Rabinovich S, Sunamura M, van Es GA: Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study). Eur Heart J. 1998, 19: 1214-1223. 10.1053/euhj.1998.1012.CrossRef
11.
Zurück zum Zitat Berry E, Kelly S, Hutton J, Lindsay HS, Blaxill JM, Evans JA, Connelly J, Tisch J, Walker GC, Sivananthan UM, Smith MA: Intravascular ultrasound-guided interventions in coronary artery disease: a systematic literature review, with decision-analytic modelling, of outcomes and cost-effectiveness. Health Technol Assess. 2000, 4: 1-117.PubMed Berry E, Kelly S, Hutton J, Lindsay HS, Blaxill JM, Evans JA, Connelly J, Tisch J, Walker GC, Sivananthan UM, Smith MA: Intravascular ultrasound-guided interventions in coronary artery disease: a systematic literature review, with decision-analytic modelling, of outcomes and cost-effectiveness. Health Technol Assess. 2000, 4: 1-117.PubMed
12.
Zurück zum Zitat Casella G, Klauss V, Ottani F, Siebert U, Sangiorgio P, Bracchetti D: Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting. Catheter Cardiovasc Interv. 2003, 59: 314-321. 10.1002/ccd.10537.CrossRefPubMed Casella G, Klauss V, Ottani F, Siebert U, Sangiorgio P, Bracchetti D: Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting. Catheter Cardiovasc Interv. 2003, 59: 314-321. 10.1002/ccd.10537.CrossRefPubMed
13.
Zurück zum Zitat Parise H, Maehara A, Stone GW, Leon MB, Mintz GS: Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in pre-drug-eluting stent era. Am J Cardiol. 2011, 107: 374-382. 10.1016/j.amjcard.2010.09.030.CrossRefPubMed Parise H, Maehara A, Stone GW, Leon MB, Mintz GS: Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in pre-drug-eluting stent era. Am J Cardiol. 2011, 107: 374-382. 10.1016/j.amjcard.2010.09.030.CrossRefPubMed
14.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J, Altman DG: Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ. 2009, 339: b2535-10.1136/bmj.b2535.CrossRefPubMedPubMedCentral Moher D, Liberati A, Tetzlaff J, Altman DG: Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ. 2009, 339: b2535-10.1136/bmj.b2535.CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat la Cour JL, Brok J, Gotzsche PC: Inconsistent reporting of surrogate outcomes in randomised clinical trials: cohort study. BMJ. 2010, 341: c3653-10.1136/bmj.c3653.CrossRefPubMedPubMedCentral la Cour JL, Brok J, Gotzsche PC: Inconsistent reporting of surrogate outcomes in randomised clinical trials: cohort study. BMJ. 2010, 341: c3653-10.1136/bmj.c3653.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Sutton AJ, Duval SJ, Tweedie RL, Abrams KR, Jones DR: Empirical assessment of effect of publication bias on meta-analyses. BMJ. 2000, 320: 1574-1577. 10.1136/bmj.320.7249.1574.CrossRefPubMedPubMedCentral Sutton AJ, Duval SJ, Tweedie RL, Abrams KR, Jones DR: Empirical assessment of effect of publication bias on meta-analyses. BMJ. 2000, 320: 1574-1577. 10.1136/bmj.320.7249.1574.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Gil RJ, Pawlowski T, Dudek D, Horszczaruk G, Zmudka K, Lesiak M, Witkowski A, Ochała A, Kubica J, Investigators of Direct Stenting vs Optimal Angioplasty Trial (DIPOL): Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound. The multicenter, randomized trial results. Am Heart J. 2007, 154: 669-675. 10.1016/j.ahj.2007.06.017.CrossRefPubMed Gil RJ, Pawlowski T, Dudek D, Horszczaruk G, Zmudka K, Lesiak M, Witkowski A, Ochała A, Kubica J, Investigators of Direct Stenting vs Optimal Angioplasty Trial (DIPOL): Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound. The multicenter, randomized trial results. Am Heart J. 2007, 154: 669-675. 10.1016/j.ahj.2007.06.017.CrossRefPubMed
19.
Zurück zum Zitat Gaster AL, Slothuus SU, Larsen J, Korsholm L, Von BC, Jensen S, Thayssen P, Pedersen KE, Haghfelt TH: Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study. Heart. 2003, 89: 1043-1049. 10.1136/heart.89.9.1043.CrossRefPubMedPubMedCentral Gaster AL, Slothuus SU, Larsen J, Korsholm L, Von BC, Jensen S, Thayssen P, Pedersen KE, Haghfelt TH: Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study. Heart. 2003, 89: 1043-1049. 10.1136/heart.89.9.1043.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Schiele F, Meneveau N, Vuillemenot A, Zhang DD, Gupta S, Mercier M, Danchin N, Bertrand B, Bassand JP: Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: a multicenter, randomized study comparing two strategies–with and without intravascular ultrasound guidance. RESIST Study Group. REStenosis after Ivus guided STenting. J Am Coll Cardiol. 1998, 32: 320-328. 10.1016/S0735-1097(98)00249-6.CrossRefPubMed Schiele F, Meneveau N, Vuillemenot A, Zhang DD, Gupta S, Mercier M, Danchin N, Bertrand B, Bassand JP: Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: a multicenter, randomized study comparing two strategies–with and without intravascular ultrasound guidance. RESIST Study Group. REStenosis after Ivus guided STenting. J Am Coll Cardiol. 1998, 32: 320-328. 10.1016/S0735-1097(98)00249-6.CrossRefPubMed
21.
Zurück zum Zitat Schiele F, Meneveau N, Seronde MF, Caulfield F, Pisa B, Arveux P, Danchin N, Bassand JP: Medical costs of intravascular ultrasound optimization of stent deployment. Results of the multicenter randomized 'REStenosis after Intravascular ultrasound STenting' (RESIST) study. Int J Cardiovasc Intervent. 2000, 3: 207-213.CrossRefPubMed Schiele F, Meneveau N, Seronde MF, Caulfield F, Pisa B, Arveux P, Danchin N, Bassand JP: Medical costs of intravascular ultrasound optimization of stent deployment. Results of the multicenter randomized 'REStenosis after Intravascular ultrasound STenting' (RESIST) study. Int J Cardiovasc Intervent. 2000, 3: 207-213.CrossRefPubMed
22.
Zurück zum Zitat Oemrawsingh PV, Mintz GS, Schalij MJ, Zwinderman AH, Jukema JW, van der Wall EE: Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study). Circulation. 2003, 107: 62-67. 10.1161/01.CIR.0000043240.87526.3F.CrossRefPubMed Oemrawsingh PV, Mintz GS, Schalij MJ, Zwinderman AH, Jukema JW, van der Wall EE: Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study). Circulation. 2003, 107: 62-67. 10.1161/01.CIR.0000043240.87526.3F.CrossRefPubMed
23.
Zurück zum Zitat Russo RJ, Silva PD, Teirstein PS, Attubato MJ, Davidson CJ, DeFranco AC, Fitzgerald PJ, Goldberg SL, Hermiller JB, Leon MB, Ling FS, Lucisano JE, Schatz RA, Wong SC, Weissman NJ, Zientek DM, AVID Investigators: A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial). Circ Cardiovasc Interv. 2009, 2: 113-123. 10.1161/CIRCINTERVENTIONS.108.778647.CrossRefPubMed Russo RJ, Silva PD, Teirstein PS, Attubato MJ, Davidson CJ, DeFranco AC, Fitzgerald PJ, Goldberg SL, Hermiller JB, Leon MB, Ling FS, Lucisano JE, Schatz RA, Wong SC, Weissman NJ, Zientek DM, AVID Investigators: A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial). Circ Cardiovasc Interv. 2009, 2: 113-123. 10.1161/CIRCINTERVENTIONS.108.778647.CrossRefPubMed
24.
Zurück zum Zitat Mudra H, Di MC, De JP, Figulla HR, Macaya C, Zahn R, Wennerblom B, Rutsch W, Voudris V, Regar E, Henneke KH, Schächinger V, Zeiher A, OPTICUS (OPTimization with ICUS to reduce stent restenosis) Study Investigators: Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study). Circulation. 2001, 104: 1343-1349. 10.1161/hc3701.096064.CrossRefPubMed Mudra H, Di MC, De JP, Figulla HR, Macaya C, Zahn R, Wennerblom B, Rutsch W, Voudris V, Regar E, Henneke KH, Schächinger V, Zeiher A, OPTICUS (OPTimization with ICUS to reduce stent restenosis) Study Investigators: Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study). Circulation. 2001, 104: 1343-1349. 10.1161/hc3701.096064.CrossRefPubMed
25.
Zurück zum Zitat Frey AW, Hodgson JM, Muller C, Bestehorn HP, Roskamm H: Ultrasound-guided strategy for provisional stenting with focal balloon combination catheter: results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial. Circulation. 2000, 102: 2497-2502. 10.1161/01.CIR.102.20.2497.CrossRefPubMed Frey AW, Hodgson JM, Muller C, Bestehorn HP, Roskamm H: Ultrasound-guided strategy for provisional stenting with focal balloon combination catheter: results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial. Circulation. 2000, 102: 2497-2502. 10.1161/01.CIR.102.20.2497.CrossRefPubMed
26.
Zurück zum Zitat Mueller C, Hodgson JM, Schindler C, Perruchoud AP, Roskamm H, Buettner HJ: Cost-effectiveness of intracoronary ultrasound for percutaneous coronary interventions. Am J Cardiol. 2003, 91: 143-147. 10.1016/S0002-9149(02)03099-0.CrossRefPubMed Mueller C, Hodgson JM, Schindler C, Perruchoud AP, Roskamm H, Buettner HJ: Cost-effectiveness of intracoronary ultrasound for percutaneous coronary interventions. Am J Cardiol. 2003, 91: 143-147. 10.1016/S0002-9149(02)03099-0.CrossRefPubMed
27.
Zurück zum Zitat Al SJ, Holmes DR, Salam AM, Lennon R, Berger PB: Impact of coronary artery stents on mortality and nonfatal myocardial infarction: meta-analysis of randomized trials comparing a strategy of routine stenting with that of balloon angioplasty. Am Heart J. 2004, 147: 815-822. 10.1016/j.ahj.2003.11.025.CrossRef Al SJ, Holmes DR, Salam AM, Lennon R, Berger PB: Impact of coronary artery stents on mortality and nonfatal myocardial infarction: meta-analysis of randomized trials comparing a strategy of routine stenting with that of balloon angioplasty. Am Heart J. 2004, 147: 815-822. 10.1016/j.ahj.2003.11.025.CrossRef
28.
Zurück zum Zitat Colombo A, De GJ, Moussa I, Kobayashi Y, Karvouni E, Di MC, Di Mario C, Albiero R, Finci L, Moses J: Intravascular ultrasound-guided percutaneous transluminal coronary angioplasty with provisional spot stenting for treatment of long coronary lesions. J Am Coll Cardiol. 2001, 38: 1427-1433. 10.1016/S0735-1097(01)01557-1.CrossRefPubMed Colombo A, De GJ, Moussa I, Kobayashi Y, Karvouni E, Di MC, Di Mario C, Albiero R, Finci L, Moses J: Intravascular ultrasound-guided percutaneous transluminal coronary angioplasty with provisional spot stenting for treatment of long coronary lesions. J Am Coll Cardiol. 2001, 38: 1427-1433. 10.1016/S0735-1097(01)01557-1.CrossRefPubMed
29.
Zurück zum Zitat Orford JL, Lerman A, Holmes DR: Routine intravascular ultrasound guidance of percutaneous coronary intervention: a critical reappraisal. J Am Coll Cardiol. 2004, 43: 1335-1342. 10.1016/j.jacc.2003.12.035.CrossRefPubMed Orford JL, Lerman A, Holmes DR: Routine intravascular ultrasound guidance of percutaneous coronary intervention: a critical reappraisal. J Am Coll Cardiol. 2004, 43: 1335-1342. 10.1016/j.jacc.2003.12.035.CrossRefPubMed
30.
Zurück zum Zitat Biondi-Zoccai G, Sheiban I, Romagnoli E, De SS, Tamburino C, Colombo A, Burzotta F, Presbitero P, Bolognese L, Paloscia L, Rubino P, Sardella G, Briguori C, Niccoli L, Franco G, Di Girolamo D, Piatti L, Greco C, Capodanno D, Sangiorgi G: Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4,314-patient registry. Clin Res Cardiol. 2011, 100: 1021-1028. 10.1007/s00392-011-0336-x.CrossRefPubMed Biondi-Zoccai G, Sheiban I, Romagnoli E, De SS, Tamburino C, Colombo A, Burzotta F, Presbitero P, Bolognese L, Paloscia L, Rubino P, Sardella G, Briguori C, Niccoli L, Franco G, Di Girolamo D, Piatti L, Greco C, Capodanno D, Sangiorgi G: Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4,314-patient registry. Clin Res Cardiol. 2011, 100: 1021-1028. 10.1007/s00392-011-0336-x.CrossRefPubMed
31.
Zurück zum Zitat Jakabcin J, Spacek R, Bystron M, Kvasnak M, Jager J, Veselka J, Kala P, Cervinka P: Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS. Catheter Cardiovasc Interv. 2010, 75: 578-583.CrossRefPubMed Jakabcin J, Spacek R, Bystron M, Kvasnak M, Jager J, Veselka J, Kala P, Cervinka P: Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS. Catheter Cardiovasc Interv. 2010, 75: 578-583.CrossRefPubMed
32.
Zurück zum Zitat Lagerqvist B, Husted S, Kontny F, Stahle E, Swahn E, Wallentin L: 5-year outcomes in the FRISC-II randomised trial of an invasive versus a non-invasive strategy in non-ST-elevation acute coronary syndrome: a follow-up study. Lancet. 2006, 368: 998-1004. 10.1016/S0140-6736(06)69416-6.CrossRefPubMed Lagerqvist B, Husted S, Kontny F, Stahle E, Swahn E, Wallentin L: 5-year outcomes in the FRISC-II randomised trial of an invasive versus a non-invasive strategy in non-ST-elevation acute coronary syndrome: a follow-up study. Lancet. 2006, 368: 998-1004. 10.1016/S0140-6736(06)69416-6.CrossRefPubMed
33.
Zurück zum Zitat Fox KA, Poole-Wilson PA, Henderson RA, Clayton TC, Chamberlain DA, Shaw TR, Wheatley DJ, Pocock SJ, Randomized Intervention Trial of unstable Angina Investigators: Interventional versus conservative treatment for patients with unstable angina or non-ST-elevation myocardial infarction: the British Heart Foundation RITA 3 randomised trial. Randomized Intervention Trial of unstable Angina. Lancet. 2002, 360: 743-751. 10.1016/S0140-6736(02)09894-X.CrossRefPubMed Fox KA, Poole-Wilson PA, Henderson RA, Clayton TC, Chamberlain DA, Shaw TR, Wheatley DJ, Pocock SJ, Randomized Intervention Trial of unstable Angina Investigators: Interventional versus conservative treatment for patients with unstable angina or non-ST-elevation myocardial infarction: the British Heart Foundation RITA 3 randomised trial. Randomized Intervention Trial of unstable Angina. Lancet. 2002, 360: 743-751. 10.1016/S0140-6736(02)09894-X.CrossRefPubMed
34.
Zurück zum Zitat Fox KA, Clayton TC, Damman P, Pocock SJ, de Winter RJ, Tijssen JG, Lagerqvist B, Wallentin L, FIR Collaboration: Long-term outcome of a routine versus selective invasive strategy in patients with non-ST-segment elevation acute coronary syndrome a meta-analysis of individual patient data. J Am Coll Cardiol. 2010, 55: 2435-2445. 10.1016/j.jacc.2010.03.007.CrossRefPubMed Fox KA, Clayton TC, Damman P, Pocock SJ, de Winter RJ, Tijssen JG, Lagerqvist B, Wallentin L, FIR Collaboration: Long-term outcome of a routine versus selective invasive strategy in patients with non-ST-segment elevation acute coronary syndrome a meta-analysis of individual patient data. J Am Coll Cardiol. 2010, 55: 2435-2445. 10.1016/j.jacc.2010.03.007.CrossRefPubMed
35.
Zurück zum Zitat Boden WE, O'Rourke RA, Teo KK, Hartigan PM, Maron DJ, Kostuk WJ, Knudtson M, Dada M, Casperson P, Harris CL, Chaitman BR, Shaw L, Gosselin G, Nawaz S, Title LM, Gau G, Blaustein AS, Booth DC, Bates ER, Spertus JA, Berman DS, Mancini GB, Weintraub WS, COURAGE Trial Research Group: Optimal medical therapy with or without PCI for stable coronary disease. N Engl J Med. 2007, 356: 1503-1516. 10.1056/NEJMoa070829.CrossRefPubMed Boden WE, O'Rourke RA, Teo KK, Hartigan PM, Maron DJ, Kostuk WJ, Knudtson M, Dada M, Casperson P, Harris CL, Chaitman BR, Shaw L, Gosselin G, Nawaz S, Title LM, Gau G, Blaustein AS, Booth DC, Bates ER, Spertus JA, Berman DS, Mancini GB, Weintraub WS, COURAGE Trial Research Group: Optimal medical therapy with or without PCI for stable coronary disease. N Engl J Med. 2007, 356: 1503-1516. 10.1056/NEJMoa070829.CrossRefPubMed
36.
Zurück zum Zitat Serruys PW, Kay IP, Disco C, Deshpande NV, de Feyter PJ: Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months: results of a meta-analysis of the BElgian NEtherlands Stent study (BENESTENT) I, BENESTENT II Pilot. BENESTENT II and MUSIC trials. Multicenter Ultrasound Stent In Coronaries. J Am Coll Cardiol. 1999, 34: 1067-1074. 10.1016/S0735-1097(99)00308-3.CrossRefPubMed Serruys PW, Kay IP, Disco C, Deshpande NV, de Feyter PJ: Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months: results of a meta-analysis of the BElgian NEtherlands Stent study (BENESTENT) I, BENESTENT II Pilot. BENESTENT II and MUSIC trials. Multicenter Ultrasound Stent In Coronaries. J Am Coll Cardiol. 1999, 34: 1067-1074. 10.1016/S0735-1097(99)00308-3.CrossRefPubMed
37.
Zurück zum Zitat Uchida T, Popma J, Stone GW, Ellis SG, Turco MA, Ormiston JA, Muramatsu T, Nakamura M, Nanto S, Yokoi H, Baim DS: The clinical impact of routine angiographic follow-up in randomized trials of drug-eluting stents: a critical assessment of "oculostenotic" reintervention in patients with intermediate lesions. JACC Cardiovasc Interv. 2010, 3: 403-411. 10.1016/j.jcin.2010.01.010.CrossRefPubMed Uchida T, Popma J, Stone GW, Ellis SG, Turco MA, Ormiston JA, Muramatsu T, Nakamura M, Nanto S, Yokoi H, Baim DS: The clinical impact of routine angiographic follow-up in randomized trials of drug-eluting stents: a critical assessment of "oculostenotic" reintervention in patients with intermediate lesions. JACC Cardiovasc Interv. 2010, 3: 403-411. 10.1016/j.jcin.2010.01.010.CrossRefPubMed
38.
Zurück zum Zitat Topol EJ: Coronary angioplasty for acute myocardial infarction. Ann Intern Med. 1988, 109: 970-980.CrossRefPubMed Topol EJ: Coronary angioplasty for acute myocardial infarction. Ann Intern Med. 1988, 109: 970-980.CrossRefPubMed
39.
Zurück zum Zitat Vaitkus PT, Brar C: N-acetylcysteine in the prevention of contrast-induced nephropathy: publication bias perpetuated by meta-analyses. Am Heart J. 2007, 153: 275-280. 10.1016/j.ahj.2006.09.014.CrossRefPubMed Vaitkus PT, Brar C: N-acetylcysteine in the prevention of contrast-induced nephropathy: publication bias perpetuated by meta-analyses. Am Heart J. 2007, 153: 275-280. 10.1016/j.ahj.2006.09.014.CrossRefPubMed
40.
Zurück zum Zitat Dawn AG, Balkrishnan R, Feldman SR: Systematic selection bias: a cause of dramatic errors in the inference of treatment effectiveness. J Dermatolog Treat. 2008, 19: 68-71. 10.1080/09546630701870780.CrossRefPubMed Dawn AG, Balkrishnan R, Feldman SR: Systematic selection bias: a cause of dramatic errors in the inference of treatment effectiveness. J Dermatolog Treat. 2008, 19: 68-71. 10.1080/09546630701870780.CrossRefPubMed
41.
Zurück zum Zitat Ioannidis JP: Meta-research: The art of getting it wrong. Res Syn Meth. 2010, 1: 169-184. 10.1002/jrsm.19.CrossRef Ioannidis JP: Meta-research: The art of getting it wrong. Res Syn Meth. 2010, 1: 169-184. 10.1002/jrsm.19.CrossRef
42.
Zurück zum Zitat Roseman M, Milette K, Bero LA, Coyne JC, Lexchin J, Turner EH, Thombs BD: Reporting of conflicts of interest in meta-analyses of trials of pharmacological treatments. JAMA. 2011, 305: 1008-1017. 10.1001/jama.2011.257.CrossRefPubMed Roseman M, Milette K, Bero LA, Coyne JC, Lexchin J, Turner EH, Thombs BD: Reporting of conflicts of interest in meta-analyses of trials of pharmacological treatments. JAMA. 2011, 305: 1008-1017. 10.1001/jama.2011.257.CrossRefPubMed
43.
44.
Zurück zum Zitat Jorgensen AW, Maric KL, Tendal B, Faurschou A, Gotzsche PC: Industry-supported meta-analyses compared with meta-analyses with non-profit or no support: differences in methodological quality and conclusions. BMC Med Res Methodol. 2008, 8: 60-10.1186/1471-2288-8-60.CrossRefPubMedPubMedCentral Jorgensen AW, Maric KL, Tendal B, Faurschou A, Gotzsche PC: Industry-supported meta-analyses compared with meta-analyses with non-profit or no support: differences in methodological quality and conclusions. BMC Med Res Methodol. 2008, 8: 60-10.1186/1471-2288-8-60.CrossRefPubMedPubMedCentral
Metadaten
Titel
Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials
verfasst von
Lucas Lodi-Junqueira
Marcos Roberto de Sousa
Leonardo Carvalho da Paixão
Silvana Márcia Bruschi Kelles
Carlos Faria Santos Amaral
Antonio L Ribeiro
Publikationsdatum
01.12.2012
Verlag
BioMed Central
Erschienen in
Systematic Reviews / Ausgabe 1/2012
Elektronische ISSN: 2046-4053
DOI
https://doi.org/10.1186/2046-4053-1-42

Weitere Artikel der Ausgabe 1/2012

Systematic Reviews 1/2012 Zur Ausgabe