Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 3/2019

08.11.2018 | Original Article • PELVIS - FRACTURES

Early clinical and radiological outcomes for the Taperloc Complete Microplasty stem

verfasst von: Xavier Gallart, Jenaro A. Fernández-Valencia, Gina Ríos, Guillem Bori, Josep Riba, Ernesto Muñoz-Mahamud, Andres Combalía

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

The use of short stem designs in total hip arthroplasty is not a new concept, but its popularity has increased as a bone-sparing alternative to traditional stems. This study analyzed the midterm clinical and radiological results of the Taperloc Complete Microplasty stem (Zimmer Biomet® Warsaw, IN, USA). A total of 32 patients (20 men and 12 women) were retrospectively documented and received 40 stems (eight bilateral). The median patient age was 50 years (interquartile range 43–58) at the time of surgery. The median follow-up was 36.5 months (interquartile range 26.75–50.25). Indication for total hip arthroplasty was osteoarthritis (62.5% of patients), avascular necrosis (25%), and developmental dysplasia of the hip (12.5%). The Merle d’Aubigné score improved from a mean 11.5 preoperatively to a mean 17.5 at the latest follow-up. During X-ray assessment, we observed one subsidence of the stem (3 mm) and four cases of varus malalignment without clinical consequences. No cases of osteolysis were reported, and no stems were revised. According to our results, this short tapered stem shows a good early-term outcome. Prospective results and a longer follow-up are needed to assess the long-term survival of this stem fully.
Literatur
1.
Zurück zum Zitat Castelli CC, Rizzi L (2014) Short stems in total hip replacement: current status and future. Hip Int 24(Suppl 10):S25–S28CrossRefPubMed Castelli CC, Rizzi L (2014) Short stems in total hip replacement: current status and future. Hip Int 24(Suppl 10):S25–S28CrossRefPubMed
2.
Zurück zum Zitat Hossain F, Konan S, Volpin A, Haddad FS (2017) Early performance-based and patient-reported outcomes of a contemporary taper fit bone-conserving short stem femoral component in total hip arthroplasty. Bone Joint J 99-B(4 Suppl B):49–55CrossRefPubMed Hossain F, Konan S, Volpin A, Haddad FS (2017) Early performance-based and patient-reported outcomes of a contemporary taper fit bone-conserving short stem femoral component in total hip arthroplasty. Bone Joint J 99-B(4 Suppl B):49–55CrossRefPubMed
3.
Zurück zum Zitat Small SR, Hensley SE, Cook PL, Stevens RA, Rogge RD, Meding JB, Berend ME (2017) Characterization of femoral component initial stability and cortical strain in a reduced stem-length design. J Arthroplasty 32(2):601–609CrossRefPubMed Small SR, Hensley SE, Cook PL, Stevens RA, Rogge RD, Meding JB, Berend ME (2017) Characterization of femoral component initial stability and cortical strain in a reduced stem-length design. J Arthroplasty 32(2):601–609CrossRefPubMed
4.
Zurück zum Zitat van Oldenrijk J, Molleman J, Klaver M, Poolman RW, Haverkamp D (2014) Revision rate after short-stem total hip arthroplasty: a systematic review of 49 studies. Acta Orthop 85(3):250–258CrossRefPubMedPubMedCentral van Oldenrijk J, Molleman J, Klaver M, Poolman RW, Haverkamp D (2014) Revision rate after short-stem total hip arthroplasty: a systematic review of 49 studies. Acta Orthop 85(3):250–258CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Khanuja HS, Banerjee S, Jain D, Pivec R, Mont MA (2014) Short bone-conserving stems in cementless hip arthroplasty. J Bone Joint Surg Am 96(20):1742–1752CrossRefPubMed Khanuja HS, Banerjee S, Jain D, Pivec R, Mont MA (2014) Short bone-conserving stems in cementless hip arthroplasty. J Bone Joint Surg Am 96(20):1742–1752CrossRefPubMed
6.
Zurück zum Zitat Fernández-Valencia JA, Gallart X, Pomenta V, Angulo S, Bori G, Riba J, Combalía A (2016) Revision of a cementless well fixed short stem, integrated with femoral perforation. Int J Adv Jt Reconstr 3(2):24–27 Fernández-Valencia JA, Gallart X, Pomenta V, Angulo S, Bori G, Riba J, Combalía A (2016) Revision of a cementless well fixed short stem, integrated with femoral perforation. Int J Adv Jt Reconstr 3(2):24–27
7.
Zurück zum Zitat McLaughlin JR, Lee KR (2006) The outcome of total hip replacement in obese and non-obese patients at 10- to 18-years. J Bone Joint Surg Br 88(10):1286–1292CrossRefPubMed McLaughlin JR, Lee KR (2006) The outcome of total hip replacement in obese and non-obese patients at 10- to 18-years. J Bone Joint Surg Br 88(10):1286–1292CrossRefPubMed
9.
Zurück zum Zitat Molli RG, Lombardi AV Jr, Berend KR, Adams JB, Sneller MA (2012) A short tapered stem reduces intraoperative complications in primary total hip arthroplasty. Clin Orthop Relat Res 470(2):450–461CrossRefPubMed Molli RG, Lombardi AV Jr, Berend KR, Adams JB, Sneller MA (2012) A short tapered stem reduces intraoperative complications in primary total hip arthroplasty. Clin Orthop Relat Res 470(2):450–461CrossRefPubMed
10.
Zurück zum Zitat Lombardi AV Jr, Manocchio AG, Berend KR, Morris MJ, Adams JB (2018) Early experience with a short, tapered titanium porous plasma sprayed stem with updated design. Surg Technol Int 32:233–238PubMed Lombardi AV Jr, Manocchio AG, Berend KR, Morris MJ, Adams JB (2018) Early experience with a short, tapered titanium porous plasma sprayed stem with updated design. Surg Technol Int 32:233–238PubMed
11.
Zurück zum Zitat Gallart X, Daccach JJ, Fernández-Valencia JÁ, García S, Bori G, Rios J, Riba J (2012) Study of the consistency of a system for preoperative planning digital in total arthroplasty of the hip. Rev Esp Cir Ortop Traumatol 56(6):471–477PubMed Gallart X, Daccach JJ, Fernández-Valencia JÁ, García S, Bori G, Rios J, Riba J (2012) Study of the consistency of a system for preoperative planning digital in total arthroplasty of the hip. Rev Esp Cir Ortop Traumatol 56(6):471–477PubMed
12.
Zurück zum Zitat Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242CrossRefPubMed Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242CrossRefPubMed
13.
Zurück zum Zitat Khalily C, Lester DK (2002) Results of a tapered cementless femoral stem implanted in varus. J Arthroplasty 17(4):463–466CrossRefPubMed Khalily C, Lester DK (2002) Results of a tapered cementless femoral stem implanted in varus. J Arthroplasty 17(4):463–466CrossRefPubMed
14.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27 Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27
15.
Zurück zum Zitat Engh CA, Bobyn JD, Glassman AH (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69(1):45–55CrossRefPubMed Engh CA, Bobyn JD, Glassman AH (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69(1):45–55CrossRefPubMed
16.
Zurück zum Zitat Martell JM, Pierson RH 3rd, Jacobs JJ, Rosenberg AG, Maley M, Galante JO (1993) Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg Am 75(4):554–571CrossRefPubMed Martell JM, Pierson RH 3rd, Jacobs JJ, Rosenberg AG, Maley M, Galante JO (1993) Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg Am 75(4):554–571CrossRefPubMed
17.
Zurück zum Zitat McLawhorn AS, De Martino I, Fehring KA, Sculco PK (2016) Social media and your practice: navigating the surgeon-patient relationship. Curr Rev Musculoskelet Med 9(4):487–495CrossRefPubMedPubMedCentral McLawhorn AS, De Martino I, Fehring KA, Sculco PK (2016) Social media and your practice: navigating the surgeon-patient relationship. Curr Rev Musculoskelet Med 9(4):487–495CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Banerjee S, Pivec R, Issa K, Harwin SF, Mont MA, Khanuja HS (2013) Outcomes of short stems in total hip arthroplasty. Orthopedics 36(9):700–707CrossRefPubMed Banerjee S, Pivec R, Issa K, Harwin SF, Mont MA, Khanuja HS (2013) Outcomes of short stems in total hip arthroplasty. Orthopedics 36(9):700–707CrossRefPubMed
19.
Zurück zum Zitat Hambright D, Hellman M, Barrack R (2018) Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty. Bone Joint J 100-B(1 Supple A):36–43CrossRefPubMedPubMedCentral Hambright D, Hellman M, Barrack R (2018) Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty. Bone Joint J 100-B(1 Supple A):36–43CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Yan SG, Li D, Yin S, Hua X, Tang J, Schmidutz F (2017) Periprosthetic bone remodeling of short cementless femoral stems in primary total hip arthroplasty: a systematic review and meta-analysis of randomized-controlled trials. Medicine (Baltimore) 96(47):e8806CrossRef Yan SG, Li D, Yin S, Hua X, Tang J, Schmidutz F (2017) Periprosthetic bone remodeling of short cementless femoral stems in primary total hip arthroplasty: a systematic review and meta-analysis of randomized-controlled trials. Medicine (Baltimore) 96(47):e8806CrossRef
21.
Zurück zum Zitat Ghera S, Pavan L (2009) The DePuy Proxima hip: a short stem for total hip arthroplasty. Early experience and technical considerations. Hip Int 19(3):215–220CrossRefPubMed Ghera S, Pavan L (2009) The DePuy Proxima hip: a short stem for total hip arthroplasty. Early experience and technical considerations. Hip Int 19(3):215–220CrossRefPubMed
22.
Zurück zum Zitat Engh CA, Bobyn JD (1998) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res 231:7–28 Engh CA, Bobyn JD (1998) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res 231:7–28
23.
Zurück zum Zitat Yan SG, Weber P, Steinbrück A, Hua X, Jansson V, Schmidutz F (2018) Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review. Int Orthop 42(9):2077–2086CrossRefPubMed Yan SG, Weber P, Steinbrück A, Hua X, Jansson V, Schmidutz F (2018) Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review. Int Orthop 42(9):2077–2086CrossRefPubMed
Metadaten
Titel
Early clinical and radiological outcomes for the Taperloc Complete Microplasty stem
verfasst von
Xavier Gallart
Jenaro A. Fernández-Valencia
Gina Ríos
Guillem Bori
Josep Riba
Ernesto Muñoz-Mahamud
Andres Combalía
Publikationsdatum
08.11.2018
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 3/2019
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-018-2341-5

Weitere Artikel der Ausgabe 3/2019

European Journal of Orthopaedic Surgery & Traumatology 3/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.