Open Access 05.11.2019 | Original Article

Effect of ozone and diode laser (635 nm) in reducing orthodontic pain in the maxillary arch—a randomized clinical controlled trial

verfasst von: Jacek Matys, Elżbieta Jaszczak, Rafał Flieger, Katarzyna Kostrzewska-Kaminiarz, Kinga Grzech-Leśniak, Marzena Dominiak

Erschienen in: Lasers in Medical Science | Ausgabe 2/2020

Abstract

The effect of ozone, diode laser irradiation, and presence of teeth crowding/spacing on pain perception in orthodontic patient was tested. Overall, 76 patients [55 women and 21 men; age 35.1(6.4) years] who met the inclusion criteria participated in the study. Immediately after fixed orthodontic appliance placement, the patients were exposed to a pain relief treatment (one single session) using either 635-nm diode laser (SmartM, Lasotronix, Warsaw, Poland) or ozone therapy (OzoneDTA, Apoza, New Taipei City, Taiwan) by placing the handpieces in the area of each teeth apex and interdental papillae, from the maxillary right first molar to the maxillary left first molar. Subjects were divided into three groups: control group (G1, n = 26), ozone (G2, n = 26, exposed to ozone therapy, generator probe type 3, working time per point 5 s, 23 points, application time 1 min and 55 s), and laser group (G3, n = 25, exposed to continuous mode diode laser, 400 mW, handpiece diameter 8 mm, spot area 0.5024 cm2, power density per second 1.59 W/cm2, dose 2 J per point, time: 5 s per point, 23 points, total energy per session 46 J, application time 1 min and 55 s). The level of teeth crowding was assessed using the Lundstrom indicator. The patients received a questionnaire for pain assessment (the Numeric Rating Scale, NRS-11, grade level 0–10) and recorded at 7 time points (1 h, 6 h, and 1, 2, 3, 4, and 5 days ) after the fixed orthodontic appliance placement. The mean pain values for the diode laser, ozone, and control group were 3.6 (1.31) (95% CI, 2.95–4.25), 5.25 (3.37) (95% CI, 3.52–6.98), and 5.75 (2.40) (95% CI, 4.69–6.81), respectively. We observed lower pain values in the diode laser group compared to the control group (p = 0.0237). The use of ozone in this study did not result in significant pain reduction in comparison to control (p = 0.8040) and laser groups (p = 0.1029). There were no differences in pain perception between patients with crowded teeth and non-crowded teeth in each group (G1, p = 0.66, G2, p = 0.86, G3, p = 0.24). The use of 635-nm diode laser led to decreased pain perception; however, ozone and presence of teeth crowding/spacing did not affect the pain perception in orthodontic patients during the first 5 days after the fixed orthodontic appliance placement.
Hinweise

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

The most frequent side effects after fixed orthodontics appliances placement are pain, discomfort, and sensitivity [15]. The range of 87 to 95% patients complains about pain after application of orthodontic forces, particularly during the first 24 h, whereas 39 to 49% of them experience discomfort at every stage of treatment or when taking off orthodontics appliances [16]. Pain is a common reason which discourages patients from receiving orthodontic treatment [13, 7]. Patients’ age, pain threshold, motivation, negative dental experiences, and magnitude of orthodontic force are responsible for feeling pain [7]. Discomfort usually begins 2 to 4 h after the application of force and increases during 24 h and gradually disappears in the next 7 days [3, 810]. The pain from increased pressure results in ischemia, inflammation, and edema in the squeezed periodontal ligament (PDL) [11].
There are pharmacological and non-pharmacological methods of pain relief during orthodontic treatment. The most commonly prescribed painkillers in orthodontics are non-steroidal anti-inflammatory drugs (NSAIDs). They were considered the most effective form of pain relief [8]. Unfortunately, they have a lot of side effects, such as gastrointestinal discomfort, thrombocytopenia, skin rashes, hypertension, and headaches [12].
Non-pharmacological methods of relieving pain caused by orthodontic forces include biting wafers, laser therapy, and ozone therapy [13, 14]. Ozone is a gas which has bactericidal, virucidal, and fungicidal properties [15, 16].
A fundamental effect of ozone is improved oxygenation of cells. Furthermore, ozone plasma application activates blood circulation, increases hemoglobin concentration, enhances diapedesis and phagocytosis during inflammatory response, and stimulates all antimicrobial biologic reactions [17]. The reaction of fatty acid peroxidation increases the elasticity of the erythrocyte cell membrane. Thanks to this, cells pass more easily through the capillaries, which significantly improves the metabolism of tissues [17].
The wide range of laser employment in orthodontics includes, e.g., soft tissue surgery [18, 19], hard tissue surgery [20], orthodontic mini-implants insertion [21], accelerating of tooth movement [20], and bracket debonding [22]. Low-level laser therapy (LLLT) is adopted for the relief of pain in orthodontic treatment [23]. The mechanism of action of this device is based on the reaction of sub-cellular photoreceptors to the light generated by the laser. Stimulation of these receptors causes an increase in metabolic processes by affecting the electron transport chain, respiratory chain, and oxidation [24]. LLLT causes dilation of blood vessels and the induction of mast cell degranulation, with the release of pro-inflammatory substances to accelerate tissue healing [23]. The effect of laser therapy on neurons results in stabilization of the membrane potential, which retards the activation of the pain signal [25, 26].
In this study, we examine how a diode laser at a wavelength of 635 nm and an ozone therapy affect the patients’ pain sensations during orthodontic treatment depending on teeth crowding.

Materials and methods

The trial was designed as a randomized and controlled test. Informed consent was obtained from all participating subjects. Approval was obtained from the Local Ethics Committee of the Faculty of Dentistry, Wrocław Medical University (KB-546/2018).

Subjects

The research concerned patients of NZOZ Ka-dent (a private healthcare institute) in Wschowa, undergoing orthodontic treatment. The study involved 90 patients (64 women and 26 men; age: 32.6 ± 8.7 years); however, the number of patients who met the inclusion criteria and agreed to participate in this study was 76 (55 women and 21 men; age: 35.1 ± 6.4 years) (Fig. 1).

The patients selected for the study

All the patients
1.
were treated for the first time using a fixed orthodontic appliance
 
2.
had no systemic diseases
 
3.
were not using anti-inflammatory drugs
 
4.
had not used antibiotics in the previous 24 months
 
5.
were non-smokers
 
6.
had fully erupted permanent teeth
 
7.
had no chronic or neural pain
 
8.
had undergone hygienist treatment before the clinical trial
 
Before the experiments, the experimental protocol and possible side effects were explained to the patients, and their informed consent was obtained.

Treatment procedure and pain evaluation

Immediately after orthodontic fixed appliance placement, the patients underwent a pain relief treatment using 635-nm diode laser (Smart M, Lasotronix, Poland) or an ozone generator (OzoneDTA; Apoza, Taiwan, ROC) with an intraoral probe by placing the handpieces in the area of each tooth apex and interdental papillae in the maxilla. The patients received a questionnaire for individual pain assessment (the numeric rating scale, NRS-11, grade level 0-10) measured at seven time points: 1 h, 6 h, 1 day, 2 days, 3 days, 4 days, and 5 days after the orthodontic appliance placement. The NRS-11 scale consists of conscious, subjective assessment of the pain experienced; therefore, it is used in the case of patients over 10 years old. A rating of 0 signifies no pain, 1–3 represents mild pain, 4–6 moderate pain, and 7–10 severe pain (Fig. 2).

Orthodontic treatment

Orthodontic fixed appliances (Legend Mini, GC Orthodontics, USA) that were used in the treatment of our patients had the following prescriptions: MBT, 0.018 slot. As initial arches, NiTI 0.014 was used (Atlas, Prolinx Gmbh, Germany).

Study groups

Group 1 (n = 26, control): no pain treatment after orthodontic appliance placement.
Group 2 (n = 25): ozone generator OzoneDTA (Apoza, New Taipei City, Taiwan) with the following fixed operation parameters; probe type 3, time per point 5 s; mode: contact, application on each tooth apex area and interdental papillae area, from the first left molar to the first right molar in the maxilla (23 points); total time of ozone application was 1 min and 55 s (one single session).
Group 3 (n = 25): diode laser SmartM (Lasotronix, Warsaw, Poland) at 635-nm wavelength with bio-modulating handpiece with the following set parameters: output power 400 mW, handpiece diameter 8 mm, spot area 0.5024 cm2, power density per second 1.59 W/cm2, continuous mode, dose 2 J per point, time 5 s per point, 23 points (irradiation on each tooth apex area and interdental papillae area from the maxillary right first molar to the maxillary left first molar), total energy per session 46 J, total time of the laser application was 1 min and 55 s (one single session). The diode laser was used in contact mode with soft tissue only immediately after the orthodontic appliance placement.
The subject allocation for these three groups was conducted using Random Allocation Software (University of Medical Science, Isfahan, Iran).

Teeth crowding assessment

Patients were qualified according to the level of teeth crowding based on the Lundstrom indicator. The upper dental arch was divided into six segments: S1–S6 (including the first molars). Each segment included a pair of teeth. The length of each segment (between the tangent points of the tooth pairs) and the mesiodistal width of 12 teeth were measured; the measurement result was entered into the table. The sum of the widths of each pair of teeth was determined as the amount of space needed in the dental arch. The differences showed excess or insufficient space in specific segments. By adding the value of S1–S6 differences, information about the size of the upper dental arch deviation from the actual tooth size was obtained. The patients in each group were divided into subjects with (Lundstrom indicator < 0) or without (Lundstrom indicator ≥ 0) teeth crowding (Fig. 3).

Statistical analysis

All data were subject to statistical analyses with Statistica 12 software (StatSoft, Krakow, Poland). The differences in the mean pain value between the groups were analyzed according to the ANOVA test followed by Tukey’s post hoc test. The differences in the pain related to teeth crowding were assessed using the Mann-Whitney U test. Values below p = 0.05 were considered to be significant.

Results

Evaluation of the highest pain value obtained in the study

The mean pain values on the NRS-11 for the diode laser, ozone, and control group were 3.6 ± 1.31 (95% CI, 2.95–4.25), 5.25 ± 3.37 (95% CI, 3.52–6.98) and 5.75 ± 2.40 (95% CI, 4.69–6.81) respectively. The statistical analysis of the NRS-11 scores revealed significantly lower pain values in the diode laser group in contrast to the control group (p = 0.0237). Furthermore, the use of ozone in the research resulted in a lack of pain reduction in contrast to the control subjects (Table 1).
Table 1
The mean pain value on the NRS-11 scale for the diode laser, ozone, and control group
Study groups
Number
NRS-11—means
Std. dev.
95% CI
p value
Control group (G1)
26
5.75
2.40
4.69–6.81
G1 vs G2 p = 0.8040
G1 vs G3 p = 0.0237
G2 vs G3 p = 0.1029
Ozone group (G2)
25
5.25
3.37
3.52–6.98
Laser group (G3)
25
3.60
1.31
2.95–4.25
All groups
76
4.87
2.63
4.17–5.57
95% CI (confidence interval)

Teeth crowding did not result in higher mean pain rate

In the present study, we assessed the pain rate for teeth pairs with or without crowding measured by a caliper. The results of this study rejected the hypothesis that teeth crowding caused higher pain rate measured with the NRS-11 scale as compared with non-crowding teeth pairs in all groups: G1 (p = 0.66), G2 (p = 0.86), G3 (p = 0.24) (Fig. 4).

The mean highest pain score was found 24 h after orthodontic appliance placement

Evaluation of pain levels in the control (G1), ozone (G2), and laser (G3) groups of patients at the different assessment times showed that the highest NRS-11 score was 24 h after orthodontic treatment in contrast to various pain assessment times (p < 0.05). The abovementioned findings suggested that laser irradiation should be used mainly in the first 24 h post orthodontic appliance placement (Fig. 5).

Discussion

Pain is a frequent feeling during orthodontic treatment. The purpose of the research was to investigate how photobiomodulation (PBM) and ozone therapy affect the sensation of pain during orthodontic treatment depending on teeth crowding. The main discovery of our study was that patients with crowded teeth and without crowding experience similar discomfort during orthodontic treatment. Furthermore, the laser application was more effective in relieving pain than ozone therapy. The results of this study confirmed that patients experience pain during orthodontic treatment with higher intensity during the first day. In all groups, the pain began 2 h after application of the orthodontic appliance, reaching a maximum after 24 h. Then, it gradually decreased, lasting up to 7 days after the application of orthodontic forces. The average NRS-11 value was 3.60, 5.25, and 5.75 for the diode laser, ozone therapy, and the control group, respectively. The results of our research were confirmed in different studies [3, 8], which found that discomfort reaches its maximum level 24 h after the application of the orthodontic appliance.
In the current research, we applied a diode laser with a wavelength of 635 nm. In the red to the near-infrared spectrum (600–1500 nm), light scattering predominates, and absorption has less effect; thus, the light enters up to a depth of 8–10 mm [27]. The penetration depth of a red laser is lower compared to the infra-red one. However, for the wavelength used in the study (635 nm), the minimum penetration depth is around 3 mm [27]. The aforementioned depth is sufficient to reach the inner part of the soft tissue as well as the tooth apex and the bone. Moreover, the energy dose should be in the range of Arndt-Schultz’s curve; thus, we decided to apply a dose of 2 J per point to reduce the pain after orthodontic appliance placement. LLLT has analgesic, anti-inflammatory, anti-swelling, and regenerative effects. The anti-inflammatory effect is achieved by increasing the secretion of serotonin which induces vasodilation. The concentration of heparin and histamine improves microcirculation and reduces the permeability of blood vessels, which protects against edema [27]. This anti-inflammatory effect is utilized in the management of pain in dental surgery [21, 27], periodontology, temporomandibular joint disorders [28, 29], and orthodontics [23].
One of the main objectives of the current study was to assess whether a diode laser with a wavelength of 635 nm can reduce pain occurring in the first days after orthodontic appliance placement. In our research, we obtained a good result for the laser wavelength at a dose per point of 2 J (400 mW, 4 J/cm2), as mentioned above. Similar positive results for a diode laser with a wavelength of 810 nm were shown in studies conducted by Farias at al. [30] (100 mW, 2 J/cm2) and Eslamian et al. [31] (100 mW, 2 J/cm2). In contrast to the studies mentioned above, there was the research of AlSayed et al. [23], who concluded that a 830-nm diode laser, applied at two doses of 4 and 16 J, was ineffective in relieving orthodontic pain induced by elastomeric separators. Furthermore, in the review published by Li et al. [32], the authors summarized that for the methodological deficiencies and risk of bias of randomized controlled trials, insufficient proof was submitted to conclude whether LLLT was effective in relieving orthodontic pain.
Moreover, positive results of a 940-nm diode laser at 100 mW, 7.5 J/cm2 on pain relief during orthodontic treatment were found by Qamruddin et al. [14]. The authors exhibited significantly lower mean NRS-11 score for spontaneous pain after insertion of the initial two archwires (0.012-in and 0.014-in NiTi; p < 0.05), while there was no significant difference for 0.016-in and 0.018-in wires between the LLLT and placebo groups [14]. In the present study, we also obtained promising results in pain relief for 0.014-in NiTi archwire after lasing with the 635-nm wavelength, in contrast to the control group. Furthermore, in their study, Bayani et al. [33] compared the effect of NSAIDs, bite wafers, LLLT with two wavelengths (660 nm and 810 nm) in orthodontic pain treatment. It was shown that a laser with a wavelength of 810 nm was the most effective. This finding is relevant because LLLT at various wavelengths could be an alternative to NSAIDs.
A particular focus in the present research was to assess the influence of ozone therapy in orthodontic pain treatment. Our results confirm the null hypothesis of no difference in the pain-reducing effect after the ozone application. The limited effect of ozone can be explained by a too superficial impact on the patient’s tissue, compared to the laser [15]. A further disadvantage of ozone is the decrease in effectiveness when encountering diffusion barriers such as plaque, saliva, and bacterial biofilm. This makes it difficult to penetrate the tissue and thus reduces the effect of ozone. However, ozone is mainly characterized by biocidal activity [15, 16]. During orthodontic treatment, aseptic inflammation of the surrounding tissues is present. Thus, a fundamental feature of ozone is improved oxygenation and nutrition of tissues. However, the use of ozone, which has antiseptic properties, did not lead to a significant reduction in the pain score in our study.
In this present study, we also evaluated the impact of crowding teeth on the sensation of pain during orthodontic treatment. In all the groups studied, there was no statistical difference between the groups explored. Therefore, we can reject the hypothesis that patients with crowded teeth experience greater discomfort than patients with no crowding of teeth. The results of this study confirmed the findings of other researchers who stated that the crowding of teeth or the force exerted on the teeth by the arch do not affect the pain experienced by patients at the beginning of treatment [34, 35]. However, there is no consistent thesis on discomfort during orthodontic treatment. Previous studies by Luppanapornlarp et al. [36] showed that stronger forces applied to the teeth were associated with more severe pain. They tried to compare the intensity of pain associated with exerting different strengths using nickel-titanium coil springs on segmented archwires. According to Hooke’s law, an increase in applied force results in a proportional increase in the deformation of a given material, in this case, an orthodontic wire. The wire can return to its original shape after the cessation of this force. This is known as elastic straining. This property of orthodontic wire is called elasticity. After the insertion of the orthodontic arch in patients with tightly crowded teeth, the orthodontic wire did not behave according to Hooke’s law, exerting the same force regardless of the degree of activation (deformation) [37]. It is expected that the force applied to the teeth will be the same regardless of the degree of tooth crowding. The results of our study can validate this hypothesis.
In our present research, the allocation of subjects to each group was performed randomly by a computer software—Random Allocation Software (University of Medical Science, Isfahan, Iran). However, the age and gender of the patients were not equal in sample size and could contribute to different pain thresholds and thus the overall estimate of the risk of bias for this study was reported to be at medium risk. Moreover, we can expect differences in the pain score in studies where elastic separators or first archwire was applied. Furthermore, there were some other limitations in our present study. We used the NRS scale to rate the feeling of pain, and thus the patients’ assessments were subjective [38, 39]. Therefore, further research should be carried out to search for more objective pain assessment methods during orthodontic treatment.

Conclusion

There are no differences in pain perception between patients with crowding teeth and non-crowding teeth. The pain was the highest 24 h after orthodontic appliance placement and gradually disappeared in the subsequent 7 days. Our study showed that the best effects in relieving pain were obtained with a laser wavelength of 635 nm. The use of ozone did not have significant effects.

Compliance with ethical standards

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

The approval of the Local Ethics Committee of the Faculty of Dentistry, Wrocław Medical University, was obtained (KB-546/2018).
Informed consent in accordance with the 1964 Helsinki Declaration was obtained from all participating subjects.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Dent – Das Online-Abo der Zahnmedizin

Online-Abonnement

Mit e.Dent erhalten Sie Zugang zu allen zahnmedizinischen Fortbildungen und unseren zahnmedizinischen und ausgesuchten medizinischen Zeitschriften.

Literatur
1.
Zurück zum Zitat Bergius M, Berggren U, Kiliaridis S (2002) Experience of pain during an orthodontic procedure. Eur J Oral Sci 110(2):92–98CrossRef Bergius M, Berggren U, Kiliaridis S (2002) Experience of pain during an orthodontic procedure. Eur J Oral Sci 110(2):92–98CrossRef
2.
Zurück zum Zitat Bergius M, Kiliaridis S, Berggren U (2000) Pain in orthodontics. A review and discussion of the literature. J Orofac Orthop 61(2):125–137CrossRef Bergius M, Kiliaridis S, Berggren U (2000) Pain in orthodontics. A review and discussion of the literature. J Orofac Orthop 61(2):125–137CrossRef
3.
Zurück zum Zitat Erdinc AM, Dincer B (2004) Perception of pain during orthodontic treatment with fixed appliances. Eur J Orthod 26(1):79–85CrossRef Erdinc AM, Dincer B (2004) Perception of pain during orthodontic treatment with fixed appliances. Eur J Orthod 26(1):79–85CrossRef
4.
Zurück zum Zitat Firestone AR, Scheurer PA, Bürgin WB (1999) Patients’ anticipation of pain and pain-related side effects, and their perception of pain as a result of orthodontic treatment with fixed appliances. Eur J Orthod 21(4):387–396CrossRef Firestone AR, Scheurer PA, Bürgin WB (1999) Patients’ anticipation of pain and pain-related side effects, and their perception of pain as a result of orthodontic treatment with fixed appliances. Eur J Orthod 21(4):387–396CrossRef
5.
Zurück zum Zitat Kavaliauskiene A, Smailiene D, Buskiene I, Keriene D (2012) Pain and discomfort perception among patients undergoing orthodontic treatment: results from one month follow-up study. Stomatologija 14(4):118–125PubMed Kavaliauskiene A, Smailiene D, Buskiene I, Keriene D (2012) Pain and discomfort perception among patients undergoing orthodontic treatment: results from one month follow-up study. Stomatologija 14(4):118–125PubMed
6.
Zurück zum Zitat Xiaoting L, Yin T, Yangxi C (2010) Interventions for pain during fixed orthodontic appliance therapy. A systematic review’. Angle Orthod 80(5):925–932CrossRef Xiaoting L, Yin T, Yangxi C (2010) Interventions for pain during fixed orthodontic appliance therapy. A systematic review’. Angle Orthod 80(5):925–932CrossRef
7.
Zurück zum Zitat Patel V (1989) Non-completion of orthodontic treatment. Br J Orthod 19:47–54CrossRef Patel V (1989) Non-completion of orthodontic treatment. Br J Orthod 19:47–54CrossRef
8.
Zurück zum Zitat Farzanegan F, Zebarjad SM, Alizadeh S, Ahrari F (2012) Pain reduction after initial archwire placement in orthodontic patients: a randomized clinical trial. Am J Orthod Dentofac Orthop 141:169–173CrossRef Farzanegan F, Zebarjad SM, Alizadeh S, Ahrari F (2012) Pain reduction after initial archwire placement in orthodontic patients: a randomized clinical trial. Am J Orthod Dentofac Orthop 141:169–173CrossRef
9.
Zurück zum Zitat Ngan P, Kess B, Wilson S (1989) Perception of discomfort by patients undergoing orthodontic treatment. Am J Orthod Dentofac Orthop 96:47–53CrossRef Ngan P, Kess B, Wilson S (1989) Perception of discomfort by patients undergoing orthodontic treatment. Am J Orthod Dentofac Orthop 96:47–53CrossRef
10.
Zurück zum Zitat Wilson S, Ngan P, Kess B (1989) Time course of the discomfort in young patients undergoing orthodontic treatment. Pediatr Dent 11:107–110PubMed Wilson S, Ngan P, Kess B (1989) Time course of the discomfort in young patients undergoing orthodontic treatment. Pediatr Dent 11:107–110PubMed
11.
Zurück zum Zitat Furstman L, Bernick S (1972) Clinical considerations of the periodontium. Am J Orthod 61:138–155CrossRef Furstman L, Bernick S (1972) Clinical considerations of the periodontium. Am J Orthod 61:138–155CrossRef
12.
Zurück zum Zitat Ecklund CR, Ross MC (2001) Over-the-counter medication use in preschool children. J Pediatr Health Care 15:168–172CrossRef Ecklund CR, Ross MC (2001) Over-the-counter medication use in preschool children. J Pediatr Health Care 15:168–172CrossRef
13.
Zurück zum Zitat Kim WT, Bayome M, Park JB, Park JH, Baek SH, Kook YA (2013) Effect of frequent laser irradiation on orthodontic pain. A single-blind randomized clinical trial. Angle Orthod 83:611–616CrossRef Kim WT, Bayome M, Park JB, Park JH, Baek SH, Kook YA (2013) Effect of frequent laser irradiation on orthodontic pain. A single-blind randomized clinical trial. Angle Orthod 83:611–616CrossRef
14.
Zurück zum Zitat Qamruddin I, Alam MK, Abdullah H, Kamran MA, Jawaid N, Mahroof V (2018) Effects of single-dose, low-level laser therapy on pain associated with the initial stage of fixed orthodontic treatment: a randomized clinical trial. Korean J Orthod 48(2):90–97CrossRef Qamruddin I, Alam MK, Abdullah H, Kamran MA, Jawaid N, Mahroof V (2018) Effects of single-dose, low-level laser therapy on pain associated with the initial stage of fixed orthodontic treatment: a randomized clinical trial. Korean J Orthod 48(2):90–97CrossRef
15.
Zurück zum Zitat Néri JDV, Lomba E, Karam AM (2017) de Almeida ReisSR, Marchionni AMT, Medrado ARAP. Ozone therapy influence in the tissue repair process: a literature review. J Oral Diag 2(1):1–6 Néri JDV, Lomba E, Karam AM (2017) de Almeida ReisSR, Marchionni AMT, Medrado ARAP. Ozone therapy influence in the tissue repair process: a literature review. J Oral Diag 2(1):1–6
16.
Zurück zum Zitat Chaves RM, Estrela C, Cardoso PC, Estrela CR (2017) MagalhãesAP, Lopes LG. Ozone gas effect on mineral content of dentin exposed to Streptococcus mutans biofilm: an energY-dispersive X-ray evaluation. J Contemp Dent Pract 18(4):265–269CrossRef Chaves RM, Estrela C, Cardoso PC, Estrela CR (2017) MagalhãesAP, Lopes LG. Ozone gas effect on mineral content of dentin exposed to Streptococcus mutans biofilm: an energY-dispersive X-ray evaluation. J Contemp Dent Pract 18(4):265–269CrossRef
17.
Zurück zum Zitat Akdeniz SS, Beyler E, Korkmaz Y, Yurtcu E, Ates U, Araz K, Torun OY (2018) The effects of ozone application on genotoxic damage and wound healing in bisphosphonate-applied human gingival fibroblast cells. Clin oral investing 22(2):867–873CrossRef Akdeniz SS, Beyler E, Korkmaz Y, Yurtcu E, Ates U, Araz K, Torun OY (2018) The effects of ozone application on genotoxic damage and wound healing in bisphosphonate-applied human gingival fibroblast cells. Clin oral investing 22(2):867–873CrossRef
18.
Zurück zum Zitat Borzabadi-Farahani A (2017) The adjunctive soft-tissue diode laser in orthodontics. Compend Contin Educ Dent 38(eBook 5):e18PubMed Borzabadi-Farahani A (2017) The adjunctive soft-tissue diode laser in orthodontics. Compend Contin Educ Dent 38(eBook 5):e18PubMed
19.
Zurück zum Zitat Matys J, Swider K, Flieger R (2017) Laser instant implant impression method: a case presentation. Dent Med Probl 54(1):101–106CrossRef Matys J, Swider K, Flieger R (2017) Laser instant implant impression method: a case presentation. Dent Med Probl 54(1):101–106CrossRef
20.
Zurück zum Zitat Cho KW, Cho SW, Oh O, Ryu YK, Ohshima H, Jung HS (2007) The effect of cortical activation on orthodontic tooth movement. Oral Dis 13(3):314–319CrossRef Cho KW, Cho SW, Oh O, Ryu YK, Ohshima H, Jung HS (2007) The effect of cortical activation on orthodontic tooth movement. Oral Dis 13(3):314–319CrossRef
21.
22.
Zurück zum Zitat Grzech-Leśniak K, Matys J, Żmuda-Stawowiak D, Mroczka K, Dominiak M, Brugnera Junior A, Gruber R, Romanos GE, Sculean A (2018) Er:YAG laser for metal and ceramic bracket debonding: an in vitro study on intrapulpal temperature, SEM, and EDS analysis. Photomed Laser Surg 36(11):595–600. https://doi.org/10.1089/pho.2017.4412 CrossRefPubMed Grzech-Leśniak K, Matys J, Żmuda-Stawowiak D, Mroczka K, Dominiak M, Brugnera Junior A, Gruber R, Romanos GE, Sculean A (2018) Er:YAG laser for metal and ceramic bracket debonding: an in vitro study on intrapulpal temperature, SEM, and EDS analysis. Photomed Laser Surg 36(11):595–600. https://​doi.​org/​10.​1089/​pho.​2017.​4412 CrossRefPubMed
23.
Zurück zum Zitat AlSayed Hasan MM, Sultan K, Hamadah O (2018) Evaluating low-level laser therapy effect on reducing orthodontic pain using two laser energy values: a split-mouth randomized placebo-controlled trial. Eur J Orthod 40(1):23–28CrossRef AlSayed Hasan MM, Sultan K, Hamadah O (2018) Evaluating low-level laser therapy effect on reducing orthodontic pain using two laser energy values: a split-mouth randomized placebo-controlled trial. Eur J Orthod 40(1):23–28CrossRef
27.
Zurück zum Zitat Matys J, Świder K, Grzech-Leśniak K, Dominiak M, Romeo U (2019) Photobiomodulation by a 635nm diode laser on peri-implant bone: primary and secondary stability and bone density analysis - a randomized clinical trial. Biomed Res Int 2019(2785302):8. https://doi.org/10.1155/2019/2785302 CrossRef Matys J, Świder K, Grzech-Leśniak K, Dominiak M, Romeo U (2019) Photobiomodulation by a 635nm diode laser on peri-implant bone: primary and secondary stability and bone density analysis - a randomized clinical trial. Biomed Res Int 2019(2785302):8. https://​doi.​org/​10.​1155/​2019/​2785302 CrossRef
28.
Zurück zum Zitat Ahrari F, Madani AS, Ghafouri ZS, Tunér J (2014) The efficacy of low-level laser therapy for the treatment of myogenous temporomandibular joint disorder. Lasers Med Sci 29(2):551–557CrossRef Ahrari F, Madani AS, Ghafouri ZS, Tunér J (2014) The efficacy of low-level laser therapy for the treatment of myogenous temporomandibular joint disorder. Lasers Med Sci 29(2):551–557CrossRef
29.
Zurück zum Zitat Salmos-Brito JA, de Menezes RF, Teixeira CE, Gonzaga RK, Rodrigues BH, Braz R, Bessa-Nogueira RV, de Martínez Gerbi ME (2013) Evaluation of low-level laser therapy in patients with acute and chronic temporomandibular disorders. Lasers Med Sci 28(1):57–64CrossRef Salmos-Brito JA, de Menezes RF, Teixeira CE, Gonzaga RK, Rodrigues BH, Braz R, Bessa-Nogueira RV, de Martínez Gerbi ME (2013) Evaluation of low-level laser therapy in patients with acute and chronic temporomandibular disorders. Lasers Med Sci 28(1):57–64CrossRef
30.
Zurück zum Zitat Farias RD, Closs LQ, Miguens SA Jr (2016) Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: a randomized split-mouth clinical trial. Angle Orthod 86(2):193–198CrossRef Farias RD, Closs LQ, Miguens SA Jr (2016) Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: a randomized split-mouth clinical trial. Angle Orthod 86(2):193–198CrossRef
31.
Zurück zum Zitat Eslamian L, Borzabadi-Farahani A, Hassanzadeh-Azhiri A, Badiee MR, Fekrazad R (2014) The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators. Lasers Med Sci 29(2):559–564CrossRef Eslamian L, Borzabadi-Farahani A, Hassanzadeh-Azhiri A, Badiee MR, Fekrazad R (2014) The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators. Lasers Med Sci 29(2):559–564CrossRef
32.
Zurück zum Zitat Li FJ, Zhang JY, Zeng XT, Guo Y (2015) Low-level laser therapy for orthodontic pain: a systematic review. Lasers Med Sci 30(6):1789–1803CrossRef Li FJ, Zhang JY, Zeng XT, Guo Y (2015) Low-level laser therapy for orthodontic pain: a systematic review. Lasers Med Sci 30(6):1789–1803CrossRef
34.
Zurück zum Zitat Jones M, Chan C (1992) The pain and discomfort experienced during orthodontic treatment: a randomized controlled clinical trial of two initial aligning arch wires. Am J Orthod Dentofac Orthop 102(4):373–381CrossRef Jones M, Chan C (1992) The pain and discomfort experienced during orthodontic treatment: a randomized controlled clinical trial of two initial aligning arch wires. Am J Orthod Dentofac Orthop 102(4):373–381CrossRef
36.
Zurück zum Zitat Luppanapornlarp S, Kajii TS, Surarit R, Iida J (2010) Interleukin-1beta levels, pain intensity, and tooth movement using two different magnitudes of continuous orthodontic force. Eur J Orthod 32:596–601CrossRef Luppanapornlarp S, Kajii TS, Surarit R, Iida J (2010) Interleukin-1beta levels, pain intensity, and tooth movement using two different magnitudes of continuous orthodontic force. Eur J Orthod 32:596–601CrossRef
37.
Zurück zum Zitat Water NE (1992) Orthodontic products update: superelastic nickel- titanium wires. Br J Orthod 1-9:319–322CrossRef Water NE (1992) Orthodontic products update: superelastic nickel- titanium wires. Br J Orthod 1-9:319–322CrossRef
38.
Zurück zum Zitat Eslamian L, Borzabadi-Farahani A, Gholami H (2016) The effect of benzocaine and ketoprofen gels on pain during fixed orthodontic appliance treatment: a randomised, double-blind, crossover trial. Aust Orthod J 32(1):64–72PubMed Eslamian L, Borzabadi-Farahani A, Gholami H (2016) The effect of benzocaine and ketoprofen gels on pain during fixed orthodontic appliance treatment: a randomised, double-blind, crossover trial. Aust Orthod J 32(1):64–72PubMed
39.
Zurück zum Zitat Eslamian L, Borzabadi-Farahani A, Edini HZ, Badiee MR, Lynch E, Mortazavi A (2013) The analgesic effect of benzocaine mucoadhesive patches on orthodontic pain caused by elastomeric separators, a preliminary study. Acta Odontol Scand 71(5):1168–1173CrossRef Eslamian L, Borzabadi-Farahani A, Edini HZ, Badiee MR, Lynch E, Mortazavi A (2013) The analgesic effect of benzocaine mucoadhesive patches on orthodontic pain caused by elastomeric separators, a preliminary study. Acta Odontol Scand 71(5):1168–1173CrossRef
Metadaten
Titel
Effect of ozone and diode laser (635 nm) in reducing orthodontic pain in the maxillary arch—a randomized clinical controlled trial
verfasst von
Jacek Matys
Elżbieta Jaszczak
Rafał Flieger
Katarzyna Kostrzewska-Kaminiarz
Kinga Grzech-Leśniak
Marzena Dominiak
Publikationsdatum
05.11.2019
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 2/2020
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-019-02896-0

Weitere Artikel der Ausgabe 2/2020

Lasers in Medical Science 2/2020 Zur Ausgabe