Skip to main content
Erschienen in: BMC Complementary Medicine and Therapies 1/2018

Open Access 01.12.2018 | Research article

Effects of transcutaneous electrical nerve stimulation in the Management of Post-Injection Sciatic Pain in a non-randomized controlled clinical trial in Nnewi, Nigeria

verfasst von: Uchenna Prosper Okonkwo, Sam Chidi Ibeneme, Ebere Yvonne Ihegihu, Afamefuna Victor Egwuonwu, Ikechukwu Charles Ezema, Adesina Fatai Maruf, Emmanuel Chiebuka Okoye, Olanrewaju Peter Ibikunle, Antoninus Obinna Ezeukwu

Erschienen in: BMC Complementary Medicine and Therapies | Ausgabe 1/2018

Abstract

Background

Many studies on transcutaneous electrical nerve stimulation (TENS) had been undertaken to explore its pain relieving efficiency on several medicals/surgical conditions but none, specifically, had been carried out to determine the effect it has on post-injection sciatic pain (PISP) which comes about from wrong administration of intramuscular pain. This study aims to assess the effects of TENS in the management of PISP.

Methods

A total of 72 PISP subjects comprising 40 test subjects and 32 control subjects participated in a non-randomized controlled clinical trial in the current study. Participants were recruited from Department of Physiotherapy, Nnamdi Azikiwe University Teaching Hospital, Nnewi and Landmark Physiotherapy Services, Nnewi. The participants were however blinded to the intervention method they will receive before being allotted conveniently to test/experimental group (TG) or control group (CG). A written informed consent was obtained from participants before enrollments in the study. TENS and sham TENS (STENS) was applied to 40 test and 32 subjects respectively, 3 times a week, and 1 hour per session for the 10 weeks the study lasted. The Visual Analogue Scale was used to collect baseline data as well as those of 2nd, 4th, 6th, 8th and 10th weeks after TENS and STENS interventions. The data analysis was performed with the Descriptive statistic of Mean ± SD, mean comparison test, repeated analysis of variance and paired wise t-test. Statistical level of significance was set at P < 0.05.

Result

Results of repeated measure ANOVA showed that the pain level among participants in the treatment group at the end (after 10 weeks) of the intervention was significantly lower than that of their counterparts in the control group (F = 16.26; p = 0.01); with the intervention accounting for the 19% of the variance. The effect size (partial eta squared) = 0.19.

Conclusion

The outcome of this research has proved the effectiveness of TENS in the management of PISP and is being recommended in the management of PISP.

Trial registration

Pan Africa Clinical Trial Registry (PACTR20180500340​8271). The study was registered retrospectively on the 29th May, 2018.
Hinweise
The original version of this article was revised: the name of one of the authors had been listed incorrectly as ‘Antoninus Obinna Ezekwu'. It should be ‘Antoninus Obinna Ezeukwu'.
A correction to this article is available online at https://​doi.​org/​10.​1186/​s12906-018-2398-z.
Abkürzungen
CG
control group
NAUTHEC
Nnamdi Azikiwe University Teaching Hospital Ethics Committee
NII
Nerve Injection Injury
PISP
post injection sciatic pain
SD
Standard division
SNII
Sciatic Nerve Injection Injury
STENS
sham transcutaneous electrical nerve stimulation
TENS
transcutaneous electrical nerve stimulation
TG
treatment group
VAS
Visual Analog scale
X
Mean

Background

Nerve injection injury (NII) is a common complication following intramuscular injection; the sciatic nerve is the most frequently affected nerve [1, 2]. Sciatic nerves injection injury (SNII) has been recognized for many years: ‘sciatic neuritis due to injection’ was first reported in 1882 [3], sciatic nerve injuries were reported after quinine injections as early as 1920 [4]. However, SNII remains a persistent global problem that affects patients in both wealthy and poorer healthcare systems [5]. The World Health Organization has estimated that of the 12 billion injections administered globally every year, 50% of them are unsafely administered and 75% are unnecessarily administered [6]. Post-injection sciatic pain is a particular type of pain that stems from an injury to the sciatic nerve and its clinical presentations mimic that of sciatica only that its pain routes from the injection site downward. Due to its sensitive anatomical location and its supply of most of the muscles of the lower limbs the sciatic nerve is often times directly or indirectly traumatized during the process of administering an intramuscular injection or direct pressure on scar formation. The sciatic nerve can also be irritated by some other medical problems such as a herniating disc. The consequence of these on the body system is the generation of painful sensation that traverses partially or completely the route of the sciatic nerve and is known as sciatica. PISP has an intriguing nature and could present with the symptoms of pain, weakness, numbness and other discomforts along the sciatic nerve. It can afflict adults and non-adult from time to time and subsequently continues to interfere with the activities of daily living (ADL). There are varied causes/manifestations of pain; as such different medical options aimed at alleviating it may include surgical and non-surgical methods. The results of surgical approach or intervention in most cases are very disappointing. The non-surgical management involves administration of medicines, acupuncture, chiropractic, and physical therapy. One of the physical therapy modalities used in this regard is transcutaneous electrical nerve stimulation (TENS).
Significantly, when giving gluteal injections, it is safe to use the upper outer quadrant. The choice of site for injection must be based on good clinical judgment, using the best evidence available and individualized client assessment. There is wide agreement on the literature that the ventrogluteal site is preferable [7]. Review of the literature on relevant injection procedure found that injury to the sciatic nerve was associated with the use of the dorsogluteal site for injection. Sciatic pain affects one side of the lower limb; presenting with dull, sharp, or accompanied by intermittent shocks of shooting pain beginning at the buttock, travelling downward into the back or side of the thigh and / or leg. Sciatic pain then extends over the knees and may be felt in the feet. Sometimes symptoms may also include tingling sensation, sitting and trying to stand up is painful and difficult. Coughing and sneezing can intensify the pain [8]. Some medical disorders that can cause sciatica include: herniating discs, degenerative diseases of the lumbosacral spine, lumbar spinal stenosis, spondylolisthesis, spinal tumors, infections and Intramuscular injection [9]. The management of PISP can pose great difficulty to physicians and other medical professionals, as it sometimes does not arise immediately after an intramuscular injection. Authors experience in many years of clinical practice shows many clients have even forgotten about the injection experience. The modalities available for pain relief in physiotherapy practice include but not limited to infra-red radiation, manipulative therapy, interferential therapy, and Transcutaneous Electrical Nerve Stimulations (TENS), amongst others. Most times these options are used in combination in order to achieve maximal benefit [10].
For years, clinicians have been using TENS in an attempt to manage pain. It has been widely used in the treatment of various types of pain. It has also been shown that TENS is highly effective alleviating pain and reducing analgesic use following cesarean section, orthopedic and thoracic operations as well as mixed surgical procedures [11]. TENS is defined by the American Physical Therapy Association as the application of the electrical stimulation to the skin for pain relief [12]. Usually, the frequency, intensity, and pulse duration of the stimulation can be varied [10]. Conventional TENS is the most common mode used clinically and applies high frequency (> 50 Hz) and low intensity (below motor contraction, sensory only) stimulation parameters. Another common mode of stimulation uses low frequency (< 50 Hz) and high intensity (motor contraction) stimulation parameters [13]. Furthermore, increasing stimulation intensity to produce a painful noxious response is usually given at low frequency, and is called acupuncture-like TENS and is the least common [13].
Pain is a subjective sensation and therefore difficult to quantify. It is, however, important to quantify it for several reasons; one of the most compelling reasons is that assigning a measurement of pain gives patients a sense of control over their condition and has positive effects on their cop abilities. Pain measurements also provide a means of assessing the efficacy of response to treatment and prognosis. The Visual Analogue Scale (VAS) is a well-studied method of measuring both acute and chronic pain; its usefulness has been validated by several investigators [1416].
Individuals who have PISP are often driven to seek relief from conventional medical treatment, alternative therapies, to miracle centers. One of the long-term effects being that many of the patients with PISP that were later referred for physiotherapy are in chronic stages of the problem. This study, therefore, examines the possibility of the use of TENS to bridge this gap. There were no previous empirical studies on the effect of TENS in managing PISP. The nearest were several case reports and a small number of controlled trials which reported improvements in pain symptoms in people with peripheral neuropathy or nerve damage [17, 18]. However, these studies suffer deficits of poor design or reporting hence additional researches are needed before a firm conclusion can be drawn about effectiveness. Consequently, there was not enough reliable evidence to draw a firm conclusion of this area [19, 20]. This lack of precedence over this research had created the problem of readymade standard protocol for a research of this nature. However; the empirical studies on the effect of TENS in managing other medical /surgical pains would be strongly relied upon. The working hypothesis is that there will be no significant difference between the test group and the control after 10 weeks of TENS and STENS application.

Methods

The current study was a non-randomized controlled clinical trial involving seventy-two subjects − 40 test and 32 control participants. Participants were recruited from patients referred to Department of Physiotherapy, Nnamdi Azikiwe University Teaching Hospital, Nnewi and Landmark Physiotherapy Services, Nnewi. The purposive sampling technique was applied; all the subjects were required to meet certain selection criteria before participation in the study. Participants were blinded to the intervention they would receive by the investigator; two plain sheet papers had inscriptions T or C and folded. As participants came they were asked to pick either of the papers. Those that pick T will go to the TG while those that pick C will go to the CG. Ethical approval was sought from Nnamdi Azikiwe University Teaching Hospital Ethics Committee (NAUTHEC), Nnewi. A written informed consent was obtained from the participants in the study. The Visual Analogue Scale (VAS) was presented and described to participating subjects who were instructed to describe their level of pain by signifying a number on the VAS scale; 10 cm is the highest level of pain and 0 cm shows no pain. The baseline VAS scores were recorded for all the participants; it will constitute the basis of comparison of subsequent VAS scores. By this procedure, the mean pre and post VAS scores were obtained for the TG and CG at 2nd, 4th, 6th, 8th, and 10th weeks. The data analysis was performed with student t-test and independent t-test. Statistical level of significance was set at P < 0.05. The current study adheres to CONSORT guidelines.

Sample size

The sample size determination was based on the 17% prevalence of injection palsy yearly as reported by Fatunde and Famulusi in Nigeria [21] and [22].
$$ {\displaystyle \begin{array}{c}\mathrm{Sample}\kern0.17em \mathrm{size}\left(\mathrm{n}\right)=\frac{Z^2\mathrm{p}\left(1-\mathrm{p}\right)}{{\mathrm{d}}^2}\\ {}\mathrm{p}=\mathrm{prevalence}=17\%=0.17\\ {}\mathrm{Z}=\mathrm{Z}\ \mathrm{statistic}\ \mathrm{for}\ 95\%\mathrm{level}\ \mathrm{of}\ \mathrm{confidence}=1.96\\ {}\mathrm{d}=\mathrm{precision}=0.05\end{array}} $$
it is recommended by various authors that a precision of 5% is appropriate for prevalence rates between 10 and 90% [2224].
$$ \mathrm{n}=\frac{1.96^2\times 0.17\left(1-0.17\right)}{(0.05)^2} $$
$$ \mathrm{n}=\frac{3.8416\times 0.1411}{0.0025} $$
$$ \mathrm{n}=\frac{0.54197921}{0.0025} $$
$$ {\displaystyle \begin{array}{l}\mathrm{n}=217\\ {}\mathrm{Calculated}\ \mathrm{sample}\ \mathrm{size}=217\end{array}} $$

Inclusion criteria

  • the age range of 20 to 50 years
  • post injection sciatic pain of not more than 1 year
  • participants that stopped the medication for 2 weeks before intervention
  • participants without foot drop
  • participants without significant wasting of the muscles

Exclusion criteria

  • Spondylosis
  • osteoarthritis of the knee
  • metallic implant
  • mentally unbalanced participants
  • participants that refused to stop the medication
  • very elderly people

Intervention procedures

Test group

Only TENS application was used on the 42 subjects that participated in the test group. Each patient was then made to lie on the available treatment plinth in a position (prone lying) that was comfortable and suitable for TENS application.

The Electrodes Placement

The adhesive electrodes were four in number in the dual channel type of TENS. They were securely placed along the route or course of the presenting sciatic pain (Figs. 1, 2 and 3) as maximum pain relief is obtained when the electrodes are placed on the painful area [25]. These electrode placement methods were applied throughout the period of study for the two groups. Patients’ education on the workings of TENS and skin toileting preceded the electrode application.

TENS Mode

TENS which uses lower frequency stimulation (2-5 Hz) and a wider (longer) pulse width of (200-250us) with an intensity greater than that of the traditional TENS was chosen because of its “carryover effect”. With all settings on zero, the TENS machine was switched on and the output increased until the patient perceives a fairly strong buzzing or pulsating sensation. The parameters of pulse frequency, pulse width, and pulse amplitude were varied from minimum to maximum rates of the chosen TENS mode to demonstrate the range to the subjects. The rate was varied (because each patient/subject felt and experienced each of these parameters differently) until the level that was most comfortable to the subject and which did not produce motor contraction was found. When the subject ceased to feel the stimulus after a few minutes probably because of nervous accommodation the output intensity was turned up until some strong sensation was felt again.

Duration of TENS Application

Each subject received a total of 1 h of TENS per treatment session comprising 20 min per each 3 electrode placement methods. This added up to 3 h of TENS treatments per week which amounted to 30 h for the 10 weeks the study lasted.

Control group (sham TENS)

The 32 subjects that fell into this group were available as a control group. The sham TENS application followed the same procedure of application except that the sham TENS was not switched on throughout the period the treatment lasted. To ensure that the participants were not biased they were not told the TENS modality on them were just a mere sham. The VAS scores before and after the application of the sham TENS were taking from the patients and appropriately recorded. The subjects positioning and other procedural formalities were the same as described for the test group above.

Materials/equipment of study

  • A dual channel TENS (EZ 105 Model) with a variable pulse frequency of 2-250 Hz, the variable pulse width of 50–250 microseconds and variable pulse intensity (amplitude) of 0-80 mA produced by Avionix Medical Devices, Texas, USA (Appendix 4) was used for both the test group and the control group. But that of the control was not activated to deliver electrical impulses to the control subjects.
  • Stethoscope - Littman’s model
  • Mercury Sphygmomanometer (Accusson model)
  • Cotton and pin for skin sensation test.
  • Measuring tape for muscle bulk measurement.
  • Toilet soap, distilled water, and hand towel for skin cleansing.
  • Visual analog scale by Price et al. [26]. Used for pain assessment pre and post-treatment.
  • A Seca model weighing scale calibrated in a kilogram.
  • A Seca model stadiometer calibrated in centimeter and inches.

Statistical analysis

The SPSS software package version 23 was applied for data analysis. Descriptive statistic of Mean ± SD and mean comparison test was used to analyze baseline characteristics of subjects. Repeated analysis of variance was (ANOVA) was used to compare mean VAS scores between the TG and CG. A paired t-test was used for pair-wise comparison of pain level in each group across 10 weeks the Statistical level of significance was set at P < 0.05.

Results

In Table 1 baseline characteristics shows 72 patients that participated in the study 40 were males while 32 were females. In the test group 40 patients participated, 24 were males while 16 were females. Their mean age was 29.737 ± 15.225 years and the mean duration of symptom was 3.95 ± 1.724. The mean body weight, height, and VAS were 55.700 ± 17.635 kg, 1.410 ± .1464 m and 6.23 ± 2.731 respectively. For the control group, of the 32 participants, 16 were males while 16 were females. The mean age for the control group was 38.409 ± 18.157 years and mean duration of symptom was 5.125 ± 1.738. The mean body weight, height, and VAS were 59.156 ± 8.648 kg, 1.41 ± .124 m and VAS 6.63 ± 2.297 respectively.
Table 1
Baseline characteristics of the groups evaluated at initial assessment
Variable
Experimental (N = 40)
Control (N = 32)
Male = 24
Male = 16
Female = 16
Female = 16
Mean ± SD
Mean ± SD
Age (years)
29.737 ± 15.225
38.409 ± 18.157
Duration of symptom (months)
3.95 ± 1.724
5.125 ± 1.738
Weight (Kilogram)
55.700 ± 17.635
59.156 ± 8.648
Height (meters)
1.410 ± .1464
1.41 ± .124
VAS baseline
6.23 ± 2.731
6.63 ± 2.297
In Table 2 there was no significant difference between the test and control group for weight, height, and VAS at baseline. In contrast, there was a significant difference between test and control groups for age and duration of the symptom.
Table 2
Baseline mean comparison of age, duration of symptom, weight, height and visual analogue scale
Variable
Experimental
Control
t – value
P – value
Mean ± SD
Mean ± SD
Age (years)
29.737 ± 15.225
38.409 ± 18.157
−2.222
0.029*
Duration of symptom (months)
3.95 ± 1.724
5.125 ± 1.738
- 2.864
.006*
Weight (Kilogram)
55.700 ± 17.635
59.156 ± 8.648
- 1.014
.314
Height (meters)
1.410 ± .1464
1.41 ± .124
.-077
.939
VAS baseline
6.23 ± 2.731
6.63 ± 2.297
−.662
. 510
*significant at p < 0.05
Table 3 shows the mean pain levels (visual analog scale scores) of the participants in both experimental and control groups across 10 weeks. Unlike in the control group, there was a continuous decrease in pain levels in the experimental group across the duration of the study. Results of repeated measure ANOVA showed that the pain level among participants in the treatment group at the end (after 10 weeks) of the intervention was significantly lower than that of their counterparts in the control group (F = 16.26; p = 0.01); with the intervention accounting for the 19% of the variance (Table 4).
Table 3
Mean visual analogue scale scores of the participants in each group across 10 weeks
Time
Mean ± Standard deviation
Treatment
Control
Baseline Scores
6.23 ± 2.73
6.63 ± 2.30
After 2 Weeks
4.50 ± 3.07
6.09 ± 2.28
After 4 Weeks
3.63 ± 3.44
6.25 ± 2.17
After 6 Weeks
2.93 ± 3.15
6.28 ± 2.45
After 8 Weeks
2.73 ± 3.28
5.94 ± 2.03
After 10 Weeks
2.50 ± 3.23
5.50 ± 2.30
Table 4
Repeated measure ANOVA comparing the mean visual analogue scale scores between experimental and control groups after the intervention
Degree of freedom
Mean square
F
P
Partial Eta Squared
1
596.40
16.26
< 0.01*
0.19
*significant at p < 0.05
The paired comparison revealed that each of the pain level scores at the end of second, fourth, sixth, eightieth and tenth weeks was significantly lower than the baseline pain level score among the participants in the experimental group. In the experimental group, there was a significant difference in the pain levels in each pair of baseline, second, fourth, sixth, eightieth and tenth week (p < 0.05) except between pain levels at sixth and eightieth, and between those at eightieth and tenth weeks. In the control group, the baseline pain level was significantly lower than that at second, eightieth and tenth weeks (p < 0.05) (Table 5).
Table 5
Paired t test showing pair-wise comparison of pain level in each group across 10 weeks
(I) Time
Time (J)
T
P
Experimental Group
Baseline
After 2 weeks
4.72
< 0.01*
 
After 4 weeks
5.89
< 0.01*
 
After 6 weeks
6.48
< 0.01*
 
After 8 weeks
6.58
< 0.01*
 
After 10 weeks
7.16
< 0.01*
After 2 weeks
After 4 weeks
2.49
0.02*
 
After 6 weeks
4.26
< 0.01*
 
After 8 weeks
4.43
< 0.01*
 
After 10 weeks
5.19
< 0.01*
After 4 weeks
After 6 weeks
2.46
0.02*
 
After 8 weeks
2.93
0.01*
 
After 10 weeks
3.78
0.01*
After 6 weeks
After 8 weeks
1.48
0.15
 
After 10 weeks
2.38
0.02*
After 8 weeks
After 10 weeks
1.22
0.23
Control Group
Baseline
After 2 weeks
2.52
0.02
 
After 4 weeks
1.34
0.19
 
After 6 weeks
1.09
0.29
 
After 8 weeks
2.87
0.01
 
After 10 weeks
4.03
< 0.01
After 2 weeks
After 4 weeks
−0.50
0.62
 
After 6 weeks
−0.63
0.54
 
After 8 weeks
0.63
0.53
 
After 10 weeks
1.93
0.06
After 4 weeks
After 6 weeks
−0.12
0.90
 
After 8 weeks
1.26
0.22
 
After 10 weeks
3.28
< 0.01
After 6 weeks
After 8 weeks
1.46
0.16
 
After 10 weeks
2.91
0.01
After 8 weeks
After 10 weeks
1.60
0.12
*significant at p < 0.05

Discussions

This study evaluated the effect of Transcutaneous Electrical Nerve Stimulation (TENS) in the management of sciatic pain following intramuscular injection. In carrying out the current study the authors noted that no similar studies had been done in the past regarding the effect of TENS in the management of PISP; however, the effect of TENS in managements other medical and surgical conditions were well documented. Interestingly, these studies used TENS device as adjunctive therapy, but most of the outcomes had not equivocally established combination therapy as producing lasting pain relief on the patients, This notwithstanding, the use of TENS in combination with other therapies were suggested by most previous studies in contrast to using it in monotherapy form as applied in this current study [18, 27]. The authors have noted that previous studies provided promising preliminary evidence about TENS but did not include clear descriptions of research design or results. This lack of detailed design has led to most of the published studies on TENS producing conflicting outcomes about the actual efficacy of TENS application. The authors had identified several factors which could contribute to these conflicting reports such as unspecified stimulation parameters, stimulation variables not controlled during the research process, different outcome measures, different electrodes placements, lack of placebo control, patients presenting at different stages in disease process, and failure to monitor or document patient’s compliance [18, 2831]. The outcome of this current study has brought to limelight the importance of one of the physical therapy modalities in managing PISP.
The result in Table 3 shows a trend in mean value variations between the two groups, unlike in the control group, there was a continuous decrease in pain levels in the experimental group across the duration of the study. Figure 4 shows the pictorial comparison of the mean pain levels between the two groups at baseline, second, fourth, sixth, eightieth and tenth weeks. This is an indication that TENS, a non-invasive modality, commonly used in physiotherapy is able to reduce PISP in the treatment group, unlike the placebo group. This study agreed with previous studies on the efficacy of TENS in pain management [3234]. Specifically, the study by White et al. showed that TENS effectively decreased pains in 64 adults with disc herniation related sciatic pain by 23%, while the oral drugs intake was reduced by 15% [35]. This current study was done on the assumption that since TENS had been widely reported to be useful in managing various kinds of pain from dental procedures; osteoarthritis of the knee; angina pectoris; low back pain and chronic pain of all sorts; peripheral neuropathy to rheumatoid arthritis, that it could also be beneficial in managing PISP [17, 18, 3642].
Results of repeated measure ANOVA showed that the pain level among participants in the treatment group at the end (after 10 weeks) of the intervention was significantly lower than that of their counterparts in the control group (F = 16.26; p = 0.01); with the intervention accounting for the 19% of the variance. The effect size (partial eta squared) was 0.19 (large) (Table 4). The clinical implication is that those in the test group responded better to TENS application than those who received STENS. Though there was some improvement in the control group as shown in Table 5 (pair-wise comparison of pain level), the authors were of the opinion that the said improvement, which might have resulted from the placebo effect and the possibility of subjects taking pain-relieving drugs, did not equal the improvement in the test group. The finding from the current study has rejected the working null hypothesis that there will be no significant difference (p > 0.05) between the TG and the CG after 10 weeks of TENS and STENS applications.
It has to be emphasized that TENS achieves its pain relief: pain gate mechanism or the endogenous opioid system. The variations in stimulation parameter used to activate these two systems will be briefly considered. Pain relief by means of the pain gate mechanism involves activation (excitation) of the beta sensory fibers, and by so doing reduce the transmission of the noxious stimulus from the ‘c’ fibers, through the spinal cord and on to the higher center. The Aβ fibers respond better when stimulated at a relatively high rate (in the order of 90–30 Hz or pps) but it is difficult to find support for the concept that there is a single frequency that works best for every patient, this range appears to cover the majority of individuals. An alternative approach is to stimulate the Aβ fibers which respond preferentially to a mode stimulation, which will activate the opioid mechanisms, and provide pain relief by causing the release of an endogenous opiate (encephalin) in the spinal cord. A third possibility is to stimulate both nerve types at the same time by employing burst mode stimulation. In this instance, the higher frequency stimulation output (typically at about 100 Hz) is interrupted (or burst) at the rate of 2 --3 bursts per second. When the machine is ‘on’, it will deliver pulses of the 100 Hz rate, thereby activating the Aβ and the pain gate mechanism, but by virtue of the rate of the burst, each burst will produce excitation in the A-delta fibers, therefore stimulating the opioid mechanisms. For some patients, this is by far the most effective approach to pain relief, though as a sensation, numerous patients find it less acceptable than other forms of TENS [43].
As applied to current study, 60-min cumulative treatment time was applied on PISP patients per session of treatment as against the recommended 20 or 30 min by previous TENS related studies, especially where TENS was used as addictive therapy modality. Consequent upon this, in carrying out this study, the authors were aware of likely depreciating effect of TENS overtimes probably due to adaptation to particular treatment mode and took measures to vary the parameters to minimize or avert it as it can negatively impact its efficiency in pain relief. This agrees with the scientific finding that the benefit of TENS tends to fall with time [4446]. Also, depreciation in value-effect of TENS might be due to the adaptation of the nervous system to regular repetitive stimuli [47, 48]. The clinical implication of this is when TENS is applied for a long time as in current study nerve accommodation takes place and may affect the general efficacy of TENS in pain relief. To overcome anticipated accommodation effect in the current study the authors during treatment of TG patients were swinging between continuous and burst TENS modes [49]. The nerve adaptation and accommodation accounted for why some period after TENS is switched on, the patient complained that he/she is not feeling the buzzing or pulsating sensation well enough. Johnson et al. reported that individual patients used a specific pulse frequency but consistently there was a significant variation in the pulse frequency used by different patients [50]. The authors were also mindful of selecting the time of TENS applications because the stimulating effect does not start immediately but needs some time before its cumulative effect would be felt, this is in line with the outcome of experimental studies reported by previous authors [51, 52].
In the current study, from Table 2, there was a significant difference (p < 0.05) between the test and control groups for age and duration of symptom at baseline, this difference in baseline the authors noted could possibly have influenced the outcome of the study but no literature to back it up. Table 2 revealed no significant difference (p > 0.05) in the subjects’ baseline mean values of height, weight, and VAS between the test and control groups, this the authors assumed did not influence the outcome of this study.
Moreover, deductions from the subjects’ recruitment flowchart (Fig. 5) showed more subjects in the CG either absconded or were irregular with treatment compared to what obtained in the TG. These differences might be attributed not only to a single factor but a variety of possible factors like not having the desired relief from pain, having good relief after few days of application of TENS, socio-economic and other considerations that are not within the immediate capacity of the authors to discern. Significantly, however, 40 of 55 subjects (73%) conveniently allotted to test group completed the study. Also, 32 of 55 subjects (58%) conveniently allotted to the control group completed the study.
The strength of the study lies in the use of VAS which is still generally accepted as a good tool for measuring variations in pain perception, the cost-effective nature of the measuring tool, the cooperation of the authors and the seemingly novel nature of the study which highlighted the application of TENS as a monotherapy treatment tool and one-hour application TENS for management of PISP.
The current study was however weakened by non-randomization of the samples, low sample size relative to the calculated sample size; the possibility that subjects in the groups still ingested one form of analgesic medication or the other; the subjective nature of pain assessment tool used, and the fact that the treatment modes of intensity, frequency and pulse width which varied amongst participants, and time did not provide for equal treatment of participants using a uniformed parameter. Furthermore, the significant differences in baseline VAS scores between age and duration of symptom could have influenced the outcome of the study.

Conclusions

The outcome of the study showed significant improvement in PISP after 10 weeks TENS application. It also shows that STENS also achieved varied pain relief to control subjects but not significant enough to compare the effect of TENS on the test group. This has shown the usefulness of TENS in managing PISP of sub-acute and chronic nature. The implication for management and rehabilitation is that TENS alone is beneficial in the management of injection-related nerve pain as demonstrated from the outcome of the current study. A future line of study is consideration of comparative effects of TENS and TENS in combination in the management of PISP. Also, future studies that should factor the limitations highlighted above are advocated by the authors as it will help to strengthen quality, acceptability, and generalizability of the study outcome.

Acknowledgments

All the staff and members of the Department of Physiotherapy, NAUTH, Nnewi, and Landmark Physiotherapy Services are well appreciated for their support and encouragement.

Funding

No form of funding was received from any source.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Ethics approval was obtained from the Nnamdi Azikiwe Univerity Teaching Hospital Ethics Committee and informed consent obtained from participants before the commencement of the study. The consent obtained from participants was written.
Consent for publication was obtained from the patient that appeared in Figs. 1, 2 and 3.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Kline, DG, Kim, D Midha, R. (1998). Management and results of sciatic nerve injuries: a 24-year experience. J Neurosurg 1998; 80; 13–23. Kline, DG, Kim, D Midha, R. (1998). Management and results of sciatic nerve injuries: a 24-year experience. J Neurosurg 1998; 80; 13–23.
2.
Zurück zum Zitat Tak SR, Dar GN, Halwai MA. Post-injection nerve injuries in kasmir: a menace overlooked. J Res Med Sci. 2008;13:244–7. Tak SR, Dar GN, Halwai MA. Post-injection nerve injuries in kasmir: a menace overlooked. J Res Med Sci. 2008;13:244–7.
3.
Zurück zum Zitat Arnozan, quoted by Wexburg E. Neuritis and polyneuritis (1835). In: Bumke O, Foerter O, editors. Handbuch der neurologie, vol 9. Berlin: Springer-Verlag; 1935. p. 87. Arnozan, quoted by Wexburg E. Neuritis and polyneuritis (1835). In: Bumke O, Foerter O, editors. Handbuch der neurologie, vol 9. Berlin: Springer-Verlag; 1935. p. 87.
4.
Zurück zum Zitat Turner GG. The site for intramuscular injections. Lancet. 1929;196:819.CrossRef Turner GG. The site for intramuscular injections. Lancet. 1929;196:819.CrossRef
5.
Zurück zum Zitat Mishra P, Stringer MD. Sciatic nerve injury from intramuscular injection: a persistent and global problem. Int J Clin Pract. 2010;64:1573–9.CrossRef Mishra P, Stringer MD. Sciatic nerve injury from intramuscular injection: a persistent and global problem. Int J Clin Pract. 2010;64:1573–9.CrossRef
7.
Zurück zum Zitat Small SP. Preventing sciatic nerve injury from intramuscular injections literature review. J Adv Nurs. 2004;47:287–96.CrossRef Small SP. Preventing sciatic nerve injury from intramuscular injections literature review. J Adv Nurs. 2004;47:287–96.CrossRef
10.
Zurück zum Zitat Sluka KA. The basic science of TENS and clinical implications. Article, pg 1; 2000. Sluka KA. The basic science of TENS and clinical implications. Article, pg 1; 2000.
11.
Zurück zum Zitat Acute Pain Management Guideline Panel. Acute pain management: operative or medical procedures and trauma: a clinical practice guideline. No. 1. Rockville, Md.: Agency for Health Care Policy and Research, 1992. (AHCPR publication no. 92–0032.) Acute Pain Management Guideline Panel. Acute pain management: operative or medical procedures and trauma: a clinical practice guideline. No. 1. Rockville, Md.: Agency for Health Care Policy and Research, 1992. (AHCPR publication no. 92–0032.)
13.
Zurück zum Zitat Robison AJ, Snyder-macker L. Clinical electrophysiology: electrotherapy and electrophysiology testing. 3rd ed. Baltimore: Williamson Wilkins; 1995. Robison AJ, Snyder-macker L. Clinical electrophysiology: electrotherapy and electrophysiology testing. 3rd ed. Baltimore: Williamson Wilkins; 1995.
14.
Zurück zum Zitat Katz J, Melzack. R. (1999). Measurement of pain. Surg Clin North Am. 1999 Apr; 79(2):231–252. Katz J, Melzack. R. (1999). Measurement of pain. Surg Clin North Am. 1999 Apr; 79(2):231–252.
15.
Zurück zum Zitat Scott J, Huskisson EC. Graphic representation of pain. Pain. 1976;2:175–84.CrossRef Scott J, Huskisson EC. Graphic representation of pain. Pain. 1976;2:175–84.CrossRef
16.
Zurück zum Zitat Carlsson AM. Assessment of chronic pain. Aspects of the Reliability and Validity of the Visual Analogue Scale. Pain. 1983;16(1):87–101.CrossRef Carlsson AM. Assessment of chronic pain. Aspects of the Reliability and Validity of the Visual Analogue Scale. Pain. 1983;16(1):87–101.CrossRef
17.
Zurück zum Zitat Kumar D, Marshall HJ. Diabetic peripheral neuropathy: amelioration of pain with transcutaneous electrostimulation. Diabetes Care. 1997;20(11):1702–5.CrossRef Kumar D, Marshall HJ. Diabetic peripheral neuropathy: amelioration of pain with transcutaneous electrostimulation. Diabetes Care. 1997;20(11):1702–5.CrossRef
18.
Zurück zum Zitat Kumar VN, Red Ford. TENS in rheumatoid arthritis. Arch Phys Rehabil. 1982;63:595–6. Kumar VN, Red Ford. TENS in rheumatoid arthritis. Arch Phys Rehabil. 1982;63:595–6.
19.
Zurück zum Zitat Finsen V, Persen L, Lovlien M, et al. Transcutaneous electrical nerve stimulation after major amputation. J Bone Joint Surg Br 1988. 1988;70(1):109–12.CrossRef Finsen V, Persen L, Lovlien M, et al. Transcutaneous electrical nerve stimulation after major amputation. J Bone Joint Surg Br 1988. 1988;70(1):109–12.CrossRef
20.
Zurück zum Zitat Katz J, Melzack R. Auricular transcutaneous electrical nerve stimulation (TENS) reduces phantom limb pain. J Pain Symptom Manag. 1991;6(2):73–83.CrossRef Katz J, Melzack R. Auricular transcutaneous electrical nerve stimulation (TENS) reduces phantom limb pain. J Pain Symptom Manag. 1991;6(2):73–83.CrossRef
21.
Zurück zum Zitat Fatunde OJ, Familusi JB. Injection-induced sciatic nerve injury in Nigerian children. Cent Afr J Med. 2001;47(2):35–8.PubMed Fatunde OJ, Familusi JB. Injection-induced sciatic nerve injury in Nigerian children. Cent Afr J Med. 2001;47(2):35–8.PubMed
22.
Zurück zum Zitat Daniel WW. Biostatistics. A foundation for analysis in the health sciences 7th edition. New York: John Wily and Sons; 1999. Daniel WW. Biostatistics. A foundation for analysis in the health sciences 7th edition. New York: John Wily and Sons; 1999.
23.
Zurück zum Zitat Lwanga SK, Lemeshow S. Sample size determination in health studies: a practical manual. Geneva: World Health Organization; 1999. Lwanga SK, Lemeshow S. Sample size determination in health studies: a practical manual. Geneva: World Health Organization; 1999.
24.
Zurück zum Zitat Naing L, Winn T, Rusli BN. Practical issues in calculating the sample size for prevalence studies. Arch Orofac Sci. 2006;1:9–14. Naing L, Winn T, Rusli BN. Practical issues in calculating the sample size for prevalence studies. Arch Orofac Sci. 2006;1:9–14.
25.
Zurück zum Zitat Ali J, Yaffe CS, Sessle BJ. The effect of transcutaneous electrical nerve stimulation on postoperative pain and pulmonary function. Surgery. 1981;89:507–12.PubMed Ali J, Yaffe CS, Sessle BJ. The effect of transcutaneous electrical nerve stimulation on postoperative pain and pulmonary function. Surgery. 1981;89:507–12.PubMed
26.
Zurück zum Zitat Price DC, Megrath PA, Rafii A. The validation of visual analog scales as rational scale measures for chronic and experimented pain. Pain. 1983;17:45–56.CrossRef Price DC, Megrath PA, Rafii A. The validation of visual analog scales as rational scale measures for chronic and experimented pain. Pain. 1983;17:45–56.CrossRef
27.
Zurück zum Zitat Abelson K, Langley GB, Vilieg M, Wigley RD. Transcutaneous electrical nerve stimulation in rheumatoid arthritis. N Z Med J. 1983;96:156–8.PubMed Abelson K, Langley GB, Vilieg M, Wigley RD. Transcutaneous electrical nerve stimulation in rheumatoid arthritis. N Z Med J. 1983;96:156–8.PubMed
28.
Zurück zum Zitat Levy, A, Dalith, M, Abramovici, A, Pinkhand, J., Weinberger, A. (1997). TENS in experimental acute arthritis of physical medicine and Rehabilitation pp 68, 75–78. Levy, A, Dalith, M, Abramovici, A, Pinkhand, J., Weinberger, A. (1997). TENS in experimental acute arthritis of physical medicine and Rehabilitation pp 68, 75–78.
29.
Zurück zum Zitat Mannheimer C, Lund S, Carlsson CA. The effect of TENS on joint pain in patients with rheumatoid arthritis. Scand J Rheumatol. 1978;7(1):13–6.PubMed Mannheimer C, Lund S, Carlsson CA. The effect of TENS on joint pain in patients with rheumatoid arthritis. Scand J Rheumatol. 1978;7(1):13–6.PubMed
30.
Zurück zum Zitat Reitman C, Esses SI. Conservative options in the management of spinal disorders. Part 1: bed rest, mechanical and energy transfer therapies. Am J Orthop. 1995;24:109–16.PubMed Reitman C, Esses SI. Conservative options in the management of spinal disorders. Part 1: bed rest, mechanical and energy transfer therapies. Am J Orthop. 1995;24:109–16.PubMed
31.
Zurück zum Zitat Robinson AJ. TENS for the control of pain in musculoskeletal disorders journal of orthopedics and sports. Phys Ther. 1996;24:204–27. Robinson AJ. TENS for the control of pain in musculoskeletal disorders journal of orthopedics and sports. Phys Ther. 1996;24:204–27.
32.
Zurück zum Zitat Johnson MI, Ashton CH, Thompson JW. An in-depth study of long-term uses of TENS. Implications for Clinical use of TENS on pain. 1991;44:221–9.PubMed Johnson MI, Ashton CH, Thompson JW. An in-depth study of long-term uses of TENS. Implications for Clinical use of TENS on pain. 1991;44:221–9.PubMed
33.
Zurück zum Zitat Oya T et al (2004). Journal of Back and Musculoskeletal Rehabilitation Vol. 17 number 34 pg. 127–133. Oya T et al (2004). Journal of Back and Musculoskeletal Rehabilitation Vol. 17 number 34 pg. 127–133.
34.
Zurück zum Zitat Fisbian V, Persen L, Lovlien M, et al. Transcutaneous electrical nerve stimulation after major amputation. J Bone Joint Surg Br. 1988;70(1):109–12. Fisbian V, Persen L, Lovlien M, et al. Transcutaneous electrical nerve stimulation after major amputation. J Bone Joint Surg Br. 1988;70(1):109–12.
35.
Zurück zum Zitat White PF, Jennifer Philips BS, Timothy JP, William FC. Percutaneous Electrical Nerve Stimulation (PENS) A Promising Alternative Medicine Approach to pain management; 1999. White PF, Jennifer Philips BS, Timothy JP, William FC. Percutaneous Electrical Nerve Stimulation (PENS) A Promising Alternative Medicine Approach to pain management; 1999.
36.
Zurück zum Zitat Meechan JG, Gowans AJ, Welbury RR. (1998). The use of patient-controlled transcutaneous electrical nerve stimulation (TENS) to decrease the discomfort of regional anesthesia in dentistry: a randomized trial. J Dent 1998;26(5–6):417–420. Meechan JG, Gowans AJ, Welbury RR. (1998). The use of patient-controlled transcutaneous electrical nerve stimulation (TENS) to decrease the discomfort of regional anesthesia in dentistry: a randomized trial. J Dent 1998;26(5–6):417–420.
37.
Zurück zum Zitat Soo-Ampon S, Vongsavan N, Apai W. (1997). Effect of TENS on experimentally induced dental pain. J Dent Res 1997; 76:59. Soo-Ampon S, Vongsavan N, Apai W. (1997). Effect of TENS on experimentally induced dental pain. J Dent Res 1997; 76:59.
38.
Zurück zum Zitat Harvey M, Elliott M. Transcutaneous electrical nerve stimulation (TENS) for pain management during cavity preparations in pediatric patients. ASDC J Dent Child. 1995;62(1):49–51.PubMed Harvey M, Elliott M. Transcutaneous electrical nerve stimulation (TENS) for pain management during cavity preparations in pediatric patients. ASDC J Dent Child. 1995;62(1):49–51.PubMed
39.
Zurück zum Zitat Cheing GL, Hui-Chan CW, Chan KM. Do four weeks of TENS and/or isometric exercise produce a cumulative reduction of osteoarthritic knee pain? Clin Rehabil. 2002;16(7):749–60.CrossRef Cheing GL, Hui-Chan CW, Chan KM. Do four weeks of TENS and/or isometric exercise produce a cumulative reduction of osteoarthritic knee pain? Clin Rehabil. 2002;16(7):749–60.CrossRef
40.
Zurück zum Zitat Mannheimer C, Emanuelsson H, Waagstein F, et al. Influence of naloxone on the effects of high frequency transcutaneous electrical nerve stimulation in angina pectoris induced by atrial pacing. Br Heart J. 1989;62(1):36–42.CrossRef Mannheimer C, Emanuelsson H, Waagstein F, et al. Influence of naloxone on the effects of high frequency transcutaneous electrical nerve stimulation in angina pectoris induced by atrial pacing. Br Heart J. 1989;62(1):36–42.CrossRef
41.
Zurück zum Zitat Jarzem P, Harvey EJ, Arcaro N, Kazaronski J. Transcutaneous electrical nerve stimulation fir nonacute low back pain: a non- randomized double-blind study of conventional, Nu- wave form acupuncture- type and sham therapies. 1997. Cochranelibrary- wily.com/ doi/epdf. Jarzem P, Harvey EJ, Arcaro N, Kazaronski J. Transcutaneous electrical nerve stimulation fir nonacute low back pain: a non- randomized double-blind study of conventional, Nu- wave form acupuncture- type and sham therapies. 1997. Cochranelibrary- wily.com/ doi/epdf.
42.
Zurück zum Zitat Carroll D, Moore RA, McQuay HJ, et al. Transcutaneous electrical nerve stimulation (TENS) for chronic pain; (3): (Cochrane review). Cochrane Database Syst Rev. 2001;4:CD003222. Carroll D, Moore RA, McQuay HJ, et al. Transcutaneous electrical nerve stimulation (TENS) for chronic pain; (3): (Cochrane review). Cochrane Database Syst Rev. 2001;4:CD003222.
43.
Zurück zum Zitat Ellis J. A retrospective study of long-term users of TENS. Br J Ther Rehabil. 1996;3(2):88–93.CrossRef Ellis J. A retrospective study of long-term users of TENS. Br J Ther Rehabil. 1996;3(2):88–93.CrossRef
44.
Zurück zum Zitat Loeser JD, Back RG, Christma A. Relief of by TENS. J Neurosurg. 1975;42:308–14.CrossRef Loeser JD, Back RG, Christma A. Relief of by TENS. J Neurosurg. 1975;42:308–14.CrossRef
45.
Zurück zum Zitat Taylor, PI, Haliott, M, Faberty Faberty H. (1981). Treatment of OA of the knee with TENS Pg. 233–246.Tinegate H, McLelland J (2002). Correspondence. Clin Lab Hematol 24(6):389–390. Taylor, PI, Haliott, M, Faberty Faberty H. (1981). Treatment of OA of the knee with TENS Pg. 233–246.Tinegate H, McLelland J (2002). Correspondence. Clin Lab Hematol 24(6):389–390.
46.
Zurück zum Zitat Bates JAV, Nathan PW. Transcutaneous electrical nerve stimulation for chronic pain. Anesthesia. 1980;35:817.CrossRef Bates JAV, Nathan PW. Transcutaneous electrical nerve stimulation for chronic pain. Anesthesia. 1980;35:817.CrossRef
47.
Zurück zum Zitat Thompson JN. The role of TENS for the control of pain. In: Doyle D, editor. International symposium on pain control. London: Royal Society of Medical Services; 1987. p. 27–47. Thompson JN. The role of TENS for the control of pain. In: Doyle D, editor. International symposium on pain control. London: Royal Society of Medical Services; 1987. p. 27–47.
48.
Zurück zum Zitat Pameranze B, Nizmick G. Codetron a new electrotherapy devil overcomes habituation problems of Conventional TENS devices, AMJ Electro Med. First Quarter 22–26. Loy. 1991; 1987. Pameranze B, Nizmick G. Codetron a new electrotherapy devil overcomes habituation problems of Conventional TENS devices, AMJ Electro Med. First Quarter 22–26. Loy. 1991; 1987.
49.
Zurück zum Zitat Frampton VM. TENS Clayton’s electrotherapy 10th edition; 1998. p. 77–88. Frampton VM. TENS Clayton’s electrotherapy 10th edition; 1998. p. 77–88.
50.
Zurück zum Zitat Johnson MI, Ashton CH, Thompson JW. The consistency of pulse frequency and pulse patterns of transcutaneous electrical nerve stimulation (TENS) used by chronic pain patients. Pain. 1991;44:231–29.CrossRef Johnson MI, Ashton CH, Thompson JW. The consistency of pulse frequency and pulse patterns of transcutaneous electrical nerve stimulation (TENS) used by chronic pain patients. Pain. 1991;44:231–29.CrossRef
51.
Zurück zum Zitat Sjolund B, Erikesson MBH. The influence of naloxone analgesia produced by peripheral conditioning stimulation. Brain Res. 1979;173:295–301.CrossRef Sjolund B, Erikesson MBH. The influence of naloxone analgesia produced by peripheral conditioning stimulation. Brain Res. 1979;173:295–301.CrossRef
52.
Zurück zum Zitat Woolfe SI, Gersh HR, Rao VR. Examination of electrodes placement and Stimulation parameters in treating chronic pain with conventional transcutaneous electrical nerve stimulation (TENS). Pain. 1981;11(1):37–47.CrossRef Woolfe SI, Gersh HR, Rao VR. Examination of electrodes placement and Stimulation parameters in treating chronic pain with conventional transcutaneous electrical nerve stimulation (TENS). Pain. 1981;11(1):37–47.CrossRef
Metadaten
Titel
Effects of transcutaneous electrical nerve stimulation in the Management of Post-Injection Sciatic Pain in a non-randomized controlled clinical trial in Nnewi, Nigeria
verfasst von
Uchenna Prosper Okonkwo
Sam Chidi Ibeneme
Ebere Yvonne Ihegihu
Afamefuna Victor Egwuonwu
Ikechukwu Charles Ezema
Adesina Fatai Maruf
Emmanuel Chiebuka Okoye
Olanrewaju Peter Ibikunle
Antoninus Obinna Ezeukwu
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
BMC Complementary Medicine and Therapies / Ausgabe 1/2018
Elektronische ISSN: 2662-7671
DOI
https://doi.org/10.1186/s12906-018-2373-8

Weitere Artikel der Ausgabe 1/2018

BMC Complementary Medicine and Therapies 1/2018 Zur Ausgabe