Skip to main content
Erschienen in: Journal of Medical Case Reports 1/2010

Open Access 01.12.2010 | Case report

Enterobacter cloacae infection of an expanded polytetrafluoroethylene femoral-popliteal bypass graft: a case report

verfasst von: Ian Musil, Vanessa Jensen, Jolyon Schilling, Boyd Ashdown, Tyler Kent

Erschienen in: Journal of Medical Case Reports | Ausgabe 1/2010

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Introduction

Enterobacter cloacae infections are common among burn victims, immunocompromised patients, and patients with malignancy. Most commonly these infections are manifested as nosocomial urinary tract or pulmonary infections. Nosocomial outbreaks have also been associated with colonization of certain surgical equipment and operative cleaning solutions. Infections of an aortobifemoral prosthesis, an aortic graft, and arteriovenous fistulae are noted in the literature. To our knowledge, this is the first isolated account of an E. cloacae infection of a femoral-popliteal expanded polytetrafluoroethylene bypass graft.

Case presentation

A 68-year-old Caucasian man presented with fever and rest pain in the right lower extremity five months after the placement of a vascular expanded polytetrafluoroethylene graft for femoral-popliteal bypass. Computed tomography angiography demonstrated peri-graft fluid that was aspirated percutaneously with image guidance and cultured to reveal E. cloacae. The graft was revised and then removed. The patient completed a six-week course of ceftazidime and is currently without signs of infection. There were no other reports of E. cloacae graft infections in any patients receiving treatment in the same surgical suite within a month of this report.

Conclusion

Isolated cases of E. cloacae infection of surgical bypass grafts are rare (unique in this setting). Clinicians should have a high index of suspicion for device contamination in such cases and should consider testing for possible microbial reservoirs. Graft removal is required due to the formation of biofilm and the recent emergence of Enterobacteriaceae producing extended-spectrum beta-lactamase in community acquired infections.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1752-1947-4-131) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

VJ analyzed and interpreted the patient data regarding the vascular graft infection and was a major contributor in writing the manuscript. JS removed the graft, performed common femoral artery, and performed a saphenous vein patch of the common femoral artery. JS was also a major contributor in writing the manuscript. IM analyzed the patient's medical history and all patient labs and imaging studies, as well as contacting the patient for consent. IM was the major contributor to writing the manuscript. All authors read and approved the final manuscript.

Introduction

Enterobacter cloacae infections are seen commonly in burn victims, immunocompromised patients, and patients with malignancy [1]. The urinary and pulmonary systems are the organ systems most commonly colonized in these patients. E. cloacae bacteremia can also occur depending on the extent of immunocompromise.
Outbreaks of coloacae infections are recorded in a number of hospital settings. Sporadic cases of E. cloacae infections have been linked to contaminated admixed intravenous fluids, total parenteral nutrition solutions, enteral feedings, infant formula, cardioplegic solution, and blood products [24]. Another potential reservoir for nosocomial bacteremia is the heparin flush solution used to irrigate certain intravascular devices continually. This fluid had been implicated as a reservoir for outbreaks of device-associated bacteremia in several instances [5].
Less commonly, outbreaks are linked to the colonization of devices such as long-term tunneled hemodialysis catheters. Buxton and colleagues reported an epidemic of E. cloacae infections that was associated with disposable transducer domes. During their initial setup the chambers and domes were contaminated by the hands of hospital personal who had handled contaminated transducer heads [6]. West and colleagues also reported E. cloacae sepsis resulting from transducer dome cracks. In this study, disposable transducer domes were being re-sterilized with resultant cracks in the dome membrane holding bacteria. Case series also document the colonization of entire operative suites that require extensive decontamination [4].

Case presentation

A 68-year-old male presents to a rural clinic with a two-week history of claudication and a one-day history of rest pain and fever. His past medical history was relevant for lower extremity arterial insufficiency and claudication in his right leg for which he underwent a right femoral-popliteal above the knee bypass using a 6mm expanded polytetrafluoroethylene (ePTFE) graft in May 2007. The graft was revised a month later in July 2007 when surveillance ultrasound revealed an occlusion. Intra-operative findings at that presentation included extensive calcific atherosclerotic disease and aggressive intimal hyperplasia in the popliteal artery. A small seroma around the distal anastomosis was discovered and evacuated at that time. There was no evidence of graft infection after thrombectomy and revision. Our patient was started on coumadin to maintain graft patency. His initial recovery was unremarkable.
Four months later, our patient began to experience claudication for two weeks and then developed rest pain and fever. He did not display any tissue loss or sensory changes. On physical exam, our patient's distal incision was warm and slightly indurated. His temperature was 38.5°C. Pedal pulses were 2+ in the left extremity and could not be palpated on the right.
Computed tomography angiography (CTA) of our patient (Figure 1) revealed a peri-graft fluid collection in the popliteal fossa of the right lower extremity and an occluded femoral-popliteal graft. Our patient's white blood cell count was 9000 cells with a 73% neutrophilia and his sedimentation rate was 64 Westergren units (mm/h). A CT-guided aspiration of the peri-graft fluid (Figure 2) was cultured and revealed E. cloacae with sensitivity to extended-spectrum cephalosporins, including cefepime, cefpirome, and cefclidine. At that time, our patient was started on a third generation cephalosporin, 1g intravenous ceftazidime every eight hours.
Six hours later, the patient underwent removal of the graft. Endarterectomy with saphenous vein patch angioplasty was performed on the common femoral artery for severe atherosclerotic stenosis. Collaterals from the deep femoral artery were relied upon to perfuse the limb. Our patient completed a six-week course of ceftazidime, currently uses the limb without discomfort, and is without signs of infection.

Discussion

Synthetic peripheral bypass vascular grafts carry a high morbidity [7]. The risk of complications is as high as 50% in some studies. These risks include hemorrhage, limb ischemia, amputation, revision, or infection [7, 8]. Rates for peripheral lower extremity prosthetic graft infection are as high as 12% [7]. Risk factors for graft infection are similar to those for wound infection and include obesity, diabetes, cancer and other immunocompromised states, as well as the use of immunosuppressive therapies. Our patient had a history of lung cancer in remission, but was without other risk factors.
The most common pathogen in graft infection is Staphylococcus aureus, which is responsible for 35% of graft infections. Gram-negative rods account for another 20% of vascular graft infections. Other common organisms in these infections include coagulase negative Staphylococcus, Streptococcus milleri, Enterococcus faecium, Escherichia coli, Bacteroides fragilis, Candida albicans and Pseudomonus aeruginosa. Polymicrobial colonization is commonly seen in immunocompromised patients. Grafts that require groin incisions have the greatest risk for infection, possibly due to contamination by bowel flora at the time of implantation [9].
Nosocomial E. cloacae infections are not entirely uncommon. Their isolated occurrence among vascular prosthetic grafts is rare, however. There are accounts of E. cloacae infection of an aortobifemoral bypass prosthesis and reports of E. cloacae infection in other types of vascular grafts (including an aortic graft), but, to our knowledge, this is the first account of an E. cloacae infection in a femoral-popliteal ePTFE bypass graft [10, 11]. ePTFE is a woven form of PTFE, the same polymer used in Teflon© (DuPont). Research demonstrates this material is particularly prone to infection and biofilm formation relative to autologous tissues [12].
From the clinical perspective, biofilms are a major problem, since these structures display greatly increased resistance to physical and chemical insults. Crucially, biofilms are resistant to antibiotic treatment, making them particularly difficult to eliminate from patients and contaminated surgical equipment [13]. Several case reports, as well as larger studies from Canada, France, Israel, Spain, Italy and the UK indicate that infections caused by extended spectrum Beta-lactamase (ESBL) Enterobacteriaceae is an emerging problem in outpatient settings [15]. Therefore, graft removal should always be considered.
Prosthetic vascular graft infections commonly occur without specific symptoms [14]. Some authors suggest surveillance in the absence of clinical symptoms with the use of indium scan to identify infection. Clinical symptoms arose in this patient before surveillance could be conducted. When signs and symptoms are present, diagnoses of graft infection is still difficult and must often rely on clinical basis alone as blood cultures are often negative [16]. Most authors suggest the use of CTA as the most appropriate study to identify infection when clinical suspicion is high [17]. Peri-graft fluid, ectopic air, abnormal tissue planes or soft tissue swelling, and pseudoaneurysm formation are all signs of graft infection on CT. Non-specific findings include fever, leukocytosis with left shift, and elevated inflammation markers (erythrocyte sedimentation rate, ESR; C-reactive protein, CRP). Absence of other signs of graft infection should prompt a thorough workup for other causes. CTA was used to identify the nidus of infection in our patient.
Management requires resection of the infected graft, arterial repair or bypass with autologous tissue, and long-term antibiotics [18]. Placement of a new prosthetic graft should be avoided in the presence of acute infection. Adjuvant techniques of endarterectomy or percutaneous revascularization may be helpful. The importance of standard hospital and operating room hygiene measures (disinfection of hands) must not be underestimated. These measures are paramount to the control and prevention of infection. When an isolated surgical case of E. cloacae occurs, clinicians should have a high index of suspicion for device contamination, consider testing for possible microbial reservoirs, and also consider documenting the case in the literature [14].

Conclusions

Currently, our patient experiences mild claudication, but no rest pain. He has no evidence of infection following the removal of his ePTFE graft, endarterectomy of the common femoral artery, saphenous vein patch, and intravenous ceftazidime. Additionally, there are no records of E. cloacae infection of any other patient at this hospital within a month of original graft placement. This makes widespread contamination of surgical equipment unlikely.
Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://​creativecommons.​org/​licenses/​by/​2.​0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

VJ analyzed and interpreted the patient data regarding the vascular graft infection and was a major contributor in writing the manuscript. JS removed the graft, performed common femoral artery, and performed a saphenous vein patch of the common femoral artery. JS was also a major contributor in writing the manuscript. IM analyzed the patient's medical history and all patient labs and imaging studies, as well as contacting the patient for consent. IM was the major contributor to writing the manuscript. All authors read and approved the final manuscript.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Allgemeinmedizin

Kombi-Abonnement

Mit e.Med Allgemeinmedizin erhalten Sie Zugang zu allen CME-Fortbildungen und Premium-Inhalten der allgemeinmedizinischen Zeitschriften, inklusive einer gedruckten Allgemeinmedizin-Zeitschrift Ihrer Wahl.

Anhänge

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.
Literatur
1.
Zurück zum Zitat Rodriguez Jornet A, Garcia Garcia M, Mariscal D, Fontanals D, Cortes P, Coll P: An outbreak of gram-negative bacteremia (GNB), especially enterobacter cloacae, in patients with long-term tunnelled haemodialysis catheters. Nefrologia. 2003, 23 (4): 333-343.PubMed Rodriguez Jornet A, Garcia Garcia M, Mariscal D, Fontanals D, Cortes P, Coll P: An outbreak of gram-negative bacteremia (GNB), especially enterobacter cloacae, in patients with long-term tunnelled haemodialysis catheters. Nefrologia. 2003, 23 (4): 333-343.PubMed
2.
Zurück zum Zitat Andersen BM, Sorlie D, Hotvedt R, Almdahl SM, Olafsen K, George R: Multiply beta-lactam resistant enterobacter cloacae infections linked to the environmental flora in a unit for cardiothoracic and vascular surgery. Scand J Infect Dis. 1989, 21 (2): 181-191. 10.3109/00365548909039967.CrossRefPubMed Andersen BM, Sorlie D, Hotvedt R, Almdahl SM, Olafsen K, George R: Multiply beta-lactam resistant enterobacter cloacae infections linked to the environmental flora in a unit for cardiothoracic and vascular surgery. Scand J Infect Dis. 1989, 21 (2): 181-191. 10.3109/00365548909039967.CrossRefPubMed
3.
Zurück zum Zitat Hughes CF, Grant AF, Leckie BD, Baird DK: Cardioplegic solution: A contamination crisis. J Thorac Cardiovasc Surg. 1986, 91 (2): 296-302.PubMed Hughes CF, Grant AF, Leckie BD, Baird DK: Cardioplegic solution: A contamination crisis. J Thorac Cardiovasc Surg. 1986, 91 (2): 296-302.PubMed
4.
Zurück zum Zitat Ayus JC, Sheikh-Hamad D: Silent infection in clotted hemodialysis access grafts. J Am Soc Nephrol. 1998, 9 (7): 1314-1317.PubMed Ayus JC, Sheikh-Hamad D: Silent infection in clotted hemodialysis access grafts. J Am Soc Nephrol. 1998, 9 (7): 1314-1317.PubMed
5.
Zurück zum Zitat Brothers TE, Von Moll LK, Niederhuber JE, Roberts JA, Walker-Andrews S, Ensminger WD: Experience with subcutaneous infusion ports in three hundred patients. Surg Gynecol Obstet. 1988, 166 (4): 295-301.PubMed Brothers TE, Von Moll LK, Niederhuber JE, Roberts JA, Walker-Andrews S, Ensminger WD: Experience with subcutaneous infusion ports in three hundred patients. Surg Gynecol Obstet. 1988, 166 (4): 295-301.PubMed
6.
Zurück zum Zitat Buxton AE, Anderson RL, Klimek J, Quintiliani R: Failure of disposable domes to prevent septicemia acquired from contaminated pressure transducers. Chest. 1978, 74 (5): 508-513. 10.1378/chest.74.5.508.CrossRefPubMed Buxton AE, Anderson RL, Klimek J, Quintiliani R: Failure of disposable domes to prevent septicemia acquired from contaminated pressure transducers. Chest. 1978, 74 (5): 508-513. 10.1378/chest.74.5.508.CrossRefPubMed
7.
Zurück zum Zitat FitzGerald SF, Kelly C, Humphreys H: Diagnosis and treatment of prosthetic aortic graft infections: Confusion and inconsistency in the absence of evidence or consensus. J Antimicrob Chemother. 2005, 56 (6): 996-999. 10.1093/jac/dki382.CrossRefPubMed FitzGerald SF, Kelly C, Humphreys H: Diagnosis and treatment of prosthetic aortic graft infections: Confusion and inconsistency in the absence of evidence or consensus. J Antimicrob Chemother. 2005, 56 (6): 996-999. 10.1093/jac/dki382.CrossRefPubMed
8.
Zurück zum Zitat Willwerth BM, Waldhausen JA: Infection of arterial prostheses. Surg Gynecol Obstet. 1974, 139 (3): 446-452.PubMed Willwerth BM, Waldhausen JA: Infection of arterial prostheses. Surg Gynecol Obstet. 1974, 139 (3): 446-452.PubMed
9.
Zurück zum Zitat Rubin RH, Fischman AJ, Callahan RJ, Khaw BA, Keech F, Ahmad M: 111In-labeled nonspecific immunoglobulin scanning in the detection of focal infection. N Engl J Med. 1989, 321 (14): 935-940. 10.1056/NEJM198910053211404.CrossRefPubMed Rubin RH, Fischman AJ, Callahan RJ, Khaw BA, Keech F, Ahmad M: 111In-labeled nonspecific immunoglobulin scanning in the detection of focal infection. N Engl J Med. 1989, 321 (14): 935-940. 10.1056/NEJM198910053211404.CrossRefPubMed
10.
Zurück zum Zitat Heyer KS, Modi P, Morasch MD, Matsumura JS, Kibbe MR, Pearce WH, Resnick SA, Eskandari MK: Secondary infections of thoracic and abdominal aortic endografts. J Vasc Interv Radiol. 2009, 20 (2): 173-179. 10.1016/j.jvir.2008.10.032.CrossRefPubMed Heyer KS, Modi P, Morasch MD, Matsumura JS, Kibbe MR, Pearce WH, Resnick SA, Eskandari MK: Secondary infections of thoracic and abdominal aortic endografts. J Vasc Interv Radiol. 2009, 20 (2): 173-179. 10.1016/j.jvir.2008.10.032.CrossRefPubMed
11.
Zurück zum Zitat Botella GF, Gómez LM, Gadea IL, Rubio FL, Cantí CC: Aortoenteric fistula secondary to aortobifemoral prosthesis infection. Anales de Medicina Interna. 2002, 19 (5): 246-250. Botella GF, Gómez LM, Gadea IL, Rubio FL, Cantí CC: Aortoenteric fistula secondary to aortobifemoral prosthesis infection. Anales de Medicina Interna. 2002, 19 (5): 246-250.
12.
Zurück zum Zitat Delorme JM, Guidoin R, Canizales S: Vascular access for hemodialysis: pathologic features of surgically excised Expanded Polytetrafluoroethylene grafts. Ann Vasc Surg. 1992, 6: 517-524. 10.1007/BF02000823.CrossRefPubMed Delorme JM, Guidoin R, Canizales S: Vascular access for hemodialysis: pathologic features of surgically excised Expanded Polytetrafluoroethylene grafts. Ann Vasc Surg. 1992, 6: 517-524. 10.1007/BF02000823.CrossRefPubMed
13.
Zurück zum Zitat Welch M, Mikkelsen H, Swatton JE, Smith D, Thomas GL, Glansdorp FG, Spring DR: Cell-cell communication in Gram-negative bacteria. Mol Biosyst. 2005, 1 (3): 196-202. 10.1039/b505796p.CrossRefPubMed Welch M, Mikkelsen H, Swatton JE, Smith D, Thomas GL, Glansdorp FG, Spring DR: Cell-cell communication in Gram-negative bacteria. Mol Biosyst. 2005, 1 (3): 196-202. 10.1039/b505796p.CrossRefPubMed
14.
Zurück zum Zitat Chow JW, Yu VL, Shlaes DM: Epidemiologic perspectives on enterobacter for the infection control professional. Am J Infect Control. 1994, 22 (4): 195-201. 10.1016/0196-6553(94)90067-1.CrossRefPubMed Chow JW, Yu VL, Shlaes DM: Epidemiologic perspectives on enterobacter for the infection control professional. Am J Infect Control. 1994, 22 (4): 195-201. 10.1016/0196-6553(94)90067-1.CrossRefPubMed
15.
Zurück zum Zitat Johann D, Pitout D, Nordmann P, Laupland KB, Poirel L: Emergence of Enterobacteriaceae producing extended-spectrum ß-lactamases (ESBLs) in the community. J Antimicrobial Chemotherapy. 2005, 56 (1): 52-59. 10.1093/jac/dki166.CrossRef Johann D, Pitout D, Nordmann P, Laupland KB, Poirel L: Emergence of Enterobacteriaceae producing extended-spectrum ß-lactamases (ESBLs) in the community. J Antimicrobial Chemotherapy. 2005, 56 (1): 52-59. 10.1093/jac/dki166.CrossRef
16.
Zurück zum Zitat Treiman GS, Copland S, Yellin AE, Lawrence PF, McNamara RM, Treiman RL: Wound infections involving infrainguinal autogenous vein grafts: A current evaluation of factors determining successful graft preservation. J Vasc Surg. 2001, 33 (5): 948-954. 10.1067/mva.2001.114209.CrossRefPubMed Treiman GS, Copland S, Yellin AE, Lawrence PF, McNamara RM, Treiman RL: Wound infections involving infrainguinal autogenous vein grafts: A current evaluation of factors determining successful graft preservation. J Vasc Surg. 2001, 33 (5): 948-954. 10.1067/mva.2001.114209.CrossRefPubMed
17.
Zurück zum Zitat Wolma FJ, Derrick JR, McCoy J: Management of infected arterial grafts. Am J Surg. 1973, 126 (6): 798-802. 10.1016/S0002-9610(73)80074-1.CrossRefPubMed Wolma FJ, Derrick JR, McCoy J: Management of infected arterial grafts. Am J Surg. 1973, 126 (6): 798-802. 10.1016/S0002-9610(73)80074-1.CrossRefPubMed
18.
Zurück zum Zitat Antonios VS, Noel AA, Steckelberg JM, Wilson WR, Mandrekar JN, Harmsen WS: Prosthetic vascular graft infection: A risk factor analysis using a case-control study. J Infect. 2006, 53 (1): 49-55. 10.1016/j.jinf.2005.10.004.CrossRefPubMed Antonios VS, Noel AA, Steckelberg JM, Wilson WR, Mandrekar JN, Harmsen WS: Prosthetic vascular graft infection: A risk factor analysis using a case-control study. J Infect. 2006, 53 (1): 49-55. 10.1016/j.jinf.2005.10.004.CrossRefPubMed
Metadaten
Titel
Enterobacter cloacae infection of an expanded polytetrafluoroethylene femoral-popliteal bypass graft: a case report
verfasst von
Ian Musil
Vanessa Jensen
Jolyon Schilling
Boyd Ashdown
Tyler Kent
Publikationsdatum
01.12.2010
Verlag
BioMed Central
Erschienen in
Journal of Medical Case Reports / Ausgabe 1/2010
Elektronische ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-4-131

Weitere Artikel der Ausgabe 1/2010

Journal of Medical Case Reports 1/2010 Zur Ausgabe