Abstract

Contemporary medical robotic systems used in urologic surgery usually consist of a computer and a mechanical device to carry out the designated task with an image acquisition module. These systems are typically from one of the two categories: offline or online robots. Offline robots, also known as fixed path robots, are completely automated with pre-programmed motion planning based on pre-operative imaging studies where precise movements within set confines are carried out. Online robotic systems rely on continuous input from the surgeons and change their movements and actions according to the input in real time. This class of robots is further divided into endoscopic manipulators and master–slave robotic systems. Current robotic surgical systems have resulted in a paradigm shift in the minimally invasive approach to complex laparoscopic urological procedures. Future developments will focus on refining haptic feedback, system miniaturization and improved augmented reality and telesurgical capabilities.
Literatur
1.
Zurück zum Zitat Li QH, Zamorano L, Pandya A et al (2002) The application accuracy of the NeuroMate robot—a quantitative comparison with frameless and frame-based surgical localization systems. Comput Aided Surg 7:90PubMed Li QH, Zamorano L, Pandya A et al (2002) The application accuracy of the NeuroMate robot—a quantitative comparison with frameless and frame-based surgical localization systems. Comput Aided Surg 7:90PubMed
2.
Zurück zum Zitat Bargar WL, Bauer A, Borner M (1998) Primary and revision total hip replacement using the Robodoc system. Clin Orthop Relat Res 354:82–91PubMedCrossRef Bargar WL, Bauer A, Borner M (1998) Primary and revision total hip replacement using the Robodoc system. Clin Orthop Relat Res 354:82–91PubMedCrossRef
3.
Zurück zum Zitat Davies BL, Hibberd RD, Ng WS et al (1991) The development of a surgeon robot for prostatectomies. Proc Inst Mech Eng [H] 205:35 Davies BL, Hibberd RD, Ng WS et al (1991) The development of a surgeon robot for prostatectomies. Proc Inst Mech Eng [H] 205:35
4.
Zurück zum Zitat Harris SJ, Arambula-Cosio F, Mei Q et al (1997) The Probot—an active robot for prostate resection. Proc Inst Mech Eng [H] 211:317 Harris SJ, Arambula-Cosio F, Mei Q et al (1997) The Probot—an active robot for prostate resection. Proc Inst Mech Eng [H] 211:317
5.
Zurück zum Zitat Ho G, Ng WS, Teo MY et al (2001) Experimental study of transurethral robotic laser resection of the prostate using the LaserTrode lightguide. J Biomed Opt 6:244PubMedCrossRef Ho G, Ng WS, Teo MY et al (2001) Experimental study of transurethral robotic laser resection of the prostate using the LaserTrode lightguide. J Biomed Opt 6:244PubMedCrossRef
6.
Zurück zum Zitat Rovetta A, Sala R (1995) Execution of robot-assisted biopsies within the clinical context. J Image Guid Surg 1:280PubMedCrossRef Rovetta A, Sala R (1995) Execution of robot-assisted biopsies within the clinical context. J Image Guid Surg 1:280PubMedCrossRef
7.
Zurück zum Zitat Cleary K, Freedman M, Clifford M et al (2001) Image-guided robotic delivery system for precise placement of therapeutic agents. J Control Release 74:363PubMedCrossRef Cleary K, Freedman M, Clifford M et al (2001) Image-guided robotic delivery system for precise placement of therapeutic agents. J Control Release 74:363PubMedCrossRef
8.
Zurück zum Zitat Fichtinger G, DeWeese TL, Patriciu A et al (2002) System for robotically assisted prostate biopsy and therapy with intraoperative CT guidance. Acad Radiol 9:60PubMedCrossRef Fichtinger G, DeWeese TL, Patriciu A et al (2002) System for robotically assisted prostate biopsy and therapy with intraoperative CT guidance. Acad Radiol 9:60PubMedCrossRef
9.
Zurück zum Zitat Wei Z, Wan G, Gardi L et al (2004) Robot-assisted 3D-TRUS guided prostate brachytherapy: system integration and validation. Med Phys 31:539PubMedCrossRef Wei Z, Wan G, Gardi L et al (2004) Robot-assisted 3D-TRUS guided prostate brachytherapy: system integration and validation. Med Phys 31:539PubMedCrossRef
10.
Zurück zum Zitat Krieger A, Susil RC, Menard C et al (2005) Design of a novel MRI compatible manipulator for image guided prostate interventions. IEEE Trans Biomed Eng 52:306PubMedCrossRef Krieger A, Susil RC, Menard C et al (2005) Design of a novel MRI compatible manipulator for image guided prostate interventions. IEEE Trans Biomed Eng 52:306PubMedCrossRef
11.
Zurück zum Zitat Hempel E, Fischer H, Gumb L et al (2003) An MRI-compatible surgical robot for precise radiological interventions. Comput Aided Surg 8:180PubMedCrossRef Hempel E, Fischer H, Gumb L et al (2003) An MRI-compatible surgical robot for precise radiological interventions. Comput Aided Surg 8:180PubMedCrossRef
12.
Zurück zum Zitat Cadeddu JA, Bzostek A, Schreiner S et al (1997) A robotic system for percutaneous renal access. J Urol 158:1589PubMedCrossRef Cadeddu JA, Bzostek A, Schreiner S et al (1997) A robotic system for percutaneous renal access. J Urol 158:1589PubMedCrossRef
13.
Zurück zum Zitat Stoianovici DCK, Patriciu A, Mazilu D, Stanimir A, Craciumoiu N et al (2003) AcuBot: a robot for radiological interventions. IEEE Trans Rob Autom 19:926CrossRef Stoianovici DCK, Patriciu A, Mazilu D, Stanimir A, Craciumoiu N et al (2003) AcuBot: a robot for radiological interventions. IEEE Trans Rob Autom 19:926CrossRef
14.
Zurück zum Zitat Su LM, Stoianovici D, Jarrett TW et al (2002) Robotic percutaneous access to the kidney: comparison with standard manual access. J Endourol 16:471PubMedCrossRef Su LM, Stoianovici D, Jarrett TW et al (2002) Robotic percutaneous access to the kidney: comparison with standard manual access. J Endourol 16:471PubMedCrossRef
15.
Zurück zum Zitat Kasalicky MA, Svab J, Fried M et al (2002) [AESOP 3000—computer-assisted surgery, personal experience]. Rozhl Chir 81:346PubMed Kasalicky MA, Svab J, Fried M et al (2002) [AESOP 3000—computer-assisted surgery, personal experience]. Rozhl Chir 81:346PubMed
16.
Zurück zum Zitat Kobayashi E, Masamune K, Sakuma I et al (1999) A new safe laparoscopic manipulator system with a five-bar linkage mechanism and an optical zoom. Comput Aided Surg 4:182PubMedCrossRef Kobayashi E, Masamune K, Sakuma I et al (1999) A new safe laparoscopic manipulator system with a five-bar linkage mechanism and an optical zoom. Comput Aided Surg 4:182PubMedCrossRef
17.
Zurück zum Zitat Salama IA, Schwaitzberg SD (2005) Utility of a voice-activated system in minimally invasive surgery. J Laparoendosc Adv Surg Tech A 15:443PubMedCrossRef Salama IA, Schwaitzberg SD (2005) Utility of a voice-activated system in minimally invasive surgery. J Laparoendosc Adv Surg Tech A 15:443PubMedCrossRef
18.
Zurück zum Zitat Rafiq A, Moore JA, Zhao X et al (2004) Digital video capture and synchronous consultation in open surgery. Ann Surg 239:567PubMedCrossRef Rafiq A, Moore JA, Zhao X et al (2004) Digital video capture and synchronous consultation in open surgery. Ann Surg 239:567PubMedCrossRef
19.
Zurück zum Zitat Mendez I, Hill R, Clarke D et al (2005) Robotic long-distance telementoring in neurosurgery. Neurosurgery 56:434PubMedCrossRef Mendez I, Hill R, Clarke D et al (2005) Robotic long-distance telementoring in neurosurgery. Neurosurgery 56:434PubMedCrossRef
20.
Zurück zum Zitat Sung GT, Gill IS (2001) Robotic laparoscopic surgery: a comparison of the DA Vinci and Zeus systems. Urology 58:893PubMedCrossRef Sung GT, Gill IS (2001) Robotic laparoscopic surgery: a comparison of the DA Vinci and Zeus systems. Urology 58:893PubMedCrossRef
21.
Zurück zum Zitat Menon M, Shrivastava A, Tewari A (2005) Laparoscopic radical prostatectomy: conventional and robotic. Urology 66:101PubMedCrossRef Menon M, Shrivastava A, Tewari A (2005) Laparoscopic radical prostatectomy: conventional and robotic. Urology 66:101PubMedCrossRef
22.
Zurück zum Zitat Sim HG, Yip SK, Lau WK et al (2004) Early experience with robot-assisted laparoscopic radical prostatectomy. Asian J Surg 27:321PubMedCrossRef Sim HG, Yip SK, Lau WK et al (2004) Early experience with robot-assisted laparoscopic radical prostatectomy. Asian J Surg 27:321PubMedCrossRef
23.
Zurück zum Zitat Sim HG, Yip SKH, Lau WKO, Tan YH, Wong MYC, Cheng CWS (2006) Team-based approach reduces learning curve in robot-assisted laparoscopic radical prostatectomy. Int J Urol (in press) Sim HG, Yip SKH, Lau WKO, Tan YH, Wong MYC, Cheng CWS (2006) Team-based approach reduces learning curve in robot-assisted laparoscopic radical prostatectomy. Int J Urol (in press)
24.
Zurück zum Zitat Kitagawa M, Dokko D, Okamura AM et al (2005) Effect of sensory substitution on suture-manipulation forces for robotic surgical systems. J Thorac Cardiovasc Surg 129:151PubMedCrossRef Kitagawa M, Dokko D, Okamura AM et al (2005) Effect of sensory substitution on suture-manipulation forces for robotic surgical systems. J Thorac Cardiovasc Surg 129:151PubMedCrossRef
25.
Zurück zum Zitat Tang SL, Kwoh CK, Teo MY et al (1998) Augmented reality systems for medical applications. IEEE Eng Med Biol Mag 17:49PubMedCrossRef Tang SL, Kwoh CK, Teo MY et al (1998) Augmented reality systems for medical applications. IEEE Eng Med Biol Mag 17:49PubMedCrossRef
27.
Zurück zum Zitat Marescaux J, Rubino F, Arenas M et al (2004) Augmented-reality-assisted laparoscopic adrenalectomy. Jama 292:2214PubMedCrossRef Marescaux J, Rubino F, Arenas M et al (2004) Augmented-reality-assisted laparoscopic adrenalectomy. Jama 292:2214PubMedCrossRef
28.
Zurück zum Zitat Hongo K, Kobayashi S, Kakizawa Y et al (2002) NeuRobot: telecontrolled micromanipulator system for minimally invasive microneurosurgery-preliminary results. Neurosurgery 51:985PubMedCrossRef Hongo K, Kobayashi S, Kakizawa Y et al (2002) NeuRobot: telecontrolled micromanipulator system for minimally invasive microneurosurgery-preliminary results. Neurosurgery 51:985PubMedCrossRef
29.
Zurück zum Zitat Goto T, Hongo K, Kakizawa Y et al (2003) Clinical application of robotic telemanipulation system in neurosurgery. Case report. J Neurosurg 99:1082PubMedCrossRef Goto T, Hongo K, Kakizawa Y et al (2003) Clinical application of robotic telemanipulation system in neurosurgery. Case report. J Neurosurg 99:1082PubMedCrossRef
30.
Zurück zum Zitat Marescaux J, Leroy J, Gagner M et al (2001) Transatlantic robot-assisted telesurgery. Nature 413:379PubMedCrossRef Marescaux J, Leroy J, Gagner M et al (2001) Transatlantic robot-assisted telesurgery. Nature 413:379PubMedCrossRef
31.
Zurück zum Zitat Marescaux J, Leroy J, Rubino F et al (2002) Transcontinental robot-assisted remote telesurgery: feasibility and potential applications. Ann Surg 235:487PubMedCrossRef Marescaux J, Leroy J, Rubino F et al (2002) Transcontinental robot-assisted remote telesurgery: feasibility and potential applications. Ann Surg 235:487PubMedCrossRef
32.
Zurück zum Zitat Lee BR, Caddedu JA, Janetschek G et al (1998) International surgical telementoring: our initial experience. Stud Health Technol Inform 50:41PubMed Lee BR, Caddedu JA, Janetschek G et al (1998) International surgical telementoring: our initial experience. Stud Health Technol Inform 50:41PubMed
33.
Zurück zum Zitat Lee BR, Png DJ, Liew L et al (2000) Laparoscopic telesurgery between the United States and Singapore. Ann Acad Med Singapore 29:665PubMed Lee BR, Png DJ, Liew L et al (2000) Laparoscopic telesurgery between the United States and Singapore. Ann Acad Med Singapore 29:665PubMed
34.
Zurück zum Zitat Lee BR, Bishoff JT, Janetschek G et al (1998) A novel method of surgical instruction: international telementoring. World J Urol 16:367PubMedCrossRef Lee BR, Bishoff JT, Janetschek G et al (1998) A novel method of surgical instruction: international telementoring. World J Urol 16:367PubMedCrossRef
Metadaten
Titel
Equipment and technology in surgical robotics
verfasst von
Hong Gee Sim
Sidney Kam Hung Yip
Christopher Wai Sam Cheng
Publikationsdatum
01.06.2006
Verlag
Springer-Verlag
Erschienen in
World Journal of Urology / Ausgabe 2/2006
Print ISSN: 0724-4983
Elektronische ISSN: 1433-8726
DOI
https://doi.org/10.1007/s00345-006-0070-6

Weitere Artikel der Ausgabe 2/2006

World Journal of Urology 2/2006 Zur Ausgabe

Adjuvante Immuntherapie verlängert Leben bei RCC

25.04.2024 Nierenkarzinom Nachrichten

Nun gibt es auch Resultate zum Gesamtüberleben: Eine adjuvante Pembrolizumab-Therapie konnte in einer Phase-3-Studie das Leben von Menschen mit Nierenzellkarzinom deutlich verlängern. Die Sterberate war im Vergleich zu Placebo um 38% geringer.

Bei Senioren mit Prostatakarzinom auf Anämie achten!

24.04.2024 DGIM 2024 Nachrichten

Patienten, die zur Behandlung ihres Prostatakarzinoms eine Androgendeprivationstherapie erhalten, entwickeln nicht selten eine Anämie. Wer ältere Patienten internistisch mitbetreut, sollte auf diese Nebenwirkung achten.

Stufenschema weist Prostatakarzinom zuverlässig nach

22.04.2024 Prostatakarzinom Nachrichten

Erst PSA-Test, dann Kallikrein-Score, schließlich MRT und Biopsie – ein vierstufiges Screening-Schema kann die Zahl der unnötigen Prostatabiopsien erheblich reduzieren: Die Hälfte der Männer, die in einer finnischen Studie eine Biopsie benötigten, hatte einen hochgradigen Tumor.

Harnwegsinfektprophylaxe: Es geht auch ohne Antibiotika

20.04.2024 EAU 2024 Kongressbericht

Beim chronischen Harnwegsinfekt bei Frauen wird bisher meist eine Antibiotikaprophylaxe eingesetzt. Angesichts der zunehmenden Antibiotikaresistenz erweist sich das Antiseptikum Methenamin-Hippurat als vielversprechende Alternative, so die Auswertung einer randomisierten kontrollierten Studie.

Update Urologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.