Evaluation of fetal foramen ovale blood flow by pulsed Doppler ultrasonography combined with spatiotemporal image correlation

To define the normal reference range of fetal foramen ovale blood volume for each gestational age: a cross-sectional study

verfasst von: Wenjuan Tang, Yuanchen Luo, Shi Zeng, Jiawei Zhou, Ganqiong Xu, Jianwen Yang

Erschienen in: Cardiovascular Ultrasound | Ausgabe 1/2021

Abstract

Objective

The objective of this study was to determine fetal foramen ovale blood flow utilizing pulsed Doppler combined with spatiotemporal image correlation.

Methods

A cross-sectional study was performed in 440 normal fetuses between 20 and 40 weeks of gestation. In order to calculate foramen ovale blood flow, the foramen ovale flow velocity–time integral was obtained by pulsed Doppler ultrasonography, and the foramen ovale area was measured by using spatiotemporal image correlation rendering mode. Foramen ovale blood flow was calculated as the product of the foramen ovale area and the velocity–time integral.

Results

Gestational age-specific reference ranges are given for the absolute blood flow (ml/min) of foramen ovale, showing an exponential increase from 20 to 30 weeks of gestation, and a flat growth trend during the last trimester, while the weight-indexed flow (ml/min/kg) of foramen ovale decreased significantly. The median weight-indexed foramen ovale blood flow was 320.82 ml/min/kg (mean 319.1 ml/min/kg; SD 106.33 ml/min/kg).

Conclusions

The reference range for fetal foramen ovale blood flow was determined from 20 to 40 weeks of gestation. The present data show that the volume of foramen ovale blood flow might have a limited capacity to increase during the last trimester.
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
FO
Foramen ovale
LVCO
Left ventricular cardiac output
VTI
Velocity-time integral
QP
Pulmonary blood flow
4DUS
Four-dimensional ultrasound
STIC
Spatiotemporal image correlation
FHR
Fetal heart rate
2DUS
Two-dimensional ultrasound
FO-A
Foramen ovale area
FO-VTI
Foramen ovale flow velocity-time integral
EFW
Estimated fetal weight
ROI
Region of interest
QFO
Absolute blood flow of foramen ovale
iQFO
Weight-indexed foramen ovale blood volume
PC-MRI
Phase-contrast magnetic resonance imaging

Introduction

Shunting through the foramen ovale (FO), which constitutes the majority of left ventricular cardiac output (LVCO), is critical for the delivery of enriched oxygenated blood to the coronary circuit, cerebral circuit, and upper body of the fetus [1]. Premature closure or restriction of the FO leads to reduced or restricted right-to-left atrial shunting. There is substantial evidence that primary closure of the FO results in hypoplasia of left heart structures [2, 3]. Studies of animal [4, 5] and human fetuses [69] have also demonstrated that adaptive changes in FO blood flow volume occur during hypoxia or hypovolemia, suggesting that quantifying FO blood flow and its redistribution plays an important role in assessing fetal adaptation to nutrient and oxygen deficiency. The combination of high-resolution imaging and Doppler ultrasonography has provided a method for calculating the volume of blood flow in the heart and great vessels as the product of the Doppler flow velocity–time integral (VTI) and the cross-sectional area of the flow stream [10]. Because the FO has an irregular shape and a multiphasic blood velocity waveform during the cardiac cycle [11], FO blood flow volume was estimated previously by subtracting pulmonary blood flow (QP) from LVCO [1, 1214]. However, indirect assessment of FO blood flow volume resulted in varied data due to different measurement methods for QP used by different authors. In addition, errors arising from inaccuracies in vessel diameter measurement and Doppler recording are inevitable, especially in small-diameter vessels such as the ductus arteriosus or the left and right pulmonary arteries.
Four-dimensional ultrasound (4DUS) involves the capture of multiple adjacent two-dimensional planes to recreate a four-dimensional volume. Spatiotemporal image correlation (STIC) software captures a fetal heart volume with a single automated sweep of the transducer in a limited time. Spatial and temporal information are combined to display dynamic images that can be extracted from volume datasets. STIC allows heart anatomy visualization through a cine loop sequence in multiplanar and rendering modes. Furthermore, fetal heart rate (FHR) can be detected and synchronized two-dimensional images. STIC can produce more standardized imaging of the fetal heart and reduce operator dependency compared with conventional two-dimensional ultrasound (2DUS) [15]. Visualization of specific heart structures by surface rendering may provide an additional method for assessing cardiac morphology and function and has been used to calculate the area of many fetal cardiac structures, and these measurements present good intra- and inter-observer reproducibility [1619].
Few published data exist on normal FO blood flow volume in relation to fetal gestational age. Thus, the present study was designed to calculate FO blood flow volume directly as the product of foramen ovale area (FO-A) and foramen ovale flow velocity-time integral (FO-VTI). The FO-A was measured by using 4DUS with STIC in rendering mode, and the FO-VTI was obtained by pulsed Doppler. The objective of this study was to define the normal reference range of FO blood flow volume for each gestational age.

Materials and Methods

Study Population.

Healthy women with a singleton fetus at 20–40 weeks of gestation were recruited from the Second Xiangya Hospital, Central South University, and the Third People Hospital of Yongzhou, Hunan, between April 2019 and August 2020 for a cross-sectional study. The inclusion criteria of the study population were as follows: the fetus had no cardiac or extracardiac malformation; each fetus was appropriate for its gestational age in size (between 10 and 90th percentile growth curves for local standards); the amniotic fluid volume was normal; and the mother was in good health and free of diabetes, hypertension, proteinuria, smoking, and drug use. The Research Review Committee of our institution approved the research protocol, and each participant gave written consent to join the study.

Measurements.

The participants were examined using a Voluson E8 device (General Electric, Healthcare, Zipf, Austria) equipped with a 2.0 or 5.0 MHz RAB 4-8L convex probe. All measurements were performed in the state of fetal quietness without fetal respiratory movement. All the recordings were performed by an examiner (W.J.T) with expertise in the 4DUS for obstetrics who received 1 year of specific training in the evaluating and measuring FO-A.
Initially, a 2DUS examination was performed to evaluate fetal biometry, including the biparietal diameter, head circumference, abdominal circumference, and femoral length, and to calculate the estimated fetal weight (EFW, in kilograms). Gestational age was determined by the date of the last menstrual period and confirmed by sonographic biometry in early pregnancy; Image-directed pulsed and colour Doppler equipment was used to obtain the blood velocity waveforms at the level of the FO, and the sample volume was placed on the left atrial side of the four-chamber view (Fig. 1). A 120 Hz high-pass filter was used, and the spatial-peak temporal average power output for colour and pulsed Doppler was kept at < 100 mW/cm2. The sample volume was set at 2-3 mm. If there was an angle of < 15° between the direction of FO blood flow and the Doppler beam, the data were included in the analysis. From Doppler traces, the FHR (in beats per minute) was measured, and the FO-VTI (in millimeters) was determined by measuring the area underneath the Doppler spectrum with a planimeter. Only the right-to-left flow measurements were reported. At least three consecutive cardiac cycles were analysed, and their mean value was used for further analysis. Next, the right and left atrial transverse diameter at end of systole (in millimeters) and the length of atrial septum (in millimeters) were measured in the same four-chamber view.
Subsequently, the fetal FO-A (in millimeters squared) was calculated using the cardio-STIC application. The four-chamber view was used as a reference. The optimal position of the fetal spine for imaging was approximately 3 or 9 o'clock. The sampling frame was adjusted to encompass the entire fetal heart with all its vascular connections at the smallest possible dimension. An aperture angle of 20–40°was used according to gestational age, and the acquisition time was 10–12.5 s. Each mother was asked to hold her breath during acquisition time until a single four-dimensional volume was collected. Later, offline evaluation of the STIC volumes was performed by one of the authors (W.J.T). The four-chamber view was selected as a reference plane, and it was rotated around the Z-axis until the atrial septum and ventricular septum were both in a horizontal position. The rendering button was pressed, and the device was set to surface mode. The reference dot was positioned at the level of the FO and the region of interest (ROI) was adjusted to encompass the entire atrial septum and ventricular septum with the green line of ROI positioned inside the right atrioventricular cavity. The size of the ROI was modified to include half of the left and right atriums. Each section was shown layer by layer from the right atrial side until the FO was clearly visible (Fig. 2a). FO-A was measured at its maximum opening. Next, the rendered image was enlarged and shown on the full screen, the measure button was activated, and the area was manually painted along the margin of FO  (Fig. 2b).

Blood flow calculations.

The absolute blood flow of foramen ovale (QFO, in milliliters per minute) was calculated with the following formula: QFO = FHR × FO-A × FO-VTI.
Next, QFO was normalized to EFW. Weight-indexed foramen ovale blood volume (iQFO, in milliliters per minute per kilogram) was calculated by using the following formula: iQFO = QFO/EFW.
For the assessment of inter-observer reliability, a second examiner (J.W.Y) with the same level of experience in 4DUS in obstetrics performed a second measurement on QFO of 80 randomly chosen fetuses. The examiners were not allowed to share results.

Statistical analysis

For descriptive analysis, the means, medians, standard deviations, and maximum and minimum values of the FO-A and FO blood volume for each gestational age were determined. A curvilinear regression model was fitted to the data versus gestation age, and to interpolate FO-A versus EFW. Bland–Altman plots were used to assess inter-observer variability. Statistical analysis was performed using SPSS 25.0. For all the analyses, statistical significance was defined as P < 0.05.

Results

A total of 550 participants underwent fetal echocardiography, of whom 110 were removed from the data set due to the poor technical quality of their fetal cardiac images, which was caused by maternal conditions including obesity and abdominal scars. The concentration of losers in the third trimester led to a 69% (253/363) of the viewing rate for FO-A in late pregnancy. Adequate datasets for subsequent analysis were ultimately obtained in 440 fetuses (80% rate of acceptance). Each fetus was delivered at term and had an uncomplicated neonatal course. The mean gestational age (with SD) was 29.6 ± 5.7 weeks, the mean maternal age was 27.9 ± 6.0 years (range 17–42), the mean maternal weight was 55.49 ± 4.18 kg, and the mean maternal height was 159.97 ± 4.37 cm.
The mean FO-A was 20.53 ± 2.79mm2 (range 15.25–25.47) in the 20th week of pregnancy and 57.85 ± 7.81mm2 (range 49.12- 76.14) in the 40th week of pregnancy. In STIC rendering mode, the FO presented a round, oval, or irregular shape. The growth of the FO-A increased significantly before 30 weeks, followed by slower growth (Fig. 3a). Figure 3b showed increasing area of the FO versus EFW. The power exponent of the FO-A curve indicated that the increase in FO-A was approximately the square root (0.49) of the fetal body weight.
The median FHR derived from Doppler recording in the FO was 141 bpm (mean 142 bpm; SD 9.11 bpm). Figure 4 demonstrated the trend in FO VTI with advancing gestational age.
General echocardiographic findings, 5th, 50th, and 95th percentiles for the QFO and iQFO at each gestational age evaluated were shown in Table 1.
Table 1
General echocardiographic finds and the 5th, 50th, and 95th percentiles of fetal foramen ovale absolute blood flow (ml/min) and weight-indexed foramen ovale blood volume (ml/min/kg) between the 20th and 40th weeks
 
QFO (ml/min)
iQFO (ml/min/kg)
GA
n
RALD
LALD
ASL
SD
5th
50th
95th
SD
5th
50th
95th
20–20+6
20
5.61 ± 0.29
5.38 ± 0.31
9.94 ± 0.91
36.30
93.31
160.10
212.37
108.32
221.14
453.56
636.34
21–21+6
21
6.11 ± 0.58
5.83 ± 0.58
10.29 ± 0.98
34.84
123.47
191.39
230.49
89.66
252.55
445.09
568.94
22-22+6
21
6.54 ± 0.42
6.19 ± 0.34
10.58 ± 0.69
27.19
155.12
208.82
254.24
57.13
292.09
401.58
470.93
23–23+6
29
7.21 ± 0.59
6.79 ± 0.49
10.85 ± 0.64
37.53
157.62
242.61
300.78
76.82
271.65
396.41
542.66
24–24+6
36
7.48 ± 0.64
7.08 ± 0.65
11.09 ± 0.64
54.35
211.55
260.12
419.32
79.22
321.14
402.91
609.29
25–25+6
20
7.78 ± 0.62
7.28 ± 0.58
11.19 ± 0.67
28.55
264.13
313.88
365.91
54.09
333.91
412.44
516.23
26–26+6
20
8.15 ± 0.65
7.68 ± 0.78
11.29 ± 0.56
25.86
304.34
352.35
399.10
35.24
352.79
417.53
476.38
27–27+6
20
8.75 ± 0.65
8.08 ± 0.65
11.39 ± 0.52
32.68
308.05
371.94
450.99
35.74
279.05
341.14
410.61
28–28+6
23
9.43 ± 0.69
8.68 ± 0.76
11.48 ± 0.56
78.43
305.97
419.07
580.45
74.10
232.39
344.69
519.34
29–29+6
26
9.97 ± 0.81
9.42 ± 0.69
11.58 ± 0.55
60.23
381.06
489.94
591.04
39.67
250.94
342.00
411.94
30–30+6
20
10.42 ± 0.65
9.68 ± 0.62
11.64 ± 0.65
69.93
389.49
491.07
606.57
45.93
244.19
320.79
399.09
31–31+6
20
10.60 ± 0.71
9.78 ± 0.66
11.76 ± 0.61
54.34
405.23
498.51
607.57
45.25
213.89
306.44
390.30
32–32+6
20
10.94 ± 1.09
10.09 ± 0.96
11.83 ± 0.44
56.31
410.44
514.63
612.74
37.99
215.73
270.29
339.48
33–33+6
20
11.61 ± 0.86
10.83 ± 1.00
11.91 ± 0.38
42.26
450.88
517.82
613.29
23.52
219.17
262.57
312.62
34–34+6
20
12.07 ± 0.83
11.33 ± 0.67
12.13 ± 0.39
43.47
458.19
524.65
628.23
20.97
178.39
212.26
261.95
35–35+6
20
12.50 ± 0.82
11.89 ± 0.86
12.17 ± 0.41
57.58
423.19
531.33
636.65
29.49
141.25
205.03
250.59
36–36+6
21
12.83 ± 0.60
12.11 ± 0.46
12.22 ± 0.39
72.63
451.00
560.04
684.66
29.73
147.63
197.39
259.44
37–37+6
21
13.37 ± 0.57
12.61 ± 0.79
12.27 ± 0.32
66.73
452.52
565.39
724.57
22.39
155.80
182.68
229.17
38–38+6
21
13.96 ± 0.64
13.12 ± 0.71
12.29 ± 0.43
76.68
472.33
578.14
743.19
24.71
154.04
184.86
233.39
39–40
21
14.46 ± 0.63
13.66 ± 0.65
12.41 ± 0.54
78.09
491.03
576.07
752.35
25.71
140.99
179.97
237.64
Data expressed as mean ± standard deviation
GA gestational age, n number of pregnant women at each gestational age, SD standard deviation, QFO Foramen ovale absolute blood flow, iQFO Weight-indexed foramen ovale flow, RALD Right atrial transverse diameter at end of systole, LALD Left atrial transverse diameter at end of systole, ASL Length of atrial septum
Fetal QFO increased more than threefold from 20 to 40 weeks of gestation. Figure 5a showed the QFO increased significantly from 20 to 30 weeks of gestation (the mean growth rate was 67%) and then showed a slow upward trend between 30 and 40 weeks of gestation (the mean growth rate was 17%). Figure 5b presented the trend of iQFO with gestational weeks. The negative slope of iQFO was significantly from 20 to 40 weeks of gestation, mean iQFO decreased by 59% (from 450.30 ml/min/kg at 20 weeks of gestation dropped to 184.91 ml/min/kg at term). Median iQFO was 320.82 ml/min/kg (mean 319.1 ml/min/kg; SD 106.33 ml/min/kg).
Through the Bland–Altman plots, good agreement in the measurement for the QFO was observed, with a mean difference of 2.84 (SD ± 24.92 ml/min and 95% CI ± 48.84 ml/min) for inter-observer reliability (Fig. 6).

Discussion

Our study identified gestational age-specific reference ranges for FO blood volume in normal fetuses from 20 to 40 weeks of gestation using STIC in rendering mode combined with pulsed Doppler. The findings of this study suggest that QFO increases with advancing gestational age, showing an exponential increase from 20 to 30 weeks of gestation and a flat growth trend during the last trimester, while iQFO decreases with advanced gestational weeks.
The present study showed that QFO increased more than threefold from 20 to 40 weeks of gestation. QFO showed an exponential increase between 20 and 30 weeks of gestation, the mean growth rate was 67%, whereas the mean growth rate was only 17% from 30 to 40 weeks of gestation. In fetal circulation, enriched oxygenated blood originating from the placenta enters the fetus via the umbilical vein, and part of this constitutes the majority of LVCO through the FO. Therefore, the growth of QFO was associated with an increase in LVCO with advancing gestational age. The emergence of a period of slow growth may be related to the increase in QP in the third trimester. In a study investigating the relationship between QFO and QP in the proportion of LVCO composition in human fetuses during pregnancy, Rasanen et al. [14]found that QP constituted 27% of the LVCO at the beginning of the second half of pregnancy and 50% of the LVCO during the third trimester. The filling of the left atrium is enhanced by an increase in pulmonary venous return, such that right-to-left shunting through the FO may be limited due to the elevation of left atrial pressure. Animal studies have also demonstrated that QFO cannot fully compensate for impaired pulmonary venous return [20, 21], and FO has limited ability to increase its volume blood flow at near-term gestation [22].
There was a declining trend in iQFO with advancing gestational age in our study. Mean iQFO decreased by 59%. The decrease of iQFO with advanced gestational weeks may be related to the decrease of ductus venosus shunt in addition to the increase of QP. Bellotti et al. [23] found the weight-indexed amniotic umbilical flow did not change significantly during gestation, whereas weight-indexed ductus venosus flow decreased significantly, the percentage of umbilical blood flow shunted through the ductus venosus decreased significantly (from 40 to 15%), consequently, the percentage of flow to the liver increased between 20 and 38 weeks gestation. Rudolph et al. [24] found that 55% of the umbilical blood flow was shunted through the ductus venosus in 33 exteriorized human fetuses at 10 to 20 weeks gestation by using isotope-labelled microspheres, and Kiserud et al. [25] found only 20% to 30% shunting through the ductus venosus for the direct supply of the FO during the second half of pregnancy by ultrasonic measurement; correspondingly, an average of 70% to 80% of the oxygenated umbilical venous blood perfused the hepatic tissue. As fetal growth accelerates, an increased proportion of umbilical blood is directed to the liver, and the proportion that is shunted through the ductus venosus decreases, although the blood flow in the umbilical vein grows as pregnancy progresses. The reduction of shunting through the ductus venosus to the inferior vena cava limits, to some extent, the capacity of the FO to increase its volume of blood flow in the third trimester. At the same time, the increasing diversion from cardiac to pulmonary circulation enhances the output of left ventricle as gestation advances, although the reflux of deoxygenated blood from the lungs to the left atrium through the pulmonary veins is marginal in early pregnancy. Phase contrast magnetic resonance imaging (PC-MRI) is a promising new technique for the study of the fetal circulation. It has been shown to be feasible in measurement of the vessel blood flow in the fetal lamb [26] and late-gestation human fetus [2730], and has been used successfully to make initial observations of redistribution of the fetal circulation in human fetuses with congenital heart disease [31, 32]. The mean values of iQFO in the third trimester calculated in the present study are slightly higher than previous PC-MRI measurements in a small series of human fetuses in late pregnancy [27, 28]. This may be because ultrasound technique assumed a constant flow velocity across the vessel lumen, where in fact the flow was likely slower around the vessel periphery than the flow velocity sampled in the middle of the vessel. The Doppler flow parameter used to quantify blood flow in our study is VTI which is the distance that the maximum flow velocity of the stream travels per unit time regardless of the distribution gradient of blood flow velocity in the vessel, this parameter may lead to the overestimation of iQFO to some extent. In addition, intrinsic inaccuracies in ultrasound measurements of flow may also account for discrepancy, such as the measurement of the cross-sectional area and ultrasonic beam angle correction [33]. The mean iQFO (319.1 ± 106.33 ml/min/kg) in the present study is higher than fetal lamb study [26] in which the mean iQFO was 164 ± 20 ml/min/kg. The possible reason is the different proportion of brain mass in animal and human fetuses in addition to the above factors.
Analysing the growth pattern of FO is helpful to understand the variation trend of QFO. In the present study, the FO-A was based on direct measurements in STIC rendering mode. The data showed linear increases with advancing gestation, but slow growth was seen after 30 weeks of gestation. This growth pattern is determined by changes in blood flow through the FO during different gestations, the FO-A increases proportionally to the absolute blood flow to the FO. The data for the FO-A were slightly higher than those in a previously published report [34], in which the horizontal area between the FO valve and atrial septum, as calculated by 2DUS, grew from 15 to 50 mm2 between 18 and 42 weeks of gestation. However, Patten et al. found that the area of the orifice in the atrial septum was larger than the horizontal area between the FO valve and atrial septum in fetuses and new-borns [35], which corresponds closely to our results. The difference in measurement methods may be a factor contributing to the discrepancy. The sagittal view of the FO in the atrial septum not routinely feasible with 2DUS can be generated by STIC. It is possible to directly observe and measure the size of FO by using STIC. Yagel et al. [36] have also suggested that the rendering mode enables superior evaluation of FO in the interatrial septum. Furthermore, STIC offers the possibility of offline analysis without the need for the pregnant woman to be present [37, 38]. In our study, a section including all four heart chambers was easily obtained as the initial scanning surface. As long as the professional has been appropriately trained to sample cardiac volumes, these volumes can be obtained without the need for a specialist, which does not become essential until later, to identify possible abnormalities of heart morphology [38]. An interesting observation was made when we compared FO-A with EFW, FO-A increases approximately as the square root (0.49) of the EFW. Our finding clearly demonstrates that the increase in FO-A is proportional to body size.
The Doppler methods had good accuracy in evaluating blood flow when suitably designed equipment was used in appropriate situations, with less than 6% systematic errors. However, measurement of cross-sectional area and beam angle correction led to random errors [33]. Fetal FO blood flow has been studied by Doppler ultrasound by some scholars [1, 13, 14], while these studies were mainly to establish the concept of fetal combined cardiac output, the research on FO blood flow was focused on the change trend of its proportion in combined cardiac output with gestational weeks, so that there was no specific value of FO blood flow for clinical reference. Therefore, the results of our study cannot be compared with these studies. Previously, FO blood flow was estimated indirectly by subtracting QP from LVCO. QP was expressed as the difference between the right cardiac output and the ductus arteriosus or the left and right pulmonary arteries. In these methods, the inner diameter and blood flow spectrum of multiple vessels need to be measured, there is no doubt that errors were inevitable. It was reported that errors in diameter measurement constitute the main obstacle to reliable flow measurement in small vessels when ultrasonographic techniques are used [39]. The inherent inaccuracy of these methods limits routine clinical practice. Our study shows that the direct measurement of blood flow in the FO is feasible. In our study, the four-chamber section which is used as the measured section is easily accessible. All the paraments needed to calculate FO blood flow volume can be obtained in a single section. The measurement errors resulting from multiple vessels inner diameters and beam angle adjustment in different sections are likely to be greatly reduced. Furthermore, the error caused by measurement in different periods in which the physiological state of the fetus is different can be reduced as much as possible. The QFO measurements obtained in this study showed good inter-observer reliability. Therefore, we believe that our current results provide an accurate presentation of QFO from 20 to 40 weeks of pregnancy and that the range provides a reasonable reflection of the biological variation. However, there are several limitations to the present work. The major limitation of the current study is its possible selection bias. FO-VTI was measured specifically in fetuses with only right-to-left shunting, contributing to the overestimation of QFO to some extent. The novelty of this approach warrants the reporting of this initial sample, and further studies with larger numbers of subjects will ensure the accuracy and reliability of the current study. Our initial experience suggests that this technique is best suited to fetus in the middle of gestation because adequate image acquisition and display with STIC are limited by early gestational age, fetal positioning, maternal obesity, and previous lower abdominal surgery, especially in the third trimester, when only 69% of data in the current were accepted despite the overall qualification rate of 80%, however, these disadvantages are also inherent to conventional ultrasonography. Fetal movement and sudden changes in FHR during data collection are additional factors affecting the technique, possibly causing serious mismatch of the information demanded for accurate reconstruction of moving cardiac structures.

Conclusions

In summary, this study provides reference data on FO blood volume by means of pulsed Doppler combined with STIC. The findings of this study suggest that QFO increases with advancing gestational age, while iQFO decreases with advanced gestational weeks. The FO might have a limited capacity to increase its volume of blood flow during the last trimester. We believe that establishing the normal reference range of FO blood volume can not only improve the understanding of fetal circulatory physiology but also help to assess the risk level of the fetus at an early stage and facilitate perinatal management.

Acknowledgements

Not applicable.

Declarations

All participants had given informed consent, and the study design was approved by the Medical Ethics Committee of the Second Xiangya Hospital of Central South University.
Not applicable.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Sutton MSJ, Groves A, MacNeill A, Sharland G, Allan L. Assessment of changes in blood flow through the lungs and foramen ovale in the normal human fetus with gestational age: a prospective Doppler echocardiographic study. Br Heart J. 1994;71(3):232–7.PubMedPubMedCentralCrossRef Sutton MSJ, Groves A, MacNeill A, Sharland G, Allan L. Assessment of changes in blood flow through the lungs and foramen ovale in the normal human fetus with gestational age: a prospective Doppler echocardiographic study. Br Heart J. 1994;71(3):232–7.PubMedPubMedCentralCrossRef
2.
Zurück zum Zitat Nowlen TT, Ayres NA, Kearney DL, Nihill MR, Grifka RG. Premature closure of the foramen ovale associated with aortic stenosis, left ventricular dilation with thrombus, and early mortality. Am J Cardiol. 2000;85:1159–61.PubMedCrossRef Nowlen TT, Ayres NA, Kearney DL, Nihill MR, Grifka RG. Premature closure of the foramen ovale associated with aortic stenosis, left ventricular dilation with thrombus, and early mortality. Am J Cardiol. 2000;85:1159–61.PubMedCrossRef
4.
Zurück zum Zitat Itskovitz J, LaGamma EF, Rudolph AM. Effects of cord compression on fetal blood flow distribution and O2 delivery. Am J Physiol. 1987;252(1 Pt 2):H100–9.PubMed Itskovitz J, LaGamma EF, Rudolph AM. Effects of cord compression on fetal blood flow distribution and O2 delivery. Am J Physiol. 1987;252(1 Pt 2):H100–9.PubMed
5.
Zurück zum Zitat Jensen A, Roman C, Rudolph AM. Effects of reducing uterine blood flow on fetal blood flow distribution and oxygen delivery. J Dev Physiol. 1991;15(6):309–23.PubMed Jensen A, Roman C, Rudolph AM. Effects of reducing uterine blood flow on fetal blood flow distribution and oxygen delivery. J Dev Physiol. 1991;15(6):309–23.PubMed
6.
Zurück zum Zitat Maršál K. Physiological adaptation of the growth-restricted fetus. Best Pract Res Clin Obstet Gynaecol. 2018;49:37–52.PubMedCrossRef Maršál K. Physiological adaptation of the growth-restricted fetus. Best Pract Res Clin Obstet Gynaecol. 2018;49:37–52.PubMedCrossRef
7.
Zurück zum Zitat Rizzo G, Arduini D. Fetal cardiac function in intrauterine growth retardation. Am J Obstet Gynecol. 1991;165(4):876–82.PubMedCrossRef Rizzo G, Arduini D. Fetal cardiac function in intrauterine growth retardation. Am J Obstet Gynecol. 1991;165(4):876–82.PubMedCrossRef
8.
Zurück zum Zitat Mäkikallio K, Jouppila P, Räsänen J. Retrograde aortic isthmus net blood flow and human fetal cardiac function in placental insufficiency. Ultrasound Obstet Gynecol. 2003;22(4):351–7.PubMedCrossRef Mäkikallio K, Jouppila P, Räsänen J. Retrograde aortic isthmus net blood flow and human fetal cardiac function in placental insufficiency. Ultrasound Obstet Gynecol. 2003;22(4):351–7.PubMedCrossRef
9.
Zurück zum Zitat Rudolph AM. Aortopulmonary transposition in the fetus: speculation on pathophysiology and therapy. Pediatr Res. 2007;61(3):375–80.PubMedCrossRef Rudolph AM. Aortopulmonary transposition in the fetus: speculation on pathophysiology and therapy. Pediatr Res. 2007;61(3):375–80.PubMedCrossRef
10.
Zurück zum Zitat Stewart WJ, Jiang L, Mich R, Pandian N, Guerrero JL, Weyman AE. Variable Effects of Changes in Flow Rate Through the Aortic, Pulmonary and Mitral Valves on Valve Area and Flow Velocity: Impact on Quantitative Doppler Flow Calculation. J Am Coll Cardiol. 1985;6:653–62.PubMedCrossRef Stewart WJ, Jiang L, Mich R, Pandian N, Guerrero JL, Weyman AE. Variable Effects of Changes in Flow Rate Through the Aortic, Pulmonary and Mitral Valves on Valve Area and Flow Velocity: Impact on Quantitative Doppler Flow Calculation. J Am Coll Cardiol. 1985;6:653–62.PubMedCrossRef
11.
Zurück zum Zitat Phillipos EZ, Robertson MA, Still KD. The Echocardiographic Assessment of the human Fetal Foramen Ovale. J Am Soc Echocardiogr. 1994;7:257–63.PubMedCrossRef Phillipos EZ, Robertson MA, Still KD. The Echocardiographic Assessment of the human Fetal Foramen Ovale. J Am Soc Echocardiogr. 1994;7:257–63.PubMedCrossRef
12.
Zurück zum Zitat Anderson DF, Bissonnette JM, Faber JJ, Thornburg KL. Central shunt flows and pressures in the mature fetal lamb. Heartand Circulatory Physiology. 1981;241:H60–6.CrossRef Anderson DF, Bissonnette JM, Faber JJ, Thornburg KL. Central shunt flows and pressures in the mature fetal lamb. Heartand Circulatory Physiology. 1981;241:H60–6.CrossRef
13.
Zurück zum Zitat Mielke G, Benda N. Cardiac Output and Central Distribution of Blood Flow in the Human Fetus. Circulation. 2001;103:1662–8.PubMedCrossRef Mielke G, Benda N. Cardiac Output and Central Distribution of Blood Flow in the Human Fetus. Circulation. 2001;103:1662–8.PubMedCrossRef
14.
Zurück zum Zitat Rasanen J, Dennis C, Wood R, Weiner S, Ludomirski A, Huhta JC. Role of the Pulmonary Circulation in the Distribution of Human Fetal Cardiac Output During the Second Half of Pregnancy. Circulation. 1996;94(5):1068–73.PubMedCrossRef Rasanen J, Dennis C, Wood R, Weiner S, Ludomirski A, Huhta JC. Role of the Pulmonary Circulation in the Distribution of Human Fetal Cardiac Output During the Second Half of Pregnancy. Circulation. 1996;94(5):1068–73.PubMedCrossRef
15.
Zurück zum Zitat Gonçalves LuísF, Lee W, Chaiworapongsa T, Espinoza J, Schoen MaryLou, Falkensammer P, et al. Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation. American Journal of Obstetrics and Gynecology. 2003;189(6):1792–802.PubMedCrossRef Gonçalves LuísF, Lee W, Chaiworapongsa T, Espinoza J, Schoen MaryLou, Falkensammer P, et al. Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation. American Journal of Obstetrics and Gynecology. 2003;189(6):1792–802.PubMedCrossRef
16.
Zurück zum Zitat Rolo LC, Nardozza LMM, Júnior EA, Hatanaka AR, Rocha LA, Simioni C, et al. Reference ranges of atrioventricular valve areas by means of four-dimensional ultrasonography using spatiotemporal image correlation in the rendering mode. Prenat Diagn. 2013;33:50–5.PubMedCrossRef Rolo LC, Nardozza LMM, Júnior EA, Hatanaka AR, Rocha LA, Simioni C, et al. Reference ranges of atrioventricular valve areas by means of four-dimensional ultrasonography using spatiotemporal image correlation in the rendering mode. Prenat Diagn. 2013;33:50–5.PubMedCrossRef
17.
Zurück zum Zitat Nardozza LMM, Rolo LC, Júnior EA, Hatanaka AR, Simioni C, Rocha LA, et al. Reference Range for Fetal Interventricular Septum Area by Means of Four-Dimensional Ultrasonography Using Spatiotemporal Image Correlation. Fetal Diagn Ther. 2013;33:110–5.PubMedCrossRef Nardozza LMM, Rolo LC, Júnior EA, Hatanaka AR, Simioni C, Rocha LA, et al. Reference Range for Fetal Interventricular Septum Area by Means of Four-Dimensional Ultrasonography Using Spatiotemporal Image Correlation. Fetal Diagn Ther. 2013;33:110–5.PubMedCrossRef
18.
Zurück zum Zitat Rolo LC, Rizzo G, Pietrolucci ME, Barros FSB, Nardozza LMM, Martins WP, et al. Viewing rate and reference ranges for papillary muscle areas of the fetal heart using four-dimensional ultrasound in the rendering mode. Prenat Diagn. 2014;34(12):1153–60.PubMedCrossRef Rolo LC, Rizzo G, Pietrolucci ME, Barros FSB, Nardozza LMM, Martins WP, et al. Viewing rate and reference ranges for papillary muscle areas of the fetal heart using four-dimensional ultrasound in the rendering mode. Prenat Diagn. 2014;34(12):1153–60.PubMedCrossRef
19.
Zurück zum Zitat Barros FS, Moron AF, Rolo LC, Rocha LA, Martins WP, Tonni G, et al. Fetal myocardial wall area: constructing a reference range by means of spatiotemporal image correlation in the rendering mode. Fetal Diagn Ther. 2015;37(1):44–50.PubMedCrossRef Barros FS, Moron AF, Rolo LC, Rocha LA, Martins WP, Tonni G, et al. Fetal myocardial wall area: constructing a reference range by means of spatiotemporal image correlation in the rendering mode. Fetal Diagn Ther. 2015;37(1):44–50.PubMedCrossRef
20.
Zurück zum Zitat Erkinaro T, Haapsamo M, Kavasmaa T, Makikallio K, Acharya G, Rasanen J. Fetal cardiac function after labetalol or pindolol for maternal hypertension in a sheep model of increased placental vascular resistance. Eur J Obstet Gynecol Reprod Biol. 2013;166(1):18–22.PubMedCrossRef Erkinaro T, Haapsamo M, Kavasmaa T, Makikallio K, Acharya G, Rasanen J. Fetal cardiac function after labetalol or pindolol for maternal hypertension in a sheep model of increased placental vascular resistance. Eur J Obstet Gynecol Reprod Biol. 2013;166(1):18–22.PubMedCrossRef
21.
Zurück zum Zitat Erkinaro T, Makikallio K, Acharya G, Pakkila M, Kavasmaa T, Huhta JC, et al. Divergent effects of ephedrine and phenylephrine on cardiovascular hemodynamics of near-term fetal sheep exposed to hypoxemia and maternal hypotension. Acta Anaesthesiol Scand. 2007;51(7):922–8.PubMedCrossRef Erkinaro T, Makikallio K, Acharya G, Pakkila M, Kavasmaa T, Huhta JC, et al. Divergent effects of ephedrine and phenylephrine on cardiovascular hemodynamics of near-term fetal sheep exposed to hypoxemia and maternal hypotension. Acta Anaesthesiol Scand. 2007;51(7):922–8.PubMedCrossRef
22.
Zurück zum Zitat Lantto J, Erkinaro T, Haapsamo M, Huhta H, Voipio H-M, Hohimer AR, et al. Foramen ovale blood flow and cardiac function after main pulmonary artery occlusion in fetal sheep. Exp Physiol. 2019;104(2):189–98.PubMedCrossRef Lantto J, Erkinaro T, Haapsamo M, Huhta H, Voipio H-M, Hohimer AR, et al. Foramen ovale blood flow and cardiac function after main pulmonary artery occlusion in fetal sheep. Exp Physiol. 2019;104(2):189–98.PubMedCrossRef
23.
Zurück zum Zitat Bellotti M, Pennati G, Gasperi CD, Battaglia FC, Ferrazzi E. Role of ductus venosus in distribution of umbilical blood flow in human fetuses during second half of pregnancy. Am J Physiol Heart Circ Physiol. 2000;279(3):H1256–63.PubMedCrossRef Bellotti M, Pennati G, Gasperi CD, Battaglia FC, Ferrazzi E. Role of ductus venosus in distribution of umbilical blood flow in human fetuses during second half of pregnancy. Am J Physiol Heart Circ Physiol. 2000;279(3):H1256–63.PubMedCrossRef
24.
Zurück zum Zitat Rudolph AM, Heymann MA, Teramo KAW, Barrett CT, Raiha NCR. Studies on the circulation of the previable human fetus. Obstet Gynecol Surv. 1972;27:607–9.CrossRef Rudolph AM, Heymann MA, Teramo KAW, Barrett CT, Raiha NCR. Studies on the circulation of the previable human fetus. Obstet Gynecol Surv. 1972;27:607–9.CrossRef
25.
Zurück zum Zitat Kiserud T, Rasmussen S, Skulstad S. Blood flow and the degree of shunting through the ductus venosus in the human fetus. Am J Obstet Gynecol. 2000;182:147–53.PubMedCrossRef Kiserud T, Rasmussen S, Skulstad S. Blood flow and the degree of shunting through the ductus venosus in the human fetus. Am J Obstet Gynecol. 2000;182:147–53.PubMedCrossRef
26.
Zurück zum Zitat Duan AQ, Darby JRT, Soo JY, Lock MC, Zhu MY, Flynn LV, et al. Feasibility of phase-contrast cine magnetic resonance imaging for measuring blood flow in the sheep fetus. Am J Physiol Regul Integr Comp Physiol. 2019;317(6):R780–92.PubMedCrossRef Duan AQ, Darby JRT, Soo JY, Lock MC, Zhu MY, Flynn LV, et al. Feasibility of phase-contrast cine magnetic resonance imaging for measuring blood flow in the sheep fetus. Am J Physiol Regul Integr Comp Physiol. 2019;317(6):R780–92.PubMedCrossRef
27.
Zurück zum Zitat Seed M, Amerom JFPv, Yoo S-J, Nafisi BA, Grosse-Wortmann L, Jaeggi E, et al. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using CMR: a cross-sectional study. J Cardiovasc Magnet Reson. 2012;14:79.CrossRef Seed M, Amerom JFPv, Yoo S-J, Nafisi BA, Grosse-Wortmann L, Jaeggi E, et al. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using CMR: a cross-sectional study. J Cardiovasc Magnet Reson. 2012;14:79.CrossRef
28.
Zurück zum Zitat Prsa M, Sun L, van Amerom J, Yoo SJ, Grosse-Wortmann L, Jaeggi E, et al. Reference ranges of blood flow in the major vessels of the normal human fetal circulation at term by phase-contrast magnetic resonance imaging. Circ Cardiovasc Imaging. 2014;7(4):663–70.PubMedCrossRef Prsa M, Sun L, van Amerom J, Yoo SJ, Grosse-Wortmann L, Jaeggi E, et al. Reference ranges of blood flow in the major vessels of the normal human fetal circulation at term by phase-contrast magnetic resonance imaging. Circ Cardiovasc Imaging. 2014;7(4):663–70.PubMedCrossRef
29.
Zurück zum Zitat Salehi D Sun L Steding-Ehrenborg K Bidhult S Kording F Ruprecht C et al Quantification of blood flow in the fetus with cardiovascular magnetic resonance imaging using Doppler ultrasound gating: validation against metric optimized gating Journal of Cardiovascular Magnetic Resonance 2019 21 1 Salehi D Sun L Steding-Ehrenborg K Bidhult S Kording F Ruprecht C et al Quantification of blood flow in the fetus with cardiovascular magnetic resonance imaging using Doppler ultrasound gating: validation against metric optimized gating Journal of Cardiovascular Magnetic Resonance 2019 21 1
30.
Zurück zum Zitat Krishnamurthy U, Yadav BK, Jella PK, Haacke EM, Hernandez-Andrade E, Mody S, et al. Quantitative Flow Imaging in Human Umbilical Vessels In Utero Using Nongated 2D Phase Contrast MRI. J Magn Reson Imaging. 2018;48(1):283–9.PubMedCrossRef Krishnamurthy U, Yadav BK, Jella PK, Haacke EM, Hernandez-Andrade E, Mody S, et al. Quantitative Flow Imaging in Human Umbilical Vessels In Utero Using Nongated 2D Phase Contrast MRI. J Magn Reson Imaging. 2018;48(1):283–9.PubMedCrossRef
31.
Zurück zum Zitat Al Nafisi B, van Amerom JF, Forsey J, Jaeggi E, Grosse-Wortmann L, Yoo SJ, et al. Fetal circulation in left-sided congenital heart disease measured by cardiovascular magnetic resonance: a case-control study. J Cardiovasc Magnet Reson. 2013;15(1):65.CrossRef Al Nafisi B, van Amerom JF, Forsey J, Jaeggi E, Grosse-Wortmann L, Yoo SJ, et al. Fetal circulation in left-sided congenital heart disease measured by cardiovascular magnetic resonance: a case-control study. J Cardiovasc Magnet Reson. 2013;15(1):65.CrossRef
32.
Zurück zum Zitat Porayette P, van Amerom JF, Yoo SJ, Jaeggi E, Macgowan CK, Seed M. MRI shows limited mixing between systemic and pulmonary circulations in foetal transposition of the great arteries: a potential cause of in utero pulmonary vascular disease. Cardiol Young. 2015;25(4):737–44.PubMedCrossRef Porayette P, van Amerom JF, Yoo SJ, Jaeggi E, Macgowan CK, Seed M. MRI shows limited mixing between systemic and pulmonary circulations in foetal transposition of the great arteries: a potential cause of in utero pulmonary vascular disease. Cardiol Young. 2015;25(4):737–44.PubMedCrossRef
33.
Zurück zum Zitat Gill RW. Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol. 1985;11(4):625–41.PubMedCrossRef Gill RW. Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol. 1985;11(4):625–41.PubMedCrossRef
34.
Zurück zum Zitat Kiserud T, Rasmussen S. Ultrasound a sessment of the fetal foramen ovale. Ultrasound Obstet Gynecol. 2001;17:119–24.PubMedCrossRef Kiserud T, Rasmussen S. Ultrasound a sessment of the fetal foramen ovale. Ultrasound Obstet Gynecol. 2001;17:119–24.PubMedCrossRef
35.
Zurück zum Zitat Patten BM, Sommerfield WA, Paff GH. Functional limitations of the foramen ovale in the human foetal heart. Anat Rec. 1929;44:165–78.CrossRef Patten BM, Sommerfield WA, Paff GH. Functional limitations of the foramen ovale in the human foetal heart. Anat Rec. 1929;44:165–78.CrossRef
36.
Zurück zum Zitat Yagel S, Benachi A, Bonnet D, Dumez Y, Hochner-Celnikier D, Cohen SM, et al. Rendering in fetal cardiac scanning: the intracardiac septa and the coronal atrioventricular valve planes. Ultrasound Obstet Gynecol. 2006;28:266–74.PubMedCrossRef Yagel S, Benachi A, Bonnet D, Dumez Y, Hochner-Celnikier D, Cohen SM, et al. Rendering in fetal cardiac scanning: the intracardiac septa and the coronal atrioventricular valve planes. Ultrasound Obstet Gynecol. 2006;28:266–74.PubMedCrossRef
37.
Zurück zum Zitat Vinals F, Mandujano L, Vargas G, Giuliano A. Prenatal diagnosis of congenital heart disease using four-dimensional spatio-temporal image correlation (STIC) telemedicine via an Internet link: a pilot study. Ultrasound Obstet Gynecol. 2005;25:25–31.PubMedCrossRef Vinals F, Mandujano L, Vargas G, Giuliano A. Prenatal diagnosis of congenital heart disease using four-dimensional spatio-temporal image correlation (STIC) telemedicine via an Internet link: a pilot study. Ultrasound Obstet Gynecol. 2005;25:25–31.PubMedCrossRef
38.
Zurück zum Zitat Paladini D, Sglavo G, Greco E, Nappi C. Cardiac screening by STIC: can sonologists performing the 20-week anomaly scan pick up outflow tract abnormalities by scrolling the A-plane of STIC volumes? Ultrasound Obstet Gynecol. 2008;32(7):865–70.PubMedCrossRef Paladini D, Sglavo G, Greco E, Nappi C. Cardiac screening by STIC: can sonologists performing the 20-week anomaly scan pick up outflow tract abnormalities by scrolling the A-plane of STIC volumes? Ultrasound Obstet Gynecol. 2008;32(7):865–70.PubMedCrossRef
39.
Zurück zum Zitat Gill RW, Trudinger BJ, Garrett WJ, Kossoff G, Warren PS. Fetal umbilical venous flow measured in utero by pulsed Doppler and B-mode ultrasound. Am J Obstet Gynecol. 1981;139:720–5.PubMedCrossRef Gill RW, Trudinger BJ, Garrett WJ, Kossoff G, Warren PS. Fetal umbilical venous flow measured in utero by pulsed Doppler and B-mode ultrasound. Am J Obstet Gynecol. 1981;139:720–5.PubMedCrossRef
Metadaten
Titel
Evaluation of fetal foramen ovale blood flow by pulsed Doppler ultrasonography combined with spatiotemporal image correlation
To define the normal reference range of fetal foramen ovale blood volume for each gestational age: a cross-sectional study
verfasst von
Wenjuan Tang
Yuanchen Luo
Shi Zeng
Jiawei Zhou
Ganqiong Xu
Jianwen Yang
Publikationsdatum
01.12.2021
Verlag
BioMed Central
Erschienen in
Cardiovascular Ultrasound / Ausgabe 1/2021
Elektronische ISSN: 1476-7120
DOI
https://doi.org/10.1186/s12947-021-00247-0

Weitere Artikel der Ausgabe 1/2021

Cardiovascular Ultrasound 1/2021 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.