Background

Poly-methyl methacrylate (PMMA) is a type of polymer mostly used to make denture bases. Self-cured acrylic resin (PMMA) can be used to repair a fractured acrylic denture base; however, even after repair, this area remains vulnerable. Carbon nanotubes (CNTs) could be used as a filler for polymer reinforcement. Furthermore, silver nanoparticles are efficient agents for the prevention of dental biofilm and improving their mechanical properties. The doping of CNTs with silver nanoparticles may lead to a synergistic interaction that is predicted to enhance the mechanical characteristics of the fillers.

Objectives

The aim of the study was to assess the influnce of manual incorporation of 0.5% weight percent (%wt.) of silver doped carbon nanotubes (Ag-doped CNTs) into commercial self-cured PMMA on its flexural strength, impact strength, and surface microhardness.

Methods

In this investigation, a total of 60 specimens comprised of acrylic resin were employed. They are divided into two main groups: (a) the control group, which was made by using liquid monomer and commercial self-cured PMMA powder; and (b) the modified group, prepared by hand mixing the purchased silver-doped CNTs powder (0.5% wt.) to self-cured PMMA powder (99.5%wt.), and then the blended powder was incorporated into the liquid monomer. Flexural strength, flexural modulus, impact strength, and surface microhardness were evaluated. Independent sample t-tests were used to statistically analyze the data and compare the mean values of flexural strength, flexural modulus, impact strength, and surface microhardness (p-value ≤ 0.05).

Results

The flexural strength of the modified groups with Ag-doped CNTs (132.4 MPa) was significantly greater than that of the unmodified (control) groups (63.2 MPa). Moreover, the flexural modulus of the modified groups with Ag-doped CNTs (3.067 GPa) was significantly greater than that of the control groups (1.47 GPa). Furthermore, the impact strength of the modified groups with Ag-doped CNTs (11.2 kJ/mm2) was significantly greater than that of the control groups (2.3 kJ/mm2). Furthermore, the microhardness of the modified groups with Ag-doped CNTs (29.7 VHN) was significantly greater than that of the control groups (16.4 VHN), (p-value = 0.0001).

Conclusion

The incorporation of 0.5% wt. silver doped CNTs fillers to the self-cured acrylic resin enhanced its flexural strength, flexural modulus, impact strength, and surface microhardness.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
PMMA
Poly-methyl methacrylate
CNTs
carbon nanotubes
% wt
weight percent
MREC
Medical Research Ethical Committee
NRC
National Research Centre
ISO
International Organization for Standardization
N
Newtons
fs
flexural strength
VHN
Vickers microhardness number.

Background

Most dental applications depend on polymers [14]. One of the most widely used materials in the manufacturing of removable denture bases is acrylic resin [5]. Poly-methyl methacrylate (PMMA) is the main component of heat- or self-cured acrylic resins. Heat-cured acrylic resin is primarily used in the manufacturing of denture bases. Self-cured acrylic resin is used to repair dentures in order to prevent warping and destroying the denture’s broken parts [6, 7].
Fracture of acrylic dentures is an issue commonly encountered by denture wearer patients, and it occurs as a result of insufficiency in material characteristics, technical design, and stresses to which dentures are subjected during service [8]. The most frequent causes of the fracture are improper placement and occlusion of the teeth for the upper denture, as well as accidentally dropping the denture in the case of the lower one and its imperfect fit and stability [9].
High flexural stresses that occur during mastication when using dentures might cause fractures of denture bases inside the mouth [10]. However, fractures outside of the mouth typically occur accidentally, like when a denture is dropped [11]. A Denture rebase or repair of the fractured parts by self-cured acrylic resins is thought to be an excellent strategy, conserving time and expenses. When choosing to build an entirely new denture [12].
All acrylic-based dentures are exposed to internal or external oral stresses [13]. If a denture is suddenly dropped, it could fracture due to its low impact resistance [14]. However, fracture of the denture may occur as a result of increased flexural stresses due to excessive biting force, improper design, an inappropriate occlusal plane, unbalanced occlusion, and a poorly fitted denture [15, 16]. Microhardness is an intrinsic surface property of a material, denoting its resistance to scratching or indentation [17]. Some reports claimed that there is direct correlation between microhardness and wear resistance [18], which is mainly due to incorporation of nano-sized filler particles to the organic matrix, providing a composite with more resistance to wear and scratching [1921]. Despite the desired properties of PMMA, there is an ongoing demand to enhance the mechanical properties of the acrylic denture base [22, 23].
One of the most commonly used materials for denture repair is self-cured acrylic resin. Because self-cured acrylic resins have lower mechanical properties than heat-cured acrylic resins, it is possible to anticipate recurrent fractures. A concern about the improvement of the mechanical properties of the denture base repair materials should be expressed [24]. There have been numerous attempts to incorporate different types of fillers into PMMA-based polymers to reinforce them, such as rubbers, fibers, ceramics, and metals [22, 2529]. Recent studies proved that addition of short E-glass fiber improved the flexural strength of self-cured PMMA materials [30]. Moreover, other study showed that both zirconia and boron nitride fillers could be enhancing the mechanical properties of self-cured PMMA materials [31].
Carbon nanotubes (CNTs) are one of the nanomaterials which promise to accelerate a revolution in the disciplines of dentistry due to their tremendous potential for biological applications and enhanced mechanical and physical properties [3235]. CNTs are mostly used in tissue engineering, either as promoting agents to repair damaged tissues or as scaffolds to create a structural integrity that is favorable for the incorporation of cells [36]. CNTs could be used as a fillers for polymers reinforcement [37]. Multi-walled CNTs could be utilized as superior fillers due to their higher surface area and increased loading capacity [38]. Accordingly, their enhanced mechanical characteristics suggest that they would be employed as an emerging polymer filler [34, 39]. According to studies, functionalization of CNT is the most appropriate to create a carbon-based polymeric material to enhances the mechanical characteristics of the substrates [36].
Silver (Ag) nanoparticles have long been utilized in dentistry due to their strengthening effect, in addition to their antimicrobial activity [40]. Combining CNTs with other nano-metallic particles may be able to provide nanofillers with enhanced properties [41]. The combination of CNTs with Ag nanoparticles may lead to a synergistic interaction to enhance the mechanical properties of the fillers [38]. Thus, the aim of this study was to assess the influence of manual addition of 0.5% weight percent (%wt.) of silver-doped CNT nanoparticles into self-cured PMMA on its flexural strength, impact strength, and surface microhardness. The concentration of 0.5% wt. of Ag-doped CNTs was chosen as it represents the maximum amount by trial that could be added without a visually obvious change in the color of the specimens. The null hypothesis stated that the incorporation of 0.5%wt. silver doped CNTs to chemically-cured PMMA would have no affect the flexural strength, impact strength, or surface microhardness compared to the non-treatment group (control).

Methods

The present experimental study was approved by the Medical Research Ethical Committee (MREC) of the National Research Centre (NRC), Cairo, Egypt (Reference number: 440542023). The sample size was calculated using the G*Power (version 3.1.9.7) sample size calculator based on means and standard deviations [42, 43]. The estimated sample size was 10 per group.
In this study, a commercially available conventional self-cured acrylic resin was utilized (Acrostone Cold Cure Acrylic Resin, Acrostone Co., England). Commercial multi-walled CNT doped with 12%wt. nano-silver powder was also employed (Nanografi Nano Technology, Jena, Germany). The Ag-doped CNT has the following features according to the manufacture’s specifications [44]: average particle length between 15 and 25 nm, average inside diameter of 5 nm, outside diameter less than 50 nm, and an average purity of over 97%wt.
Specimens were divided into two main groups: (a) the control group was prepared by mixing the commercial self-cured PMMA powder to its liquid monomer in a ratio of 3:1 by volume according to the manufacturer’s instructions; (b) the modified group was prepared by manually adding 0.5% of the purchased Ag-doped CNT nanoparticles to self-cured PMMA powder (99.5%) (by weight). Hand-mixing was done by blending the two powders in a rotational motion for 5 minutes using a spatula and then shaking in a closed container for an additional 5 minutes. Then, the blended powder was incorporated into the liquid monomer in a ratio of 3:1 by volume, as previously described.
When the mixed acrylic resin had reached the dough stage, it was packed in certain molds according to each test type. The produced specimens were removed from the molds after 10 minutes to ensure adequate polymerization process as recommended by the manufacture. The specimens were visually examined to ensure that the surface was smooth and flat and showed no faults, voids, or porosity; if not, they were discarded. The specimens were then placed in distilled water at 37 °C for 24 hours before testing [29, 45]. The parameters measured in this study were flexural strength, impact strength, and surface microhardness. For each test, 20 specimens were prepared from each group (control and modified).

Flexural properties testing

A flexural strength test was evaluated using 3-point bending according to ISO 20795-1 [46]. Using a metallic mold, specimens of 64 mm (length) × 10 mm (width) × 3.3 mm (thickness) were prepared [46]. The specimens were examined by a universal testing machine (Model 3345; Instron Industrial Products, Norwood, MA, USA). The load was applied to the center of the specimens, which were kept over a 2-point support span of 50 mm apart with a crosshead speed of 5 mm/min, with a load cell of 500 N. The specimens were loaded till fracture. The load at fracture was represented in Newtons (N). The metallic mold was placed in water at a temperature of 50 °C for 5 minutes to confirm a complete polymerization reaction. The specimens were then kept for 50 ± 2 hours at 37 ± 1 °C in an incubator with distilled water before the flexural strength test.
The flexural strength (FS) was calculated in (MPa) with the following equation [29, 47]: FS = 3PL/2bh2. Where; (P) is the maximum load at fracture (N); (L) is the distance between the supports (mm); (b) is the width (mm); (h) is the height of the specimen (mm).
The flexural modulus (E) was determined in (GPa) using the following formula: E = PL3/4bh3d. Where; (P) is the maximum load at fracture (N); (L) is the distance between the supports (mm); (b) is the width (mm); (h) is the height of the specimen (mm); (d) is the deflection corresponding to the load (mm).

Impact strength test

The impact strength was examined by a Charpy tester (Ceast-Resil impactor, Type 6,967,000, Torino, Italy), following ISO standard 179–1:2010 [48]. At the center of each specimen, a V-shape notch was made. Each specimen was clamped horizontally from both ends, and a swinging pendulum was utilized to hit the specimen in the center to induce fracture. The energy absorption and impact energy (in joules) were assessed using scale readings on fractured specimens. Charpy impact strength was calculated using the following formula [49]: Impact strength (kJ/m2) = E/TW, where: E = the absorbed energy (kJ), W = the specimen width (m), T = the specimen thickness at the notch base (m).

Surface microhardness test

Surface microhardness was investigated by a digital Vickers hardness tester (NEXUS 400TM, INNOVATEST, model no. 4503, The Netherlands). Using a stainless-steel mold, specimens with the dimensions (65 mm × 10 mm × 2.5 mm) were created as shown in Fig. 1 [50, 51]. The indentations were made within 20 seconds of loading 500 g at 20 magnification [50, 51]. The Vickers microhardness number (VHN) value was calculated automatically using the formula: VHN = 1.8544 P/d2, where (p) is the applied force in kilograms and (d) is the mean of the two diagonals gained from the indentation in mm.

Statistical analysis

The statistical analysis was performed using the Statistical Package for the Social Sciences (12.0, SPSS Inc., IBM, USA). According to the results of the normality test conducted with the Shapiro-Wilk and Kolmogorov-Smirnov tests, independent sample t-tests were used to statistically to compare mean values of flexural strength, flexural modulus, impact strength, and microhardness between the two groups (control PMMA and modified PMMA with Ag-doped CNTs). The significance level was set at p-value ≤ 0.05.

Results

The mean and standard deviation values for flexural strength (MPa), flexural modulus (GPa), impact strength (kJ/mm2), and Vickers microhardness number (VHN) for the chemical-cured PMMA (control group) and the modified group with Ag-doped CNTs are represented in Table 1. The flexural strength of the modified groups with Ag-doped CNTs (132.4 MPa) was significantly greater than that of the control groups (63.2 MPa). Moreover, the flexural modulus of the modified groups with Ag-doped CNTs (3.067 GPa) was significantly greater than that of the control groups (1.47 GPa). Furthermore, the impact strength of the modified groups with Ag-doped CNTs (11.2 kJ/mm2) was significantly greater than that of the control groups (2.3 kJ/mm2). Furthermore, the microhardness of the modified groups with Ag-doped CNTs (29.7 VHN) was significantly greater than that of the control groups (16.4 VHN), p-value ≤ 0.05.
Table 1
Results of performed tests for the chemical-cured PMMA, unmodified (control) groups and modified groups with Ag-doped CNTs
Test
Self-cured PMMA (control groups)
Modified groups with Ag-doped CNTs
p-value (Sig.)
Flexural strength (MPa)
63.2 ± 0.3
132.4 ± 0.2
p = 0.0001*
Flexural modulus (GPa)
1.47 ± 0.4
3.067 ± 0.1
p = 0.0001*
Impact strength (kJ/mm2)
2.3 ± 0.2
11.2 ± 0.1
p = 0.0001*
Microhardness (VHN)
16.4 ± 0.6
29.7 ± 0.5
p = 0.0001*
*Corresponds to statistically significant difference (p-value ≤ 0.05)

Discussion

Fracture resistance for acrylic resins is a key concern due to the high costs associated with maintaining acrylic prosthetics [52, 53]. The primary material used to make denture bases is still PMMA acrylic resin [5, 54]. Although the advantages of PMMA self-cured acrylic resin as a denture base repair material are many, fractures are very commonly encountered under flexural and/or impact stresses. Thus, there is a significant need to improve the mechanical characteristics of conventional PMMA-based, self-cured denture bases [14, 30]. Repeated fracture of the repaired denture base often occurs within the repaired, self-cured resin [55].
Researchers have made numerous attempts to improve the mechanical performance of the self-cured PMMA resin [22, 54, 56, 57]. The improvement of the mechanical properties of acrylic resin could be achieved through reinforcement with several fibers and nanoparticles [52, 54].
The international standard ISO for dentistry base polymers states, the acrylic resin should exhibit a minimum standard limit for flexural strength of no less than 60 MPa [46]. The clinical service longevity of the denture is improved with increased flexural strength [58]. On the other hand, the abrupt application of force to dentures might cause them to fracture due to impact stresses. Such fractures are more likely to occur as a result of patients accidentally dropping their dentures while cleaning them [59]. Additionally, the lower values of surface microhardness of chemical-cured acrylic denture bases makes them more prone to being scratched, weakening the denture base, and encouraging the collection of debris [60]. The superior mechanical properties of the CNTs open the door to using them in dental materials to provide a novel functional application [61].
Ag-nanoparticles could be added in combination with CNTs to produce innovative fillers that will be able to improve the mechanical and surface characteristics of conventional PMMA-based self-cured acrylic resin [38, 39, 62]. The percentage of addition of 0.5%wt. of Ag-doped CNTs into commercially chemical-cured PMMA was chosen as previous studies proved that the addition of 0.5%wt. of multi-walled CNTs into PMMA provided minimum polymerization shrinkage, [37] and maximum tensile strength [63].
The purpose of this study was to evaluate and compare the influences of adding 0.5%wt. of Ag-doped CNTs to commercially self-cured PMMA by manual mixing on the flexural strength, impact strength, and surface microhardness to improve some mechanical properties of the denture base.
The null hypothesis was rejected, indicating that the flexural strength, flexural modulus, impact strength, and surface microhardness of the reinforced chemical-cured PMMA acrylic resin were all significantly affected by the addition of 0.5%wt. Ag-doped CNTs to commercial chemical-cured PMMA.
From previous studies, it was concluded that using of fillers with a small average particle size and narrow size range can obtain an improved strengthening effect on the composites [64, 65]. Furthermore, it has been noted that a relatively small weight percentage of nano-sized particle can result in a significantly improved mechanical properties [66].
The findings of this investigation showed that the addition of 0.5%wt. Ag-doped CNTs significantly improved the flexural strength and flexural modulus of chemical-cured acrylic resin, which may be attributed to the restriction of the slippage movement between the polymer segments in relation to each other by the effect of CNTs [6769]. Moreover, the distribution of nano-scaled particles within the conventional polymer exhibits an enormous surface area, which interfaces for stress transfer [5]. The results of the current study agreed with other studies conducted to improve the flexural strength of the self-cured acrylic resin by incorporation of either E-glass fiber or titanium oxide [22, 30].
The increase in impact strength values in the modified groups with Ag-doped CNTs could be obtained due to the effect of the inclusion of strong and stable Ag-doped CNT fillers into polymer. These may be attributed to the arrangement of carbon nanotubes in a hexagonal ring, which reduce the segmental motion [70]. Thus, increasing the impact strength by obstruction of the crack propagation [71]. The current study’s findings were consistent with earlier research aimed at enhancing the self-cured acrylic resin’s impact strength through reinforcing using zirconia and boron nitride nanofillers [31].
The modified groups with Ag-doped CNT nanoparticles showed increased surface microhardness values, which could be explained by the existence of a homogenous distribution of hard nanoparticle fillers of Ag-doped CNTs within the acrylic denture base materials [7276]. These results confirm the results obtained from other study conducted to investigate the surface microhardness the conventional glass ionomer reinforced with Ag-doped CNTs [35].
The results of this study are consistent with prior studies that showed the modification of light-cured PMMA, heat-cured PMMA, and bone cement PMMA by the inclusion of CNTs nanoparticles exhibits an improvement in their mechanical properties compared to conventional ones [5, 37, 63, 69]. Finally, this in vitro study represents a primary phase to investigate the capability of the functionalized Ag-doped CNT nanoparticle to improve the mechanical properties of the conventional PMMA-based self-cured acrylic resin.
The limitations of the current study include the restriction of the mechanical investigation on the flexural strength, impact strength, and surface microhardness only; therefore, it is recommended to investigate other mechanical properties such as compressive strength and fatigue limit. Furthermore, the experimental conditions did not perfectly fit the clinical situations.
It was highly recommended to do further investigation about the bond strength at interface as it represents the most common site for failure. Moreover, it beneficial to perform further studies to perform a morphological and chemical characterization of the modified PMMA groups with Ag-doped CNTs. Further investigations about surface roughness are recommended to assess any possible determinantal effect of the added fillers.

Conclusions

The reinforcement of self-cured PMMA acrylic resin by the addition of 0.5% wt. silver-doped CNT fillers provide promising outcomes on flexural strength, flexural modulus, impact strength, and surface microhardness.

Acknowledgements

Not applicable.

Declarations

This study received ethical approval from the Medical Research Ethical Committee (MREC) of National Research Centre (NRC); Cairo, Egypt (Reference number: 440542023). All methods were performed in accordance with the Declaration of Helsinki.
Not applicable.

Competing interests

The authors declare no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Rokaya D, Srimaneepong V, Sapkota J, Qin J, Siraleartmukul K, Siriwongrungson V. Polymeric materials and films in dentistry: an overview. J Adv Res. 2018;14:25–34.PubMedPubMedCentralCrossRef Rokaya D, Srimaneepong V, Sapkota J, Qin J, Siraleartmukul K, Siriwongrungson V. Polymeric materials and films in dentistry: an overview. J Adv Res. 2018;14:25–34.PubMedPubMedCentralCrossRef
2.
Zurück zum Zitat Abdelraouf RM. Chemical analysis and microstructure examination of extended-pour alginate impression versus conventional one (characterization of dental extended-pour alginate). Int J Polym Mater Polym Biomater. 2018;67:612–8.CrossRef Abdelraouf RM. Chemical analysis and microstructure examination of extended-pour alginate impression versus conventional one (characterization of dental extended-pour alginate). Int J Polym Mater Polym Biomater. 2018;67:612–8.CrossRef
3.
Zurück zum Zitat Abdelraouf RM, Bayoumi RE, Hamdy TM. Effect of powder/water ratio variation on viscosity, tear strength and detail reproduction of dental alginate impression material (in vitro and clinical study). Polymers (Basel). 2021;13:1–11.CrossRef Abdelraouf RM, Bayoumi RE, Hamdy TM. Effect of powder/water ratio variation on viscosity, tear strength and detail reproduction of dental alginate impression material (in vitro and clinical study). Polymers (Basel). 2021;13:1–11.CrossRef
4.
Zurück zum Zitat Abdelraouf RM, Mohammed M, Abdelgawad F. Evaluation of shear-bond-strength of dental self-adhering flowable resin-composite versus total-etch one to enamel and dentin surfaces: an in-vitro study. Open Access Maced J Med Sci. 2019;7:2162–6.PubMedPubMedCentralCrossRef Abdelraouf RM, Mohammed M, Abdelgawad F. Evaluation of shear-bond-strength of dental self-adhering flowable resin-composite versus total-etch one to enamel and dentin surfaces: an in-vitro study. Open Access Maced J Med Sci. 2019;7:2162–6.PubMedPubMedCentralCrossRef
5.
Zurück zum Zitat Somkuwar S, Mishra SK, Agrawal B, Choure R. Comparison of the flexural strength of polymethyl methacrylate resin reinforced with multiwalled carbon nanotubes and processed by conventional water bath technique and microwave polymerization. J Indian Prosthodont Soc. 2017;17:332–9.PubMedPubMedCentralCrossRef Somkuwar S, Mishra SK, Agrawal B, Choure R. Comparison of the flexural strength of polymethyl methacrylate resin reinforced with multiwalled carbon nanotubes and processed by conventional water bath technique and microwave polymerization. J Indian Prosthodont Soc. 2017;17:332–9.PubMedPubMedCentralCrossRef
6.
Zurück zum Zitat Hadi AF, Jassim MM, HA M. Evaluating some mechanical and physical properties of vertex Thermosens denture base material in comparison with heat cure Acrylicdenture Base material. Int J Sci Res. 2017;6:394–7. Hadi AF, Jassim MM, HA M. Evaluating some mechanical and physical properties of vertex Thermosens denture base material in comparison with heat cure Acrylicdenture Base material. Int J Sci Res. 2017;6:394–7.
7.
Zurück zum Zitat Hamouda IM. Retention of Probase hot versus the conventional heat-cured acrylic resin denture bases. Biomed J Sci Tech Res. 2017;1:906–11. Hamouda IM. Retention of Probase hot versus the conventional heat-cured acrylic resin denture bases. Biomed J Sci Tech Res. 2017;1:906–11.
8.
Zurück zum Zitat Choudhary S. Complete denture fracture - A proposed classification system and its incidence in National Capital Region population: A survey. J Indian Prosthodont Soc. 2019;19:307–12.PubMedPubMedCentralCrossRef Choudhary S. Complete denture fracture - A proposed classification system and its incidence in National Capital Region population: A survey. J Indian Prosthodont Soc. 2019;19:307–12.PubMedPubMedCentralCrossRef
9.
Zurück zum Zitat Kumari R, Bala S. Assessment of cases of complete denture fracture. J Pharm Bioallied Sci. 2021;13:1558.CrossRef Kumari R, Bala S. Assessment of cases of complete denture fracture. J Pharm Bioallied Sci. 2021;13:1558.CrossRef
10.
Zurück zum Zitat Minami H, Suzuki S, Kurashige H, Minesaki Y, Tanaka T. Flexural strengths of denture base resin repaired with autopolymerizing resin and reinforcements after thermocycle stressing. J Prosthodont. 2005;14:12–8.PubMedCrossRef Minami H, Suzuki S, Kurashige H, Minesaki Y, Tanaka T. Flexural strengths of denture base resin repaired with autopolymerizing resin and reinforcements after thermocycle stressing. J Prosthodont. 2005;14:12–8.PubMedCrossRef
11.
Zurück zum Zitat Iftikhar J, Saleem MN, Awais F, Naz A, Tuasene A, Saleem Z, et al. Frequency and causes of fracture of acrylic resin complete dentures in edentulous patients. Pakistan J Med Heal Sci. 2022;16:160–2.CrossRef Iftikhar J, Saleem MN, Awais F, Naz A, Tuasene A, Saleem Z, et al. Frequency and causes of fracture of acrylic resin complete dentures in edentulous patients. Pakistan J Med Heal Sci. 2022;16:160–2.CrossRef
12.
Zurück zum Zitat Dar‐Odeh NS, Harrison A, Abu‐Hammad O. An evaluation of self-cured and visible light-cured denture base materials when used as a denture base repair material. J Oral Rehabil. 2008;24:755–60.CrossRef Dar‐Odeh NS, Harrison A, Abu‐Hammad O. An evaluation of self-cured and visible light-cured denture base materials when used as a denture base repair material. J Oral Rehabil. 2008;24:755–60.CrossRef
13.
Zurück zum Zitat Pavith AS, Anjali AK. Reinforcement in Denture Base resins-a review. Ann RSCB. 2021;25:6261–74. Pavith AS, Anjali AK. Reinforcement in Denture Base resins-a review. Ann RSCB. 2021;25:6261–74.
14.
Zurück zum Zitat Faot F, Panza LHV, Garcia RCMR, Cury AADB. Impact and flexural strength, and fracture morphology of acrylic resins with impact modifiers. Open Dent J. 2009;3:137–43.PubMedPubMedCentralCrossRef Faot F, Panza LHV, Garcia RCMR, Cury AADB. Impact and flexural strength, and fracture morphology of acrylic resins with impact modifiers. Open Dent J. 2009;3:137–43.PubMedPubMedCentralCrossRef
16.
Zurück zum Zitat Choksi RH, Mody PV. Flexural properties and impact strength of denture base resins reinforced with micronized glass flakes. J Indian Prosthodont Soc. 2016;16:264–70.PubMedPubMedCentralCrossRef Choksi RH, Mody PV. Flexural properties and impact strength of denture base resins reinforced with micronized glass flakes. J Indian Prosthodont Soc. 2016;16:264–70.PubMedPubMedCentralCrossRef
17.
Zurück zum Zitat Moslehifard E, Ghaffari T, Abolghasemi H, Maleki DS. Comparison of conventional pressure-packed and injection molding processing methods for an acrylic resin denture based on microhardness, surface roughness, and water sorption. Int J Dent. 2022;2022:7069507.PubMedPubMedCentralCrossRef Moslehifard E, Ghaffari T, Abolghasemi H, Maleki DS. Comparison of conventional pressure-packed and injection molding processing methods for an acrylic resin denture based on microhardness, surface roughness, and water sorption. Int J Dent. 2022;2022:7069507.PubMedPubMedCentralCrossRef
18.
Zurück zum Zitat Khanna G, Aparna IN. Comparison of microhardness of three different types of acrylic artificial denture teeth: an in vitro study. J Orofac Res. 2013;3:181–5. Khanna G, Aparna IN. Comparison of microhardness of three different types of acrylic artificial denture teeth: an in vitro study. J Orofac Res. 2013;3:181–5.
19.
Zurück zum Zitat Faria ACL, Benassi UM, Rodrigues RCS, Ribeiro RF, da Gloria Chiarello de Mattos M. Analysis of the relationship between the surface hardness and Wear resistance of indirect composites used as veneer materials. Braz Dent J. 2007;18:60–4.PubMedCrossRef Faria ACL, Benassi UM, Rodrigues RCS, Ribeiro RF, da Gloria Chiarello de Mattos M. Analysis of the relationship between the surface hardness and Wear resistance of indirect composites used as veneer materials. Braz Dent J. 2007;18:60–4.PubMedCrossRef
20.
Zurück zum Zitat Bahrani F, Vojdani M, Safari A, Karampoor G. Comparison of hardness and surface roughness of two denture bases polymerized by different methods. World J Dent. 2012;3:171–5.CrossRef Bahrani F, Vojdani M, Safari A, Karampoor G. Comparison of hardness and surface roughness of two denture bases polymerized by different methods. World J Dent. 2012;3:171–5.CrossRef
21.
Zurück zum Zitat Hamdy TM, El-Korashy SA. Novel bioactive zinc phosphate dental cement with low irritation and enhanced microhardness. e-Journal Surf Sci Nanotechnol. 2018;16:431–5.CrossRef Hamdy TM, El-Korashy SA. Novel bioactive zinc phosphate dental cement with low irritation and enhanced microhardness. e-Journal Surf Sci Nanotechnol. 2018;16:431–5.CrossRef
22.
Zurück zum Zitat Abdelraouf RM, Bayoumi RE, Hamdy TM. Influence of Incorporating 5% Weight Titanium Oxide Nanoparticles on Flexural Strength, Micro-Hardness, Surface Roughness and Water Sorption of Dental Self-Cured Acrylic Resin. Polym. 2022;14:3767.CrossRef Abdelraouf RM, Bayoumi RE, Hamdy TM. Influence of Incorporating 5% Weight Titanium Oxide Nanoparticles on Flexural Strength, Micro-Hardness, Surface Roughness and Water Sorption of Dental Self-Cured Acrylic Resin. Polym. 2022;14:3767.CrossRef
23.
Zurück zum Zitat Naji SA, Behroozibakhsh M, Kashi TSJ, Eslami H, Masaeli R, Mahgoli H, et al. Effects of incorporation of 2.5 and 5 wt% TiO2 nanotubes on fracture toughness, flexural strength, and microhardness of denture base poly methyl methacrylate (PMMA). J Adv Prosthodont. 2018;10:113–21.CrossRef Naji SA, Behroozibakhsh M, Kashi TSJ, Eslami H, Masaeli R, Mahgoli H, et al. Effects of incorporation of 2.5 and 5 wt% TiO2 nanotubes on fracture toughness, flexural strength, and microhardness of denture base poly methyl methacrylate (PMMA). J Adv Prosthodont. 2018;10:113–21.CrossRef
24.
Zurück zum Zitat Ibrahim MH, Alaa M. Effect of aluminum oxide powder reinforcement on degree of conversion, monomer release and flexural strength of heat-cured acrylic resin. Biomed Res Clin Rev. 2020;1:01–5.CrossRef Ibrahim MH, Alaa M. Effect of aluminum oxide powder reinforcement on degree of conversion, monomer release and flexural strength of heat-cured acrylic resin. Biomed Res Clin Rev. 2020;1:01–5.CrossRef
25.
Zurück zum Zitat Zaki DY, Safwat EM, Nagi SM, Salem HN, Hamdy TM, Moharam LM, et al. A novel dental re-mineralizing blend of hydroxyethyl-cellulose and cellulose nanofibers oral film loaded with nepheline apatite glass: preparation, characterization and in vitro evaluation of re-mineralizing effect. Carbohydr Polym Technol Appl. 2021;2:100035. Zaki DY, Safwat EM, Nagi SM, Salem HN, Hamdy TM, Moharam LM, et al. A novel dental re-mineralizing blend of hydroxyethyl-cellulose and cellulose nanofibers oral film loaded with nepheline apatite glass: preparation, characterization and in vitro evaluation of re-mineralizing effect. Carbohydr Polym Technol Appl. 2021;2:100035.
27.
Zurück zum Zitat Abdelnabi A, Hamza MK, El-Borady OM, Hamdy TM. Effect of different formulations and application methods of coral calcium on its Remineralization ability on carious enamel. Open access Maced. J Med Sci. 2020;8:94–9. Abdelnabi A, Hamza MK, El-Borady OM, Hamdy TM. Effect of different formulations and application methods of coral calcium on its Remineralization ability on carious enamel. Open access Maced. J Med Sci. 2020;8:94–9.
28.
Zurück zum Zitat Hamdy TM. Polymerization shrinkage in contemporary resin-based dental composites: A review article. Egypt J Chem. 2021;64:3087–92. Hamdy TM. Polymerization shrinkage in contemporary resin-based dental composites: A review article. Egypt J Chem. 2021;64:3087–92.
29.
Zurück zum Zitat Fonseca RB, Kasuya AVB, Favarão IN, Naves LZ, Hoeppner MG. The influence of polymerization type and reinforcement method on flexural strength of acrylic resin. Sci World J. 2015;2015:919142.CrossRef Fonseca RB, Kasuya AVB, Favarão IN, Naves LZ, Hoeppner MG. The influence of polymerization type and reinforcement method on flexural strength of acrylic resin. Sci World J. 2015;2015:919142.CrossRef
30.
31.
Zurück zum Zitat Alqahtani M. Mechanical properties enhancement of self-cured PMMA reinforced with zirconia and boron nitride nanopowders for high-performance dental materials. J Mech Behav Biomed Mater. 2020;110:103937.PubMedCrossRef Alqahtani M. Mechanical properties enhancement of self-cured PMMA reinforced with zirconia and boron nitride nanopowders for high-performance dental materials. J Mech Behav Biomed Mater. 2020;110:103937.PubMedCrossRef
32.
Zurück zum Zitat Bacakova L, Grausova L, Vandrovcova M, Vacik J, Frazcek A, Blazewicz S, et al. Carbon nanoparticles as substrates for cell adhesion and growth. New Cell Adhesion Research; 2009. p. 119–84. Bacakova L, Grausova L, Vandrovcova M, Vacik J, Frazcek A, Blazewicz S, et al. Carbon nanoparticles as substrates for cell adhesion and growth. New Cell Adhesion Research; 2009. p. 119–84.
33.
Zurück zum Zitat Mohd Hatta MH, Matmin J, Ghazalli NF, Abd Khadir Jalani MA, Hussin F. Recent modifications of carbon nanotubes for biomedical applications. J Teknol. 2023;85:83–100. Mohd Hatta MH, Matmin J, Ghazalli NF, Abd Khadir Jalani MA, Hussin F. Recent modifications of carbon nanotubes for biomedical applications. J Teknol. 2023;85:83–100.
34.
Zurück zum Zitat Kechagioglou P, Andriotis E, Papagerakis P, Papagerakis S. Multiwalled carbon nanotubes for dental applications. Methods Mol Biol. 2019;1922:121–8.PubMedCrossRef Kechagioglou P, Andriotis E, Papagerakis P, Papagerakis S. Multiwalled carbon nanotubes for dental applications. Methods Mol Biol. 2019;1922:121–8.PubMedCrossRef
35.
Zurück zum Zitat Hamdy TM. Evaluation of compressive strength, surface microhardness, solubility and antimicrobial effect of glass ionomer dental cement reinforced with silver doped carbon nanotube fillers. BMC Oral Health. 2023;23:1–9.CrossRef Hamdy TM. Evaluation of compressive strength, surface microhardness, solubility and antimicrobial effect of glass ionomer dental cement reinforced with silver doped carbon nanotube fillers. BMC Oral Health. 2023;23:1–9.CrossRef
36.
Zurück zum Zitat Lekshmi G, Sana SS, Nguyen V-H, Nguyen THC, Nguyen CC, Van LQ, et al. Recent Progress in carbon nanotube polymer composites in tissue engineering and regeneration. Int J Mol Sci. 2020;21:6440.PubMedPubMedCentralCrossRef Lekshmi G, Sana SS, Nguyen V-H, Nguyen THC, Nguyen CC, Van LQ, et al. Recent Progress in carbon nanotube polymer composites in tissue engineering and regeneration. Int J Mol Sci. 2020;21:6440.PubMedPubMedCentralCrossRef
37.
Zurück zum Zitat Turagam N, Prasad MD. Effect of Micro-additions of carbon nanotubes to Polymethylmethacrylate on reduction in polymerization shrinkage. J Prosthodont. 2013;22:105–11.PubMedCrossRef Turagam N, Prasad MD. Effect of Micro-additions of carbon nanotubes to Polymethylmethacrylate on reduction in polymerization shrinkage. J Prosthodont. 2013;22:105–11.PubMedCrossRef
38.
Zurück zum Zitat Hoyos-Palacio LM, Cuesta Castro DP, Ortiz-Trujillo IC, Botero Palacio LE, Galeano Upegui BJ, Escobar Mora NJ, et al. Compounds of carbon nanotubes decorated with silver nanoparticles via in-situ by chemical vapor deposition (CVD). J Mater Res Technol. 2019;8:5893–8.CrossRef Hoyos-Palacio LM, Cuesta Castro DP, Ortiz-Trujillo IC, Botero Palacio LE, Galeano Upegui BJ, Escobar Mora NJ, et al. Compounds of carbon nanotubes decorated with silver nanoparticles via in-situ by chemical vapor deposition (CVD). J Mater Res Technol. 2019;8:5893–8.CrossRef
39.
Zurück zum Zitat Castro-Rojas MA, Vega-Cantu YI, Cordell GA, Rodriguez-Garcia A. Dental applications of carbon nanotubes. Molecules. 2021;26:1–14.CrossRef Castro-Rojas MA, Vega-Cantu YI, Cordell GA, Rodriguez-Garcia A. Dental applications of carbon nanotubes. Molecules. 2021;26:1–14.CrossRef
40.
Zurück zum Zitat Ghosh M, Shetty S. Effect of addition of graphene and carbon nanotubes on flexural strength of Polymethylmethacrylate- A comparative in-vitro study. J Evol Med Dent Sci. 2020;9:1494–9.CrossRef Ghosh M, Shetty S. Effect of addition of graphene and carbon nanotubes on flexural strength of Polymethylmethacrylate- A comparative in-vitro study. J Evol Med Dent Sci. 2020;9:1494–9.CrossRef
41.
Zurück zum Zitat Liu F, Wang X-d, Du S-Y. Production of gold/silver doped carbon nanocomposites for effective photothermal therapy of colon cancer. Sci Rep. 2020;10:1–9. Liu F, Wang X-d, Du S-Y. Production of gold/silver doped carbon nanocomposites for effective photothermal therapy of colon cancer. Sci Rep. 2020;10:1–9.
42.
Zurück zum Zitat Telles V, Brito RMF, Jurach EM, Nojima LI. Assessment of flexural strength of two self-curing acrylic resins containing pigment. Brazilian J Oral Sci. 2009;8:137–40. Telles V, Brito RMF, Jurach EM, Nojima LI. Assessment of flexural strength of two self-curing acrylic resins containing pigment. Brazilian J Oral Sci. 2009;8:137–40.
43.
Zurück zum Zitat Deb S, Muniswamy L, Thota G, Thota L, Swarnakar A, Deepak PV, et al. Impact of surface treatment with different repair acrylic resin on the flexural strength of Denture Base resin: an in vitro study. J Contemp Dent Pract. 2021;21:1137–40.CrossRef Deb S, Muniswamy L, Thota G, Thota L, Swarnakar A, Deepak PV, et al. Impact of surface treatment with different repair acrylic resin on the flexural strength of Denture Base resin: an in vitro study. J Contemp Dent Pract. 2021;21:1137–40.CrossRef
45.
Zurück zum Zitat Tolga Demirtaş T, Kaynak G, Gümüşderelioğlu M. Bone-like hydroxyapatite precipitated from 10×SBF-like solution by microwave irradiation. Mater Sci Eng C. 2015;49:713–9.CrossRef Tolga Demirtaş T, Kaynak G, Gümüşderelioğlu M. Bone-like hydroxyapatite precipitated from 10×SBF-like solution by microwave irradiation. Mater Sci Eng C. 2015;49:713–9.CrossRef
46.
Zurück zum Zitat ISO 20795-1:2008(E) Dentistry — Base polymers — Part 1: Denture base polymers. 2008. ISO 20795-1:2008(E) Dentistry — Base polymers — Part 1: Denture base polymers. 2008.
47.
Zurück zum Zitat Fonseca RB, Favarão IN, Kasuya AVB, Abrão M, Luz NFM d, Naves LZ. Influence of glass Fiber wt% and Silanization on mechanical flexural strength of reinforced acrylics. J Mater Sci Chem Eng. 2014;2:11–5. Fonseca RB, Favarão IN, Kasuya AVB, Abrão M, Luz NFM d, Naves LZ. Influence of glass Fiber wt% and Silanization on mechanical flexural strength of reinforced acrylics. J Mater Sci Chem Eng. 2014;2:11–5.
48.
Zurück zum Zitat ISO 179-1:2010. International Standard ISO 179-1. 61010–1 © Iec2001. 2003;2003:13. ISO 179-1:2010. International Standard ISO 179-1. 61010–1 © Iec2001. 2003;2003:13.
49.
Zurück zum Zitat Ahmad AS. Denture Cleanser’s effect on impact strength of heat cured acrylic. Iraqi Dent J. 2015;37 Ahmad AS. Denture Cleanser’s effect on impact strength of heat cured acrylic. Iraqi Dent J. 2015;37
50.
Zurück zum Zitat Shah J, Bulbule N, Kulkarni S, Shah R, Kakade D. Comparative evaluation of sorption, solubility and microhardness of heat cure polymethylmethacrylate denture base resin & flexible (thermoplastic polyamide nylon) denture base resin. J Clin Diagn Res. 2014;8:ZF01–4.PubMedPubMedCentral Shah J, Bulbule N, Kulkarni S, Shah R, Kakade D. Comparative evaluation of sorption, solubility and microhardness of heat cure polymethylmethacrylate denture base resin & flexible (thermoplastic polyamide nylon) denture base resin. J Clin Diagn Res. 2014;8:ZF01–4.PubMedPubMedCentral
51.
Zurück zum Zitat Farina AP, Cecchin D, Soares RG, Botelho AL, Takahashi JMFK, Mazzetto MO, et al. Evaluation of Vickers hardness of different types of acrylic denture base resins with and without glass fibre reinforcement. Gerodontology. 2012;29:e155–60.PubMedCrossRef Farina AP, Cecchin D, Soares RG, Botelho AL, Takahashi JMFK, Mazzetto MO, et al. Evaluation of Vickers hardness of different types of acrylic denture base resins with and without glass fibre reinforcement. Gerodontology. 2012;29:e155–60.PubMedCrossRef
52.
Zurück zum Zitat Silva AS, Carvalho A, Barreiros P, de Sá J, Aroso C, Mendes JM. Comparison of fracture resistance in thermal and self-curing acrylic resins—an in vitro study. Polymers (Basel). 2021;13:1234.PubMedCrossRef Silva AS, Carvalho A, Barreiros P, de Sá J, Aroso C, Mendes JM. Comparison of fracture resistance in thermal and self-curing acrylic resins—an in vitro study. Polymers (Basel). 2021;13:1234.PubMedCrossRef
53.
Zurück zum Zitat Yadav NS, Khare S, Mishra SK, Vyas R, Mahajan H, Chitumalla R. In-vitro evaluation of transverse strength of repaired heat cured Denture Base resins without surface treatment and with chemical and mechanical surface treatment. J Int Oral Heal. 2015;7:89–92. Yadav NS, Khare S, Mishra SK, Vyas R, Mahajan H, Chitumalla R. In-vitro evaluation of transverse strength of repaired heat cured Denture Base resins without surface treatment and with chemical and mechanical surface treatment. J Int Oral Heal. 2015;7:89–92.
54.
Zurück zum Zitat Olivieri KAN, Costa UV, Miranda ME, Teixeira ML, Fonseca JC. Analysis of flexural strength of a self cured acrylic resin used for fabricating provisional restorations with three different types of reinforcements. Brazilian Dent Sci. 2013;16:70–6.CrossRef Olivieri KAN, Costa UV, Miranda ME, Teixeira ML, Fonseca JC. Analysis of flexural strength of a self cured acrylic resin used for fabricating provisional restorations with three different types of reinforcements. Brazilian Dent Sci. 2013;16:70–6.CrossRef
55.
Zurück zum Zitat Elonianty C, Agustantina TH, Nirwana I. The effect of addition of Bambusa Arundinacea (Retz.) Willd. Fibers to heat-cured acrylic resin on impact strength. Indones J Dent Med. 2018;1:81.CrossRef Elonianty C, Agustantina TH, Nirwana I. The effect of addition of Bambusa Arundinacea (Retz.) Willd. Fibers to heat-cured acrylic resin on impact strength. Indones J Dent Med. 2018;1:81.CrossRef
56.
Zurück zum Zitat Barzegar A, Ghaffari T, Parizad A. Effect of incorporating aluminum oxide nanoparticles on thermal conduction and flexural strength of acrylic resins. Dent Res J (Isfahan). 2022;19:33.PubMedCrossRef Barzegar A, Ghaffari T, Parizad A. Effect of incorporating aluminum oxide nanoparticles on thermal conduction and flexural strength of acrylic resins. Dent Res J (Isfahan). 2022;19:33.PubMedCrossRef
57.
Zurück zum Zitat Abdulrahim R, Yanikoğlu N. Evaluation of Fracture Resistance for Autopolymerizing Acrylic Resin Materials Reinforced with Glass Fiber Mesh, Metal Mesh and Metal Wire Materials: An in Vitro Study. Open J Stomatol. 2022;12:33–41.CrossRef Abdulrahim R, Yanikoğlu N. Evaluation of Fracture Resistance for Autopolymerizing Acrylic Resin Materials Reinforced with Glass Fiber Mesh, Metal Mesh and Metal Wire Materials: An in Vitro Study. Open J Stomatol. 2022;12:33–41.CrossRef
58.
Zurück zum Zitat Meng TR, Latta MA. Physical properties of four acrylic denture base resisns. J Contemp Dent Pract. 2005;6:93–100.PubMedCrossRef Meng TR, Latta MA. Physical properties of four acrylic denture base resisns. J Contemp Dent Pract. 2005;6:93–100.PubMedCrossRef
59.
Zurück zum Zitat Praveen B, Babaji HV, Prasanna BG, Rajalbandi SK, Shreeharsha TV, Prashant GM. Comparison of impact strength and fracture morphology of different heat cure denture acrylic resins: an in vitro study. J Int oral Heal JIOH. 2014;6:12–6. Praveen B, Babaji HV, Prasanna BG, Rajalbandi SK, Shreeharsha TV, Prashant GM. Comparison of impact strength and fracture morphology of different heat cure denture acrylic resins: an in vitro study. J Int oral Heal JIOH. 2014;6:12–6.
60.
Zurück zum Zitat Ogawa T, Hasegawa A. Effect of curing environment on mechanical properties and polymerizing behaviour of methyl-methacrylate autopolymerizing resin. J Oral Rehabil. 2005;32:221–6.PubMedCrossRef Ogawa T, Hasegawa A. Effect of curing environment on mechanical properties and polymerizing behaviour of methyl-methacrylate autopolymerizing resin. J Oral Rehabil. 2005;32:221–6.PubMedCrossRef
61.
Zurück zum Zitat Mirza EH, Khan AA, Al-Khureif AA, Saadaldin SA, Mohamed BA, Fareedi F, et al. Characterization of osteogenic cells grown over modified grapheneoxide-biostable polymers. Biomed Mater. 2019;14:065004.PubMedCrossRef Mirza EH, Khan AA, Al-Khureif AA, Saadaldin SA, Mohamed BA, Fareedi F, et al. Characterization of osteogenic cells grown over modified grapheneoxide-biostable polymers. Biomed Mater. 2019;14:065004.PubMedCrossRef
62.
Zurück zum Zitat Ahmadpoor F, Zebarjad SM, Janghorban K. Decoration of multi-walled carbon nanotubes with silver nanoparticles and investigation on its colloid stability. Mater Chem Phys. 2013;139:113–7.CrossRef Ahmadpoor F, Zebarjad SM, Janghorban K. Decoration of multi-walled carbon nanotubes with silver nanoparticles and investigation on its colloid stability. Mater Chem Phys. 2013;139:113–7.CrossRef
63.
Zurück zum Zitat Bakhtiari SSE, Bakhsheshi-Rad HR, Karbasi S, Tavakoli M, Razzaghi M, Ismail AF, et al. Polymethyl methacrylate-based bone cements containing carbon nanotubes and graphene oxide: an overview of physical, mechanical, and biological properties. Polymers. 2020;12:1469.CrossRef Bakhtiari SSE, Bakhsheshi-Rad HR, Karbasi S, Tavakoli M, Razzaghi M, Ismail AF, et al. Polymethyl methacrylate-based bone cements containing carbon nanotubes and graphene oxide: an overview of physical, mechanical, and biological properties. Polymers. 2020;12:1469.CrossRef
64.
Zurück zum Zitat Yang Z, Fan J, Liu Y, Nie J, Yang Z, Kang Y. Effect of the particle size and matrix strength on strengthening and damage process of the particle reinforced metal matrix composites. Materials (Basel). 2021;14:675.PubMedCrossRef Yang Z, Fan J, Liu Y, Nie J, Yang Z, Kang Y. Effect of the particle size and matrix strength on strengthening and damage process of the particle reinforced metal matrix composites. Materials (Basel). 2021;14:675.PubMedCrossRef
65.
Zurück zum Zitat Ali A, Rahimian Koloor SS, Alshehri AH, Arockiarajan A. Carbon nanotube characteristics and enhancement effects on the mechanical features of polymer-based materials and structures – A review. J Mater Res Technol. 2023;24:6495–521.CrossRef Ali A, Rahimian Koloor SS, Alshehri AH, Arockiarajan A. Carbon nanotube characteristics and enhancement effects on the mechanical features of polymer-based materials and structures – A review. J Mater Res Technol. 2023;24:6495–521.CrossRef
66.
Zurück zum Zitat Chaharmahali M, Hamzeh Y, Ebrahimi G, Ashori A, Ghasemi I. Effects of nano-graphene on the physico-mechanical properties of bagasse/polypropylene composites. Polym Bull. 2014;71:337–49.CrossRef Chaharmahali M, Hamzeh Y, Ebrahimi G, Ashori A, Ghasemi I. Effects of nano-graphene on the physico-mechanical properties of bagasse/polypropylene composites. Polym Bull. 2014;71:337–49.CrossRef
67.
Zurück zum Zitat MacHado AL, Puckett AD, Breeding LC, Wady AF, Vergani CE. Effect of thermocycling on the flexural and impact strength of urethane-based and high-impact denture base resins. Gerodontology. 2012;29:e318–23.PubMedCrossRef MacHado AL, Puckett AD, Breeding LC, Wady AF, Vergani CE. Effect of thermocycling on the flexural and impact strength of urethane-based and high-impact denture base resins. Gerodontology. 2012;29:e318–23.PubMedCrossRef
68.
Zurück zum Zitat Kerby RE, Knobloch LA, Schricker S, Gregg B. Synthesis and evaluation of modified urethane dimethacrylate resins with reduced water sorption and solubility. Dent Mater. 2009;25:302–13.PubMedCrossRef Kerby RE, Knobloch LA, Schricker S, Gregg B. Synthesis and evaluation of modified urethane dimethacrylate resins with reduced water sorption and solubility. Dent Mater. 2009;25:302–13.PubMedCrossRef
69.
Zurück zum Zitat Bin QS, Al KAA, Ramakrishaniah R. An investigation into the impact and flexural strength of light cure denture resin reinforced with carbon nanotubes. World Appl Sci J. 2012;18:808–12. Bin QS, Al KAA, Ramakrishaniah R. An investigation into the impact and flexural strength of light cure denture resin reinforced with carbon nanotubes. World Appl Sci J. 2012;18:808–12.
70.
Zurück zum Zitat Marrs B, Andrews R, Pienkowski D. Multiwall carbon nanotubes enhance the fatigue performance of physiologically maintained methyl methacrylate-styrene copolymer. Carbon N Y. 2007;45:2098–104.CrossRef Marrs B, Andrews R, Pienkowski D. Multiwall carbon nanotubes enhance the fatigue performance of physiologically maintained methyl methacrylate-styrene copolymer. Carbon N Y. 2007;45:2098–104.CrossRef
71.
Zurück zum Zitat Mahmood WS. The Effect of Incorporating Carbon Nanotubes on Impact, Transverse Strength , Hardness , and Roughness to High Impact Denture Base Material. J Baghdad Coll Dent. 2015;27:96–9.CrossRef Mahmood WS. The Effect of Incorporating Carbon Nanotubes on Impact, Transverse Strength , Hardness , and Roughness to High Impact Denture Base Material. J Baghdad Coll Dent. 2015;27:96–9.CrossRef
72.
Zurück zum Zitat Panáček A, Kolář M, Večeřová R, Prucek R, Soukupová J, Kryštof V, et al. Antifungal activity of silver nanoparticles against Candida spp. Biomaterials. 2009;30:6333–40.PubMedCrossRef Panáček A, Kolář M, Večeřová R, Prucek R, Soukupová J, Kryštof V, et al. Antifungal activity of silver nanoparticles against Candida spp. Biomaterials. 2009;30:6333–40.PubMedCrossRef
73.
Zurück zum Zitat Lara HH, Romero-Urbina DG, Pierce C, Lopez-Ribot JL, Arellano-Jiménez MJ, Jose-Yacaman M. Effect of silver nanoparticles on Candida albicans biofilms: An ultrastructural study. J Nanobiotechnology. 2015;13:91.PubMedPubMedCentralCrossRef Lara HH, Romero-Urbina DG, Pierce C, Lopez-Ribot JL, Arellano-Jiménez MJ, Jose-Yacaman M. Effect of silver nanoparticles on Candida albicans biofilms: An ultrastructural study. J Nanobiotechnology. 2015;13:91.PubMedPubMedCentralCrossRef
74.
Zurück zum Zitat Meneses ML, Recalde M, Martin PL, Pardo AG. Antifungal activity of silver nanoparticles and clotrimazole against Candida spp. Brazilian J Pharm Sci. 2022;58:1–11. Meneses ML, Recalde M, Martin PL, Pardo AG. Antifungal activity of silver nanoparticles and clotrimazole against Candida spp. Brazilian J Pharm Sci. 2022;58:1–11.
75.
Zurück zum Zitat AlJindan R, AlEraky DM. Silver nanoparticles: A promising antifungal agent against the growth and biofilm formation of the emergent Candida auris. J Fungi. 2022;8:744.CrossRef AlJindan R, AlEraky DM. Silver nanoparticles: A promising antifungal agent against the growth and biofilm formation of the emergent Candida auris. J Fungi. 2022;8:744.CrossRef
76.
Zurück zum Zitat Alla RK, Guduri V, Tiruveedula NBP, Rao GN, Swamy KNR, Vyas R. Effect of silver nanoparticles incorporation on microhardness of heat-cure denture base resins. Int J Dent Mater. 2020;2:103–10.CrossRef Alla RK, Guduri V, Tiruveedula NBP, Rao GN, Swamy KNR, Vyas R. Effect of silver nanoparticles incorporation on microhardness of heat-cure denture base resins. Int J Dent Mater. 2020;2:103–10.CrossRef
Metadaten
Titel
Evaluation of flexural strength, impact strength, and surface microhardness of self-cured acrylic resin reinforced with silver-doped carbon nanotubes
verfasst von
Tamer M. Hamdy
Publikationsdatum
01.12.2024
Verlag
BioMed Central
Erschienen in
BMC Oral Health / Ausgabe 1/2024
Elektronische ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-024-03909-3

Weitere Artikel der Ausgabe 1/2024

BMC Oral Health 1/2024 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.