Background
The indoor environment of hospitals, with higher risk of microbial contamination, is complicated and different from other occupational or residential indoor settings. Most of the hospitalized patients spend two-third of their time in wards every day; in particular, bed-ridden patients spend almost all their time in the ward. Therefore, the air quality of hospitals may be an important risk factor affecting the health of patients, and assessment of hospital environment is particularly significant.
Airborne microflora in hospital as a potential cause of hospital infections has been the subject of numerous studies. Some researches have been showed that environmental contamination may promote the infection and transmission of healthcare-associated pathogens, including methicillin-resistant
Staphylococcus aureus (MRSA), vancomycin-resistant
Enterococcus spp. (VRE),
Clostridium difficile,
Acinetobacter spp., and norovirus [
1,
2]. Also, some studies suggested that if the prior room was occupied by several important healthcare-associated pathogens, the risk of acquiring these bacteria by a new admission was significantly increased [
3‐
6]. In addition, bioaerosol infection is common in hospitals and recognized to be the causation of agents and illness such as aspergillosis and tuberculosis, as a result, the levels, sources and characteristics of bioaerosols have been extensively investigated [
7‐
11]. PM2.5 is an air pollutant with a diameter of ≤2.5 μm, which can be easily inhaled and can penetrate deep into the airway [
12]. Many studies have confirmed that inhalation exposure to ambient PM in the environment, especially PM2.5, is related to certain systemic diseases and cancer [
13‐
15]. Long- and short-term exposure to PM2.5 has been consistently associated with a number of outcomes, including mortality, cardiovascular and cerebrovascular events and lung cancer [
16‐
20]. Calderón-Garcidueñas et al. highlighted that air pollution can be considered as a risk factor for both Alzheimer’s disease and Parkinson’s disease [
21]. Currently, although the pathogenicity of PM2.5 in aerosol chemistry and physics has been extensively studied, a little is known about the inhalable biological particles such as bacteria, fungi, viruses, pollen, and cell debris [
22‐
24]. In addition, airborne PM2.5 in indoor environments has been widely investigated because of its ability to cause adverse health effects [
25]. A study conducted in the USA about hospital nurses confirmed that PM2.5 was related to the risk of all-cause mortality [
26]. Hence, monitoring of indoor environmental quality is the first step to reduce the chance of nosocomial infections. The traditionally applied methods, to assess microbial air contamination and cleanliness on surfaces in hospital are based on microbiological cultural technology, including active, passive and surfaces sampling [
27]. In recent decade, adenosine triphosphate (ATP) bioluminescence assay, which was used to assess environmental surface cleanliness has been proposed [
28]. Previous studies have shown that the number of microorganisms that can be cultured only accounts for < 5% of the total microorganisms in air [
29‐
31]. Therefore, relying solely on the method of cultivation may not help in accurate assessment of hospital environment. Hence, comprehensive indicators, including fine particles, total microorganisms (including dead microorganisms), culturable microorganisms, and number of living cells, are needed to analyze the complex hospital wards environment.
Conventional microbiological methods for bacterial identification involve culture, microscopic examination, and biochemical testing. Although these procedures can be accurate and reliable, they are time-consuming and require well-trained technicians to interpret the results [
32]. Currently, whole genome sequencing (WGS), an analytical technology that allows sequencing of the whole genomic content of bacteria, would be the best approach to bacterial identification. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has emerged as a tool for microbial identification and diagnosis owing to its specificity, high speed, and low costs. This technology has been widely used for microbial identification and strain typing, detection of antibiotic resistance, detection of blood and urinary tract pathogens, and detection of water- and food-borne pathogens, etc. [
33].
In the present study, we established a set of assessment methods suitable for evaluating the complex indoor environment of hospital wards by using both cultivation and non-cultivation approaches. Subsequently, MALDI-TOF MS was employed to identify the isolated organisms to assess the microbial ecology of the studied environment.
Methods
Setting and sampling
The hospital selected in this study is a comprehensive teaching hospital with three buildings and 1,788 beds in Northeast China. The wards of two hospital buildings (Nos. 1 and 9 buildings), which have the same central HVAC system and the area of each ward was 30 m2, were selected for the investigation. The two buildings were completed in 2016 and 2000, respectively. To compare the differences between the hospital and natural environment, two student dormitories in a university were selected as control. The indoor environmental indicators were monitored in the general hospital in spring between 1/3/2018 and 15/3/2018. The research was approved by the Ethical Committee of Dalian Medical University, China.
Detection of PM2.5 and PM10
The indoor PM2.5 concentrations were detected using optical particle counter PC-5A (Laser Research Institute, Jiangsu, China), which employs light scattering technology to deliver real-time measurements [
34]. In addition to the seventh floor (Obstetrics Dept.) in No. 1 building, five wards of each department from floor 6 to 17 were selected for PM10 detection. Likewise, in No. 9 building, five wards of each department from floor 1 to 11 were selected for PM10 detection. In No. 1 building, three departments with the highest concentration of PM10, namely, General Surgery Dept. VI Ward, GI Surgery Dept. Ward, and GI Dept. I Ward, and two departments with the lowest concentration of PM10, namely, ENT Dept. Ward and Nephrology Dept. Ward, were selected. In No. 9 building, two departments with the highest concentration of PM10, namely, Respiration Dept. I Ward on floor 11 and Respiration Dept. III Ward on floor 9, and two departments with the lowest PM10 concentration, namely, Neurology Dept. VI Ward on floor 3 and Neurology Dept. VII Ward on floor 2, were chosen. Among these nine selected departments, two wards were chosen for each department (totaling to 18 wards), and their PM2.5 content was ascertained. Two measured factors, namely, the use of a humidifier and presence of houseplants, were invariant and therefore not included in the analysis. The air temperature and relative humidity were measured for the duration of the sampling period. The student dormitories, as control, were simultaneously subjected to PM2.5 and PM10 analysis.
Passive sedimentation and dust sample collection
In the 18 wards of the selected nine departments, the bacterial and fungal cultures were accomplished by traditional passive sedimentation method according to the Hospital Sanitary Disinfection Standard (GB15982–2012). The inner, middle, and outer diagonal lines were set up at three points. The inner and outer points were located at 1 m from the wall and at a height of 0.8 m. Three Columbia blood agar plates (BIOMERIEUX, France) for bacteria and three Sabouraud medium plates (Yancheng biology, China) for fungi were placed at the sampling points in each ward. During sampling, the plates were opened for 5 min.
A modified method based on the standard ASTM (method E1728–03) [
35], combined with the protocol developed by Yamamoto [
36] and Rachel I. Adams [
37], was employed to collect indoor dust. Sterile cotton swabs pre-wetted with 0.15 M NaCl and 0.05% Tween 20 sampling buffer were swabbed for 5–10 s on the four corners of the floor, each with an area of 5 × 5 cm, to collect the dust. Then, the swabs were placed in sampling tubes and stored at − 20 °C until DNA extraction. In general, four swabs were obtained for each ward. During the DNA extraction process, two swabs from the same ward were combined into one DNA extraction reaction mixture to obtain sufficient biomass for analysis.
The head of the swab was cut using sterile scissor (sterilized using 75% alcohol) and placed into a 2-ml DNeasy PowerSoil extraction tube (Hilden, Germany). Then, solution C1 was added to the extraction tube and incubated at 65 °C for 10 min. After incubation, the tube was vortexed with a vortex mixer for 20 min, and the DNA was extracted using DNeasy PowerSoil Kit (Hilden, Germany) according to the manufacturer’s protocol.
The bacterial universal primer p1370/p201 [
38] and fungal universal primer NL1/260R [
39] were used to amplify the fragment of bacterial 16S rDNA subunit and fungal 28S rDNA subunit, respectively. All the primers used were synthesized by Takara (Japan), and their sequence details are listed in Table
1.
Table 1
Sequences of the primers used
Bacteria | Forward primer p1370 | 5′-AGICCCGIGAACGTATTCAC-3′ |
Reverse primer p201 | 5′-GAGGAAGGIGIGGAIGACGT-3′ |
Fungi | Forward primer NL1 | 5′-GCATATCAATAAGCGGAGGAAAAG-3′ |
Reverse primer 260R | 5′-TTAGCTTTAGATGRARTTTACCACC-3′ |
The amplified fragments were run on a Real-Time PCR System (Thermal Cycler Dice Real Time System TP800, Takara, Japan) containing 12.5 μl of SYBR Premix Ex Taq II (Tli RNaseH Plus) (2×) (Takara, Japan), 0.5 μl of each 0.4 μM primer, 2 μl of genomic DNA, and water to a final volume of 25 μl. For bacteria, the thermal cycling conditions consisted of an initial denaturation at 95 °C for 30 s, followed by 40 cycles of denaturation at 95 °C for 5 s, annealing at 55 °C for 15 s, and extension at 72 °C for 10 s. For fungi, the PCR conditions were as follows: 95 °C for 30 s, followed by 40 cycles of denaturation at 95 °C for 10 s, annealing at 60 °C for 35 s, and extension at 72 °C for 20 s. Standard curves for bacteria and fungi were based on extraction of a known quantity of Escherichia coli and Aspergillus oryzae spores, respectively.
ATP bioluminescence assay
For ATP bioluminescence assay, Clean-Trace TM NGI instrument, along with Clean-Trace TM Test Kit (3 M, UK), was used. In the 18 wards of the nine selected departments and two student dormitories, a luciferase-containing sampling swab was swabbed at an area of 10 × 10 cm at the end of each bed, and the swab was inserted into the Clean-Trace tube. Then, the handle was pushed so that the sampling rod was completely inserted into the bottom. After shaking for 5 s, the bioluminescence was measured immediately.
Identification by MALDI-TOF MS
Single colonies freshly grown on agar plates were picked and smeared as a thin film directly onto a MALDI steel target plate. Subsequently, 10 μl of 70% formic acid were added and the microbial film was overlaid with 10 μl of MALDI HCCA matrix (50% acetonitrile, 2.5% trifluoroacetic acid, and 47.5% water), as recommended by the MALDI-TOF MS manufacturer. The sample-matrix mixture was dried at room temperature and analyzed using a MALDI-TOF MS analyzer (Bruker Daltonics, Bremen, Germany). The data were processed using MALDI Biotyper 2.3 software (Bruker Daltronics) and the spectra were compared with reference libraries for bacterial identification. A total of three rounds of MALDI-TOF MS were performed. The unidentified bacteria in the first round were subcultured for 24 h and a second round of MALDI-TOF MS identification was performed. The bacteria that still remained unidentified were subcultured for a further 24 h and a third round of MALDI-TOF MS was performed.
Statistical analysis
The mean values of CFUs, PM2.5 and PM10 contents, CT values, and ATP contents in the 18 wards and two student dormitories were calculated, and correlation analyses were performed to determine the relationships among these index. Wilcoxon sum rank test was used to compare the biomass of bacteria and fungi in the wards, and one-sample t-test was employed to assess the difference between the means of wards and dormitories. The statistical analysis was performed using SPSS 24.0 statistical software, and p < 0.05 was considered significant.
Discussion
Air quality in hospitals is likely to be a significant risk factor for the health of patients who visit hospitals. In this study, we employed four different indicators to assess the hospital environment by using both cultivation and non-cultivation approaches. Examination of the correlation among passive sedimentation method, real-time PCR, and ATP bioluminescence assay in wards and dormitories revealed that the bacterial and fungal CFUs measured by passive sedimentation method were not correlated with the ATP content, whereas the CT values for bacteria determined by real-time PCR were negatively correlated with the ATP content (p < 0.05). In other words, the bacterial content detected by real-time PCR was related to the number of living microorganisms in the wards. Furthermore, the CT values detected by real-time PCR were not correlated with CFUs of bacteria and fungi ascertained by passive sedimentation method, suggesting that the two methods were relatively independent, resulting from the various growth conditions of microorganisms and most of the microorganisms are not culturable, while the real-time PCR method can reflect the content of all microorganisms including cultivable and non-cultivable bacteria. Also, the efficiency of DNA extraction, the presence of PCR inhibitors and other factors have been important considerations for real-time PCR results, thus, microbial culture should be combined with real-time PCR for better evaluation of the environment complex of hospital general wards. In addition, as PM2.5 and PM10 detection, bacterial and fungal counts by real-time PCR, CFUs determination by passive sedimentation method, and ATP bioluminescence assay were not completely correlated with each other, it is necessary to combine various indicators to comprehensively analyze the complicated hospital wards environment.
In the present work, PM2.5 was found to have certain correlation with the bacterial and fungal content determined by real-time PCR, bacterial CFUs measured by passive sedimentation method, and ATP bioluminescence, suggesting that PM2.5 can indirectly reflect bacterial and fungal contamination in hospital wards. These results are consistent with the findings of Chen Cao et al. [
40], who provided sequence-based evidence for the existence of inhalable microbial allergens and pathogen species in an open environment, and revealed that the relative abundance of these pollutants appeared to increase with increasing PM pollution. Bacteria and fungi are biological compositions of PM2.5 and most of the microorganisms in air adhere to particles of different sizes, and the pathogens in PM2.5 are considered to be the cause of various allergic and respiratory diseases. In the present study, the detection of PM2.5 content in the wards not only reflected PM pollution in the hospital environment, but also indirectly revealed the evaluation of microbial contamination in the ward. Therefore, PM2.5 detection is more important for assessing the environmental quality of hospital wards. In this study, we ascertained four comprehensive indicators using cultivation and non-cultivation approaches to assess the complex indoor environment. PM2.5 was also recommended for the evaluation of the hospital environmental quality because it is simple and has correlations with other indicators.
MALDI-TOF MS was used in this study to identify the bacterial composition in complex hospital wards and student dormitories. The dominant genera in the air of hospital wards differed from those in the student dormitories, and all of the identified
Staphylococcus species were coagulase-negative staphylococci (CoNS). CoNS are typical opportunists and major nosocomial pathogens that have a substantial impact on human health. In particular, CoNS infections are associated with the use of implanted foreign bodies and central venous catheters, which are indispensable in modern medicine [
41]. After their insertion, foreign bodies can get colonized by CoNS, resulting in severe burdens of medicine and economy [
42]. In the present study,
S. epidermidis,
S. hominis, S. haemolyticus, and
S. capitis were the major CoNS detected in hospital wards. In particular, the prevalence of
S. haemolyticus was highest (22.7%) in the Respiration Dept. I. It must be noted that
S. haemolyticus, which causes septicemia, peritonitis, otitis, and urinary tract infections, is the second most frequently isolated CoNS in human blood cultures [
43‐
46]. Various studies have also reported high levels of antimicrobial resistance in
S. haemolyticus [
47,
48]; specifically,
S. haemolyticus resistance to methicillin is on the rise, which has become a clinical challenge for clinicians. In the present study, the prevalence of CoNS in hospital wards differed from that in dormitories. The prevalence of
S. capitis was the highest in Neurology Dept. VI Ward, accounting for nearly 31%, whereas
S. hominis was dominant in dormitories. Colonization of different parts of the skin and mucosal membranes of the human body is a key source of endogenous CoNS infections. Therefore, to reduce the incidence of nosocomial infections and transmission of CoNS in hospital, measures including adequate sterilization of environmental surfaces and medical instruments, and sufficient hand hygiene should be adopted.
In this study, some rare genera, including
Kocuria spp., were detected in the hospital
. Kocuria spp. are commensals of humans, animals and the environment which can be found in drinking water, sediments, seeds, and fermented foods [
49]. Although there are currently 18 known species of the genus
Kocuria, only
K. kristinae,
K. varians,
K. marina,
K. rhizophila, and
K. rosea have been recognized to cause opportunistic infections [
50]. A recently identified
K. rosea strain (BS1) has been reported to be capable of producing an exopolysaccharide (called Kocuran), which can inhibit the proliferation of phytohemagglutinin-stimulated human peripheral blood mononuclear cells and suppress complement-mediated hemolysis [
51].
Kocuria spp. are normal flora of human skin and oral cavity, and are usually considered to be laboratory contaminants, in particular, their pathogenic potential is often ignored once isolated in clinical specimens. In addition,
Kocuria spp. are generally misidentified as CoNS in the clinical microbiology laboratories owing to the lack of advanced techniques such as 16S rRNA and MALDI-TOF-MS [
52]. In a recent study containing 12 pediatric patients suffering from debilitating conditions such as acute leukemia and premature birth, seven were confirmed to have
K. kristinae bloodstream infection, thus highlighting the significance of
Kocuria spp. in causing niosocomial infections [
53]. However, another research reported a case of an immunocompetent girl, who suffered from endocarditis/sepsis by
K. rosea, suggesting that immunocompromise is not an essential condition in all the reported cases [
54]. Nevertheless, as diseases caused by
Kocuria spp. are rare, they have not been extensively investigated in the past few years.
In this study, a total of three rounds of MADLI-TOF MS were performed to obviate the human error. The results revealed that 11.1 and 27.3% of the bacterial strains isolated from hospital wards and student dormitories could not be identified, respectively, which is a limitation of this study. Given the complexity of environmental microorganisms, mass spectrometric technique and more reference strains, especially for environmental microorganisms, should be developed. The strains identified in this study may indicate the differences between hospital wards and student dormitories, as well as a possibility of imbalance in microbial diversity. Hence, in future research, technologies that are superior to MALDI-TOF MS, such as whole genome sequencing, can be adopted.