Skip to main content
Erschienen in: Lasers in Medical Science 5/2011

01.09.2011 | Original Article

Evaluation of the effects of CO2 laser on debonding of orthodontics porcelain brackets vs. the conventional method

verfasst von: Azita Tehranchi, Reza Fekrazad, Morvarid Zafar, Behnam Eslami, Katayoun A. M. Kalhori, Norbert Gutknecht

Erschienen in: Lasers in Medical Science | Ausgabe 5/2011

Einloggen, um Zugang zu erhalten

Abstract

Debonding of ceramic brackets due to their high bond strength and low fracture toughness is one of the clinician’s complications. The purpose of this study is to evaluate the effect of a laser on shear bond strength, site of debonding, and ARI index during debonding of ceramic brackets and then compare it to the conventional method used for this procedure. Thirty polycrystalline alumina (G & H Series, Germany) brackets were bonded to 30 intact extracted first and second maxillary premolars and stored in a 1% thymol solution. A chemically cured orthodontic composite resin (No-mix, Unitek, USA) was used for bonding the brackets to the enamel surface on all teeth. All brackets were positioned 4 mm from the incisal edge of the teeth with an orthodontic bracket-positioning device. Then the teeth with bonded brackets were embedded in auto-polymerized polymethylmethacrylate (2.2.3 cm) blocks using a special device to make their slots horizontally parallel. These 30 teeth were then divided into two subgroups: control or no-lased (n = 15) and super pulse CO2 laser (n = 15). To characterize the peak of SBS in two groups, we used an Instron machine while its blade was moving at a constant speed of 1 mm/min. For evaluating the site of debonding and the adhesive remnant index (ARI index), a light microscope and the Photoshop program were used. Means and standard deviations of the SBS in two subgroups shows that in the control group, the teeth have definitely higher values in comparison to the experimental group. The results of the two groups drew no substantial differences with respect to the surface of debonding, which was mostly within the adhesive. However, observing the results of ARI presented a significant distinction between the control and experimental group. This index denoted that the debonding site in the control group was closer to the enamel adhesive interface and, consequently, the rate of enamel damage in this group would be greater. The present study shows that a CO2 laser has the potential to replace the conventional method for debonding ceramic brackets due to less debonding force and more adhesive remnant index on the tooth surface.
Literatur
1.
Zurück zum Zitat Flores DA, Caruso JM, Scott GE, Jeiroudi MT (1988) Fracture toughness and surface cracks. The key to understanding ceramic brackets. Angle Orthod 58:5–8 Flores DA, Caruso JM, Scott GE, Jeiroudi MT (1988) Fracture toughness and surface cracks. The key to understanding ceramic brackets. Angle Orthod 58:5–8
2.
Zurück zum Zitat Kusy RP (1988) Morphology of polycrystalline alumina brackets and its relationship to fracture toughness and strength. Angle Orthod 58:197–203 PubMed Kusy RP (1988) Morphology of polycrystalline alumina brackets and its relationship to fracture toughness and strength. Angle Orthod 58:197–203 PubMed
3.
Zurück zum Zitat Crooks M, Hood J, Harkness M (1997) Thermal debonding of ceramic brackets: an in vitro study. AJO 111(2):163–172 Crooks M, Hood J, Harkness M (1997) Thermal debonding of ceramic brackets: an in vitro study. AJO 111(2):163–172
4.
Zurück zum Zitat Brouns EM, Schopf PM, Kocjancic B (1993) Electrothermal debonding of ceramic brackets. Eur J Orthod 15(2):115–123PubMed Brouns EM, Schopf PM, Kocjancic B (1993) Electrothermal debonding of ceramic brackets. Eur J Orthod 15(2):115–123PubMed
5.
Zurück zum Zitat Jost–Brinkman PG, Stein H, Miethke RR Histologic investigation of the human pulp after thermodebonding of metal and ceramic brackets Jost–Brinkman PG, Stein H, Miethke RR Histologic investigation of the human pulp after thermodebonding of metal and ceramic brackets
6.
Zurück zum Zitat Ma T, Marangoni RD, Flint W (1997) In vitro comparison of debonding force and intrapulpal temperature changes during ceramic orthodontic bracket removal using a carbon dioxide laser. Am J Orthod Dentofacial Orthop 111:203–210. doi:10.1016/S0889-5406(97)70217-8 Ma T, Marangoni RD, Flint W (1997) In vitro comparison of debonding force and intrapulpal temperature changes during ceramic orthodontic bracket removal using a carbon dioxide laser. Am J Orthod Dentofacial Orthop 111:203–210. doi:10.​1016/​S0889-5406(97)70217-8
7.
Zurück zum Zitat Stroble K, Bahns TL, Willham L, Bishara SE, Stwalley WC (1992) Laser-aided debonding of orthodontic ceramic brackets. Am J Orthod Dentofacial Orthop 101:152–158. doi:10.1016/0889-5406(92)70007-W Stroble K, Bahns TL, Willham L, Bishara SE, Stwalley WC (1992) Laser-aided debonding of orthodontic ceramic brackets. Am J Orthod Dentofacial Orthop 101:152–158. doi:10.​1016/​0889-5406(92)70007-W
8.
Zurück zum Zitat Obata A (1995) Effectiveness of CO2 laser irradiation on ceramic brackets debonding. J Jpn Orthod Soc 54:285–295 Obata A (1995) Effectiveness of CO2 laser irradiation on ceramic brackets debonding. J Jpn Orthod Soc 54:285–295
10.
Zurück zum Zitat Sinha PK, Nanda RS (2001) Fixed edgewise orthodontic appliances and bonding techniques. Textbook of Orthodontics. Samir E Bishara: 1st Ed. W.B.Saunders Co; Chap 14:194 Sinha PK, Nanda RS (2001) Fixed edgewise orthodontic appliances and bonding techniques. Textbook of Orthodontics. Samir E Bishara: 1st Ed. W.B.Saunders Co; Chap 14:194
11.
Zurück zum Zitat Mimura H, Deguchi T, Obata A, Yamagishi T, Ito M (1995) Comparison of different bonding materials for laser debonding. AJO 188(3):207–273 Mimura H, Deguchi T, Obata A, Yamagishi T, Ito M (1995) Comparison of different bonding materials for laser debonding. AJO 188(3):207–273
12.
Zurück zum Zitat Smith SC, Walsh LJ, Taverne AA (1999) Removal of orthodontic bonding resin residues by CO2 laser radiation. J Clin Laser Med Sug 17(1):13–18 Smith SC, Walsh LJ, Taverne AA (1999) Removal of orthodontic bonding resin residues by CO2 laser radiation. J Clin Laser Med Sug 17(1):13–18
13.
Zurück zum Zitat Obata A, Tsumura T, Niwa K, Ashizaway, Deguchit, Ito M (1999) Superpulse CO2 laser for bracket bonding and debonding. Eur J Orthod 21(2):193–198PubMedCrossRef Obata A, Tsumura T, Niwa K, Ashizaway, Deguchit, Ito M (1999) Superpulse CO2 laser for bracket bonding and debonding. Eur J Orthod 21(2):193–198PubMedCrossRef
14.
Zurück zum Zitat Bishara SE, Fehr DE, Jakobsen JR (1993) A comparative study of the debonding strengths of different ceramic brackets enamel conditioners and adhesives. Am J Orthod Dentofacial Orthop 104:170–179. doi:10.1016/S0889-5406(05)81007-8 Bishara SE, Fehr DE, Jakobsen JR (1993) A comparative study of the debonding strengths of different ceramic brackets enamel conditioners and adhesives. Am J Orthod Dentofacial Orthop 104:170–179. doi:10.​1016/​S0889-5406(05)81007-8
15.
Zurück zum Zitat Tocchio RM, Williams PT, Mayer FJ (1993) Standing KG laser debonding of ceramic orthodontic bracket. AJO 103(2):155–162 Tocchio RM, Williams PT, Mayer FJ (1993) Standing KG laser debonding of ceramic orthodontic bracket. AJO 103(2):155–162
16.
Zurück zum Zitat Azzeh E, Feldon PJ (2003) Laser debonding of ceramic brackets. AJO Dentofac Orthop 123(1):79–83CrossRef Azzeh E, Feldon PJ (2003) Laser debonding of ceramic brackets. AJO Dentofac Orthop 123(1):79–83CrossRef
Metadaten
Titel
Evaluation of the effects of CO2 laser on debonding of orthodontics porcelain brackets vs. the conventional method
verfasst von
Azita Tehranchi
Reza Fekrazad
Morvarid Zafar
Behnam Eslami
Katayoun A. M. Kalhori
Norbert Gutknecht
Publikationsdatum
01.09.2011
Verlag
Springer-Verlag
Erschienen in
Lasers in Medical Science / Ausgabe 5/2011
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-010-0820-y

Weitere Artikel der Ausgabe 5/2011