Skip to main content
Erschienen in: Indian Journal of Hematology and Blood Transfusion 1/2017

29.02.2016 | Original Article

Evaluation of the Sensitivity and Specificity of Use of Glucose and pH for Bacterial Screening of Platelet Concentrates Compared to the Bact/Alert

verfasst von: Farhad Razjou, Hossein Timori Naghadeh, Shirin Ferdowsi, Abolfazl Dabirmoghadam

Erschienen in: Indian Journal of Hematology and Blood Transfusion | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Bacterial contamination of blood components is the major infectious risk in transfusion medicine. Since platelets should be stored at room temperature that makes them an excellent growth medium for bacteria; it is mentioned as a major problem in transfusion medicine. Transfusion risk of a bacterial contaminated platelet concentrate is higher than viral pathogen such as HIV, HBV, HCV and HTLV. The objective of this study was to evaluation of the sensitivity and specificity of use of glucose and pH for bacterial screening of platelet concentrates compared to the Bact/Alert. 1332 platelet concentrates were screened by the Bact/Alert system for aerobic and anaerobic bacterial contamination. Bacterial contamination was also evaluated by using urine reagent strips (Multistix10 SG Bayer) and culture methods. Moreover PH screening with a pH meter (Metrohm 744 Swiss) and glucose was also used for detection of bacterial contamination. The rate of bacterial contamination detected by the Bact/Alert system in platelet concentrates was 25 in 1332 (1.9 %). It contained 15 (1.1 %) for aerobic bacteria and 10 (.8 %) for anaerobic bacteria. 226 of 1332 were considered as containing bacteria by using urine reagent strips. Six of the 226 units were also positive by the Bact/Alert system. Three of those units were culture positive for aerobic bacteria and three for anaerobic. The result of platelet concentrates that underwent pH screening by use of pH meter and a pH portion of urine reagent strips was the same. The sensitivity and specificity of considering glucose alone for detection of bacterial contamination were 12 and 98 % respectively. For pH alone, these were 24 and 83 %. For glucose and/or pH, these were 24 and 83 %; and for combination of glucose and pH, these were 12 and 98 %. Our results showed use of glucose/pH strips would improve the safety of blood products and should be encouraged.
Literatur
1.
Zurück zum Zitat Jacobs MR, Palavecino E, Yomtovian R (2001) Don’t bug me: the problem of bacterial contamination of blood components—challenges and solutions. Transfusion 41:1331–1334CrossRefPubMed Jacobs MR, Palavecino E, Yomtovian R (2001) Don’t bug me: the problem of bacterial contamination of blood components—challenges and solutions. Transfusion 41:1331–1334CrossRefPubMed
2.
Zurück zum Zitat Walther-Wenke G (2008) Incidence of bacterial transmission and transfusion reactions by blood components. Clin Chem Lab Med 46:919–925CrossRefPubMed Walther-Wenke G (2008) Incidence of bacterial transmission and transfusion reactions by blood components. Clin Chem Lab Med 46:919–925CrossRefPubMed
3.
Zurück zum Zitat Ribault S, Harper K, Grave L, Lafontaine C, Nannini P, Raimondo A et al (2004) Rapid screening method for detection of bacteria in platelet concentrates. J Clin Microbiol 42:1903–1908CrossRefPubMedPubMedCentral Ribault S, Harper K, Grave L, Lafontaine C, Nannini P, Raimondo A et al (2004) Rapid screening method for detection of bacteria in platelet concentrates. J Clin Microbiol 42:1903–1908CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat McKane AV, Ward N, Senn C, Eubanks J, Wessels L, Bowman R (2009) Analysis of bacterial detection in whole blood-derived platelets by quantitative glucose testing at a University Medical Center. Am J Clin Pathol 131:542–551CrossRefPubMed McKane AV, Ward N, Senn C, Eubanks J, Wessels L, Bowman R (2009) Analysis of bacterial detection in whole blood-derived platelets by quantitative glucose testing at a University Medical Center. Am J Clin Pathol 131:542–551CrossRefPubMed
5.
Zurück zum Zitat Yomtovian R (2004) Bacterial contamination of blood: lessons from the past and road map for the future. Transfusion 44:450–460CrossRefPubMed Yomtovian R (2004) Bacterial contamination of blood: lessons from the past and road map for the future. Transfusion 44:450–460CrossRefPubMed
6.
Zurück zum Zitat Fisk J, Pisciotto P, Snyder E, Perrota P (2007) Platelets and related products. In: Hillyer CD, Silberstein LE, Ness PM, Anderson KC, Roback JD (eds) Blood banking and transfusion medicine basic principle and practice. Churchill Livingstone Elsevier, Philadelphia, pp 308–341 Fisk J, Pisciotto P, Snyder E, Perrota P (2007) Platelets and related products. In: Hillyer CD, Silberstein LE, Ness PM, Anderson KC, Roback JD (eds) Blood banking and transfusion medicine basic principle and practice. Churchill Livingstone Elsevier, Philadelphia, pp 308–341
7.
Zurück zum Zitat McDonald C (2006) Bacterial risk reduction by improved donor arm disinfection, diversion and bacterial screening. Transfus Med 16:381–396CrossRefPubMed McDonald C (2006) Bacterial risk reduction by improved donor arm disinfection, diversion and bacterial screening. Transfus Med 16:381–396CrossRefPubMed
8.
Zurück zum Zitat Werch J, Mhawech P, Stager C, Banez E, Lichtiger B (2002) Detecting bacteria in platelet concentrates by use of reagent strips. Transfusion 42:1027–1031CrossRefPubMed Werch J, Mhawech P, Stager C, Banez E, Lichtiger B (2002) Detecting bacteria in platelet concentrates by use of reagent strips. Transfusion 42:1027–1031CrossRefPubMed
10.
Zurück zum Zitat Satake M, Mitani T, Oikawa S, Nagumo H, Sugiura S, Tateyama H et al (2009) Frequency of bacterial contamination of platelet concentrates before and after introduction of diversion method in Japan. Transfusion 49:2152–2157CrossRefPubMed Satake M, Mitani T, Oikawa S, Nagumo H, Sugiura S, Tateyama H et al (2009) Frequency of bacterial contamination of platelet concentrates before and after introduction of diversion method in Japan. Transfusion 49:2152–2157CrossRefPubMed
11.
Zurück zum Zitat Benjamin R (2008) Bacterial culture of apheresis platelet products and the residual risk of sepsis. ISBT Sci Ser 3:133–138CrossRef Benjamin R (2008) Bacterial culture of apheresis platelet products and the residual risk of sepsis. ISBT Sci Ser 3:133–138CrossRef
12.
Zurück zum Zitat Davenport R, Mintz P (2007) Transfusion medicine. In: McPherson RA, Pincus MR (eds) HenryÕs clinical diagnosis, pp 669–684 Davenport R, Mintz P (2007) Transfusion medicine. In: McPherson RA, Pincus MR (eds) HenryÕs clinical diagnosis, pp 669–684
13.
Zurück zum Zitat Pietersz R, Engelfriet C, Reesink H, Wood E, Winzar S, Keller A et al (2007) Detection of bacterial contamination of platelet concentrates. Vox Sang 93:260–277CrossRefPubMed Pietersz R, Engelfriet C, Reesink H, Wood E, Winzar S, Keller A et al (2007) Detection of bacterial contamination of platelet concentrates. Vox Sang 93:260–277CrossRefPubMed
14.
Zurück zum Zitat Ezuki S, Kawabata K, Kanno T, Ohto H (2007) Culture-based bacterial detection systems for platelets: the effect of time prior to sampling and duration of incubation required for detection with aerobic culture. Transfusion 47:2044–2049CrossRefPubMed Ezuki S, Kawabata K, Kanno T, Ohto H (2007) Culture-based bacterial detection systems for platelets: the effect of time prior to sampling and duration of incubation required for detection with aerobic culture. Transfusion 47:2044–2049CrossRefPubMed
15.
Zurück zum Zitat Yazer MH, Triulzi DJ (2005) Use of a pH meter for bacterial screening of whole blood platelets. Transfusion 45:1133–1137CrossRefPubMed Yazer MH, Triulzi DJ (2005) Use of a pH meter for bacterial screening of whole blood platelets. Transfusion 45:1133–1137CrossRefPubMed
16.
Zurück zum Zitat Mitchell K-MT, Brecher ME (1999) Approaches to the detection of bacterial contamination in cellular blood products. Transfus Med Rev 13:132–144CrossRefPubMed Mitchell K-MT, Brecher ME (1999) Approaches to the detection of bacterial contamination in cellular blood products. Transfus Med Rev 13:132–144CrossRefPubMed
Metadaten
Titel
Evaluation of the Sensitivity and Specificity of Use of Glucose and pH for Bacterial Screening of Platelet Concentrates Compared to the Bact/Alert
verfasst von
Farhad Razjou
Hossein Timori Naghadeh
Shirin Ferdowsi
Abolfazl Dabirmoghadam
Publikationsdatum
29.02.2016
Verlag
Springer India
Erschienen in
Indian Journal of Hematology and Blood Transfusion / Ausgabe 1/2017
Print ISSN: 0971-4502
Elektronische ISSN: 0974-0449
DOI
https://doi.org/10.1007/s12288-016-0660-4

Weitere Artikel der Ausgabe 1/2017

Indian Journal of Hematology and Blood Transfusion 1/2017 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.