Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 5/2017

10.04.2017 | Original Article • HIP - IMAGING

Factors influencing radiation exposure during internal fixation of hip fractures

verfasst von: G. A. Kelly, F. E. Rowan, C. Hurson

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 5/2017

Einloggen, um Zugang zu erhalten

Abstract

The use of fluoroscopy is of great importance for operative fixation of fractures. Previous studies have shown an increased fluoroscopy time for intramedullary nails and with junior surgeons in comparison with more experienced surgeons. We examined the impact of operation length on fluoroscopy dose, cumulative fluoroscopy time between consultant and registrar surgeons and cumulative fluoroscopy time between dynamic hip screw and intramedullary nailing. We performed a retrospective cohort study of all patients admitted to our centre over the period of 1 year. Patients who underwent dynamic hip screw (DHS) or intramedullary (IM) nailing were identified from our in-hospital hip fracture database. Intraoperative fluoroscopy images were then accessed through our hospital’s medical imaging software. A total of 137 patients were identified. Fluoroscopy reports were not available for 49 patients, resulting in a final total of 88 patients. Patients whose operation lasted longer than 1 h received a statistically significant higher dose of radiation (183.83 cGYM2 vs. 368.22 cGYM2; p value 0.0002). Operations performed by a consultant resulted in less cumulative fluoroscopy time in comparison with those performed by a registrar or specialist registrar although this was not statistically significant (00:00:53 vs. 00:00:45; p vaue 0.38). Cumulative fluoroscopy time was less in dynamic hip screw compared to long intramedullary nails (00:00:39 vs. 00:01:29; p value <0.001) and short intramedullary nails (00:00:39 vs. 00:01:52; p value 0.387). Studies, which had a cumulative fluoroscopy time exceeding 50 secs, delivered a higher radiation dose (434.34cGYM2 vs. 150.51cGYM2; p value <0.001). We concluded that there is no significant impact in cumulative fluoroscopy time in operations performed by either a registrar or consultant. Dynamic hip screws have a lower fluoroscopy time in comparison with long intramedullary nails.
Literatur
1.
Zurück zum Zitat Sanders R, Koval KJ, DiPasquale T, Schmelling G, Stenzler S, Ross E (1993) Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg Am 75(3):326–330CrossRefPubMed Sanders R, Koval KJ, DiPasquale T, Schmelling G, Stenzler S, Ross E (1993) Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg Am 75(3):326–330CrossRefPubMed
2.
Zurück zum Zitat Tsalafoutas IA, Tsapaki V, Kaliakmanis A, Pneumaticos S, Tsoronis F, Koulentianos ED, Papachristou G (2008) Estimation of radiation doses to patients and surgeons from various fluoroscopically guided orthopaedic surgeries. Radiat Prot Dosim 128(1):112–119. doi:10.1093/rpd/ncm234 CrossRef Tsalafoutas IA, Tsapaki V, Kaliakmanis A, Pneumaticos S, Tsoronis F, Koulentianos ED, Papachristou G (2008) Estimation of radiation doses to patients and surgeons from various fluoroscopically guided orthopaedic surgeries. Radiat Prot Dosim 128(1):112–119. doi:10.​1093/​rpd/​ncm234 CrossRef
4.
Zurück zum Zitat McCann PD (2012) Beware: orthopedic surgery is hazardous to our health. Am J Orthop (Belle Mead, NJ) 41(3):112 McCann PD (2012) Beware: orthopedic surgery is hazardous to our health. Am J Orthop (Belle Mead, NJ) 41(3):112
5.
Zurück zum Zitat Singer G (2005) Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg 13(1):69–76CrossRefPubMed Singer G (2005) Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg 13(1):69–76CrossRefPubMed
6.
Zurück zum Zitat Brenner DJ, Doll R, Goodhead DT, Hall EJ, Land CE, Little JB, Lubin JH, Preston DL, Preston RJ, Puskin JS, Ron E, Sachs RK, Samet JM, Setlow RB, Zaider M (2003) Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci USA 100(24):13761–13766. doi:10.1073/pnas.2235592100 CrossRefPubMedPubMedCentral Brenner DJ, Doll R, Goodhead DT, Hall EJ, Land CE, Little JB, Lubin JH, Preston DL, Preston RJ, Puskin JS, Ron E, Sachs RK, Samet JM, Setlow RB, Zaider M (2003) Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci USA 100(24):13761–13766. doi:10.​1073/​pnas.​2235592100 CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B (2005) Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Oxford, England) 55(6):498–500CrossRef Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B (2005) Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Oxford, England) 55(6):498–500CrossRef
12.
Zurück zum Zitat Gullberg B, Johnell O, Kanis JA (1997) World-wide projections for hip fracture. Osteoporos Int J Establ Result Coop Between Eur Found Osteoporos Natl Osteoporos Found USA 7(5):407–413CrossRef Gullberg B, Johnell O, Kanis JA (1997) World-wide projections for hip fracture. Osteoporos Int J Establ Result Coop Between Eur Found Osteoporos Natl Osteoporos Found USA 7(5):407–413CrossRef
13.
Zurück zum Zitat Papadimitropoulos EA, Coyte PC, Josse RG, Greenwood CE (1997) Current and projected rates of hip fracture in Canada. CMAJ Can Med Assoc J 157(10):1357–1363 Papadimitropoulos EA, Coyte PC, Josse RG, Greenwood CE (1997) Current and projected rates of hip fracture in Canada. CMAJ Can Med Assoc J 157(10):1357–1363
14.
Zurück zum Zitat Baumgartner R, Libuit K, Ren D, Bakr O, Singh N, Kandemir U, Marmor MT, Morshed S (2016) Reduction of radiation exposure from C-arm fluoroscopy during orthopaedic trauma operations with introduction of real-time dosimetry. J Orthop Trauma 30(2):e53–58. doi:10.1097/bot.0000000000000442 CrossRefPubMed Baumgartner R, Libuit K, Ren D, Bakr O, Singh N, Kandemir U, Marmor MT, Morshed S (2016) Reduction of radiation exposure from C-arm fluoroscopy during orthopaedic trauma operations with introduction of real-time dosimetry. J Orthop Trauma 30(2):e53–58. doi:10.​1097/​bot.​0000000000000442​ CrossRefPubMed
15.
Zurück zum Zitat Bushberg JTSJ, Leidholdt EM et al (1994) The essentials of medical imaging. Williams & Wilkins, Philadelphia, PA Bushberg JTSJ, Leidholdt EM et al (1994) The essentials of medical imaging. Williams & Wilkins, Philadelphia, PA
16.
Zurück zum Zitat Mountford PJ, Temperton DH (1992) Recommendations of the international commission on radiological protection (ICRP) 1990. Eur J Nucl Med 19(2):77–79CrossRefPubMed Mountford PJ, Temperton DH (1992) Recommendations of the international commission on radiological protection (ICRP) 1990. Eur J Nucl Med 19(2):77–79CrossRefPubMed
17.
Zurück zum Zitat Badman BL, Rill L, Butkovich B, Arreola M, Griend RA (2005) Radiation exposure with use of the mini-C-arm for routine orthopaedic imaging procedures. J Bone Joint Surg Am 87(1):13–17. doi:10.2106/jbjs.d.02162 PubMed Badman BL, Rill L, Butkovich B, Arreola M, Griend RA (2005) Radiation exposure with use of the mini-C-arm for routine orthopaedic imaging procedures. J Bone Joint Surg Am 87(1):13–17. doi:10.​2106/​jbjs.​d.​02162 PubMed
19.
Zurück zum Zitat Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: “how far away is far enough?”. J Orthop Trauma 11(6):392–398CrossRefPubMed Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: “how far away is far enough?”. J Orthop Trauma 11(6):392–398CrossRefPubMed
20.
Zurück zum Zitat Theocharopoulos N, Perisinakis K, Damilakis J, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N (2003) Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. J Bone Joint Surg Am 85-a(9):1698–1703CrossRefPubMed Theocharopoulos N, Perisinakis K, Damilakis J, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N (2003) Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. J Bone Joint Surg Am 85-a(9):1698–1703CrossRefPubMed
21.
Zurück zum Zitat Tremains MR, Georgiadis GM, Dennis MJ (2001) Radiation exposure with use of the inverted-c-arm technique in upper-extremity surgery. J Bone Joint Surg Am 83-a(5):674–678CrossRefPubMed Tremains MR, Georgiadis GM, Dennis MJ (2001) Radiation exposure with use of the inverted-c-arm technique in upper-extremity surgery. J Bone Joint Surg Am 83-a(5):674–678CrossRefPubMed
24.
Zurück zum Zitat Alonso-Fernandez P, Romero E, Chung M, Garcia-Salmones M, Cabezas P, Mora J (2016) Delayed surgery in hip fracture patients. Can we afford it? Int J Health Plan Manage. doi:10.1002/hpm.2353 Alonso-Fernandez P, Romero E, Chung M, Garcia-Salmones M, Cabezas P, Mora J (2016) Delayed surgery in hip fracture patients. Can we afford it? Int J Health Plan Manage. doi:10.​1002/​hpm.​2353
Metadaten
Titel
Factors influencing radiation exposure during internal fixation of hip fractures
verfasst von
G. A. Kelly
F. E. Rowan
C. Hurson
Publikationsdatum
10.04.2017
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 5/2017
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-017-1951-7

Weitere Artikel der Ausgabe 5/2017

European Journal of Orthopaedic Surgery & Traumatology 5/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.