Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 4/2019

28.01.2019 | Original Article • HIP - ARTHROPLASTY

Femoral neck preservation with a short hip stem produced with powder manufacturing: mid-term results of a consecutive case series

verfasst von: Marco Schiraldi, Manuel Bondi, Lodovico Renzi Brivio

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

Stress shielding and thigh pain are not uncommon after cementless total hip arthroplasty (THA) using conventional hip stems. It has been postulated that short, neck-preserving stems may overcome these disadvantages of standard stems and, hence, further improve clinical outcome. The purpose of our retrospective study was to assess the mid-term performance of a neck-preserving hip stem for which, as of yet, no clinical results have been published. A population of 146 consecutive patients who received 152 neck-preserving stems over a 1.6-year period was retrospectively reviewed. Harris Hip Score (HHS) and the Western Ontario and McMasters Universities Osteoarthritis Index (WOMAC) were collected, along with radiographic data. One hundred and forty-four THAs implanted in 136 patients were available for analysis. After a mean follow-up of 56 months, mean HHS and WOMAC improved significantly versus preoperative values. Aseptic loosening was not observed. Five-year survival with revision of any component for any reason as the endpoint was 99.3% (95% confidence interval, 95.2–99.9%). Excellent mid-term clinical and radiographic outcomes were observed with the study device. We attribute this to the metaphyseal fit in combination with retention of the femoral neck. However, our findings need to be confirmed by multicentre studies with larger patient samples.
Literatur
1.
Zurück zum Zitat Daigle ME, Weinstein AM, Katz JN, Losina E (2012) The cost-effectiveness of total joint arthroplasty: a systematic review of published literature. Best Pract Res Clin Rheumatol 26(5):649–658CrossRefPubMed Daigle ME, Weinstein AM, Katz JN, Losina E (2012) The cost-effectiveness of total joint arthroplasty: a systematic review of published literature. Best Pract Res Clin Rheumatol 26(5):649–658CrossRefPubMed
2.
Zurück zum Zitat Khanuja HS, Banerjee S, Jain D, Pivec R, Mont MA (2014) Short bone-conserving stems in cementless hip arthroplasty. J Bone Joint Surg Am 96(20):1742–1752CrossRefPubMed Khanuja HS, Banerjee S, Jain D, Pivec R, Mont MA (2014) Short bone-conserving stems in cementless hip arthroplasty. J Bone Joint Surg Am 96(20):1742–1752CrossRefPubMed
3.
Zurück zum Zitat Lavernia C, D’Apuzzo M, Hernandez V, Lee D (2004) Thigh pain in primary total hip arthroplasty: the effects of elastic moduli. J Arthroplasty 19(7 Suppl 2):10–16CrossRefPubMed Lavernia C, D’Apuzzo M, Hernandez V, Lee D (2004) Thigh pain in primary total hip arthroplasty: the effects of elastic moduli. J Arthroplasty 19(7 Suppl 2):10–16CrossRefPubMed
4.
Zurück zum Zitat Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS (1988) The anatomic basis of femoral component design. Clin Orthop Relat Res 235(235):148–165 Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS (1988) The anatomic basis of femoral component design. Clin Orthop Relat Res 235(235):148–165
5.
6.
Zurück zum Zitat Worlicek M, Weber M, Craiovan B, Wörner M, Völlner F, Springorum HR, Grifka J, Renkawitz T (2016) Native femoral anteversion should not be used as reference in cementless total hip arthroplasty with a straight, tapered stem: a retrospective clinical study. BMC Musculoskelet Disord 17:399CrossRefPubMedPubMedCentral Worlicek M, Weber M, Craiovan B, Wörner M, Völlner F, Springorum HR, Grifka J, Renkawitz T (2016) Native femoral anteversion should not be used as reference in cementless total hip arthroplasty with a straight, tapered stem: a retrospective clinical study. BMC Musculoskelet Disord 17:399CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Nunn D, Freeman MA, Tanner KE, Bonfield W (1989) Torsional stability of the femoral component of hip arthroplasty. Response to an anteriorly applied load. J Bone Joint Surg Br 71(3):452–455CrossRef Nunn D, Freeman MA, Tanner KE, Bonfield W (1989) Torsional stability of the femoral component of hip arthroplasty. Response to an anteriorly applied load. J Bone Joint Surg Br 71(3):452–455CrossRef
9.
Zurück zum Zitat Traina F, De Clerico M, Biondi F, Pilla F, Tassinari E, Toni A (2009) Sex differences in hip morphology: is stem modularity effective for total hip replacement? J Bone Joint Surg Am 91(Suppl 6):121–128CrossRefPubMed Traina F, De Clerico M, Biondi F, Pilla F, Tassinari E, Toni A (2009) Sex differences in hip morphology: is stem modularity effective for total hip replacement? J Bone Joint Surg Am 91(Suppl 6):121–128CrossRefPubMed
10.
Zurück zum Zitat Lindahl H (2007) Epidemiology of periprosthetic femur fracture around a total hip arthroplasty. Injury 38(6):651–654CrossRefPubMed Lindahl H (2007) Epidemiology of periprosthetic femur fracture around a total hip arthroplasty. Injury 38(6):651–654CrossRefPubMed
11.
Zurück zum Zitat Budde S, Seehaus F, Schwarze M, Hurschler C, Floerkemeier T, Windhagen H, Noll Y, Ettinger M, Thorey F (2016) Analysis of migration of the Nanos(R) short-stem hip implant within 2 years after surgery. Int Orthop 40(8):1607–1614CrossRefPubMed Budde S, Seehaus F, Schwarze M, Hurschler C, Floerkemeier T, Windhagen H, Noll Y, Ettinger M, Thorey F (2016) Analysis of migration of the Nanos(R) short-stem hip implant within 2 years after surgery. Int Orthop 40(8):1607–1614CrossRefPubMed
12.
Zurück zum Zitat Yan SG, Woiczinski M, Schmidutz TF, Weber P, Paulus AC, Steinbruck A, Jansson V, Schmidutz F (2017) Can the metaphyseal anchored Metha short stem safely be revised with a standard CLS stem? A biomechanical analysis. Int Orthop 41(12):2471–2477CrossRefPubMed Yan SG, Woiczinski M, Schmidutz TF, Weber P, Paulus AC, Steinbruck A, Jansson V, Schmidutz F (2017) Can the metaphyseal anchored Metha short stem safely be revised with a standard CLS stem? A biomechanical analysis. Int Orthop 41(12):2471–2477CrossRefPubMed
13.
Zurück zum Zitat Hochreiter J, Hejkrlik W, Emmanuel K, Hitzl W, Ortmaier R (2017) Blood loss and transfusion rate in short stem hip arthroplasty. A comparative study. Int Orthop 41(7):1347–1353CrossRefPubMed Hochreiter J, Hejkrlik W, Emmanuel K, Hitzl W, Ortmaier R (2017) Blood loss and transfusion rate in short stem hip arthroplasty. A comparative study. Int Orthop 41(7):1347–1353CrossRefPubMed
14.
Zurück zum Zitat Dabirrahmani D, Hogg M, Kohan L, Gillies M (2010) Primary and long-term stability of a short-stem hip implant. Proc Inst Mech Eng H 224(9):1109–1119CrossRefPubMed Dabirrahmani D, Hogg M, Kohan L, Gillies M (2010) Primary and long-term stability of a short-stem hip implant. Proc Inst Mech Eng H 224(9):1109–1119CrossRefPubMed
15.
Zurück zum Zitat Kim YH, Park JW, Kim JS (2013) Is diaphyseal stem fixation necessary for primary total hip arthroplasty in patients with osteoporotic bone (Class C bone)? J Arthroplasty 28(1):139–146.e131CrossRefPubMed Kim YH, Park JW, Kim JS (2013) Is diaphyseal stem fixation necessary for primary total hip arthroplasty in patients with osteoporotic bone (Class C bone)? J Arthroplasty 28(1):139–146.e131CrossRefPubMed
16.
Zurück zum Zitat McElroy MJ, Johnson AJ, Mont MA, Bonutti PM (2011) Short and standard stem prostheses are both viable options for minimally invasive total hip arthroplasty. Bull NYU Hosp Jt Dis 69(Suppl 1):S68–S76PubMed McElroy MJ, Johnson AJ, Mont MA, Bonutti PM (2011) Short and standard stem prostheses are both viable options for minimally invasive total hip arthroplasty. Bull NYU Hosp Jt Dis 69(Suppl 1):S68–S76PubMed
17.
Zurück zum Zitat Schmidutz F, Beirer M, Weber P, Mazoochian F, Fottner A, Jansson V (2012) Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36(7):1341–1347CrossRefPubMedPubMedCentral Schmidutz F, Beirer M, Weber P, Mazoochian F, Fottner A, Jansson V (2012) Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36(7):1341–1347CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242CrossRefPubMed Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242CrossRefPubMed
19.
Zurück zum Zitat Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg 51-A:737–755CrossRef Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg 51-A:737–755CrossRef
20.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15(12):1833–1840PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15(12):1833–1840PubMed
21.
Zurück zum Zitat Gruen T, McNeice G, Amstutz H (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27 Gruen T, McNeice G, Amstutz H (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27
22.
Zurück zum Zitat Zweymüller K (2007) Good results with an uncoated grit-blasted tapered straight stem at 10 years. Interactive Surgery 2(3):197–205CrossRef Zweymüller K (2007) Good results with an uncoated grit-blasted tapered straight stem at 10 years. Interactive Surgery 2(3):197–205CrossRef
23.
Zurück zum Zitat Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr (1997) Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am 79(7):1007–1012CrossRefPubMed Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr (1997) Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am 79(7):1007–1012CrossRefPubMed
24.
Zurück zum Zitat Brooker A, Bowerman J, Robinson R, Riley LJ (1973) Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg (Am) 55(8):1629–1632CrossRef Brooker A, Bowerman J, Robinson R, Riley LJ (1973) Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg (Am) 55(8):1629–1632CrossRef
25.
Zurück zum Zitat Kjellberg M, Englund E, Sayed-Noor AS (2009) A new radiographic method of measuring femoral offset. The Sundsvall method. Hip Int 19(4):377–381CrossRefPubMed Kjellberg M, Englund E, Sayed-Noor AS (2009) A new radiographic method of measuring femoral offset. The Sundsvall method. Hip Int 19(4):377–381CrossRefPubMed
26.
27.
Zurück zum Zitat Rometsch E, Bos P, Koes B (2012) Survival of short hip stems with a “modern”, trochanter-sparing design—a systematic literature review. Hip Int 22(4):344–354CrossRefPubMed Rometsch E, Bos P, Koes B (2012) Survival of short hip stems with a “modern”, trochanter-sparing design—a systematic literature review. Hip Int 22(4):344–354CrossRefPubMed
28.
Zurück zum Zitat Burchard R, Braas S, Soost C, Graw JA, Schmitt J (2017) Bone preserving level of osteotomy in short-stem total hip arthroplasty does not influence stress shielding dimensions—a comparing finite elements analysis. BMC Musculoskelet Disord 18:343CrossRefPubMedPubMedCentral Burchard R, Braas S, Soost C, Graw JA, Schmitt J (2017) Bone preserving level of osteotomy in short-stem total hip arthroplasty does not influence stress shielding dimensions—a comparing finite elements analysis. BMC Musculoskelet Disord 18:343CrossRefPubMedPubMedCentral
29.
Zurück zum Zitat Kim YH, Kim JS, Joo JH, Park JW (2012) A prospective short-term outcome study of a short metaphyseal fitting total hip arthroplasty. J Arthroplasty 27(1):88–94CrossRefPubMed Kim YH, Kim JS, Joo JH, Park JW (2012) A prospective short-term outcome study of a short metaphyseal fitting total hip arthroplasty. J Arthroplasty 27(1):88–94CrossRefPubMed
30.
Zurück zum Zitat Muller M, Abdel MP, Wassilew GI, Duda G, Perka C (2015) Do post-operative changes of neck-shaft angle and femoral component anteversion have an effect on clinical outcome following uncemented total hip arthroplasty? Bone Joint J 97-b(12):1615–1622CrossRefPubMed Muller M, Abdel MP, Wassilew GI, Duda G, Perka C (2015) Do post-operative changes of neck-shaft angle and femoral component anteversion have an effect on clinical outcome following uncemented total hip arthroplasty? Bone Joint J 97-b(12):1615–1622CrossRefPubMed
31.
Zurück zum Zitat Nawabi DH, Do HT, Ruel A, Lurie B, Elpers ME, Wright T, Potter HG, Westrich GH (2016) Comprehensive analysis of a recalled modular total hip system and recommendations for management. J Bone Joint Surg Am 98(1):40–47CrossRefPubMed Nawabi DH, Do HT, Ruel A, Lurie B, Elpers ME, Wright T, Potter HG, Westrich GH (2016) Comprehensive analysis of a recalled modular total hip system and recommendations for management. J Bone Joint Surg Am 98(1):40–47CrossRefPubMed
32.
Zurück zum Zitat Kop AM, Swarts E (2009) Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. J Arthroplasty 24(7):1019–1023CrossRefPubMed Kop AM, Swarts E (2009) Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. J Arthroplasty 24(7):1019–1023CrossRefPubMed
33.
Zurück zum Zitat Ollivier M, Parratte S, Galland A, Lunebourg A, Argenson JN (2015) Are titanium-on-titanium TiAl6V4 modular necks safe in total hip arthroplasty for non-overweight patients? Results of a prospective series at a minimum follow-up of 7 years. Eur J Orthop Surg Traumatol 25(7):1147–1152CrossRefPubMed Ollivier M, Parratte S, Galland A, Lunebourg A, Argenson JN (2015) Are titanium-on-titanium TiAl6V4 modular necks safe in total hip arthroplasty for non-overweight patients? Results of a prospective series at a minimum follow-up of 7 years. Eur J Orthop Surg Traumatol 25(7):1147–1152CrossRefPubMed
34.
Zurück zum Zitat Omlor GW, Kretzer JP, Reinders J, Streit MR, Bruckner T, Gotterbarm T, Aldinger PR, Merle C (2013) In vivo serum titanium ion levels following modular neck total hip arthroplasty—10 year results in 67 patients. Acta Biomater 9(4):6278–6282CrossRefPubMed Omlor GW, Kretzer JP, Reinders J, Streit MR, Bruckner T, Gotterbarm T, Aldinger PR, Merle C (2013) In vivo serum titanium ion levels following modular neck total hip arthroplasty—10 year results in 67 patients. Acta Biomater 9(4):6278–6282CrossRefPubMed
Metadaten
Titel
Femoral neck preservation with a short hip stem produced with powder manufacturing: mid-term results of a consecutive case series
verfasst von
Marco Schiraldi
Manuel Bondi
Lodovico Renzi Brivio
Publikationsdatum
28.01.2019
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 4/2019
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-019-02381-y

Weitere Artikel der Ausgabe 4/2019

European Journal of Orthopaedic Surgery & Traumatology 4/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.