Skip to main content
Erschienen in: International Orthopaedics 3/2018

27.09.2017 | Original Paper

Glenoid morphology and the safe zone for protecting the suprascapular nerve during baseplate fixation in reverse shoulder arthroplasty

verfasst von: Yuhui Yang, Jianlin Zuo, Tong Liu, Pu Shao, Haihe Wu, Zhongli Gao, Jianlin Xiao

Erschienen in: International Orthopaedics | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to investigate glenoid morphology and define the safe zone for protecting the suprascapular nerve baseplate screw during baseplate fixation in reverse shoulder arthroplasty (RSA) in a Chinese population.

Methods

Shoulder computed tomography (CT) scans from 56 subjects were retrospectively reviewed. Three-dimensional (3D) reconstruction was performed using Mimics software, and corresponding bony references were used to evaluate glenoid morphology. To standardize evaluation, the coronal scapular plane was defined. Safe fixation distances and screw placements were investigated by constructing a simulated cutting plane of the baseplate during RSA.

Results

Mean glenoid height was 35.83 ± 2.95 mm, and width was 27.32 ± 2.78 mm, with significant sexual dimorphism (p < 0.01). According to the cutting plane morphology, the average baseplate radius was 13.84 ± 1.34 mm. The distances from the suprascapular notch and from two bony reference points at the base of the scapular spine to the cutting plane were 30.27 ± 2.77 mm, 18.39 ± 1.67 mm and 16.52 ± 1.52 mm, respectively, with a gender-related difference. Based on the clock face indication system, the danger zone caused by the suprascapular nerve projection was oriented between the two o’clock and eight o’clock positions in reference to the right shoulder.

Conclusions

Glenoid size and the safe zone for screw fixation during RSA were characterized in a Chinese population. Careful consideration of baseplate fixation and avoidance of suprascapular nerve injury are important for improved clinical outcome.
Literatur
3.
Zurück zum Zitat Ji JH, Shafi M, Jeong JJ, Ha JY (2016) Reverse total shoulder arthroplasty in the treatment of chronic anterior fracture dislocation complicated by a chronic full thickness retracted rotator cuff tear in an elderly patient. J Orthop Science 21(2):237–240. https://doi.org/10.1016/j.jos.2015.06.004 Ji JH, Shafi M, Jeong JJ, Ha JY (2016) Reverse total shoulder arthroplasty in the treatment of chronic anterior fracture dislocation complicated by a chronic full thickness retracted rotator cuff tear in an elderly patient. J Orthop Science 21(2):237–240. https://​doi.​org/​10.​1016/​j.​jos.​2015.​06.​004
16.
Zurück zum Zitat Levy JC, Everding NG, Frankle MA, Keppler LJ (2014) Accuracy of patient-specific guided glenoid baseplate positioning for reverse shoulder arthroplasty. J Shoulder Elbow Surg 23(10):1563–1567CrossRefPubMed Levy JC, Everding NG, Frankle MA, Keppler LJ (2014) Accuracy of patient-specific guided glenoid baseplate positioning for reverse shoulder arthroplasty. J Shoulder Elbow Surg 23(10):1563–1567CrossRefPubMed
17.
Zurück zum Zitat Dilisio MF, Warner JJ, Walch G (2016) Accuracy of the Subchondral smile and surface referencing techniques in reverse shoulder Arthroplasty. Orthopedics 39(4):e615–e620CrossRefPubMed Dilisio MF, Warner JJ, Walch G (2016) Accuracy of the Subchondral smile and surface referencing techniques in reverse shoulder Arthroplasty. Orthopedics 39(4):e615–e620CrossRefPubMed
18.
Zurück zum Zitat Trouilloud P, Gonzalvez M, Martz P, Charles H, Handelberg F, Nyffeler R, Baulot E (2014) Duocentric® reversed shoulder prosthesis and personal fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching. Eur J Orthop Surg Traumatol 24(4):483–495CrossRefPubMed Trouilloud P, Gonzalvez M, Martz P, Charles H, Handelberg F, Nyffeler R, Baulot E (2014) Duocentric® reversed shoulder prosthesis and personal fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching. Eur J Orthop Surg Traumatol 24(4):483–495CrossRefPubMed
19.
23.
Zurück zum Zitat Faul F, Erdfelder E, Lang A-G, Buchner A (2007) G* power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39(2):175–191CrossRefPubMed Faul F, Erdfelder E, Lang A-G, Buchner A (2007) G* power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39(2):175–191CrossRefPubMed
27.
Zurück zum Zitat Jha SC, Fukuta S, Wada K, Higasino K, Amari-Kita R, Tsutsui T, Goto T, Hamada D, Suzue N, Matsuura T, Nishisho T, Abe M, Takata Y, Sakai T, Nagamachi A, Sairyo K (2016) Optimizing baseplate position in reverse total shoulder arthroplasty in small-sized Japanese females: technical notes and literature review. J Medical Investig 63(1-2):8–14. https://doi.org/10.2152/jmi.63.8 CrossRef Jha SC, Fukuta S, Wada K, Higasino K, Amari-Kita R, Tsutsui T, Goto T, Hamada D, Suzue N, Matsuura T, Nishisho T, Abe M, Takata Y, Sakai T, Nagamachi A, Sairyo K (2016) Optimizing baseplate position in reverse total shoulder arthroplasty in small-sized Japanese females: technical notes and literature review. J Medical Investig 63(1-2):8–14. https://​doi.​org/​10.​2152/​jmi.​63.​8 CrossRef
31.
Zurück zum Zitat Mathews S, Burkhard M, Serrano N, Link K, Hausler M, Frater N, Franke I, Bischofberger H, Buck FM, Gascho D, Thali M, Serowy S, Muller-Gerbl M, Harper G, Qureshi F, Boni T, Bloch HR, Ullrich O, Ruhli FJ, Eppler E (2017) Glenoid morphology in light of anatomical and reverse total shoulder arthroplasty: a dissection- and 3D-CT-based study in male and female body donors. BMC Musculoskelet Disord 18(1):9. https://doi.org/10.1186/s12891-016-1373-4 CrossRefPubMedPubMedCentral Mathews S, Burkhard M, Serrano N, Link K, Hausler M, Frater N, Franke I, Bischofberger H, Buck FM, Gascho D, Thali M, Serowy S, Muller-Gerbl M, Harper G, Qureshi F, Boni T, Bloch HR, Ullrich O, Ruhli FJ, Eppler E (2017) Glenoid morphology in light of anatomical and reverse total shoulder arthroplasty: a dissection- and 3D-CT-based study in male and female body donors. BMC Musculoskelet Disord 18(1):9. https://​doi.​org/​10.​1186/​s12891-016-1373-4 CrossRefPubMedPubMedCentral
35.
Zurück zum Zitat Bigliani LU, Dalsey RM, McCann PD, April EW (1990) An anatomical study of the suprascapular nerve. Arthroscopy 6(4):301–305CrossRefPubMed Bigliani LU, Dalsey RM, McCann PD, April EW (1990) An anatomical study of the suprascapular nerve. Arthroscopy 6(4):301–305CrossRefPubMed
36.
Zurück zum Zitat Ekin A, Magden O, Iche C (1995) Anatomy and relationship of the suprascapular nerve. Surgery of the shoulder. Elsevier, NY Ekin A, Magden O, Iche C (1995) Anatomy and relationship of the suprascapular nerve. Surgery of the shoulder. Elsevier, NY
38.
Zurück zum Zitat Perez A, Navas I, Herencias A, Marco F, Sanudo J, Simon C, Vazquez T (2016) Morphometry of the suprascapular nerve in the supraspinous fossa. Eur J Anat 20(3):215–220 Perez A, Navas I, Herencias A, Marco F, Sanudo J, Simon C, Vazquez T (2016) Morphometry of the suprascapular nerve in the supraspinous fossa. Eur J Anat 20(3):215–220
39.
Zurück zum Zitat Frankle MA, Teramoto A, Luo Z-P, Levy JC, Pupello D (2009) Glenoid morphology in reverse shoulder arthroplasty: classification and surgical implications. J Shoulder Elb Surg 18(6):874–885CrossRef Frankle MA, Teramoto A, Luo Z-P, Levy JC, Pupello D (2009) Glenoid morphology in reverse shoulder arthroplasty: classification and surgical implications. J Shoulder Elb Surg 18(6):874–885CrossRef
Metadaten
Titel
Glenoid morphology and the safe zone for protecting the suprascapular nerve during baseplate fixation in reverse shoulder arthroplasty
verfasst von
Yuhui Yang
Jianlin Zuo
Tong Liu
Pu Shao
Haihe Wu
Zhongli Gao
Jianlin Xiao
Publikationsdatum
27.09.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 3/2018
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3646-4

Weitere Artikel der Ausgabe 3/2018

International Orthopaedics 3/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.