Skip to main content
Erschienen in: International Orthopaedics 2/2015

01.02.2015 | Original Paper

Glenoid rim fracture through anchor points after arthroscopic Bankart repair for shoulder instability

verfasst von: Jin-Young Park, Seung-Jun Lee, Se-Kwan Oh, KyungSoo Oh, YoungMin Noh, Kuen-Tak Suh

Erschienen in: International Orthopaedics | Ausgabe 2/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

We studied the incidence of postoperative glenoid rim fractures and analysed the relationships of glenoid rim fracture with osteolysis, fracture pattern, number of anchors and postoperative activity after arthroscopic Bankart repair with suture anchor fixation.

Methods

Among 570 patients of the Bankart repair group, nine patients who had undergone revision arthroscopy for glenoid rim fracture after initial Bankart repair with at least two years post-revision follow-up were enrolled. Mean age was 28.8 years (range, 18–49 years), and mean follow-up was 36.4 months (range, 25–64 months). The mean time from Bankart repair to failure of initial surgery following trauma was 27.3 months (range, four to–84 months). Initial suture anchors were made of bioabsorbable composites (poly-d-l-lactic acid, PDLLA) without ceramic osteo-filler (seven cases) and metals (two cases). PDLLA without ceramic osteo-filler suture anchors were used for revision surgery. We reviewed 570 patients for relationship between osteolysis and glenoid rim fracture.

Results

Five patients including three and two with bioabsorbable and metal suture anchors, respectively, experienced glenoid rim fracture at more than two years postoperatively. Osteolysis around initial suture anchors groups showed higher glenoid rim fracture incidence compared with the control group (odd ratio =4.186 [95 % CI, 1.108–15.818]; p = 0.037).

Conclusions

Osteolysis related to insertion of metal or PLDDA suture anchors may lead to glenoid rim fracture. Remnant metal or bioabsorbable suture anchors without ceramic composite could be a stress riser at two years postoperatively.
Literatur
1.
Zurück zum Zitat Athanasiou KA, Agrawal CM, Barber FA, Burkhart SS (1998) Orthopaedic applications for PLA-PGA biodegradable polymers. Arthroscopy 14:726–737PubMedCrossRef Athanasiou KA, Agrawal CM, Barber FA, Burkhart SS (1998) Orthopaedic applications for PLA-PGA biodegradable polymers. Arthroscopy 14:726–737PubMedCrossRef
2.
Zurück zum Zitat Athwal GS, Shridharani SM, O'Driscoll SW (2006) Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. A report of four cases. J Bone Joint Surg Am 88:1840–1845. doi:10.2106/JBJS.E.00721 PubMedCrossRef Athwal GS, Shridharani SM, O'Driscoll SW (2006) Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. A report of four cases. J Bone Joint Surg Am 88:1840–1845. doi:10.​2106/​JBJS.​E.​00721 PubMedCrossRef
7.
8.
10.
Zurück zum Zitat Freehill MQ, Harms DJ, Huber SM, Atlihan D, Buss DD (2003) Poly-L-lactic acid tack synovitis after arthroscopic stabilization of the shoulder. Am J Sports Med 31:643–647PubMed Freehill MQ, Harms DJ, Huber SM, Atlihan D, Buss DD (2003) Poly-L-lactic acid tack synovitis after arthroscopic stabilization of the shoulder. Am J Sports Med 31:643–647PubMed
12.
Zurück zum Zitat Gaenslen ES, Satterlee CC, Hinson GW (1996) Magnetic resonance imaging for evaluation of failed repairs of the rotator cuff. Relationship to operative findings. J Bone Joint Surg Am 78:1391–1396PubMed Gaenslen ES, Satterlee CC, Hinson GW (1996) Magnetic resonance imaging for evaluation of failed repairs of the rotator cuff. Relationship to operative findings. J Bone Joint Surg Am 78:1391–1396PubMed
14.
15.
16.
Zurück zum Zitat Gunja NJ, Athanasiou KA (2006) Biodegradable materials in arthroscopy. Sports Med Arthrosc 14:112–119PubMedCrossRef Gunja NJ, Athanasiou KA (2006) Biodegradable materials in arthroscopy. Sports Med Arthrosc 14:112–119PubMedCrossRef
17.
Zurück zum Zitat Hasegawa S, Tamura J, Neo M, Goto K, Shikinami Y, Saito M et al (2005) In vivo evaluation of a porous hydroxyapatite/poly-DL-lactide composite for use as a bone substitute. J Biomed Mater Res A 75:567–579. doi:10.1002/jbm.a.30460 PubMedCrossRef Hasegawa S, Tamura J, Neo M, Goto K, Shikinami Y, Saito M et al (2005) In vivo evaluation of a porous hydroxyapatite/poly-DL-lactide composite for use as a bone substitute. J Biomed Mater Res A 75:567–579. doi:10.​1002/​jbm.​a.​30460 PubMedCrossRef
18.
Zurück zum Zitat Hecker AT, Shea M, Hayhurst JO, Myers ER, Meeks LW, Hayes WC (1993) Pull-out strength of suture anchors for rotator cuff and Bankart lesion repairs. Am J Sports Med 21:874–879PubMedCrossRef Hecker AT, Shea M, Hayhurst JO, Myers ER, Meeks LW, Hayes WC (1993) Pull-out strength of suture anchors for rotator cuff and Bankart lesion repairs. Am J Sports Med 21:874–879PubMedCrossRef
19.
Zurück zum Zitat Kaar TK, Schenck RC Jr, Wirth MA, Rockwood CA Jr (2001) Complications of metallic suture anchors in shoulder surgery: a report of 8 cases. Arthroscopy 17:31–37PubMedCrossRef Kaar TK, Schenck RC Jr, Wirth MA, Rockwood CA Jr (2001) Complications of metallic suture anchors in shoulder surgery: a report of 8 cases. Arthroscopy 17:31–37PubMedCrossRef
21.
Zurück zum Zitat Muller M, Kaab MJ, Villiger C, Holzach P (2002) Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial. Injury 33(Suppl 2):B30–B36PubMedCrossRef Muller M, Kaab MJ, Villiger C, Holzach P (2002) Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial. Injury 33(Suppl 2):B30–B36PubMedCrossRef
25.
Zurück zum Zitat Silver MD, Daigneault JP (2000) Symptomatic interarticular migration of glenoid suture anchors. Arthroscopy 16:102–105PubMedCrossRef Silver MD, Daigneault JP (2000) Symptomatic interarticular migration of glenoid suture anchors. Arthroscopy 16:102–105PubMedCrossRef
26.
Zurück zum Zitat Spoliti M (2007) Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor. Acta Orthop Belg 73:107–110PubMed Spoliti M (2007) Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor. Acta Orthop Belg 73:107–110PubMed
27.
Zurück zum Zitat Sugaya H, Moriishi J, Kanisawa I, Tsuchiya A (2006) Arthroscopic osseous Bankart repair for chronic recurrent traumatic anterior glenohumeral instability. Surgical technique. J Bone Joint Surg Am 88:159–169. doi:10.2106/JBJS.F.00319 PubMed Sugaya H, Moriishi J, Kanisawa I, Tsuchiya A (2006) Arthroscopic osseous Bankart repair for chronic recurrent traumatic anterior glenohumeral instability. Surgical technique. J Bone Joint Surg Am 88:159–169. doi:10.​2106/​JBJS.​F.​00319 PubMed
28.
Zurück zum Zitat Van der Linde JA, Van Kampen DA, Terwee CB, Dijksman LM, Kleinjan G, Willems WJ (2011) Long-term results after arthroscopic shoulder stabilization using suture anchors: an 8- to 10-year follow up. Am J Sports Med 39:2396–2403. doi:10.1177/0363546511415657 PubMedCrossRef Van der Linde JA, Van Kampen DA, Terwee CB, Dijksman LM, Kleinjan G, Willems WJ (2011) Long-term results after arthroscopic shoulder stabilization using suture anchors: an 8- to 10-year follow up. Am J Sports Med 39:2396–2403. doi:10.​1177/​0363546511415657​ PubMedCrossRef
29.
Zurück zum Zitat Vasenius J, Vainionpaa S, Vihtonen K, Makela A, Rokkanen P, Mero M et al (1990) Comparison of in vitro hydrolysis, subcutaneous and intramedullary implantation to evaluate the strength retention of absorbable osteosynthesis implants. Biomaterials 11:501–504PubMedCrossRef Vasenius J, Vainionpaa S, Vihtonen K, Makela A, Rokkanen P, Mero M et al (1990) Comparison of in vitro hydrolysis, subcutaneous and intramedullary implantation to evaluate the strength retention of absorbable osteosynthesis implants. Biomaterials 11:501–504PubMedCrossRef
30.
Zurück zum Zitat Waris E, Ashammakhi N, Happonen H, Raatikainen T, Kaarela O, Tormala P, et al. (2003) Bioabsorbable miniplating versus metallic fixation for metacarpal fractures. Clin Orthop Relat Res 410:310–319. doi:10.1097/01.blo.0000063789.32430.c6 Waris E, Ashammakhi N, Happonen H, Raatikainen T, Kaarela O, Tormala P, et al. (2003) Bioabsorbable miniplating versus metallic fixation for metacarpal fractures. Clin Orthop Relat Res 410:310–319. doi:10.1097/01.blo.0000063789.32430.c6
31.
Zurück zum Zitat Weiler A, Hoffmann RF, Stahelin AC, Helling HJ, Sudkamp NP (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16:305–321PubMedCrossRef Weiler A, Hoffmann RF, Stahelin AC, Helling HJ, Sudkamp NP (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16:305–321PubMedCrossRef
32.
Metadaten
Titel
Glenoid rim fracture through anchor points after arthroscopic Bankart repair for shoulder instability
verfasst von
Jin-Young Park
Seung-Jun Lee
Se-Kwan Oh
KyungSoo Oh
YoungMin Noh
Kuen-Tak Suh
Publikationsdatum
01.02.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 2/2015
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2604-7

Weitere Artikel der Ausgabe 2/2015

International Orthopaedics 2/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.