Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 7/2016

22.04.2016 | Clinical Research

How Often Does Spindle Failure Occur in Compressive Osseointegration Endoprostheses for Oncologic Reconstruction?

verfasst von: Lauren H. Goldman, MD, Lee J. Morse, MD, Richard J. O’Donnell, MD, Rosanna L. Wustrack, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 7/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

Compressive osseointegration is a promising modality for limb salvage in distal femoral oncologic tumors. However, few studies have explored short-term survival rates in a large patient cohort of distal femur compressive endoprostheses or highlighted the risk factors for spindle failures.

Questions/purposes

We asked: (1) What is the frequency of compressive osseointegration spindle failure in distal femoral reconstructions? (2) What are the characteristics of rotational failure cases with distal femur compressive osseointegration endoprostheses? (3) What are the risk factors for mechanical and rotational failure of distal femur compressive osseointegration implantation? (4) What are other modalities of failure or causes of revision surgery, which affect patients undergoing distal femur compressive osseointegration implantation for oncologic reconstruction?

Methods

Between 1996 and 2013, 127 distal femoral reconstructions with the Compress® prosthesis were performed in 121 patients. During that time, 116 Compress® prostheses were implanted for aggressive primary tumors of the distal femur and/or failure of previous oncologic reconstruction. This approach represented approximately 91% of the distal femoral reconstructions performed during that time. Of the patients with prostheses implanted, four patients (four of 116, 3%) had died, and 37 (37 of 116, 32%) were lost to followup before 24 months. The median followup was 84 months (range, 24–198 months), and 71 patients (66% of all patients) were seen within the last 3 years. A retrospective chart review was performed to determine failure modality as defined by radiographs, clinical history, and intraoperative findings. Risk factors including age, sex, BMI, resection length, and perioperative chemotherapy were analyzed to determine effect on spindle and rotational failure rates. Survival analysis was determined using the Kaplan-Meier estimator. Differences in survival between groups were analyzed using the log rank test. Risk factors were determined using Cox proportional hazard modeling.

Results

Spindle survival at 5 and 10 years was 91% (95% CI, 82%–95%). Survival rates from rotational failure at 5 and 10 years were 92% (95% CI, 83%–96%); the majority of failures occurred within the first 2 years postoperatively and were the result of a twisting mechanism of injury. With the numbers available, none of the potential risk factors examined were associated with mechanical failure. The 5-year and 10-year all-cause revision-free survival rates were 57% (95% CI, 44%–67%) and 50% (95% CI, 36%–61%), respectively.

Conclusions

Distal femur compressive osseointegration is a viable method for endoprosthetic reconstruction. Rotational failure is rare with the majority occurring early. No variables were found to correlate with increased risk of mechanical failure. More research is needed to evaluate methods of preventing mechanical and rotational failures in addition to other common causes of revision such as infection in these massive endoprosthetic reconstructions.

Level of Evidence

Level IV, therapeutic study.
Literatur
1.
Zurück zum Zitat Avedian RS, Goldsby RE, Kramer MJ, O’Donnell RJ. Effect of chemotherapy on initial compressive osseointegration of tumor endoprostheses. Clin Orthop Relat Res. 2007;459:48–53.CrossRefPubMed Avedian RS, Goldsby RE, Kramer MJ, O’Donnell RJ. Effect of chemotherapy on initial compressive osseointegration of tumor endoprostheses. Clin Orthop Relat Res. 2007;459:48–53.CrossRefPubMed
2.
Zurück zum Zitat Bhangu AA, Kramer MJ, Grimer RJ, O’Donnell RJ. Early distal femoral endoprosthetic survival: cemented stems versus the Compress® implant. Int Orthop. 2006;30:465–472.CrossRefPubMedPubMedCentral Bhangu AA, Kramer MJ, Grimer RJ, O’Donnell RJ. Early distal femoral endoprosthetic survival: cemented stems versus the Compress® implant. Int Orthop. 2006;30:465–472.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Bini SA, Johnston JO, Martin DL. Compliant prestress fixation in tumor prostheses: interface retrieval data. Orthopedics. 2000:707–711; discussion 711–712. Bini SA, Johnston JO, Martin DL. Compliant prestress fixation in tumor prostheses: interface retrieval data. Orthopedics. 2000:707–711; discussion 711–712.
4.
Zurück zum Zitat Calvert GT, Cummings JE, Bowles AJ, Jones KB, Wurtz LD, Randall RL. A dual-center review of compressive osseointegration for fixation of massive endoprosthetics: 2- to 9-year followup. Clin Orthop Relat Res. 2014;472:822–829.CrossRefPubMedPubMedCentral Calvert GT, Cummings JE, Bowles AJ, Jones KB, Wurtz LD, Randall RL. A dual-center review of compressive osseointegration for fixation of massive endoprosthetics: 2- to 9-year followup. Clin Orthop Relat Res. 2014;472:822–829.CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Cristofolini L, Bini SA, Toni A. In vitro testing of a novel limb salvage prosthesis for the distal femur. Clin Biomech (Bristol, Avon). 1998;13:608–615. Cristofolini L, Bini SA, Toni A. In vitro testing of a novel limb salvage prosthesis for the distal femur. Clin Biomech (Bristol, Avon). 1998;13:608–615.
6.
Zurück zum Zitat Eilber FR, Eckhardt J, Morton DL. Advances in the treatment of sarcomas of the extremity: current status of limb salvage. Cancer. 1984;54(11 suppl):2695–2701.CrossRefPubMed Eilber FR, Eckhardt J, Morton DL. Advances in the treatment of sarcomas of the extremity: current status of limb salvage. Cancer. 1984;54(11 suppl):2695–2701.CrossRefPubMed
7.
Zurück zum Zitat Farfalli GL, Boland PJ, Morris CD, Athanasian EA, Healey JH. Early equivalence of uncemented press-fit and Compress® femoral fixation. Clin Orthop Relat Res. 2009;467:2792–2799.CrossRefPubMedPubMedCentral Farfalli GL, Boland PJ, Morris CD, Athanasian EA, Healey JH. Early equivalence of uncemented press-fit and Compress® femoral fixation. Clin Orthop Relat Res. 2009;467:2792–2799.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Grimer RJ, Carter SR, Pynsent PB. The cost-effectiveness of limb salvage for bone tumours. J Bone Joint Surg Br. 1997;79:558–561.CrossRefPubMed Grimer RJ, Carter SR, Pynsent PB. The cost-effectiveness of limb salvage for bone tumours. J Bone Joint Surg Br. 1997;79:558–561.CrossRefPubMed
9.
Zurück zum Zitat Guo W, Ji T, Yang R, Tang X, Yang Y. Endoprosthetic replacement for primary tumours around the knee: experience from Peking University. J Bone Joint Surg Br. 2008;90:1084–1089.CrossRefPubMed Guo W, Ji T, Yang R, Tang X, Yang Y. Endoprosthetic replacement for primary tumours around the knee: experience from Peking University. J Bone Joint Surg Br. 2008;90:1084–1089.CrossRefPubMed
10.
Zurück zum Zitat Harrell FE Jr, Lee KL, Pollock BG. Regression models in clinical studies: determining relationships between predictors and response. J Natl Cancer Inst. 1988;80:1198–1202.CrossRefPubMed Harrell FE Jr, Lee KL, Pollock BG. Regression models in clinical studies: determining relationships between predictors and response. J Natl Cancer Inst. 1988;80:1198–1202.CrossRefPubMed
11.
Zurück zum Zitat Healey JH, Morris CD, Athanasian EA, Boland BJ. Compress® knee arthroplasty has 80% 10-year survivorship and novel forms of bone failure. Clin Orthop Relat Res. 2013;471:774–783.CrossRefPubMedPubMedCentral Healey JH, Morris CD, Athanasian EA, Boland BJ. Compress® knee arthroplasty has 80% 10-year survivorship and novel forms of bone failure. Clin Orthop Relat Res. 2013;471:774–783.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Henderson ER, Groundland JS, Pala E, Dennis JA, Wooten R, Cheong D, Windhager R, Kotz RI, Mercuri M, Funovics PT, Hornicek FJ, Temple HT, Ruggieri P, Letson GD. Failure mode classification for tumor endoprostheses: retrospective review of five institutions and a literature review. J Bone Joint Surg Am. 2011;93:418–429.CrossRefPubMed Henderson ER, Groundland JS, Pala E, Dennis JA, Wooten R, Cheong D, Windhager R, Kotz RI, Mercuri M, Funovics PT, Hornicek FJ, Temple HT, Ruggieri P, Letson GD. Failure mode classification for tumor endoprostheses: retrospective review of five institutions and a literature review. J Bone Joint Surg Am. 2011;93:418–429.CrossRefPubMed
13.
Zurück zum Zitat Kaplan EL, Meier P. Nonparametric observations from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef Kaplan EL, Meier P. Nonparametric observations from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef
14.
Zurück zum Zitat Kawai A, Muschler GF, Lane JM, Otis JC, Healey JH. Prosthetic knee replacement after resection of a malignant tumor of the distal part of the femur: medium to long-term results. J Bone Joint Surg Am. 1998;80:636–647.CrossRefPubMed Kawai A, Muschler GF, Lane JM, Otis JC, Healey JH. Prosthetic knee replacement after resection of a malignant tumor of the distal part of the femur: medium to long-term results. J Bone Joint Surg Am. 1998;80:636–647.CrossRefPubMed
15.
Zurück zum Zitat Kinkel S, Lehner B, Kleinhans JA, Jakubowitz E, Ewerbeck V, Heisel C. Medium to long-term results after reconstruction of bone defects at the knee with tumor endoprostheses. J Surg Oncol. 2010;101:166–169.PubMed Kinkel S, Lehner B, Kleinhans JA, Jakubowitz E, Ewerbeck V, Heisel C. Medium to long-term results after reconstruction of bone defects at the knee with tumor endoprostheses. J Surg Oncol. 2010;101:166–169.PubMed
16.
Zurück zum Zitat Kramer MJ, Tanner BJ, Horval AE, O’Donnell RJ. Compressive osseointegration promotes viable bone at the endoprosthetic interface: retrieval study of Compress® implants. Int Orthop. 2008;32:567–571.CrossRefPubMedPubMedCentral Kramer MJ, Tanner BJ, Horval AE, O’Donnell RJ. Compressive osseointegration promotes viable bone at the endoprosthetic interface: retrieval study of Compress® implants. Int Orthop. 2008;32:567–571.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Monument MJ, Bernthal NM, Bowles AJ, Jones KB, Randall RL. What are the 5-year survivorship outcomes of compressive endoprosthetic osseointegration fixation of the femur? Clin Orthop Relat Res. 2015;473:883–890.CrossRefPubMedPubMedCentral Monument MJ, Bernthal NM, Bowles AJ, Jones KB, Randall RL. What are the 5-year survivorship outcomes of compressive endoprosthetic osseointegration fixation of the femur? Clin Orthop Relat Res. 2015;473:883–890.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat O’Donnell RJ. Compressive osseointegration of modular endoprostheses. Curr Opin Orthop. 2007;18:590–603.CrossRef O’Donnell RJ. Compressive osseointegration of modular endoprostheses. Curr Opin Orthop. 2007;18:590–603.CrossRef
19.
20.
Zurück zum Zitat Pedtke AC, Wustrack RL, Fang AS, Grimer RJ, O’Donnell RJ. Aseptic failure: how does the Compress® implant compare to cemented stems? Clin Orthop Relat Res. 2012;470:735–742.CrossRefPubMedPubMedCentral Pedtke AC, Wustrack RL, Fang AS, Grimer RJ, O’Donnell RJ. Aseptic failure: how does the Compress® implant compare to cemented stems? Clin Orthop Relat Res. 2012;470:735–742.CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Sluga M, Windhager R, Lang S, Heinzl H, Bielack S, Kotz R. Local and systemic control after ablative and limb sparing surgery in patients with osteosarcoma. Clin Orthop Relat Res. 1999;358:120–127.CrossRefPubMed Sluga M, Windhager R, Lang S, Heinzl H, Bielack S, Kotz R. Local and systemic control after ablative and limb sparing surgery in patients with osteosarcoma. Clin Orthop Relat Res. 1999;358:120–127.CrossRefPubMed
22.
Zurück zum Zitat Tyler WK, Healey JH, Morris CD, Boland PJ, O’Donnell RJ. Compress® periprosthetic fractures: interface stability and ease of revision. Clin Orthop Relat Res. 2009;467:2800–2806.CrossRefPubMedPubMedCentral Tyler WK, Healey JH, Morris CD, Boland PJ, O’Donnell RJ. Compress® periprosthetic fractures: interface stability and ease of revision. Clin Orthop Relat Res. 2009;467:2800–2806.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Unwin PS, Cannon SR, Grimer RJ, Kemp HB, Sneath RS, Walker PS. Aseptic loosening in cemented custom-made prosthetic replacements for bone tumours of the lower limb. J Bone Joint Surg Br. 1996;78:5–13.PubMed Unwin PS, Cannon SR, Grimer RJ, Kemp HB, Sneath RS, Walker PS. Aseptic loosening in cemented custom-made prosthetic replacements for bone tumours of the lower limb. J Bone Joint Surg Br. 1996;78:5–13.PubMed
24.
Zurück zum Zitat Unwin PS, Cobb JP, Walker PS. Distal femoral arthroplasty using custom-made prostheses: the first 218 cases. J Arthroplasty. 1993;8:259–268.CrossRefPubMed Unwin PS, Cobb JP, Walker PS. Distal femoral arthroplasty using custom-made prostheses: the first 218 cases. J Arthroplasty. 1993;8:259–268.CrossRefPubMed
25.
Zurück zum Zitat Zimel MN, Farfalli GL, Zindman AM, Riedel ER, Morris CD, Boland PJ, Healey JH. Revision distal femoral arthroplasty with the Compress® prosthesis has a low rate of mechanical failure at 10 years. Clin Orthop Relat Res. 2016;474:528–536.CrossRefPubMed Zimel MN, Farfalli GL, Zindman AM, Riedel ER, Morris CD, Boland PJ, Healey JH. Revision distal femoral arthroplasty with the Compress® prosthesis has a low rate of mechanical failure at 10 years. Clin Orthop Relat Res. 2016;474:528–536.CrossRefPubMed
Metadaten
Titel
How Often Does Spindle Failure Occur in Compressive Osseointegration Endoprostheses for Oncologic Reconstruction?
verfasst von
Lauren H. Goldman, MD
Lee J. Morse, MD
Richard J. O’Donnell, MD
Rosanna L. Wustrack, MD
Publikationsdatum
22.04.2016
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 7/2016
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-016-4839-7

Weitere Artikel der Ausgabe 7/2016

Clinical Orthopaedics and Related Research® 7/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.