Abstract

Background

Methods to improve gap balancing in total knee arthroplasty (TKA) include the development of calibrated distractors and various devices to determine the distances of the gaps. However, few studies have validated the accuracy or precision of computer navigation to determine these measurements, especially gaps created after bone cuts have been made; doing so would be important, because optimal surgical technique relies on appropriate gap spacing.

Questions/purposes

We investigated the ability of a new image-free computer navigation surface registration protocol to measure gap distances in TKA.

Methods

Eight embalmed cadaveric specimens of the lower extremity were used. A surface registration software protocol defined the most distal and posterior surface points of the femoral condyles and the navigation system measured the distance of the most distal femoral condyle point to the surface of the tibia after tibial resection. The tibial resection was perpendicular to the mechanical axis and was cut with a 7° posterior slope. The navigation system measured gaps spaced by modular spacing blocks at 5° intervals from full extension to 120° of flexion. Repeatability assessed repeated measures by one surgeon. Reproducibility was assessed by performing the same measurements after complete reregistration of the computer protocol to the cadaver bones.

Results

The gaps measured by the computer were statistically the same as those assessed with the use of blocks with a maximum measurement error of 1 mm. Reregistration did introduce error into the measurement. The gaps changed with position of knee flexion, and there was gradual and significant stretching of the gaps with repeated measurements.

Conclusions

Preliminary testing shows that computer navigation can reproduce static measurements reliably and with equal accuracy as spacer blocks. We have not demonstrated that this could be applied in a dynamic setting.

Clinical Relevance

This computer navigation system has sufficient precision to warrant investigation in the clinical setting for measuring gaps created during the surgical procedure.
Literatur
1.
Zurück zum Zitat Bellemans J, D’Hooghe P, Vandenneucker H, Van Damme G, Victor J. Soft tissue balance in total knee arthroplasty: does stress relaxation occur perioperatively? Clin Orthop Relat Res. 2006;452:49–52PubMedCrossRef Bellemans J, D’Hooghe P, Vandenneucker H, Van Damme G, Victor J. Soft tissue balance in total knee arthroplasty: does stress relaxation occur perioperatively? Clin Orthop Relat Res. 2006;452:49–52PubMedCrossRef
2.
Zurück zum Zitat Davis ET, Pagkalos J, Gallie PA, Macgroarty K, Waddell JP, Schemitsch EH. Defining the errors in the registration process during imageless computer navigation in total knee arthroplasty: a cadaveric study. J Arthroplasty. 2014;29:698–701PubMedCrossRef Davis ET, Pagkalos J, Gallie PA, Macgroarty K, Waddell JP, Schemitsch EH. Defining the errors in the registration process during imageless computer navigation in total knee arthroplasty: a cadaveric study. J Arthroplasty. 2014;29:698–701PubMedCrossRef
3.
Zurück zum Zitat Hamelynk KJ. The rheumatoid knee. In: Hamelynk KJ, Stiehl JB, eds. LCS ® Mobile Bearing Knee Arthroplasty: A 25 Years Worldwide Experience. Heidelberg, Germany: Springer-Verlag; 2002CrossRef Hamelynk KJ. The rheumatoid knee. In: Hamelynk KJ, Stiehl JB, eds. LCS ® Mobile Bearing Knee Arthroplasty: A 25 Years Worldwide Experience. Heidelberg, Germany: Springer-Verlag; 2002CrossRef
4.
Zurück zum Zitat Insall J, Scott WN, Ranawat CS. The total condylar knee prosthesis: report of 220 cases. J Bone Joint Surg Am. 1979;61:173–180PubMed Insall J, Scott WN, Ranawat CS. The total condylar knee prosthesis: report of 220 cases. J Bone Joint Surg Am. 1979;61:173–180PubMed
5.
Zurück zum Zitat Matsumoto T, Kuroda R, Kubo S, Muratsu H, Muzuno K, Kurosaka M. The intra-operative joint gap in cruciate-retaining compared with posterior-stabilized total knee replacement. J Bone Joint Surg Br. 2009;91:475–480PubMedCrossRef Matsumoto T, Kuroda R, Kubo S, Muratsu H, Muzuno K, Kurosaka M. The intra-operative joint gap in cruciate-retaining compared with posterior-stabilized total knee replacement. J Bone Joint Surg Br. 2009;91:475–480PubMedCrossRef
6.
Zurück zum Zitat Nowakowski AM, Majewski M, Muller-Gerbl M, Valderrabano V. Development of a force-determining tensor to measure ‘physiologic knee ligament gaps’ without bone resection using a total knee arthroplasty approach. J Orthop Sci. 2011;16:56–63PubMedCrossRef Nowakowski AM, Majewski M, Muller-Gerbl M, Valderrabano V. Development of a force-determining tensor to measure ‘physiologic knee ligament gaps’ without bone resection using a total knee arthroplasty approach. J Orthop Sci. 2011;16:56–63PubMedCrossRef
7.
Zurück zum Zitat Nowakowski AM, Majewski M, Muller-Gerbl M, Valderrabano V. Measurement of knee joint gaps without bone resection: ‘physiologic’ extension and flexion gaps in total knee arthroplasty are asymmetric and unequal and anterior and posterior ligament resections produce different gap changes. J Orthop Res. 2012;30:522–527PubMedCrossRef Nowakowski AM, Majewski M, Muller-Gerbl M, Valderrabano V. Measurement of knee joint gaps without bone resection: ‘physiologic’ extension and flexion gaps in total knee arthroplasty are asymmetric and unequal and anterior and posterior ligament resections produce different gap changes. J Orthop Res. 2012;30:522–527PubMedCrossRef
8.
Zurück zum Zitat Perrin N, Stindel E, Roux C. BoneMorphing versus freehand localization of anatomical landmarks: consequences for the reproducibility of implant positioning in total knee arthroplasty. Comput Aided Surg. 2005;10:301–309PubMedCrossRef Perrin N, Stindel E, Roux C. BoneMorphing versus freehand localization of anatomical landmarks: consequences for the reproducibility of implant positioning in total knee arthroplasty. Comput Aided Surg. 2005;10:301–309PubMedCrossRef
9.
Zurück zum Zitat Ranawat AS, Ranawat CS, Elkus M, Rasquinha VJ, Rossi R, Babhulkar S. Total knee arthroplasty for severe valgus deformity. J Bone Joint Surg Am. 2005;87:271–284PubMed Ranawat AS, Ranawat CS, Elkus M, Rasquinha VJ, Rossi R, Babhulkar S. Total knee arthroplasty for severe valgus deformity. J Bone Joint Surg Am. 2005;87:271–284PubMed
10.
Zurück zum Zitat Siston RA, Goodman SB, Delp SL, Giori NJ. Coronal plane stability before and after total knee arthroplasty. Clin Orthop Relat Res. 2007;463:43–49PubMed Siston RA, Goodman SB, Delp SL, Giori NJ. Coronal plane stability before and after total knee arthroplasty. Clin Orthop Relat Res. 2007;463:43–49PubMed
11.
Zurück zum Zitat Siston RA, Goodman SB, Patel JJ, Delp SL, Giori NJ. The variability of tibial rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2006;452:65–69PubMedCrossRef Siston RA, Goodman SB, Patel JJ, Delp SL, Giori NJ. The variability of tibial rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2006;452:65–69PubMedCrossRef
12.
Zurück zum Zitat Stindel E, Briard JL, Merloz P, Plaweski S, Dubrana F, Lefevre C, Troccaz J. Bone morphing: 3D morphological data for total knee arthroplasty. Comput Aided Surg. 2002;7:156–168PubMedCrossRef Stindel E, Briard JL, Merloz P, Plaweski S, Dubrana F, Lefevre C, Troccaz J. Bone morphing: 3D morphological data for total knee arthroplasty. Comput Aided Surg. 2002;7:156–168PubMedCrossRef
13.
Zurück zum Zitat Tanaka K, Muratsu H, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M. Soft tissue balance measurement in anterior cruciate ligament-resected knee joint: cadaveric study as a model for cruciate-retaining total knee arthroplasty. J Orthop Sci. 2007;12:149–153PubMedCrossRef Tanaka K, Muratsu H, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M. Soft tissue balance measurement in anterior cruciate ligament-resected knee joint: cadaveric study as a model for cruciate-retaining total knee arthroplasty. J Orthop Sci. 2007;12:149–153PubMedCrossRef
14.
Zurück zum Zitat Van Damme G, Defoort K, Ducoulombier Y, Van Glabbeek F, Bellemans J, Victor J. What should the surgeon aim for when performing computer assisted total knee arthroplasty. J Bone Joint Surg Am. 2005;87(Suppl 2):52–58PubMedCrossRef Van Damme G, Defoort K, Ducoulombier Y, Van Glabbeek F, Bellemans J, Victor J. What should the surgeon aim for when performing computer assisted total knee arthroplasty. J Bone Joint Surg Am. 2005;87(Suppl 2):52–58PubMedCrossRef
15.
Zurück zum Zitat Yau WP, Leung A, Liu KG, Yan CH, Wong LL, Chiu KY. Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation assisted total knee arthroplasty. J Arthroplasty. 2007;22:1150–1161PubMedCrossRef Yau WP, Leung A, Liu KG, Yan CH, Wong LL, Chiu KY. Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation assisted total knee arthroplasty. J Arthroplasty. 2007;22:1150–1161PubMedCrossRef
Metadaten
Titel
How Precise Is Computer-navigated Gap Assessment in TKA?
verfasst von
James B. Stiehl, MD
David A. Heck, MD
Publikationsdatum
01.01.2015
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 1/2015
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-014-3785-5

Weitere Artikel der Ausgabe 1/2015

Clinical Orthopaedics and Related Research® 1/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.