Skip to main content
Erschienen in: International Orthopaedics 12/2016

01.03.2016 | Original Paper

How to best measure femoral length and lateralisation after total hip arthroplasty on antero-posterior pelvic radiographs

verfasst von: Nicolas Bonin, Laurent Jacquot, Laurent Boulard, Patrick Reynaud, Mo Saffarini, Sébastien Lustig

Erschienen in: International Orthopaedics | Ausgabe 12/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Various methods exist for measuring limb length and lateralisation after total hip arthroplasty. Most of them utilise standard anteroposterior (AP) pelvic radiographs, but their results can be affected by patient position during imaging and thus the position of the lower limb on the coronal plane. The aim of this study is to evaluate how commonly used measuring methods of limb lengthening and femoral offset are affected by the position of the lower limb in the coronal plane.

Methods

A standing pelvic AP radiograph post implantation of a right total hip prosthesis was digitised. The right femur and its femoral stem were digitally segmented, such that they could be positioned orthogonal to the pelvis horizontal reference, with 10° of adduction, and with 10° of abduction, with respect to the centre of rotation. Various limb lengths and implant lateralisation were also digitised. We obtained nine x-rays differing one to three variables. Twice four independent surgeons performed three femoral length measurement methods and femoral offset measurement methods. Intra and inter-observer error as well as the effect of the femoral position on the measurements were studied.

Results

With respect to length measurements, the distance between the centre of rotation (C) and the tip of the lesser trochanter (LT) increased by 3 mm per cm of lateralisation. This measurement was not affected by the hip position in abduction or adduction. The distance between the tip of the lesser or greater trochanter (GT) and the horizontal passing through the centre of rotation was strongly affected by the hip position in abduction or adduction. With respect to offset, the distance between the centre of rotation and the greater trochanter (C-GT) was the most consistent and was not affected by variations in lengths or femoral axis. At the level of the lesser trochanter, the distance of the femoral anatomical axis and to Perkin’s line was heavily influenced by the femoral position.

Conclusion

The C-LT distance was consistent in measuring limb length and the C-GT distance was reliable in determining femoral offset regardless of the relative position of the femur.
Literatur
1.
Zurück zum Zitat Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg (Br) 80(3):382–390CrossRef Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg (Br) 80(3):382–390CrossRef
2.
Zurück zum Zitat White TO, Dougall TW (2002) Arthroplasty of the hip. Leg length is not important. J Bone Joint Surg (Br) 84(3):335–338CrossRef White TO, Dougall TW (2002) Arthroplasty of the hip. Leg length is not important. J Bone Joint Surg (Br) 84(3):335–338CrossRef
3.
Zurück zum Zitat Della Valle AG, Padgett DE, Salvati EA (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13(7):455–462CrossRefPubMed Della Valle AG, Padgett DE, Salvati EA (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13(7):455–462CrossRefPubMed
4.
Zurück zum Zitat Konyves A, Bannister GC (2005) The importance of leg length discrepancy after total hip arthroplasty. J Bone Joint Surg (Br) 87(2):155–157CrossRef Konyves A, Bannister GC (2005) The importance of leg length discrepancy after total hip arthroplasty. J Bone Joint Surg (Br) 87(2):155–157CrossRef
5.
Zurück zum Zitat Debarge R, Lustig S, Neyret P, Ait Si Selmi T (2008) Confrontation of the radiographic preoperative planning with the postoperative data for uncemented total hip arthroplasty. Rev Chir Orthop Reparatrice Appar Mot 94(4):368–375CrossRefPubMed Debarge R, Lustig S, Neyret P, Ait Si Selmi T (2008) Confrontation of the radiographic preoperative planning with the postoperative data for uncemented total hip arthroplasty. Rev Chir Orthop Reparatrice Appar Mot 94(4):368–375CrossRefPubMed
6.
Zurück zum Zitat Unnanuntana A, Wagner D, Goodman SB (2009) The accuracy of preoperative templating in cementless total hip arthroplasty. J Arthroplasty 24(2):180–186CrossRefPubMed Unnanuntana A, Wagner D, Goodman SB (2009) The accuracy of preoperative templating in cementless total hip arthroplasty. J Arthroplasty 24(2):180–186CrossRefPubMed
7.
Zurück zum Zitat Steinberg B, Harris, W (1992) The offset problem in total hip arthroplasty. Contemp Orthop 24:556 Steinberg B, Harris, W (1992) The offset problem in total hip arthroplasty. Contemp Orthop 24:556
8.
Zurück zum Zitat Shaarani SR, McHugh G, Collins DA (2013) Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. J Arthroplasty 28(2):331–337CrossRefPubMed Shaarani SR, McHugh G, Collins DA (2013) Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. J Arthroplasty 28(2):331–337CrossRefPubMed
9.
Zurück zum Zitat Williamson JA, Reckling FW (1978) Limb length discrepancy and related problems following total hip joint replacement. Clin Orthop Relat Res 134:135–138 Williamson JA, Reckling FW (1978) Limb length discrepancy and related problems following total hip joint replacement. Clin Orthop Relat Res 134:135–138
10.
Zurück zum Zitat Hausselle J, Moreau PE, Wessely L, de Thomasson E, Assi A, Parratte S, Essig J, Skalli W (2012) Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study. Int Orthop 36(8):1567–1573CrossRefPubMedPubMedCentral Hausselle J, Moreau PE, Wessely L, de Thomasson E, Assi A, Parratte S, Essig J, Skalli W (2012) Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study. Int Orthop 36(8):1567–1573CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Craiovan B, Renkawitz T, Weber M, Grifka J, Nolte L, Zheng G (2014) Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate? Int Orthop 38(10):2009–2015CrossRefPubMed Craiovan B, Renkawitz T, Weber M, Grifka J, Nolte L, Zheng G (2014) Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate? Int Orthop 38(10):2009–2015CrossRefPubMed
12.
Zurück zum Zitat Kim YH, Cho KH, Park YG (2015) Is the acetabular cup orientation after total hip arthroplasty on a two-dimensional or three-dimensional model accurate? Int Orthop 39(4):819–820CrossRefPubMed Kim YH, Cho KH, Park YG (2015) Is the acetabular cup orientation after total hip arthroplasty on a two-dimensional or three-dimensional model accurate? Int Orthop 39(4):819–820CrossRefPubMed
13.
Zurück zum Zitat Tsai TY, Dimitriou D, Li G, Kwon YM (2014) Does total hip arthroplasty restore native hip anatomy? three-dimensional reconstruction analysis. Int Orthop 38(8):1577–1583CrossRefPubMedPubMedCentral Tsai TY, Dimitriou D, Li G, Kwon YM (2014) Does total hip arthroplasty restore native hip anatomy? three-dimensional reconstruction analysis. Int Orthop 38(8):1577–1583CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Schmidutz F, Beirer M, Weber P, Mazoochian F, Fottner A, Jansson V (2012) Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36(7):1341–1347CrossRefPubMedPubMedCentral Schmidutz F, Beirer M, Weber P, Mazoochian F, Fottner A, Jansson V (2012) Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36(7):1341–1347CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Goodman SB, Adler SJ, Fyhrie DP, Schurman DJ (1988) The acetabular teardrop and its relevance to acetabular migration. Clin Orthop Relat Res 236:199–204 Goodman SB, Adler SJ, Fyhrie DP, Schurman DJ (1988) The acetabular teardrop and its relevance to acetabular migration. Clin Orthop Relat Res 236:199–204
16.
Zurück zum Zitat Meermans G, Malik A, Witt J, Haddad F (2011) Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty. Clin Orthop Relat Res 469(6):1677–1682CrossRefPubMed Meermans G, Malik A, Witt J, Haddad F (2011) Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty. Clin Orthop Relat Res 469(6):1677–1682CrossRefPubMed
17.
Zurück zum Zitat Charnley J (1979) Low friction arthroplasty of the hip: theory and practice. Springer, New YorkCrossRef Charnley J (1979) Low friction arthroplasty of the hip: theory and practice. Springer, New YorkCrossRef
18.
Zurück zum Zitat Liebs TR, Nasser L, Herzberg W, Ruther W, Hassenpflug J (2014) The influence of femoral offset on health-related quality of life after total hip replacement. Bone Joint J 96-B(1):36–42CrossRefPubMed Liebs TR, Nasser L, Herzberg W, Ruther W, Hassenpflug J (2014) The influence of femoral offset on health-related quality of life after total hip replacement. Bone Joint J 96-B(1):36–42CrossRefPubMed
19.
Zurück zum Zitat Gamble P, de Beer J, Petruccelli D, Winemaker M (2010) The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty 25(4):529–532CrossRefPubMed Gamble P, de Beer J, Petruccelli D, Winemaker M (2010) The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty 25(4):529–532CrossRefPubMed
20.
Zurück zum Zitat Kumar PG, Kirmani SJ, Humberg H, Kavarthapu V, Li P (2009) Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software. Orthopedics 32(11):815PubMed Kumar PG, Kirmani SJ, Humberg H, Kavarthapu V, Li P (2009) Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software. Orthopedics 32(11):815PubMed
21.
Zurück zum Zitat The B, Verdonschot N, van Horn JR, van Ooijen PM, Diercks RL (2007) Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties. J Arthroplasty 22(6):866–870CrossRefPubMed The B, Verdonschot N, van Horn JR, van Ooijen PM, Diercks RL (2007) Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties. J Arthroplasty 22(6):866–870CrossRefPubMed
22.
Zurück zum Zitat Sariali E, Mouttet A, Pasquier G, Durante E, Catone Y (2009) Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg (Br) 91(3):333–340CrossRef Sariali E, Mouttet A, Pasquier G, Durante E, Catone Y (2009) Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg (Br) 91(3):333–340CrossRef
23.
Zurück zum Zitat Pasquier G, Ducharne G, Ali ES, Giraud F, Mouttet A, Durante E (2010) Total hip arthroplasty offset measurement: is C T scan the most accurate option? Orthop Traumatol Surg Res 96(4):367–375CrossRefPubMed Pasquier G, Ducharne G, Ali ES, Giraud F, Mouttet A, Durante E (2010) Total hip arthroplasty offset measurement: is C T scan the most accurate option? Orthop Traumatol Surg Res 96(4):367–375CrossRefPubMed
Metadaten
Titel
How to best measure femoral length and lateralisation after total hip arthroplasty on antero-posterior pelvic radiographs
verfasst von
Nicolas Bonin
Laurent Jacquot
Laurent Boulard
Patrick Reynaud
Mo Saffarini
Sébastien Lustig
Publikationsdatum
01.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 12/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3145-z

Weitere Artikel der Ausgabe 12/2016

International Orthopaedics 12/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.