Skip to main content
Erschienen in: Clinical Oral Investigations 4/2007

01.12.2007 | Original Article

In vitro analysis of the radiodensity of indirect composites and ceramic inlay systems and its influence on the detection of cement overhangs

verfasst von: Carlos José Soares, Fernanda Ribeiro Santana, Rodrigo Borges Fonseca, Luis Roberto Marcondes Martins, Francisco Haiter Neto

Erschienen in: Clinical Oral Investigations | Ausgabe 4/2007

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate the radiodensity of indirect restorative systems and to determine its influence on detection of resin cement overhangs. Sixty sound molars with similar dimensions were selected, and MOD inlay preparations were made in a standardized fashion with 6° taper of the walls. Restorations were made with a porcelain, Duceram LFC, and with three indirect composites, Solidex, Artglass, and Targis. Digital radiographic images were taken before and after cementation of the inlays (Digora system) and were analyzed on two regions, the cervical and the isthmus floor. Digital radiodensity measurements were performed on standardized points symmetrically distributed over each restoration and tooth structure. Cement overhangs were detected through visual analysis by three evaluators. Data were statistically analyzed utilizing ANOVA following Tukey’s test (p < 0.05), showing that Solidex presented lower radiodensity than Duceram LFC, and both Artglass and Targis presented similar higher levels of radiodensity than the other groups. Radiodensity of cervical regions was always greater than for isthmus floor regions. Detection of the resin cement overhangs is easier observed on Solidex and Duceram LFC. Radiodensity is highly influenced by restorative material type and tooth regions. The detection of radiopaque resin cement overhangs is influenced by radiodensity of restorative materials.
Literatur
1.
Zurück zum Zitat Arnetzl GV, Arnetzl G (2006) Design of preparations for all-ceramic inlay materials. Int J Comput Dent 9:289–298PubMed Arnetzl GV, Arnetzl G (2006) Design of preparations for all-ceramic inlay materials. Int J Comput Dent 9:289–298PubMed
2.
Zurück zum Zitat Bouschlicher MR, Cobb DS, Boyer DB (1999) Radiopacity of compomers, flowable and conventional resin composites for posterior restorations. Oper Dent 24:20–25PubMed Bouschlicher MR, Cobb DS, Boyer DB (1999) Radiopacity of compomers, flowable and conventional resin composites for posterior restorations. Oper Dent 24:20–25PubMed
3.
Zurück zum Zitat Curtis PM Jr, von Fraunhofer JA, Farman AG (1990) The radiographic density of composite restorative resins. Oral Surg Oral Med Oral Pathol 70:226–230PubMedCrossRef Curtis PM Jr, von Fraunhofer JA, Farman AG (1990) The radiographic density of composite restorative resins. Oral Surg Oral Med Oral Pathol 70:226–230PubMedCrossRef
4.
Zurück zum Zitat Dietschi D, Maeder M, Holz J (1992) In vitro evaluation of marginal fit and morphology of fired ceramic inlays. Quintessence Int 23:271–278PubMed Dietschi D, Maeder M, Holz J (1992) In vitro evaluation of marginal fit and morphology of fired ceramic inlays. Quintessence Int 23:271–278PubMed
5.
Zurück zum Zitat Espelid I, Tveit AB, Erickson RL, Keck SC, Glasspoole EA (1991) Radiopacity of restorations and detection of secondary caries. Dent Mater 7:114–117PubMedCrossRef Espelid I, Tveit AB, Erickson RL, Keck SC, Glasspoole EA (1991) Radiopacity of restorations and detection of secondary caries. Dent Mater 7:114–117PubMedCrossRef
6.
Zurück zum Zitat Farman TT, Farman AG, Scarfe WC, Goldsmith LJ (1996) Optical densities of dental resin composites: a comparison of CCD, storage phosphor, and Ektaspeed plus radiographic film. Gen Dent 44:532–537PubMed Farman TT, Farman AG, Scarfe WC, Goldsmith LJ (1996) Optical densities of dental resin composites: a comparison of CCD, storage phosphor, and Ektaspeed plus radiographic film. Gen Dent 44:532–537PubMed
7.
Zurück zum Zitat Fonseca RB, Branco CA, Soares PV, Correr-Sobrinho L, Haiter-Neto F, Fernandes-Neto AJ, Soares CJ (2006) Radiodensity of base, liner and luting dental materials. Clin Oral Investig 10:114–118PubMedCrossRef Fonseca RB, Branco CA, Soares PV, Correr-Sobrinho L, Haiter-Neto F, Fernandes-Neto AJ, Soares CJ (2006) Radiodensity of base, liner and luting dental materials. Clin Oral Investig 10:114–118PubMedCrossRef
8.
Zurück zum Zitat Fraga RC, Luca-Fraga LR, Pimenta LA (2000) Physical properties of resinous cements: an in vitro study. J Oral Rehabil 27:1064–1067PubMedCrossRef Fraga RC, Luca-Fraga LR, Pimenta LA (2000) Physical properties of resinous cements: an in vitro study. J Oral Rehabil 27:1064–1067PubMedCrossRef
9.
Zurück zum Zitat Gemalmaz D, Ozcan M, Yoruc AB, Alkumru HN (1997) Marginal adaptation of a sintered ceramic inlay system before and after cementation. J Oral Rehabil 24:646–651PubMedCrossRef Gemalmaz D, Ozcan M, Yoruc AB, Alkumru HN (1997) Marginal adaptation of a sintered ceramic inlay system before and after cementation. J Oral Rehabil 24:646–651PubMedCrossRef
10.
Zurück zum Zitat Goshima T, Goshima Y (1989) The optimum level of radiopacity in posterior composite resins. Dentomaxillofacial Radiol 18:19–21 Goshima T, Goshima Y (1989) The optimum level of radiopacity in posterior composite resins. Dentomaxillofacial Radiol 18:19–21
11.
Zurück zum Zitat Gu XH, Kern M (2003) Marginal discrepancies and leakage of all-ceramic crowns: influence of luting agents and aging conditions. Int J Prosthodont 16:109–116PubMed Gu XH, Kern M (2003) Marginal discrepancies and leakage of all-ceramic crowns: influence of luting agents and aging conditions. Int J Prosthodont 16:109–116PubMed
12.
Zurück zum Zitat Inokoshi S, Van Meerbeek B, Willems G, Lambrechts P, Braem M, Vanherle G (1992) Marginal accuracy of CAD/CAM inlays made with the original and the updated software. J Dent 20:171–177PubMedCrossRef Inokoshi S, Van Meerbeek B, Willems G, Lambrechts P, Braem M, Vanherle G (1992) Marginal accuracy of CAD/CAM inlays made with the original and the updated software. J Dent 20:171–177PubMedCrossRef
13.
Zurück zum Zitat Kreulen CM, van Amerongen WE, Borgmeijer PJ, Akerboom HB, Gruythuysen RJ (1994) Radiographic assessments of class II resin composite inlays. ASDC J Dent Child 61:192–198PubMed Kreulen CM, van Amerongen WE, Borgmeijer PJ, Akerboom HB, Gruythuysen RJ (1994) Radiographic assessments of class II resin composite inlays. ASDC J Dent Child 61:192–198PubMed
14.
Zurück zum Zitat Molin MK, Karlsson SL (2000) A randomized 5-year clinical evaluation of 3 ceramic inlay systems. Int J Prosthodont 13:194–200PubMed Molin MK, Karlsson SL (2000) A randomized 5-year clinical evaluation of 3 ceramic inlay systems. Int J Prosthodont 13:194–200PubMed
15.
Zurück zum Zitat O’Rourke B, Walls AW, Wassell RW (1995) Radiographic detection of overhangs formed by resin composite luting agents. J Dent 23:353–357PubMedCrossRef O’Rourke B, Walls AW, Wassell RW (1995) Radiographic detection of overhangs formed by resin composite luting agents. J Dent 23:353–357PubMedCrossRef
16.
Zurück zum Zitat Otto T, De Nisco S (2002) Computer-aided direct ceramic restorations: a 10-year prospective clinical study of Cerec CAD/CAM inlays and onlays. Int J Prosthodont 15:122–128PubMed Otto T, De Nisco S (2002) Computer-aided direct ceramic restorations: a 10-year prospective clinical study of Cerec CAD/CAM inlays and onlays. Int J Prosthodont 15:122–128PubMed
17.
Zurück zum Zitat Soares CJ, Martins LR, Fernandes Neto AJ, Giannini M (2003) Marginal adaptation of indirect composites and ceramic inlay systems. Oper Dent 28:689–694PubMed Soares CJ, Martins LR, Fernandes Neto AJ, Giannini M (2003) Marginal adaptation of indirect composites and ceramic inlay systems. Oper Dent 28:689–694PubMed
18.
Zurück zum Zitat Stanford CM, Fan PL, Schoenfeld CM, Knoeppel R, Stanford JW (1987) Radiopacity of light-cured posterior composite resins. J Am Dent Assoc 115:722–724PubMed Stanford CM, Fan PL, Schoenfeld CM, Knoeppel R, Stanford JW (1987) Radiopacity of light-cured posterior composite resins. J Am Dent Assoc 115:722–724PubMed
19.
Zurück zum Zitat Touati B, Aidan N (1997) Second generation laboratory composite resins for indirect restorations. J Esthet Dent 9:108–118PubMedCrossRef Touati B, Aidan N (1997) Second generation laboratory composite resins for indirect restorations. J Esthet Dent 9:108–118PubMedCrossRef
20.
Zurück zum Zitat Touati B (1996) The evolution of aesthetic restorative materials for inlays and onlays: a review. Pract Periodontics Aesthet Dent 8:657–666 (quiz 668)PubMed Touati B (1996) The evolution of aesthetic restorative materials for inlays and onlays: a review. Pract Periodontics Aesthet Dent 8:657–666 (quiz 668)PubMed
21.
Zurück zum Zitat Tveit AB, Espelid I (1986) Radiographic diagnosis of caries and marginal defects in connection with radiopaque composite fillings. Dent Mater 2:159–162PubMedCrossRef Tveit AB, Espelid I (1986) Radiographic diagnosis of caries and marginal defects in connection with radiopaque composite fillings. Dent Mater 2:159–162PubMedCrossRef
22.
Zurück zum Zitat Versteeg CH, Sanderink GC, van der Stelt PF (1997) Efficacy of digital intra-oral radiography in clinical dentistry. J Dent 25:215–224PubMedCrossRef Versteeg CH, Sanderink GC, van der Stelt PF (1997) Efficacy of digital intra-oral radiography in clinical dentistry. J Dent 25:215–224PubMedCrossRef
23.
Zurück zum Zitat Wenzel A, Hintze H, Horsted-Bindslev P (1998) Discrimination between restorative dental materials by their radiopacity measured in film radiographs and digital images. J Forensic Odontostomatol 16:8–13PubMed Wenzel A, Hintze H, Horsted-Bindslev P (1998) Discrimination between restorative dental materials by their radiopacity measured in film radiographs and digital images. J Forensic Odontostomatol 16:8–13PubMed
Metadaten
Titel
In vitro analysis of the radiodensity of indirect composites and ceramic inlay systems and its influence on the detection of cement overhangs
verfasst von
Carlos José Soares
Fernanda Ribeiro Santana
Rodrigo Borges Fonseca
Luis Roberto Marcondes Martins
Francisco Haiter Neto
Publikationsdatum
01.12.2007
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 4/2007
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-007-0130-3

Weitere Artikel der Ausgabe 4/2007

Clinical Oral Investigations 4/2007 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.