Skip to main content
Erschienen in: Lasers in Medical Science 6/2009

01.11.2009 | Original Article

In vitro and in vivo studies of osteoblast cell response to a titanium-6 aluminium-4 vanadium surface modified by neodymium:yttrium–aluminium–garnet laser and silicon carbide paper

verfasst von: M. E. Khosroshahi, M. Mahmoodi, H. Saeedinasab

Erschienen in: Lasers in Medical Science | Ausgabe 6/2009

Einloggen, um Zugang zu erhalten

Abstract

The effects of neodymium:yttrium–aluminium–garnet (Nd:YAG) laser and silicon carbide (SiC) paper on the surface micro-topography of titanium-6 aluminium-4 vanadium (Ti6Al4V) alloy were examined in relation to the response of bone cells. The study was performed in three distinct stages: (1) after surface treatment of samples by laser and SiC paper, the surface hardness, surface roughness, corrosion resistance and surface tension were evaluated; (2) the growth of mouse connective tissue fibroblast cells (L-929) on untreated and treated samples was assessed in vitro; (3) the response of goat osteoblast cells to untreated and treated implanted samples was assessed in vivo. The surface roughness varied between 7 ± 0.02 for laser-treated samples (LTSs) at 140 J cm−2 and 21.8 ± 0.05 for mechanically treated samples (MTSs). The surface hardness was found to vary from 377 Vickers hardness number (VHN) for MTSs to 850 VHN for LTSs. A corrosion potential of −0.21V was achieved for the LTSs compared with −0.51V for the MTSs. The LTSs exhibited a more hydrophilic behaviour (i.e. wettability) than did the MTSs. No cytotoxicity effect, unlike for the MTSs, was observed for the LTSs. The results of in vivo tests indicated longitudinal growth of osteoblast cells along the grooves on the samples formed by the SiC paper, and multidirectional spreading of the cells on the LTSs.
Literatur
2.
Zurück zum Zitat Buchter A, Kleinheinz J, Wiesman HP, Kersken J, Nienkemper M, Weyhrother H, Joos U, Meyer U (2005) Biological and biomechanical evaluation of bone remodelling and implant stability after using an osteotome technique. Clin Oral Implants Res 1:1–8 Buchter A, Kleinheinz J, Wiesman HP, Kersken J, Nienkemper M, Weyhrother H, Joos U, Meyer U (2005) Biological and biomechanical evaluation of bone remodelling and implant stability after using an osteotome technique. Clin Oral Implants Res 1:1–8
4.
Zurück zum Zitat Lavose-Valereto IC, Wolynec S, Deboni MC, Konig B Jr (2001) In vitro and in vivo biocompatibility testing of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating. J Biomed Mater Res 58:727–733. doi:10.1002/jbm.1072 CrossRef Lavose-Valereto IC, Wolynec S, Deboni MC, Konig B Jr (2001) In vitro and in vivo biocompatibility testing of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating. J Biomed Mater Res 58:727–733. doi:10.​1002/​jbm.​1072 CrossRef
5.
6.
Zurück zum Zitat Cheroudi B, Soorany E, Black N, Weston L (1995) Computer-assisted three-dimensional reconstruction of epithelial cells attached to percutaneous implant. J Biomed Mater Res 29:371–379. doi:10.1002/jbm.820290312 CrossRef Cheroudi B, Soorany E, Black N, Weston L (1995) Computer-assisted three-dimensional reconstruction of epithelial cells attached to percutaneous implant. J Biomed Mater Res 29:371–379. doi:10.​1002/​jbm.​820290312 CrossRef
7.
Zurück zum Zitat Curtis AS, Clark P (2001) The effect of topographic and mechanical properties of materials on cell behavior. Crit Rev Biocompat 9:1313–1329 Curtis AS, Clark P (2001) The effect of topographic and mechanical properties of materials on cell behavior. Crit Rev Biocompat 9:1313–1329
12.
Zurück zum Zitat Tian YS, Chen CZ, Yue TM, Wang ZL (2004) Study on microstructures and mechanical properties of in-situ formed multiphase coating by laser cladding of titanium alloy with silicon and graphite powder. Chin J Lasers 31:1–12 Tian YS, Chen CZ, Yue TM, Wang ZL (2004) Study on microstructures and mechanical properties of in-situ formed multiphase coating by laser cladding of titanium alloy with silicon and graphite powder. Chin J Lasers 31:1–12
16.
Zurück zum Zitat Peyer P, Scherpereel X, Berthe L, Carboni C, Fabbro R, Lemaitre C (2000) Surface modification induced in 316L steel by laser peening and shot-peening: influence of pitting corrosion. Mater Sci Eng 280:294–302. doi:10.1016/S0921–5093(99)00698–X CrossRef Peyer P, Scherpereel X, Berthe L, Carboni C, Fabbro R, Lemaitre C (2000) Surface modification induced in 316L steel by laser peening and shot-peening: influence of pitting corrosion. Mater Sci Eng 280:294–302. doi:10.​1016/​S0921–5093(99)00698–X CrossRef
18.
Zurück zum Zitat Khosroshahi ME, Valanejad A, Tavakoli J (2004) Evaluation of mid-IR laser radiation effect on 316L stainless steel corrosion resistance in physiological saline. Amirkabir J Sci Technol 15:107–115 Khosroshahi ME, Valanejad A, Tavakoli J (2004) Evaluation of mid-IR laser radiation effect on 316L stainless steel corrosion resistance in physiological saline. Amirkabir J Sci Technol 15:107–115
20.
Zurück zum Zitat Arisu HD, Turkoz E, Bala O (2006) Effects of Nd:YAG laser irradiation on osteoblast cell cultures. Lasers Med Sci 21:175–180 Arisu HD, Turkoz E, Bala O (2006) Effects of Nd:YAG laser irradiation on osteoblast cell cultures. Lasers Med Sci 21:175–180
23.
Zurück zum Zitat Wieland M, Textor M, Spencer ND, Brunette DM (2001) Wavelength-roughness: a quantitative approach to characterizing the topography of rough titanium surfaces. Int J Oral Maxillofac Implants 16:163–181PubMed Wieland M, Textor M, Spencer ND, Brunette DM (2001) Wavelength-roughness: a quantitative approach to characterizing the topography of rough titanium surfaces. Int J Oral Maxillofac Implants 16:163–181PubMed
24.
Zurück zum Zitat Ifflander R (2001) Solid state lasers for material processing. Springer series in optical sciences. Ifflander R (2001) Solid state lasers for material processing. Springer series in optical sciences.
25.
Zurück zum Zitat Fan Y, Chen P, Yao YL, Yang Z, Egland K (2005) Effect of phase transformations on laser forming of Ti-6Al-4V alloy. J Appl Phys 98:1–10 Fan Y, Chen P, Yao YL, Yang Z, Egland K (2005) Effect of phase transformations on laser forming of Ti-6Al-4V alloy. J Appl Phys 98:1–10
26.
Zurück zum Zitat Birte GS, Neubert A, Hopp M, Griepentrog M, Lange KP (2003) Fibroblast growth on surface modified dental implants: an in vitro study. J Biomed Mater Res 64A:591–599. doi:10.1002/jbm.a.10417 CrossRef Birte GS, Neubert A, Hopp M, Griepentrog M, Lange KP (2003) Fibroblast growth on surface modified dental implants: an in vitro study. J Biomed Mater Res 64A:591–599. doi:10.​1002/​jbm.​a.​10417 CrossRef
27.
Zurück zum Zitat Sikavitsas VI, Dolder J, Bancroft G, Jansen J (2003) Influence of the in vitro culture period on the in vivo performance of cell/titanium bone tissue-engineered constructs using a rat cranial size defect model. J Biomed Mater Res 67A:944–951. doi:10.1002/jbm.a.10126 CrossRef Sikavitsas VI, Dolder J, Bancroft G, Jansen J (2003) Influence of the in vitro culture period on the in vivo performance of cell/titanium bone tissue-engineered constructs using a rat cranial size defect model. J Biomed Mater Res 67A:944–951. doi:10.​1002/​jbm.​a.​10126 CrossRef
28.
Zurück zum Zitat Fischer P, Leber H, Romano V, Webber HP, Glardon R (2004) Microstructure of near-infrared pulsed laser sintered titanium samples. Appl Phys A Mater Sci Process A78:1219–1227 Fischer P, Leber H, Romano V, Webber HP, Glardon R (2004) Microstructure of near-infrared pulsed laser sintered titanium samples. Appl Phys A Mater Sci Process A78:1219–1227
29.
Zurück zum Zitat Ronold HJ, Lyngstadaas SP, Ellingsen JE (2003) A study on the effect of dual blasting with TiO2 on titanium implant surfaces on functional attachment in bone. J Biomed Mater Res 67A:524–530. doi:10.1002/jbm.a.10580 CrossRef Ronold HJ, Lyngstadaas SP, Ellingsen JE (2003) A study on the effect of dual blasting with TiO2 on titanium implant surfaces on functional attachment in bone. J Biomed Mater Res 67A:524–530. doi:10.​1002/​jbm.​a.​10580 CrossRef
32.
Zurück zum Zitat Perez del Pino A, Serra P, Morenzo JL (2002) Oxidation of titanium through Nd:YAG laser irradiation. Appl Surf Sci 8129:1–4 Perez del Pino A, Serra P, Morenzo JL (2002) Oxidation of titanium through Nd:YAG laser irradiation. Appl Surf Sci 8129:1–4
33.
Zurück zum Zitat Sitting C, Textor M, Spencer ND, Wieland M, Vallotton H (2000) Surface characterization of implant materials c.pTi, Ti-6Al-4V band Ti-6Al-4V with different pretreatments. J Mater Sci Mater Med. 10:35–46 doi:10.1023/A:1008840026907 CrossRef Sitting C, Textor M, Spencer ND, Wieland M, Vallotton H (2000) Surface characterization of implant materials c.pTi, Ti-6Al-4V band Ti-6Al-4V with different pretreatments. J Mater Sci Mater Med. 10:35–46 doi:10.​1023/​A:​1008840026907 CrossRef
34.
Zurück zum Zitat Bern L, English L, Fogarty J, Policoro R, Zsidi A, Vance J, Drelich J, White C, Dunahu S, Rohly K (2004) Effect of surface characteristics of metallic biomaterials on interaction with osteoblast cells. 7th World Biomatarials Congress, pp 1121–1122 Bern L, English L, Fogarty J, Policoro R, Zsidi A, Vance J, Drelich J, White C, Dunahu S, Rohly K (2004) Effect of surface characteristics of metallic biomaterials on interaction with osteoblast cells. 7th World Biomatarials Congress, pp 1121–1122
35.
36.
Metadaten
Titel
In vitro and in vivo studies of osteoblast cell response to a titanium-6 aluminium-4 vanadium surface modified by neodymium:yttrium–aluminium–garnet laser and silicon carbide paper
verfasst von
M. E. Khosroshahi
M. Mahmoodi
H. Saeedinasab
Publikationsdatum
01.11.2009
Verlag
Springer-Verlag
Erschienen in
Lasers in Medical Science / Ausgabe 6/2009
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-008-0628-1

Weitere Artikel der Ausgabe 6/2009

Lasers in Medical Science 6/2009 Zur Ausgabe