Skip to main content
Erschienen in: International Orthopaedics 12/2012

01.12.2012 | Original Paper

In vivo kinematics of high-flex mobile-bearing total knee arthroplasty, with a new post-cam design, in deep knee bending motion

verfasst von: Masahiro Kurita, Tetsuya Tomita, Takaharu Yamazaki, Masakazu Fujii, Kazuma Futai, Norimasa Shimizu, Hideki Yoshikawa, Kazuomi Sugamoto

Erschienen in: International Orthopaedics | Ausgabe 12/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The objective of this study was to evaluate the in vivo knee kinematics to assess the available functional motion of the characteristic mobile-bearing prosthesis design and to examine whether the artificial joint would work in vivo according to its design concept.

Methods

We studied 14 knees (11 patients) implanted with the Vanguard RP Hi-Flex prosthesis. This prosthesis has a highly original form of post-cam called a PS saddle design with high compatibility, and with a rotating plate mobile-bearing mechanism. The cylinder-type post-cam is designed to enable contact in early flexion ranges, and to prevent paradoxical anterior femoral component movement. Each patient performed weight-bearing deep knee bending under fluoroscopic surveillance. Motion between each component including the polyethylene insert was analyzed using the 2D/3D registration technique.

Results

The mean range of motion was 122.0°. The mean femoral component rotation for the tibial tray was 5.0°. No paradoxical anterior movement of the nearest point was confirmed between the femoral component and the tibial tray in the early flexion ranges. Initial contact of the post-cam was confirmed at a knee flexion angle of 33.8°. Subsequently, the wide contact of the post-cam was maintained until flexion reached 120° in all knees, but disengagement of the post-cam was observed in two knees when flexion was ≥130°.

Conclusions

The results of this study demonstrated that the prosthesis design generally works in vivo as intended by its design concept. The present kinematic data may provide useful information for improvement of high-flex type prostheses.
Literatur
1.
Zurück zum Zitat Argenson JN, Parratte S, Ashour A, Komistek RD, Scuderi GR (2008) Patient-reported outcome correlates with knee function after a single-design mobile-bearing TKA. Clin Orthop Relat Res 466:2669–2676PubMedCrossRef Argenson JN, Parratte S, Ashour A, Komistek RD, Scuderi GR (2008) Patient-reported outcome correlates with knee function after a single-design mobile-bearing TKA. Clin Orthop Relat Res 466:2669–2676PubMedCrossRef
2.
Zurück zum Zitat Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89:1457–1461PubMedCrossRef Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89:1457–1461PubMedCrossRef
3.
Zurück zum Zitat Buechel FF Sr (2002) Long-term followup after mobile-bearing total knee replacement. Clin Orthop Relat Res 404:40–50PubMedCrossRef Buechel FF Sr (2002) Long-term followup after mobile-bearing total knee replacement. Clin Orthop Relat Res 404:40–50PubMedCrossRef
4.
Zurück zum Zitat Sorrells RB, Voorhorst PE, Murphy JA, Bauschka MP, Greenwald AS (2004) Uncemented rotating-platform total knee replacement: a five to twelve-year follow-up study. J Bone Joint Surg Am 86:2156–2162PubMed Sorrells RB, Voorhorst PE, Murphy JA, Bauschka MP, Greenwald AS (2004) Uncemented rotating-platform total knee replacement: a five to twelve-year follow-up study. J Bone Joint Surg Am 86:2156–2162PubMed
5.
Zurück zum Zitat Jordan LR, Olivo JL, Voorhorst PE (1997) Survivorship analysis of cementless meniscal bearing total knee arthroplasty. Clin Orthop Relat Res 338:119–123PubMedCrossRef Jordan LR, Olivo JL, Voorhorst PE (1997) Survivorship analysis of cementless meniscal bearing total knee arthroplasty. Clin Orthop Relat Res 338:119–123PubMedCrossRef
6.
Zurück zum Zitat Mahoney OM, Kinsey TL, D’Errico TJ, Shen J (2012) No functional advantage of a mobile bearing posterior stabilized TKA. Clin Orthop Relat Res 470:33–44PubMedCrossRef Mahoney OM, Kinsey TL, D’Errico TJ, Shen J (2012) No functional advantage of a mobile bearing posterior stabilized TKA. Clin Orthop Relat Res 470:33–44PubMedCrossRef
7.
Zurück zum Zitat Lädermann A, Lübbeke A, Stern R, Riand N, Fritschy D (2008) Fixed-bearing versus mobile-bearing total knee arthroplasty: a prospective randomised, clinical and radiological study with mid-term results at 7 years. Knee 15:206–210PubMedCrossRef Lädermann A, Lübbeke A, Stern R, Riand N, Fritschy D (2008) Fixed-bearing versus mobile-bearing total knee arthroplasty: a prospective randomised, clinical and radiological study with mid-term results at 7 years. Knee 15:206–210PubMedCrossRef
8.
Zurück zum Zitat Matsuda S, Mizu-uchi H, Fukagawa S, Miura H, Okazaki K, Matsuda H, Iwamoto Y (2010) Mobile-bearing prosthesis did not improve mid-term clinical results of total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 18:1311–1316PubMedCrossRef Matsuda S, Mizu-uchi H, Fukagawa S, Miura H, Okazaki K, Matsuda H, Iwamoto Y (2010) Mobile-bearing prosthesis did not improve mid-term clinical results of total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 18:1311–1316PubMedCrossRef
9.
Zurück zum Zitat Watanabe T, Tomita T, Fujii M, Hashimoto J, Sugamoto K, Yoshikawa H (2005) Comparison between mobile-bearing and fixed-bearing knees in bilateral total knee replacements. Int Orthop 29:179–181PubMedCrossRef Watanabe T, Tomita T, Fujii M, Hashimoto J, Sugamoto K, Yoshikawa H (2005) Comparison between mobile-bearing and fixed-bearing knees in bilateral total knee replacements. Int Orthop 29:179–181PubMedCrossRef
10.
Zurück zum Zitat Bhan S, Malhotra R, Kiran EK, Shukla S, Bijjawara M (2005) A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. J Bone Joint Surg Am 87:2290–2296PubMedCrossRef Bhan S, Malhotra R, Kiran EK, Shukla S, Bijjawara M (2005) A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. J Bone Joint Surg Am 87:2290–2296PubMedCrossRef
11.
Zurück zum Zitat Hasegawa M, Sudo A, Fukuda A, Uchida A (2006) Dislocation of posterior-stabilized mobile-bearing knee prosthesis. A case report. Knee 13:478–1482PubMedCrossRef Hasegawa M, Sudo A, Fukuda A, Uchida A (2006) Dislocation of posterior-stabilized mobile-bearing knee prosthesis. A case report. Knee 13:478–1482PubMedCrossRef
12.
Zurück zum Zitat Lu YC, Huang CH, Chang TK, Ho FY, Cheng CK, Huang CH (2010) Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses. J Bone Joint Surg Br 92:500–507PubMedCrossRef Lu YC, Huang CH, Chang TK, Ho FY, Cheng CK, Huang CH (2010) Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses. J Bone Joint Surg Br 92:500–507PubMedCrossRef
13.
Zurück zum Zitat Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA (2008) Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 410:131–138CrossRef Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA (2008) Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 410:131–138CrossRef
14.
Zurück zum Zitat Watanabe T, Yamazaki T, Sugamoto K, Tomita T, Hashimoto H, Maeda D, Tamura S, Ochi T, Yoshikawa H (2004) In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion. J Orthop Res 22:1044–1049PubMedCrossRef Watanabe T, Yamazaki T, Sugamoto K, Tomita T, Hashimoto H, Maeda D, Tamura S, Ochi T, Yoshikawa H (2004) In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion. J Orthop Res 22:1044–1049PubMedCrossRef
15.
Zurück zum Zitat Tamaki M, Tomita T, Yamazaki T, Hozack WJ, Yoshikawa H, Sugamoto K (2008) In vivo kinematic analysis of a high-flexion posterior stabilized fixed-bearing knee prosthesis in deep knee-bending motion. J Arthroplasty 23:879–885PubMedCrossRef Tamaki M, Tomita T, Yamazaki T, Hozack WJ, Yoshikawa H, Sugamoto K (2008) In vivo kinematic analysis of a high-flexion posterior stabilized fixed-bearing knee prosthesis in deep knee-bending motion. J Arthroplasty 23:879–885PubMedCrossRef
16.
Zurück zum Zitat Tamaki M, Tomita T, Watanabe T, Yamazaki T, Yoshikawa H, Sugamoto K (2009) In vivo kinematic analysis of a high-flexion, posterior-stabilized, mobile-bearing knee prosthesis in deep knee bending motion. J Arthroplasty 24:972–978PubMedCrossRef Tamaki M, Tomita T, Watanabe T, Yamazaki T, Yoshikawa H, Sugamoto K (2009) In vivo kinematic analysis of a high-flexion, posterior-stabilized, mobile-bearing knee prosthesis in deep knee bending motion. J Arthroplasty 24:972–978PubMedCrossRef
17.
Zurück zum Zitat Moynihan AL, Varadarajan KM, Hanson GR, Park SE, Nha KW, Suggs JF, Johnson T, Li G (2010) In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty. Int Orthop 34:497–503PubMedCrossRef Moynihan AL, Varadarajan KM, Hanson GR, Park SE, Nha KW, Suggs JF, Johnson T, Li G (2010) In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty. Int Orthop 34:497–503PubMedCrossRef
18.
Zurück zum Zitat Shimizu N, Tomita T, Yamazaki T, Yoshikawa H, Sugamoto K (2011) The effect of weight-bearing condition on kinematics of a high-flexion, posterior-stabilized knee prosthesis. J Arthroplasty 26:1031–1037PubMedCrossRef Shimizu N, Tomita T, Yamazaki T, Yoshikawa H, Sugamoto K (2011) The effect of weight-bearing condition on kinematics of a high-flexion, posterior-stabilized knee prosthesis. J Arthroplasty 26:1031–1037PubMedCrossRef
19.
Zurück zum Zitat Komistek RD, Dennis DA, Mahfouz MR, Walker S, Outten J (2004) In vivo polyethylene bearing mobility is maintained in posterior stabilized total knee arthroplasty. Clin Orthop Relat Res 428:207–213PubMedCrossRef Komistek RD, Dennis DA, Mahfouz MR, Walker S, Outten J (2004) In vivo polyethylene bearing mobility is maintained in posterior stabilized total knee arthroplasty. Clin Orthop Relat Res 428:207–213PubMedCrossRef
20.
Zurück zum Zitat Futai K, Tomita T, Yamazaki T, Tamaki M, Yoshikawa H, Sugamoto K (2011) In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions. Knee Surg Sports Traumatol Arthrosc 19:914–920PubMedCrossRef Futai K, Tomita T, Yamazaki T, Tamaki M, Yoshikawa H, Sugamoto K (2011) In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions. Knee Surg Sports Traumatol Arthrosc 19:914–920PubMedCrossRef
21.
Zurück zum Zitat Tanaka A, Nakamura E, Okamoto N, Banks SA, Mizuta H (2011) Three-dimensional kinematics during deep-flexion kneeling in mobile-bearing total knee arthroplasty. Knee 18:412–416PubMedCrossRef Tanaka A, Nakamura E, Okamoto N, Banks SA, Mizuta H (2011) Three-dimensional kinematics during deep-flexion kneeling in mobile-bearing total knee arthroplasty. Knee 18:412–416PubMedCrossRef
22.
Zurück zum Zitat Yamazaki T, Watanabe T, Nakajima Y, Sugamoto K, Tomita T, Yoshikawa H, Tamura S (2004) Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy. IEEE Trans Med Imaging 23:602–612PubMedCrossRef Yamazaki T, Watanabe T, Nakajima Y, Sugamoto K, Tomita T, Yoshikawa H, Tamura S (2004) Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy. IEEE Trans Med Imaging 23:602–612PubMedCrossRef
23.
Zurück zum Zitat Yamazaki T, Watanabe T, Nakajima Y, Sugamoto K, Tomita T, Maeda D, Sahara W, Yoshikawa H, Tamura S (2005) Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy. Eur J Radiol 53:84–89PubMedCrossRef Yamazaki T, Watanabe T, Nakajima Y, Sugamoto K, Tomita T, Maeda D, Sahara W, Yoshikawa H, Tamura S (2005) Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy. Eur J Radiol 53:84–89PubMedCrossRef
24.
Zurück zum Zitat Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144PubMedCrossRef Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144PubMedCrossRef
25.
Zurück zum Zitat Shiramizu K, Vizesi F, Bruce W, Herrmann S, Walsh WR (2009) Tibiofemoral contact areas and pressures in six high flexion knees. Int Orthop 33:403–406PubMedCrossRef Shiramizu K, Vizesi F, Bruce W, Herrmann S, Walsh WR (2009) Tibiofemoral contact areas and pressures in six high flexion knees. Int Orthop 33:403–406PubMedCrossRef
Metadaten
Titel
In vivo kinematics of high-flex mobile-bearing total knee arthroplasty, with a new post-cam design, in deep knee bending motion
verfasst von
Masahiro Kurita
Tetsuya Tomita
Takaharu Yamazaki
Masakazu Fujii
Kazuma Futai
Norimasa Shimizu
Hideki Yoshikawa
Kazuomi Sugamoto
Publikationsdatum
01.12.2012
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 12/2012
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-012-1673-8

Weitere Artikel der Ausgabe 12/2012

International Orthopaedics 12/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.